WARNING
"This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable codes
and requirements of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage, personal injury or
loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit."
BURNER
SR
R
P
DCC
DUAL
DUAL (only AUX)
SR
R
P
DCC
DUAL
DUAL (only AUX)
GAS
NATURAL (A)
NATURAL (A)
NATURAL (A)
NATURAL (A)
NATURAL (A)
NATURAL (A)
PROPANE (E)
PROPANE (E)
PROPANE (E)
PROPANE (E)
PROPANE (E)
PROPANE (E)
IMPUT RATE
[Btu/h]
7000
10500
10500
16500
20000
2800
7000
10500
10500
16500
20000
2800
ORIFICE SIZE
(1/100) mm
120
145
145
190
75+190
75
75
90
92
117
44+120
44
SIMMER RATE
[Btu/h]
1400
2000
3100
6200
6000
900
1400
2000
3100
6200
6000
900
BY-PASS ORIFICE
SIZE
(1/100) mm
Adj.*
Adj.*
Adj.*
Adj.*
Adj.*
Adj.*
32
40
52
75
27+60
27
CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the
conversion. The kit for the gas conversion of the burners is relevant to the model of the appliance indicated on the
label sti-cking to the first page of this booklet. The kit contains the number and type of orifices necessary for the
conversion, all the necessary instructions, a label to stick onto the old one to show the new setting (see table 2) and
the label to be completed by the technician who performs the conversion. The appliance is pre-adjusted in factory
for the gas indicated on the label put on the gas inlet pipe. For the conversion to another gas refer to table 3.
The positions, types of burner and relevant orifices for the models included in this booklet are depicted in table 3.
The only operation to perform after conversion to a gas different from that shown on the rating plate/label is the
adjustment of the minimum gas flow. (See page 3 of this leaflet). After conversion remember to put the new gas
indication label (supplied in the conversion kit) as close as possible to the existing rating plate, then check the
regular ignition of the burners (see pages 3 and 4 of this leaflet, “Lighting the burners”).
If the appliance is installed at an altitude exceeding 2,000 ft, a new set of orifices can be requested from the
supplier or an authorised service parts distributor.
NOTE: Due to the lower atmospheric pressure at higher altitudes, foods tend to take longer to cook. Therefore,
recipe adjustments should be made in some cases. In general, no recipe adjustment is necessary for yeast-risen
baked goods, although allowing the dough or batter to rise twice before the final pan rising develops a better
flavor. Try making the adjustments below for successful recipes. Take note of the changes that work best and mark
your recipesaccordingly. You may also consult a cookbook on highaltitude cooking for specific recommendations.
WARNING: after first installation of the appliance, after gas conversion kit installation or after any service
intervention concerning main gas parts of the appliance, make the leak test using water with soap on the gas
connections in order to verify the correct installation. Do not use fire for gas leak testing. The test is valid if there is no
bubble or foam build-up during a period of one minute.
WARNING: Save the orices removed from the appliance for future use
NOTE: To go back to the original set replace old orices as shown
Page 4
BURNERS OF THE TOP
- Replacement of the injectors
Procedure: SR - R - P • small solid top burner
•Remove the grill and the burners from the hob.
•Bruciatori SR – R – P :
SR – R – P burners: unscrew injectors “U” using a 7 mm
spanner (fig. 1) and replace them with those for
newgas according to table number 2 on page 20.
Save the orifices removed from the appliance for
future use.
the
Procedure: DCC
•DCC – Dual burners: unscrew the 2 screws “P” and
remove cover “C” fig.2.
•unscrew injectors “U” using a 7 mmspanner (fig.3,
fig.4) and replace them with those for the new gas
according to table number 1 below 13. Save the
orifices removed from the appliance for future use.
Procedure: DUAL
•Remove the grill and the burners from the hob.
•Unscrew injectors “U” using a 7-mm spanner (fig. 8, fig
10) and replace them with those for the new gasaccording to table number 3. Save the orifices removed
from the appliance for future use.
3
Page 5
ADJUSTING THE MINIMUM GAS FLOW
When installing the cooker you must check that the minimum gas flow of the burners on is correctly regulated. If the
type of gas is changed it is indispensable to adjust the minimum flow. The adjustment procedure is as follows.
Burners on the hob (g. 13)
1. Light one burner at a time and turn the flame up to maximum
2. Remove the knob of the corresponding gas tap and insert screwdriver in the screw as shown in figure 14a
or 14b (DUAL).
3. Turn the tap to minimum position.
4. Unscrew, turning to the left, to increase the flame, or screw to the right to decrease it
5. If a liquid gas is used (Butane - Propane), the regulating screw must be fully screwed in
By-pass
r egula-
ting
AUXAUX
Figure 13 Figure 14a
Figure 14b (DUAL)
LIGHTING THE BURNERS
The index above the knobs will help you to find the corresponding burner. Press the knob by turning it
counterclockwise and bring it to the ignition position; keep the knob pressed for about 5 seconds so that upon its
release the flame remains alight. In case of unsuccessful ignition wait 5 minutes before relighting and repeat the
operation.
SymbolSymbol
Function
off
maximum
minimum
index
lighting
OFF
Recommended pans according to burner size:
Burners
Meduim
Large
Fish burner
Ring
Dual - Ring
4
ID
SR
R
P
TC/DCC
DUAL
Diameter Ø (cm)
10 ÷ 20
20 ÷ 24
oval pans (380 x 185)
22 ÷ 28
24 ÷ 30
Page 6
IGNITION OF THE “DUAL” BURNER
off
maximum
minimum
index
lighting
ADJUSTMENT OF THE PRESSURE REGULATOR FOR USE WITH DIFFERENT TYPE OF GAS
The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural
Gas at a nominal outlet pressure of 5”w.c. or Propane at a nominal outlet pressure of 10”w.c. and it is prearranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging labels
affixed on the appliance, package and Instruction booklet.
If Natural gas is converted to Propane, also the by-pass orifice has to be changed.
The regulating screw of the by-pass orifice must be fully screwed in.
To convert the regulator (Fig.6 and Fig.7) for use with the other gas (different from the one for which it is pre-arranged) it is enough perform the following operations:
1. Unscrew by hand the upper metal stopper of the regulator.
2. Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward screw
it again in opposite way under the metal stopper(for gas reference see the written “Propane” and “NAT” with
relative indicating arrows on the white piece).
3. Screw again by hand the metal stopper in the original position on the regulator. Operating in this way the gas
regulator is converted for use with the other gas/pressure
Fig. 6 Pressure regulator
Gas Supply Specifications
Gas
Type
Natural561/2 psi
LP10111/2 psi
Manifold
Pressure (WC)Pressure
Pressure (WC)
Max. Input Min. Gas Supply
Fig. 7
u
that system.
5
Page 7
CORRECT RELATIONSHIP BETWEEN THE IGNITER
AND THE MAIN BURNER
UM30D (N/W/Q/QN)(E3)
UM096D (N/W/Q/QN)(E3)
UMD106D (N/W/Q/QN)(E3)
6
Page 8
CORRECT RELATIONSHIP BETWEEN THE IGNITER
AND THE MAIN BURNER
UM09FD (N/W/Q/QN)(E3)
UMD10FD (N/W/Q/QN)(E3)
UM09PD (N/W/Q/QN)(E3)
7
Page 9
CORRECT RELATIONSHIP BETWEEN THE IGNITER
AND THE MAIN BURNER
UM127D (N/W/Q/QN)(E3)
UM128D (N/W/Q/QN)(E3)
8
Page 10
ORIFICE
(1/100) mm
INJECTORS FOR THE APPLIANCE INSTALLED AT AN ALTITUDE
EXCEEDING 2000 ft
CORRECT RELATIONSHIP BETWEEN THE IGNITER
AND THE MAIN BURNER
UM159D (N/W/Q/QN)(E3)
INJECTORS FOR THE APPLIACE INSTALLED AT AN ALTITUDE
EXCEEDING 2000 ft
BURNERGAS
SR
R
P
DCC
DUAL
DUAL (only AUX)
SR
R
P
DCC
NATURAL (A)117
NATURAL (A)141
NATURAL (A)141
NATURAL (A)185
NATURAL (A)74+185
NATURAL (A)74
LP (E)74
LP (E)87
LP (E)88
LP (E)112
SIZE
DUAL
DUAL (only AUX)
LP (E)
NATURAL (A)43
42+117
9
Page 11
INSTRUCTIONS TO AFFIX
THE CONVERSION KIT LABEL
area for afxing
the conversion plate
area for identication label
of the service agency making
the conversion
10