Imagine communications Nexio NX1011 MGX, Nexio NX1011 FCP, Nexio NX1011 PTCD, Nexio NX1011 Series, Nexio NX1011 MIOH Hardware Manual

Hardware Guide
Nexio® NX1011 Series
November 2014
Publication Information
© 2014 Imagine Communications Corp.
Proprietary and Confidential.
Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal.
This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.
Trademarks
Nexio® and Nexio AMP® are trademarks or trade names of Imagine Communications or its subsidiaries.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation. All other trademarks and trade names are the property of their respective companies.
Contact Information
Imagine Communications has office locations around the world. For domestic and international location and contact information, visit our Contact page (http://www.imaginecommunications.com/company/contact-us.aspx).
Support Contact Information
For domestic and international support contact information see:
Support Contacts (http://www.imaginecommunications.com/services/customer-care.aspx) eCustomer Portal (http://support.imaginecommunications.com) Academy Training (http://www.imaginecommunicationsacademy.com)
© 2014 Imagine Communications Corp. Proprietary and Confidential. September 2014 | Page 2
Nexio® NX1011 Series Hardware Guide Contents
Contents
Chapter 1 Overview .............................................................................................. 5
Product Configuration .............................................................................................................................. 5
Chassis Components ................................................................................................................................. 7
Front Panel ........................................................................................................................................... 7
Front Panel Buttons .............................................................................................................................. 7
Front Panel Panel LEDs ......................................................................................................................... 7
USB Ports .............................................................................................................................................. 8
Back Panel ................................................................................................................................................. 8
Back Panel Connectors ......................................................................................................................... 9
Ethernet Ports ...................................................................................................................................... 9
Topologies .............................................................................................................................................. 10
NX1011 MGX ...................................................................................................................................... 10
NX1011 MIOH ..................................................................................................................................... 11
NX1011 FCP ........................................................................................................................................ 11
NX1011PTCD....................................................................................................................................... 13
Chapter 2 Rack Mounting the Chassis ................................................................. 14
Choosing a Rack Location ....................................................................................................................... 14
Installing the Server into the Rack .......................................................................................................... 14
Removing the Server from the Rack ....................................................................................................... 15
Chapter 3 Configuring the Software .................................................................... 16
Downloading Nexio Software ................................................................................................................. 16
Registering the Software License ........................................................................................................... 16
Generating a .dc File ........................................................................................................................... 17
Emailing the .dc File............................................................................................................................ 17
Loading the .rc File ............................................................................................................................. 18
Accessing Nexio Config ........................................................................................................................... 18
Chapter 4 Maintaining the System ...................................................................... 19
Nexio Software Updates ......................................................................................................................... 19
Backup and Recovery ............................................................................................................................. 19
Replacing the Boot Drive ........................................................................................................................ 19
© 2014 Imagine Communications Corp. Proprietary and Confidential. September 2014 | Page 3
Nexio® NX1011 Series Hardware Guide Contents
Nexio Monitor ........................................................................................................................................ 19
Opening Nexio Monitor ...................................................................................................................... 20
Reading Ethernet Port Indicators ........................................................................................................... 20
Reading Fibre Channel Card Indicators .................................................................................................. 21
Maintaining Power Supplies ................................................................................................................... 21
Changing Power Supplies ................................................................................................................... 22
Chapter 5 Safety Information .............................................................................. 23
Terms and Symbols ................................................................................................................................. 23
RoHS Directive ........................................................................................................................................ 23
WEEE ....................................................................................................................................................... 24
Electrical Safety Guidelines .................................................................................................................... 24
Power Cords ........................................................................................................................................... 24
Environmental Considerations ............................................................................................................... 25
ESD Guidelines ........................................................................................................................................ 25
Operational Safety Guidelines ................................................................................................................ 26
General Safety ........................................................................................................................................ 26
© 2014 Imagine Communications Corp. Proprietary and Confidential. September 2014 | Page 4
Model
Configuration
NX1011MGX-GE
Nexio Media Gateway 1011
1 RU chassis Dual 8 Gbps Fibre Channel interface connection to NXS3100 or
Farad storage
Hot-swappable redundant power supplies Quad Gigabit Ethernet ports FTP Server software.
NX1011MGX-10GE
Nexio Media Gateway 1011 (10GigE)
1 RU chassis Dual 8 Gbps fibre channel interface connection to NXS3100 or
Farad storage
Hot-swappable redundant power supplies Dual 10-Gigabit Ethernet ports FTP Server software.
NX1011MIOH-GE
Nexio Media Host 1011 (GigE)
1 RU chassis Connects Nexio I/O nodes to NXS3100 storage via Ethernet Hot-swappable redundant power supplies Quad Gigabit Ethernet ports Media host software.
Chapter 1
Overview
The Nexio NX1011 is a 1 rack unit (RU) server featuring mirrored boot drives, redundant hot swappable power supplies, and redundant Fibre Channel connectivity to shared storage.
This document is written for installation professionals and end users. It describes how to install and use the Nexio NX1011 hardware device.
Product Configuration
Several products use Nexio NX1011 hardware. This table lists different product models, configurations, and spares.
© 2014 Imagine Communications Corp. Proprietary and Confidential. September 2014 | Page 5
Model
Configuration
NX1011MIOH-10GE
Nexio Media Host 1011 (10 GigE)
1 RU chassis Connects Nexio I/O nodes to NXS3100 storage via Ethernet Dual 8 Gb Fibre Channel ports Hot-swappable redundant power supplies Quad 10 Gigabit Ethernet ports Media host software.
NX1011 FCP-GE
Nexio FCP Integration Gateway (GigE)
1 RU chassis Integrates Apple's Final Cut Pro non-linear editing software with
the Nexio system.
Quad Gigabit Ethernet ports Software plug-ins to be installed on the Apple FCP workstation.
NX1011 FCP-10GE
Nexio FCP Integration Gateway (10GigE)
1 RU chassis Integrates Apple's Final Cut Pro non-linear editing software with
the Nexio server system.
Dual 10 Gigabit Ethernet ports Software plug-ins to be installed on the Apple FCP workstation.
NX1011SPS
650W power supply for Nexio NX1011 device
NX1011SSD64
64 GB solid-state system drive for Nexio NX1011 series device
NX1011UP-MEM16
System memory upgrade option for Nexio NX1011 series device. Adds 16GB memory for a total of 32 GB.
© 2014 Imagine Communications Corp. Proprietary and Confidential. September 2014 | Page 6
Button
Description
UID
Unit Identification (UID) button. When you press this button, the Universal Identification LED on the front panel and the U-LED on the back panel both light up.
Reset
To reboot the system, press and hold this button for 5 seconds.
Power
Press and hold this button for 5 seconds to turn the power to the server on and off. When you turn the power off, standby power is still supplied to the server.
Chassis Components
The Nexio NX1011 features a 1 RU chassis.
Front Panel
Front Panel Buttons
From left to right, the front panel buttons are listed here.
Front Panel Panel LEDs
From left to right, the LED notification functions are listed here.
© 2014 Imagine Communications Corp. Proprietary and Confidential. September 2014 | Page 7
LED
Description
Universal Information
Fast Blinking Red - Fan failure Solid Red - CPU/Overheat Slow Blinking Red - Power Failure Solid Blue - UID button on front panel is
depressed
NIC2
Flashing indicates network activity on LAN2
NIC1
Flashing indicates network activity on LAN1
HDD
Indicates channel activity. Flashing indicates SSD boot drive activity.
Power
Indicates power is being supplied. This LED should be on when the server is operating.
USB Ports
There are 2 USB ports on the front panel. There are also 2 USB ports on the back panel.
Back Panel
Back panel components are identified in the drawing. Please note that the exact placement of each device may vary slightly from this drawing.
© 2014 Imagine Communications Corp. Proprietary and Confidential. September 2014 | Page 8