Imagine DA-DSR6804+D, DA-DS6804+D, DA-DHR6804+D, DA-DH6804+D Installation And Operation Manual

Delivering the Moment
Installation and Operaon Manual
DA-6804+D
Single- and Dual-Channel
3G HD-SDI, 1.5 G HD-SDI, and SD-SDI Distribuon Ampliers
Edion B
Publicaon Informaon
© 2014 Imagine Communicaons Corp. Proprietary and Condenal.
Imagine Communicaons considers this document and its contents to be proprietary and condenal. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publicaon, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the wrien consent of Imagine Communicaons. All others uses are illegal.
This publicaon is designed to assist in the use of the product as it exists on the date of publicaon of this manual, and may not reect the product at the current me or an unknown me in the future. This publicaon does not in any way warrant descripon accuracy or guarantee the use for the product to which it refers. Imagine Communicaons reserves the right, without noce to make such changes in equipment, design, specicaons, components, or documentaon as progress may warrant to improve the performance of the product.
Trademarks
6800+™, ADC™, CCS Navigator™, Channel ONE™, ChannelView™, ClipSync™, Delay™, D Series™, D Series DSX™, Deliver the Moment™, Delivering the Moment™, FAME™, Farad™, G8™, G Scribe™, HView™, IconMaster™, IconLogo™, IconSta­on™, IconKey™, InfoCaster™, InfoCaster Creator™, InfoCaster Manager™, InfoCaster Player™, InstantOnline™, Invenio®, Live Update™, mCAPTURE™, Magellan™, Magellan CCS Navigator™, Magellan Q SEE™, MulService SDN™, NetPlus™, NetVX™, NewsForce™, Nexio® G8™, Nexio AMP® ChannelView™, Nexio® Channel ONE™, Nexio® ClipSync™, Nexio® Delay™, Nexio® Digital Turnaround Processor™, Nexio® Farad™, Nexio® G Scribe™, Nexio® IconKey™, Nexio® IconLogo™, Nexio® IconMaster™, Nexio® IconStaon™, Nexio® InfoCaster™, Nexio® InfoCaster Creator™, Nexio® InfoCaster Manag­er™, Nexio® InfoCaster Player™, Nexio® InfoCaster Trac™, Nexio® InstantOnline™, Nexio® mCAPTURE™, Nexio® News­Force™, Nexio® NXIQ™, Nexio® Playlist™, Nexio® Remote™, Nexio®RTX Net™, Nexio® TitleMoon™, Nexio® TitleOne™, Nexio® Velocity ESX™, Nexio® Velocity PRX™, Nexio® Velocity XNG™, Nexio® Volt™, OPTO+™, Panacea™, Planum™, Playlist™, Predator II GRF™, Predator II GX™, Punctuate™, Remote™, RTX Net™, QuiC™, Q SEE™, SD STAR™, Selenio™, Selenio 6800+™, SelenioNext™, Selenio X50™, Selenio X85™, Selenio X100™, TitleMoon™, TitleOne™, Velocity ESX™, Velocity PRX™, Velocity XNG™, Versio™, Videotek® SD STAR™, X50™, and X85™ are trademarks of Imagine Communica­ons or its subsidiaries.
Altude Express®, Connectus®, Enabling PersonalizedTV®, ICE® Broadcast System, ICE Illustrate®, ICE Q® algorithms, ICE­PAC®, Imagine ICE®, Inscriber®, Inscriber® Connectus®, Invenio®, NEO®, Nexio®, Nexio AMP®, PersonalizedTV®, Router­Works®, Videotek®, Videotek® ASI STAR®, Videotek® GEN STAR®, and Videotek® HD STAR® are registered trademarks of Imagine Communicaons or its subsidiaries.
Microso® and Windows® are registered trademarks of Microso Corporaon. HD BNC is a trademark of Amphenol Corporaon. Some products are manufactured under license from Dolby Laboratories. Dolby and the double D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc. © 2008 2010 DTS, Inc. All other trademarks and trade names are the property of their respecve companies.
Contact Informaon
Imagine Communicaons has oce locaons around the world. For locaons and contact informaon see:
hp://www.imaginecommunicaons.com/contact us/
Support Contact Informaon
For support contact informaon see:
Support Contacts: hp://www.imaginecommunicaons.com/services/technical support/ eCustomer Portal: hp://support.imaginecommunicaons.com
© 2014 Imagine Communicaons Corp. Proprietary and Condenal
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
DA-DH6804+D
Dual 1×4 3-Gb/s HD-SDI Distribution Amplifiers
DA-DHR6804+D
Dual 1×4 3-Gb/s HD-SDI Distribution Amplifiers with Reclocking
DA-DS6804+D
Dual 1×4 SD-SDI Distribution Amplifiers
DA-DSR6804+D
Dual 1×4 SD-SDI Distribution Amplifiers with Reclocking
Installation and Operation Manual
Edition B May 2011
Contents
About This Manual
Intended Audience .............................................................................................v
Revision History ..................................................................................................v
Writing Conventions ..........................................................................................vi
Obtaining Documents ........................................................................................vi
Unpacking/Shipping Information ......................................................................... vi
Unpacking a Product ...................................................................................vi
Product Servicing ........................................................................................ vii
Returning a Product ................................................................................... vii
Safety Standards and Compliances.................................................................... vii
Safety Terms and Symbols ......................................................................... viii
Restriction on Hazardous Substances (RoHS) Directive ................................ viii
Waste from Electrical and Electronic Equipment (WEEE) Directive .................ix
iii
Introduction
Main Features .................................................................................................... 2
All Models.................................................................................................... 2
DA-DSR6804+D and DHR6804+D Models.................................................... 2
Front Module..................................................................................................... 3
Back Module ..................................................................................................... 3
Signal Flow ........................................................................................................ 4
Maximum 6800+ Fr
ame Power Ratings ........................................................ 6
Installation
Jumpers J1 and J2 (DA-DSR6804+D and DA-DHR6804+D) ................................ 8
Jumper J3 .......................................................................................................... 9
Installing and Removing Modules ...............
Installation ................................................................................................... 9
Removal ....................................................................................................... 9
........................................................ 9
Operation
Automatic Changeover .................................................................................... 11
Reclocking ....................................................................................................... 11
LED Displays .................................................................................................... 12
Copyright © 2011, Harris Corporation
Contents
iv
Status Indicator ......................................................................................... 12
Signal Condition Indicators ........................................................................ 12
Web Browser Control ...................................................................................... 13
CCS Navigator Control .................................................................................... 14
Operating Notes .............................................................................................. 14
Specifications
Inputs .............................................................................................................. 17
Outputs ........................................................................................................... 18
Temperature .................................................................................................... 19
Power Consumption ........................................................................................ 19
Start-Up Time .................................................................................................. 19
Index
Keywords ........................................................................................................ 21
Copyright © 2011, Harris Corporation
About This Manual
This manual details the features, installation procedures, operational procedures, and specifications of the following DA-6804+ series distribution amplifiers:
DA-DH6804+D: Dual 1×4 3-Gb/s HD-SDI distribution amplifiers DA-DHR6804+D: Dual 1×4 3-Gb/s HD-SDI distribution amplifiers with
reclocking
DA-DS6804+D: Dual 1×4 SD-SDI distribution amplifiers DA-DSR6804+D: Dual 1×4 SD-SDI distribution amplifiers with reclocking
v
Intended Audience
This manual is written for engineers, technicians, and operators responsible for the installation, setup, and / or operation of the DA-6804+ ser amplifiers.
Revision History
Table P-1 Manual Revision History
Edition Date Revision History
A February 2010 Initial release
B May 2011 Product changes
ies of distribution
Copyright © 2011, Harris Corporation
About This Manual
vi
Writing Conventions
To enhance your understanding, the authors of this manual have adhered to the following text conventions:
Table P-2 Manual Style an
Term or Convention
Bold Indicates dialog boxes, property sheets, fields, buttons, check
Italics Indicates email addresses, the names of books or publications,
CAPS Indicates a specific key on the k
Code
> Indicates the direction of navigation through a hierarchy of
hyperlink Indicates a jump to another locatio
Internet address Indicates a jump to a
NOTE:
Description
b lists, and selection names
and that need emphasis
CTRL, ALT, or DELETE
Indicates variables or command-line entries, such as a DOS entry or something you type into a field
menu
document or elsewhere
Indicates important information that helps to avoid and t
d Writing Conventions
oxes, list boxes, combo boxes, menus, submenus, windows,
the first instances of new terms and specialized words
eyboard, such as ENTER, TAB,
s and windows
n within the electronic
website or URL
roubleshoot problems
Obtaining Documents
Technical documents can be viewed or downloaded from our website. Alternatively, contact your Customer Service representative to request a document.
Unpacking/Shipping Information
This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble free service.
Unpacking a
Product
Copyright © 2011, Harris Corporation
1 Check equipment for any visible damage that may have occurred during
2 Con
transit.
firm that you have received the front and back module for the correct
product.
DA-6804+D Series
Installation and Operation Manual
3 Contact your dealer if any item on the packing list is missing. 4 Co 5 Remo
ntact the carrier if any item is damaged.
ve all packaging material from the product and its associated
components before you install the unit.
vii
Product Servicing
Returning a
Product
DA-6804+ series modules are not designed for field servicing. All hardware and firmware upgrades, modifications, or repairs require you to return the modules to the Customer Service center.
In the unlikely event that your product fails to operate properly, please contact Customer Service to obtain a Return Authorization (RA) number, and then send the unit back for servicing.
Keep at least one set of original packaging, in the product for servicing. If the original packaging is not available, you can purchase replacement packaging at a modest cost or supply your own packaging as long as it meets the following criteria:
Withstands the weight of the product Holds the product rigid within the packaging Leaves at least two inches of space between the product and the container Protects the corners of the product
Ship products back to us for servicing prepaid and, if possible, in the original pa
ckaging material. If the product is still within the warranty period, we will return
the product prepaid after servicing.
event that you need to return a
Safety Standards and Compliances
You can find the 6800+ Safety Instructions and Standards Manual on the Harris Infrastructure and Networking Documentation and Product Resources DVD, or
download it from our website.
Copyright © 2011, Harris Corporation
viii
About This Manual
Safety Terms and
Symbols
This product manual uses the following safety terms and symbols to identify certain conditions or practices. See the 6800+ Safety Instructions and Standards Manual for more information.
Table P-3 Saf
ety Terms and Symbols
Symbol Description
WARNING: Identifies conditions or
practices that can result in personal injury or loss of life — high voltage is present. Uninsulated dangerous voltage within the product’s enclosure may be sufficient to constitute a risk of electric shock to persons.
CAUTION: Identifies conditions
or practices that can result in damage to the equipment or other property. Important operating and maintenance (servicing) instructions are included in the literature accompanying the product.
Restriction on Hazardous Substances (RoHS) Directive
Directive 2002 / 95 / EC — commonly known as the European Union (EU) Restriction on Hazardous Substances (RoHS) — sets limits on the use of certain substances found in
electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling. The Directive, which took effect on July 1, 2006, refers to the following hazardous substances:
Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr-V1) Polybrominated Biphenyls (PBB) Polybrominated Diphenyl Ethers (PBDE)
In accordance with this EU Directive, products sold in the European Union will be fully RoHS-compliant and “lead-fr equipment sold before July 1, 2006 are exempt from the legislation. Equipment that complies wi in
Figure P-1.
th the EU directive will be marked with a RoHS-compliant symbol, as shown
ee.” Spare parts supplied for the repair and upgrade of
Figure P-1 RoHS Compliance Symbol
Copyright © 2011, Harris Corporation
DA-6804+D Series
Installation and Operation Manual
Waste from Electrical and Electronic Equipment (WEEE) Directive
The European Union (EU) Directive 2002 / 96 / EC on Waste from Electrical and Electronic Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of
electrical and electronic waste products. The objective of the WEEE Directive is to assign the responsibility for the disposal of associated hazardous waste to either the producers or users of these products. As of August 13, 2005, producers or users are required to recycle electrical and electronic equipment at end of its useful life, and must not dispose of the equipment in landfills or by using other unapproved methods. (Some EU member states may have different deadlines.)
In accordance with this EU Directive, companies selling electric or electronic devices in the EU will af your local sales representative for information on returning these products for recycling. Equipment that complies with the EU directive will be marked with a WEEE-compliant symbol, as shown in
fix labels indicating that such products must be properly recycled. Contact
Figure P-2.
ix
Figure P-2 WEEE Compliance Symbol
Copyright © 2011, Harris Corporation
About This Manual
x
Copyright © 2011, Harris Corporation
1
Introduction
The DA-6804+D series of distribution amplifiers distributes serial digital signals according to SMPTE259C, 292M, 424M and DVB-ASI standards (compatibility depends on the model selected).
The following modules are available:
DA-DH6804+D is a dual channel 3 Gb/s HD/SD-SDI distribution amplifier DA-DHR6804+D is a dual channel 3 Gb/s HD/SD-SDI distribution amplifier
with reclocking capability
DA-DS6804+D is a dual channel SD-SDI distribution amplifier DA-DSR6804+D is a dual channel SD-SDI distribution amplifier with reclocking
capability
Each distribution amplifier consists of a front and back module, and operates in
6802+ series frames, occupying two slots. Ten distribution amplifiers can be
FR loaded into a frame.
1
Each distribution amplifier contains two configured for either single channel use (1×8_ACO or 1×8) or independent dual-channel use (2_1×4). Each FR6802+ frame can provide up to 20 channels for serial digital signal distribution.
DA-6804+D “g if no input signal is detected. Power consumption is partially reduced if the module is receiving input, but is not connected to a 75Ω load.
DA-6804+D m edge, or remotely, using an Ethernet connection. Web browser and CCS remote control require either an ICE6800+ module, or a 6800+ETH module installed in the frame. CCS remote control provides additional control functions not included in local control mode.
reen” power-saving distribution amplifiers shut down automatically
odules can be set up, controlled, and monitored either at the card
inputs and eight outputs, and can be
Copyright © 2011, Harris Corporation
Chapter 1
2
Introduction
Main Features
All Models
The main features of the DA-6804+D series are listed below:
Passes signals at data rates from 5 Mb/s to 540 Mb/s (DA-DS6804+D and
DA-DSR6804+D) or from 5 Mb/s to 3 Gb/s (DA-DH6804+D and DA-DHR6804+D)
Four selectable channel configurations:
1×8_ACO: 1 input to 8 outputs with auto changeover 1×8_ In_1: SDI In_1 is distributed to 8 outputs 1×8_ In_2: SDI In_2 is distributed to 8 outputs 2_1×4: 2 independent inputs, each distributed to four outputs as either
SDI In_1 to SDI Out_1 (1-4), or SDI In_2 to SDI Out_2 (1
Input signal presence detection and report Automatic input cable equalization Selectable + 6dB gain to use external passive 75Ω 2×1 splitter (via CCS only) Selectable input EQ bypass Automatic power saving mode if no input signal is detected, or if no output
-4)
load is detected
Local and remote control Hot swapping capability
DA-DSR6804+D and DHR6804+D Models
DA-DSR6804+D and DHR6804+D modules also include the following features:
Reclocking capability for 270 Mb/s SMPTE signals (DA-DSR6804+D), or 270
Mb/s, 1.485 Gb/s, and 2.97 Gb/s SMPTE signals (DA-DHR6804+D)
Three selectable reclocking modes (automatic, manual, enforce bypass) Automatic bypassing of the reclock stage if signal is not lockable Reclock status and data rate report Automatic slew rate control for output signal
Copyright © 2011, Harris Corporation
Front Module
SDI
IN
SDI OUT 1
A
C
B
D
A
C
SDI O UT 2
D
21
B
D A-DH / DA-DHR / DA- DS / DA-DSR 6804+ D
Figure 1-1 DA-6804+D Front Module
DA-6804+D
Installation and Operation Manual
3
Back Module
DA-6804+D series modules cannot be installed in 6800 / 7000 series frames.
Figure 1-2 DA-6
804+D Series Back Module
Copyright © 2011, Harris Corporation
Chapter 1
4 x 4
Driver 1
Driver 2
CPU
Monitoring
and Control
Driver 1
Driver 2
HD/SD-SDI In 1
Equalizer
1
HD/SD-SDI In 2
Equalizer
2
HD/SD-SDI Out 1A
HD/SD-SDI Out 1B
HD/SD-SD I Out 1C
HD/SD-SD I Out 1D
HD/SD-SD I Out 2A
HD/SD-SDI Out 2B
HD/SD-SD I Out 2C
HD/SD-SDI Out 2D
4 x 4
HD/SD-SD I In 1
Equalizer
1
Reclock 1
Driver 1
Driver 2
CPU
Monitoring
and Control
HD/SD-SD I In 2
Equalizer
2
Reclock 2
Driver 1
Driver 2
HD/SD-SDI Out 1A
HD/SD-SDI Out 1B
HD/SD-SDI Out 1C
HD/SD-SDI Out 1D
HD/SD-SDI Out 2A
HD/SD-SDI Out 2B
HD/SD-SDI Out 2C
HD/SD-SDI Out 2D
4
Introduction
Signal Flow
Figure 1-3 DA-DH6804+D Signal Flow Diagram
Figure 1-4 DA-DHR6804+D S
ignal Flow Diagram
Copyright © 2011, Harris Corporation
Installation and Operation Manual
4 x 4
Driver 1
Driver 2
CPU
Monit oring
and Cont rol
Driver 1
Driver 2
SD-SDI In 1
Equalizer
1
SD-SDI In 2
Equalizer
2
SD-SDI Out 1A
SD-SDI Out 1B
SD-SDI Out 1C
SD-SDI Out 1D
SD-SDI Out 2A
SD-SDI Out 2B
SD-SDI Out 2C
SD-SDI Out 2D
4 x 4
SD-SDI In 1
Equalizer
1
Reclock 1
Driver 1
Driver 2
CPU
Monitoring
and Control
SD-SDI In 2
Equalizer
2
Reclock 2
Driver 1
Driver 2
SD-SDI Out 1A
SD-SDI Out 1B
SD-SDI Out 1C
SD-SDI Out 1D
SD-SDI Out 2A
SD-SDI Out 2B
SD-SDI Out 2C
SD-SDI Out 2D
Figure 1-5 DA-DS6804+D Signal Flow Diagram
DA-6804+D
5
Figure 1-6 DA-DSR6804+D Signal Flow
Diagram
Copyright © 2011, Harris Corporation
Chapter 1
6
Introduction
Maximum 6800+ Frame Power Ratings
Table 1-1 describes the maximum allowable power ratings for 6800+ frames.
Note the given maximums befor
e installing any 6800+ modules in your frame.
DA-6804+D se
ries modules cannot be installed in 6800 / 7000 series frames.
Table 1-1 Maximum
6800+ Frame Ty
FR6802+XF (AC power supply)
FR6802+XF4
8
(DC power supply)
FR6802+QXF (AC or DC power supply)
FR6822+ (AC or DC power supply)
Power Ratings for 6800+ Frames
Max. Frame
pe
Power Di
ssipation
Number of Us
able Slots
120 W 20 6 W
105 W 20 5.25 W
120 W 20 6 W
120 W 20 6 W
Max. Power Dissipation
ot
Per Sl
Copyright © 2011, Harris Corporation
2
Installation
CAUTION: Before installing this product, read the 6800+ Series
Safety Instructions and Standards man Infrastructure and Networking Documentation and Product Resources DVD. The document is also downloadable from our
website and contains important information about the safe installation and operation of 6800+ series products.
7
ual shipped with the Harris
Before you install DA-6804+D se
Remove the anti-static shipping pouch, if present, and all other packaging
material. Retain the original packaging materials for possible re-use.
Check the equipment for any visible damage that may have occurred during
transit.
Your DA-6804+D package includes a front module, back module, and Harris
Infrastructure and Networking Documentation and Product Resources DVD.
Contact your Customer Service representative if parts are missing or damaged. See Unpacking/Shipping
returning a product for servicing.
ries modules, perform the following:
Information on page vi for information about
Copyright © 2011, Harris Corporation
8
Jumper J1
Jumper J2
Jumper J3
Chapter 2
Installation
Jumpers J1 and J2 (DA-DSR6804+D and DA-DHR6804+D)
To set the reclocker mode for the DA-DSR6804+D and DA-DHR6804+D at the card-edge, use Jumper J1 (for channel 1) and Jumper J2 ( reclocker remains in AUTO mode if no jumper is set.
for channel 2). The
Table 2-1 J1
Jumper Selection
J1/J2
and J2 Jumper Settings
Pin Setting
Label Description
1/2 AUTO_1/2 Input signal locked at one of these data rates:
(Channel 1/
annel 2)
Ch
3/4 3.0G_1/2 Input signal locked at 2.97 Gb/s*; if not locka
5/6 HD_1/2 Input signal locked at 1.485 Gb/s*; if not lockable, signal
7/8 SD_1/2 Input locked at 270 Mb/s; if not lockable, signal a
9/10 BYPASS_1/2 Enforces signal bypass reclocker
*Not applicable to the DA-DSR6804+
2.97 Gb/s*1.485 Gb/s*270 Mb/s
If not lockable, signal automatically bypasses reclocker
ble, signal automatically
bypasses reclocker
automatically bypa
sses reclocker
utomatically
bypasses reclocker
Figure 2-1 Lo
Copyright © 2011, Harris Corporation
cations for Jumpers J1, J2, and J3
Jumper J3
Table 2-2 J3 Jumper Settings
DA-6804+D
Installation and Operation Manual
Jumper J3 sets the control modes for all of the DA-6804+D modules (see
Figure 2-1 for the jumper location).
9
Pin Setting
1/2 1×8_ACO Locally configures distribution amplifier as single channel (1×8) with automatic
3/4 1×8_IN1 Locally configures distribution amplifier as single
5/6 1×8_IN2 Locally configures distribution amplifier as single
7/8 2_1×4 Locally configures distribution amplifier as dual channel
11/12 REMOTE Enables remote control via CCS; when set to REMOTE, J3 pin
Label Description
changeover
channel (1×8); input is from IN 1
channel (1×8); input is from IN 2
(2-1×4)
s 1-8 are not
functional
Installing and Removing Modules
Installation
DA-6804+D series modules cannot be installed in 6800 / 7000 series frames. See the appropriate 6800+ series frame installation and operation manual for details on installing and operating the frame.
Removal
Always install the back module before the
1 Remo
2 Inse
3 In 4 Attach the necessary
When removing DA-6804+D series products, always remove the front module first.
ve the necessary number of blank back plates from the frame.
Do not discard blank back plates. They configurations.
rting the bottom lip of the back module into the required frame slot, and
then screw it into place. Ensure that the EMI gaskets on the right side of t
place during the installation. The EMI gaskets fit tightly.
sert the front module into the slot holding the corresponding back module.
cables to the back module.
front module. Follow these steps:
may be needed for future
he back module remain in
Copyright © 2011, Harris Corporation
10
Chapter 2
Installation
Copyright © 2011, Harris Corporation
3
11
Operation
Approximately three seconds after powering up, the DA-6804+D module should be fully operational. The module can be set to either local (card-edge) or remote (CCS network) control, using the J3 jumpers setting described on page 9.
The current software version of a DA-6804+D m CCS-enabled control panel or a CCS software application. Default settings cannot be recalled on this module.
Automatic Changeover
The signal at SDI In_1 is distributed to 8 outputs. If the signal at SDI In_1 is lost, the outputs are switched to SDI In_2 (the module must be able to detect a signal at SDI In_2). Using the Hysteresis parameter, you can set the amount of delay before the module switches over to SDI In_2, and before the problem is reported to CCS.
When the signal returns at SDI
In_1 from SDI In_2.
Reclocking
odule can only be viewed using a
In_1, the outputs automatically switch back to SDI
The DA-DSR6804+D can reclock 270 Mb/s SD-SDI signals; the DA-DHR6804+D, can reclock 270 Mb/s, 1.485 Gb/s, and 2.97 Gb/s SMPTE signals. If the input data is not at one of those rates, the reclocker function will not function. Instead, the signal will pass through the module.
Copyright © 2011, Harris Corporation
12
Status Indicator
Signal Condition Indicators
Chapter 3
Operation
LED Displays
LEDs on the front edge of the front module report the operating status when the power is on and signal is applied. The system status and signal condition LEDs are shown in Figure 3-1. The individual LEDs are described on page 12.
Status Indicator
Signal Condition
dicators
In
Figure 3-1 LED Locations
Table 3-1 Status Indicator LED Descriptions
LED Color Meaning
Off There is no power to the module;
Red The module detects an alarm condition.
Green There is power to the module; the module is operating properly.
Table 3-2 Signal Condition LED Descriptions
Name Color Function
PRES Green Input signal is present
Off Input signal is absent
LOCK Green Input signal is locked
Off Input signal is unlocked and appears on the
ou
tputs
270 Green Input signal is reclocked at 270 Mb/s
the module is not operational.
Copyright © 2011, Harris Corporation
Off Input signal is not reclocked
DA-6804+D
Installation and Operation Manual
13
Table 3-2 Sign
Name Color Function
1.5G Green Input signal is reclocked at 1.485 Gb/s
3.0G Green Input signal is reclocked at 2.97 Gb/s
Alarms for the DA-6804+D modules are logged and monitored by software control applications. See the your software control user manual or online help for more information.
Table 3-3 Alarm Defin
Alarm Name Alarm Description
Ch. 1 and 2 Loss of Input
Ch. 1 and 2 Loss of Lock
al Condition LED Descriptions (Continued)
Off Input signal is not reclocked
Off Input signal is not reclocked
itions
The input signal for the designated channe
The input signal for the designated channe
l is missing.
l is not locked.
Alarm
evel
L
Major
Major
Web Browser Control
NOTE: This interface requires an Ethernet connection. Your frame must have an 6800+ETH
To use this control method, open a web browser and enter the IP address of the frame in the display.
A tree view of the frame and its contents is displayed at the left the + button (or click on the component name) to expand the tree view. Information corresponding to the selection is displayed in the control pane to the right of the tree view.
Click the - bu
When you select the frame and the software displays the item list in the tree view and the item values on the control panel.
Read-only parameters are displayed as black characters w Adjustable parameter values are displayed as black characters with a white background; these boxes appear grey if Jumper J3 is set to LOCAL.
or ICE6800+ module installed.
Address field, and then click Enter at the 6800+ Control Interface
of the screen. Click
tton to collapse the tree view.
slot for a distribution amplifier module location,
ith a grey background.
Copyright © 2011, Harris Corporation
14
Chapter 3
Operation
Figure 3-2 Web-Enabled Control Display
CCS Navigator Control
In CCS Navigator, when you select the frame and slot for the module location, the software displays the item values on the control pane.
Read-only parameters values are displayed as gr background. Adjustable parameter values are displayed as black characters on a white background; these boxes appear grey if Jumper J3 is set to LOCAL.
Operating Notes
When you set the control parameters on DA-6804+D series distribution amplifiers, observe the following:
If you make changes to certain parameters, other related parameters may also
be affected.
When you change a parameter, the effect is immediate. However, the module
requires up to 30 seconds to save the latest change. After 30 seconds, the new settings are saved and will be restored if the module loses power and must be restarted.
een characters on a black
Copyright © 2011, Harris Corporation
DA-6804+D
Installation and Operation Manual
Table 3-4 Remotely Controlled Parameters Bold text = De
fault setting [RO] = Read only/feedback
Path Parameter Range Description
Processing Serial Number [RO] String Serial number for the module
License Key String License key number for the module
Other Output Config.
Ch.1 and Ch. 2 Signal
resent [RO]
P
Ch.1 and Ch.2 Loss of I
nput Alarm
Current Input [RO] (valid in 1×8 with ACO
ode output
m
Ch.1 1×8 with ACOCh.1 1×8Ch.2 1×82×4
NoYes
DisabledEnabled
N/ACh. 1Ch. 2
Selects module output configuration as du
al 1×4 or 1×8, 1 input routed to all outputs; or 1×8 with input 2 routed to all outputs
Indicates if the input signal for the
esignated channel is present
d
Enables or disables the Loss of Input
m for the designated channel
alar
Indicates if the input
signal is channel
1 or channel 2
configuration)
Ch. 1 and Ch. 2 Slew Rate
SDHDAuto
Controls output/rise fall time for the d
esignated channel
SD – Output rise/fall time complies
with SMPTE 259M
HD – Output rise/fall time complies
with SMPTE 424M /292M
Auto – Automatically selects proper
rise/fall time based on incoming signal
15
Hysteresis 0.1 to 0.
Green Mode
Out 1A to Out 2D Cable Fa
ult [RO]
Ch.1 and Ch.2 Data Rate [RO
]
Ch. 1 and Ch.2
e-Clocking Mode
R (DA-DHR6804+D and DA-DSR6804+D)
Ch.1 and Ch.2 Loss of Lock Alarm
EnabledDisabled
YesNo
Unknown270 Mb/sBypassHD3G
Auto270 Mb/sBypassHD3G
DisabledEnabled
5 seconds Sets the period between loss of signal
and automatic changeover; CCS is automatically notified
Enables or disables the use of the
ower-saving (“green”) mode
p
Reports termination fault or loss of
ignal for the corresponding output
s
Displays the locked data rate for the
esignated channel
d
Selects the reclock rate for the
esignated channel input
d
Enables or disables Loss of Lock alarm
designated channel
on the
Copyright © 2011, Harris Corporation
16
Chapter 3
Operation
Copyright © 2011, Harris Corporation
4
17
Specifications
Inputs
Table 4-1 Electrical Channel Input Specifications
Item Specification
Number of inputs 2
Signal type
Connector BNC per IEC169-8
Impedance 75Ω
Return loss
Maximum signal level 0.88 V
Cable equalization
DA-DH6804+D and DA-DHR6804+D:
3G-SDI, HD-SDI, SD-SDI, ASI
DA-DS6804+D and DA-DSR6804+D:
SD-SDI, ASI
All models: >15 dB, 5 MHz to 1.5 GHzDA-DH6804+D and DA-DHR6804+D:
>10 dB, 1.5 GHz to 3.0 GHz
All models: 0 – 1,312 ft (0 – 400 m) for 270 Mb/sDA-DH6804+D and DA-DHR6804+D:
0 – 656 ft (0 – 200 m) for 1.5 Gb/s0 – 410 ft (0 – 125 m) for 3.0 Gb/s
Copyright © 2011, Harris Corporation
18
Chapter 4
Specifications
Outputs
Table 4-2 Electrical Channel Output Specifications
Item Specification
Number of outputs 8
Signal type
DA-DH6804+D and DA-DHR6804+D:
3G-SDI, HD-SDI, SD-SDI, ASI
DA-DS6804+D and DA-DSR6804+D:
SD-SDI, ASI
Connector BNC per IEC169-8
Impedance 75Ω
Return loss
All models: >15 dB, 5 MHz to 1.5 GHzDA-DH6804+D and DA-DHR6804+D:
>10 dB, 1.5 GHz to 3.0 GHz
Signal amplitude 800 mV ± 10%
DC offset 0.0 V ± 0.5 V
Rise and fall time
All models: 400-700 ps for SD-SDI, ASIDA-DH6804+D and DA-DHR6804+D:
<270 ps for HD-SDI<135 ps for 3G-SDI
Overshoot <10%
Reclocking rates
DA-DS6804+D and DA-DSR6804+D:
270 Mb/s
DA-DH6804+D and DA-DHR6804+D:
270 Mb/s, 1.485 Gb/s, 2.97 Gb/s
Jitter
DA-DH6804+D and DA-DHR6804+D:
<0.3 UI for 3G-SDI<0.2 UI for HD-SDI
All models: <0.2 UI for SD-SDI, ASI
Copyright © 2011, Harris Corporation
DA-6804+D Series
Installation and Operation Manual
19
Temperature
Power
Consumption
Start-Up Time
Table 4-3 T
Item Specification
Performance Tem
Operating Temperature 32° to 122°F (0° to 50°C)
and
Table 4-4 Power Consumption Specifications
Item Specification
Normal Mode <3.8 W
Sleeping (Green) Mode <1.5 W
Module start-up time is approximately 3 seconds.
emperature Specifications
41° to 104°F (5° to 40°C)
perature
Copyright © 2011, Harris Corporation
20
Chapter 4
Specifications
Copyright © 2011, Harris Corporation
Keywords
Index
A
Alarm definitions 13 Automatic changeover 11
21
O
Operating notes 14 Output specifications 18
B
Back module diagram 3
C
Card-edge LEDs 12 CCS Navigator control 14
F
Features of the modules 2 Front module illustration 3
H
Hysteresis parameter 11
I
Input specifications 17 Installing and removing modules 9
J
Jumpers 8–9
P
Parameters 15 Power consumption specifications 19 Power ratings of the frames 6
R
Reclocking 11 Removing modules 9 Restriction on Hazardous Substances
(RoHS)
viii
Return Authorization (RA) number vii Revision history of manual v
S
Servicing the module vii Shipping information vi Signal condition indicators 12 Signal flow diagrams 4–5 Specifications 17–19 Start-up time 19 Status indicator 12
T
Temperature specifications 19
L
LED displays 12
M
Main features of the modules 2 Maximum frame power ratings 6
U
Unpacking information vi
W
Waste from Electrical and Electronic
Equipment (WEEE)
Web browser control 13
Copyright © 2011, Harris Corporation
ix
22
Index
Copyright © 2011, Harris Corporation
For more information, please visit www.broadcast.harris.com.
Harris is a registered trademark of Harris Corporation. Trademarks and tradenames are the property of their respective companies.
Broadcast Communications Division
25 Dyas Road | North York, ON CANADA M3B 1V7 | Tel: (416) 445 9640
www.broadcast.harris.com
©2011 Harris Corporation
Loading...