Iluminarc IP Series, Ilumipod Inground IP Series User Manual

Page 1
u
IIllu
mii
m
poo
p
d II
d
nggrroo
n
u
u
n
n
d II
d
User Manual
P
Seerriieess
S
Page 2
Edition Notes
Edition Notes
The Ilumipod Inground IP Series User Manual Rev. 01f covers the description, safety precautions, installation, programming, operation, and maintenance of the Ilumipod Inground 36 IP RGB, Ilumipod Inground 36 IP VW, and Ilumipod Inground Tri-12 IP products. ILUMINARC User Manual Rev. 01f in July 2011.
®
released this edition of the Ilumipod Inground IP Series
Trademarks
The ILUMINARC® logo, the ILUMINARC® name, and all other trademarks in this document related to services or products by ILUMINARC Any other product names, logos, brands, company names, or trademarks featured or referred to within this document are the property of their respective trademark holders.
®
are trademarks owned or licensed by ILUMINARC®, its affiliates, or subsidiaries.
Copyright Notice
The entire content of this document, except where applicable and unless otherwise noted, is solely owned by ILUMINARC
© Copyright 2011 ILUMINARC All rights reserved. Electronically published by ILUMINARC
®
, a wholly owned trademark of CHAUVET & Sons Inc.
®
®
in the United States of America.
Manual Usage
ILUMINARC® authorizes its customers to download and print this manual for professional information purposes only. ILUMINARC manual or its content for any other purpose without its written consent.
®
expressly prohibits the usage, copy, storage, distribution, modification, or printing of this
Document Printing
For better results, print this document in color, on letter size paper (8.5 x 11 inches), double sided. If using A4 paper (210 x 297 mm), configure your printer to scale the content of this document to A4 paper.
Intended Audience
Any person in charge of installing, operating, and/or maintaining any of these products should read the Guide that shipped with it and this manual in their entirety before installing, operating, or maintaining the product.
Disclaimer
ILUMINARC® believes that the information contained in this manual is accurate in all respects. However, ILUMINARC right to revise this document and to make changes from time to time in the content hereof without obligation of ILUMINARC a commitment by ILUMINARC new edition of it to incorporate such changes.
®
assumes no responsibility for any error or omissions in this document. ILUMINARC® reserves the
®
to notify any person or company of such revision or changes. This does not constitute in any way
®
to make such changes. ILUMINARC® may issue a revision of this manual or a
ILUMINARC® Publications Hot Line
If you have any comments about the accuracy of this document or general suggestions regarding how we can improve it, please call us at (954) 923-3680. You can download the latest versions of all ILUMINARC manuals from www.iluminarc.com.
®
products’
Document Revision
The Ilumipod Inground IP Series User Manual Rev. 01f supersedes all previous versions of this manual. Please discard any older versions of this manual you may have, whether in printed or electronic format, and replace them with this version.
Ilumipod Inground IP Series User Manual
Page 3
Table of Contents
Table of Contents
1. Introduction ...................................................................................................... 1
What is in the Box ........................................................................................................ 1
Unpacking Instructions ................................................................................................. 1
Text Conventions ......................................................................................................... 1
Safety Notes ................................................................................................................. 2
Personal Safety ................................................................................................................... 2
Installing .............................................................................................................................. 2
Power and Wiring ................................................................................................................ 2
Operation ............................................................................................................................. 2
2. Product Description ........................................................................................ 3
Common Features ........................................................................................................ 3
Ilumipod Inground 36 IP VW Features ................................................................................. 3
Ilumipod Inground 36 IP RGB Features ............................................................................... 3
Ilumipod Inground Tri-12 IP Features .................................................................................. 3
Product Dimensions ..................................................................................................... 4
3. Installation ........................................................................................................ 5
Installation Notes .......................................................................................................... 5
Installation Sleeve Orientation ............................................................................................. 5
Installation Sleeve Setup ..................................................................................................... 5
Beam Angle Adjustment ...................................................................................................... 6
AC Power ..................................................................................................................... 7
Input Voltage and Frequency............................................................................................... 7
Power Consumption ............................................................................................................ 7
Junction Box Wiring ...................................................................................................... 7
Power Wiring ....................................................................................................................... 7
Signal Wiring ....................................................................................................................... 8
External Wiring ............................................................................................................. 8
Power Distribution ............................................................................................................... 8
Signal Distribution ................................................................................................................ 8
Controllers .................................................................................................................... 9
DMX Controller .................................................................................................................... 9
ILUMICON ........................................................................................................................... 9
Ilumicode ........................................................................................................................... 10
    
  
    
                
4. Operation ........................................................................................................ 11
Ilumicode .................................................................................................................... 11
Ilumicode Panel Description .............................................................................................. 11
Menu Map .................................................................................................................. 11
White Functions Menu Map ............................................................................................... 11
RGB Functions Menu Map ................................................................................................ 12
Programming .............................................................................................................. 13
DMX Personality ................................................................................................................ 13
DMX Starting Address ....................................................................................................... 13
Dimmer .............................................................................................................................. 13
ILUMICON Control ............................................................................................................ 14
Static Color ........................................................................................................................ 14
Color Calibration ................................................................................................................ 14
Color .................................................................................................................................. 14
Reset ................................................................................................................................. 14
DMX Values ............................................................................................................... 15
ARC 1 ................................................................................................................................ 15
ARC 1 + D ......................................................................................................................... 15
ARC FULL ......................................................................................................................... 15
SPECIAL 1 ........................................................................................................................ 16
VW ..................................................................................................................................... 16
VW + D .............................................................................................................................. 16
Ilumipod Inground IP Series User Manual (Rev. 02 ) i
                    
Page 4
Table of Contents
SOLID ................................................................................................................................ 16
5. Technical Information ................................................................................... 17
Product Maintenance ................................................................................................. 17
Product Repairs .......................................................................................................... 17
Troubleshooting Guide ............................................................................................... 18
Exploded View ............................................................................................................ 19
Photometrics .............................................................................................................. 20
Ilumipod Inground 36 IP 15º VW ....................................................................................... 20
Ilumipod Inground 36 IP 30º VW ....................................................................................... 21
Ilumipod Inground 36 IP 15º RGB ..................................................................................... 22
Ilumipod Inground 36 IP 30º RGB ..................................................................................... 23
Ilumipod Inground Tri-12 IP 16º ......................................................................................... 24
LED Disclaimer ........................................................................................................... 25
LED Life ............................................................................................................................. 25
LED Binning....................................................................................................................... 25
Color Rendering Index (CRI) ............................................................................................. 25
Returns Procedure ..................................................................................................... 26
Claims ......................................................................................................................... 26
Contact Us .................................................................................................................. 26
Technical Specifications ............................................................................................. 27
Ilumipod Inground 36 IP VW .............................................................................................. 27
Ilumipod Inground 36 IP RGB ............................................................................................ 28
Ilumipod Inground Tri-12 IP ............................................................................................... 29
     
        
   
 
ii Ilumipod Inground IP Series User Manual (Rev. 02)
Page 5
1. Introduction
This icon indicates useful, although non-
critical information.
This icon indicates
important installation or configuration information. Failure to comply with this information may prevent the product from functioning correctly.
This icon indicates critical
installation, configuration, or operation information. Failure to comply with this information may render the product partially or completely inoperative, damage third-party equipment, or cause harm to the user
The term “DMX” used throughout
this document refers to the USITT DMX512-A transmission protocol.
What is in the Box
One Ilumipod Inground IP product (36 IP RGB, 36 IP VW, or Tri-12 IP) Warranty Card Quick Reference Guide
Unpacking Instructions
Immediately upon receiving a product from ILUMINARC®, carefully unpack the carton. Check the contents of the box to ensure that all parts are present and that they are in good condition. If any part appears damaged from shipping, or if the carton shows signs of mishandling, see the Claims section in the Technical Information chapter.
Text Conventions
Convention Meaning
1~512
50/60
“ILUMICON UM”
<SET>
SETTINGS
MENU > SETTINGS
1~10
Yes/No
ON
A range of values in the text A set of mutually exclusive values in the text The name of another publication or manual A button on the product’s control panel A product function or a menu option A sequence of menu options A range of menu values from which to choose in a menu A set of two mutually exclusive menu options in a menu A unique value to enter or select in a menu
Introduction
Ilumipod Inground IP Series User Manual (Rev. 02) 1
Page 6
Introduction
product. Any reference to servicing you may find in this User Manual will only apply to properly ILUMINARC technicians. Do not open the housing or attempt any repairs unless you are an ILUMINARC© authorized technician.
regulations for the proper installation of this product.
you sell this product to another user, make sure that they also receive this manual.
Inground IP product may require service, please contact ILUMINARC Technical Support.
There are no user serviceable parts inside this
®
Please refer to all applicable local codes and
Keep this manual for future consultation. If
In the unlikely event that your Ilumipod
authorized
®
Safety Notes
Please read all the following safety notes carefully because they include important information on how to install, use, and maintain this product safely.
Personal Safety
Avoid direct eye exposure to the light source while the product is on. Always disconnect the Ilumipod Inground IP product from its power source before
servicing.
Always connect the Ilumipod Inground IP product to a grounded circuit to avoid the risk
of electrocution.
Installing
The Ilumipod Inground IP products are for o utdoor use and they can work while
submerged in up to 1 m of water (IP67) for 30 min.
Observe the installation instructions regarding drainage to ensure that the water level is
never higher than 1 m to comply with the IP67 rating.
Power and Wiring
Always make sure that you are connecting this product to the proper voltage, as per the
specifications in this manual or on the product’s sticker.
Never connect this product to a dimmer pack. Make sure that the power cable is not cracked, crimped, or damaged. Make sure that the sealed cover is properly adjusted to avoid water entering the unit.
Operation
The maximum ambient temperature (Ta) is 104° F (40° C). Do not operate this product
at a higher temperature.
In case of a serious operating problem, stop using this product immediately!
2 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 7
2. Product Description
Product Description
Other than their LED configuration and programming
features, these three products share the same dimensions, as well as the installation, wiring, and troubleshooting procedures.
The lenses in
these three
products are non-
changeable. Therefore, make sure to use the right product order code for the desired lens angle.
The Ilumipod Inground IP Series includes three separate products: Ilumipod Inground 36 IP RGB, Ilumipod Inground 36 IP VW, and Ilu mipod Inground Tri-12 IP.
Common Features
Remotely addressable DMX-512 LED ingro un d wash light IP67 ingress protection IP67 stainless steel gland nuts for cable entry Adjustable module angle Cast aluminum and stainless steel housing Impact resistant glass lens cover (drive-over rated) Polished stainless steel mounting ring Ilumicode compatible ILUMICON compatible
Ilumipod Inground 36 IP VW Features
Operating modes:
1-channel: Dimmer 2-channel: Warm white, cool white 3-channel: Warm white, cool white, dimmer
High power 1 W (750 mA) Warm White and Cool White LEDs Installed (non-changeable) optical system:
15 lenses Product order code: 11036010 30º lenses Product order code: 11036008
Ilumipod Inground 36 IP RGB Features
Operating modes:
1-channel: Dimmer 3-channel: RGB control 4-channel: RGB, dimmer 6-channel: RGB per module 7-channel: RGB, dimmer, macro, strobe, dimming speed
High power 1 W (750 mA) Red, Green, and Blue LEDs Blackout/static/dimmer/strobe/pulse Installed (non-changeable) optical system:
15 lenses Product order code: 11036009 30º lenses Product order code: 11036007
Ilumipod Inground Tri-12 IP Features
Operating modes:
High power 3 W (1,050 mA) tri-color LEDs Blackout/static/dimmer/strobe/pulse Installed (non-changeable) optical system:
Ilumipod Inground IP Series User Manual (Rev. 02) 3
1-channel: Dimmer 3-channel: RGB control 4-channel: RGB, dimmer 6-channel: RGB per module 7-channel: RGB, dimmer, macro, strobe, dimming speed
16 lenses Product order code: 11012001
Page 8
Product Description
Product Dimensions
(All Ilumipod Inground IP Series models)
4 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 9
3. Installation
Always keep the
power cables
away from the
signal cables by running them in different conduits and using separate distribution boxes.
Ilumipod Inground
IP products can
support a distributed load of up to 3,000 kg (6,614 lbs) when properly installed.
Installation Notes
The Ilumipod Inground IP products consist of two parts, the product housing and the concrete installation sleeve. The product housing is IP67 rated, but the installation sleeve is not.
Carefully read the installation instructions for the concrete installation sleeve regard ing leve ling and drainage.
You will have to run the AC power and signal cables in to the concrete installation sleeve and the product’s housing.
Do not use the product’s junction box to extend the power or signal cables to other units because it may compromise the IP rating of the junction box. Instead, use individual cables from the product to the corresponding distribution boxes.
Installation Sleeve Orientation
Orient the installation sleeve to allow the signal cable to enter the sleeve using one of th e four cable inlets and the power cable to use the opposite inlet, as seen in the following figure. This will reduce the stress to the signal and power cables when setting down the product, while keeping them separated under the product’s housing.
Installation Sleeve Setup
When setting up the installation sleeve, make sure any water that entered the sleeve can drain out on its own. Locate the installation sleeve above the normal drainage level so the product is never under more than 1 m of water (IP67) during heavy rain.
In addition, make sure that the installation sleeve and the stainless steel collar are horizontal and even with the ground surface. This helps to distribute the load uniformly over the product’s surface and avoids creating dangerous bumps.
Installation
Ilumipod Inground IP Series User Manual (Rev. 02) 5
Page 10
Installation
Make sure to disconnect the power to the
product before opening it.
Be careful when opening and
closing the product’s housing as it may compromise the product’s IP67 rating.
Beam Angle Adjustment
Ilumipod Inground IP products have two LED modules each. You can adjust the angle of each of these modules to spread or narrow the product’s beam. Follow these steps:
1. Loo s en the Allen bolts on the stainless steel collar by turning no more than a turn
or two counter-clockwise to release the aluminum latch from its “locked” position.
2. Lift th e prod uct from the installation sleeve, making sure not to stretch the power
and signal cables.
3. Loosen four of the six nuts that hold the collar to the housing, leaving untouched
any two adjacent nuts.
4. W ait a few seconds for the seal to expand, which lowers the possibility of
damaging the seal.
5. Co mplete the removal of the two remaining nuts.
6. Re move the stainless steel collar.
7. Carefully lift and remove the protective glass and the attached seal, making sure
not to reverse the glass.
8. Using only your hands, push on the sides of each module to adjust its angle, as
shown in the figure below.
9. Replace the glass and then re-silicone the seal to insure a watertight seal.
10. Replace the stainless steel collar, making sure to align it with the Allen screws
while keeping the glass surface flush with the collar.
11. Replace all six nuts and adjust them manually until they touch the housing.
12. Tighten the nuts uniformly by alternating between opposite nuts.
13. Reattach the produ c t to the installation sleeve by turning the Allen bolts clockwise.
You should only need a turn or two to have the stainless steel collar firmly attached.
6 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 11
Make sure to connect the
Ilumipod Inground IP product to a power line with the proper voltage and frequency, as per the specifications in this manual or on the product’s sticker.
The listed current rating indicates the
maximum current draw during normal operation.
Always connect the Ilumipod
Inground IP products to protected circuits (CB or fuse) with an appropriate electrical ground to avoid the risk of electrocution or fire.
Never connect an
Ilumipod Inground
IP product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Make sure to use
power and signal
cables with the indicated outer diameters to ensure that the corresponding gland nut makes full contact with the cable’s external insulation. This is required to keep the product’s IP67 rating when fully adjusted.
AC Power
Input Voltage and Frequency
The products in the Ilumipod Inground IP Series have an auto-ranging power supply with an input voltage range of 100~240 VAC, 50/60 Hz.
Power Consumption
To determine the power requirements for any of the Ilumipod Inground IP products see the label affixed to the side of the product. Alternatively, you may refer to the corresponding specifications chart in the Technical Information chapter of this manual.
Junction Box Wiring
The Ilumipod Inground IP products have an IP67 rated junction box where the power and signal cables come into the unit. The cables access the junction box through individual (signal and power) IP67 rated stainless steel gland nuts.
Make sure that the junction seal is clean before placing the cover back on. In additio n, tighten the gland nuts and the junction cover to prevent water from entering the junction box and causing a short.
The figure below shows the connections in the junction box.
Power Wiring
To provide AC power for any of the Ilumipod Inground IP products, you must run a single SJTW rated 3­conductor cable (AWG18/3, 6~8 mm external diameter) from the power distribution box into the installation sleeve and the product’s junction box.
Strip the end of the AC power cable that will connect to the junction box as indicated in the figure on the right.
Connection Wire (US) Wire (Europe)
Live Black Brown Neutral White Blue Ground Green/Yellow Green/Yellow
AC Power Input Wiring
Installation
Ilumipod Inground IP Series User Manual (Rev. 02) 7
Page 12
Installation
(
)
The signal cable must match or exceed the
electrical characteristics of the Belden® 9841 cable for EIA RS-485 applications. You can also use CAT 5, CAT 5e, or CAT 6.
If you choose to
bury the power or
signal distribution boxes, make sure that they are IP67 rated.
Signal Wiring
To provide signal for any of the Ilumipod Inground IP products, you must run a single, IP67 rated DMX signal cable (shielded, 2-conductor, AWG24/2, 6.5 mm external diameter) from the signal distribution box into the installation sleeve and the product’s junction box.
External Wiring
You must run AC power and signal wires from the respective AC and signal distribution boxes into each of the Ilumipod Inground IP products.
Power Distribution
Connect the bare-ended power cable from the product to a power distribution box as indicated below.
Signal Distribution
Connect the bare-ended signal cable from the product to a signal distribution box as indicated below.
Black
8 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 13
If you have not
configured the
DMX starting
address and DMX mode for each product, they will all use their default values. This means that all products will operate in unison.
Refer to the
Operation chapter
to learn how to
enable the Ilumipod Inground IP products to operate with the ILUMICON controller.
Controllers
The products in the Ilumipod Inground IP Series can operate with a standard DMX controller, the ILUMICON controller, or the Ilumicode controller. The sections below will show you how to connect these products to the corresponding controllers. The instructions to operate these products with each of the above controllers are in the Operation chapter of this manual.
DMX Controller
The Ilumipod Inground IP products can work with a standard DMX controller. The channel assignments will depend on the selected personality (refer to the Menu Map on pages 11 and
12) and the DMX address assigned to each product (refer to Programming on page 13). The figure below illustrates how to connect the DMX controller to the Ilumipod Inground IP
products.
ILUMICON
The Ilumipod Inground IP products can also work with the ILUMICON controller instead of a standard DMX controller. Please refer to the ILUMICON User Manual to learn how to use this controller with the Ilumipod Inground IP products.
The figure below illustrates how to connect the ILUMICON controller to the Ilumipod Inground IP products.
Installation
Ilumipod Inground IP Series User Manual (Rev. 02) 9
Page 14
Installation
To assign
individual DMX
addresses to
each product, you must connect the Ilumicode controller individually to each product.
ILUMINARC®
suggests that you
connect no more
than 20 products in this mode and keep the total distance to less than 60 m (197 ft). Otherwise, you might need to use an optically isolated signal amplifier.
Ilumicode
The diagram below shows how to connect the Ilumicode to this product. Note that this connection will control multiple products at the same time, all having the same
DMX address.
10 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 15
4. Operation
many of them that do not correspond with this menu map. Skip them, as they do not work with the White output products.
When you scroll through the menu options, you will see
If you scroll after STRB, you will see the
RED,
GREN, BLUE,
and AMBE
skip them as they do not work with the VW products.
colors. Just
Ilumicode
The products in the Ilumipod Inground IP Series lack a control panel. Therefore, they need an external controller, the Ilumicode device, to change their configuration.
Ilumicode Panel Description
Button Function
<MENU>
<ENTER>
<UP>
<DOWN>
<POWER>
Exits from the current menu or function Enables the currently displayed menu or sets the
currently selected value into the selected function Navigates upwards through the menu list and increases
the numeric value when in a function Navigates downwards through the menu list and
decreases the numeric value when in a function Turns the unit on. The unit will turn off automatically
after 30 seconds of inactivity.
Menu Map
The products in the Ilumipod Inground IP Series have distinct menu maps based on the colors they produce, whether RGB or White. The Ilumicode controller presents the functions for both types of products.
White Functions Menu Map
(Ilumipod Inground 36 IP VW)
This menu map shows you which parameters of the Ilumicode controller correspond to the Ilumipod Inground 36 IP VW product.
Operation
Ilumipod Inground IP Series User Manual (Rev. 02) 11
Page 16
Operation
many of them that do not correspond with this menu map. Skip them, as they do not work with the RGB only output products.
WARM colors. Just skip them as they do not work with the RGB products.
When you scroll through the menu options, you will see
If you scroll after STRB, you will see the AMBE,
COOL and
RGB Functions Menu Map
(Ilumipod Inground 36 IP RGB and Ilumipod Inground Tri-12 IP)
12 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 17
Make sure to press <ENTER>
after selecting an option. Otherwise, the product will not save the new setting. In this case, the Ilumicode’s display will show “SEND…”
The DMX Starting Address setting works with all but the REMOTE
personality.
Operation
Programming
Carry out all the programming procedures indicated below from Ilumicode’s panel. Refer to the corresponding Menu Map (pages 11 and 12) to learn how the menu options relate to each other depending on the type of product.
Use <ENTER> and <MENU> to change levels in the Menu Map. This is equivalent to moving right and left respectively. Use <UP> and <DOWN> to move forward and backwards respectively within the Menu Map options.
Press <ENTER> to accept the selected value for an option. This will send that value to the product(s).
DMX Personality
(All Ilumipod Inground IP products)
1. Go to PERSON and select any DMX personality that matches the product with
which you are working (ignore any other options).
36 IP RGB & Tri-12 IP 36 IP VW
ARC1
ARC+D
ARC FULL
SOLID SOLID
SPECIAL1
VW VW+D
2. Mak e sure to arrange the DMX addresses of all products in the current DMX
universe to avoid address overlapping.
DMX Starting Address
(All Ilumipod Inground IP products)
1. Go to DMX.
2. Select a starting DMX address (001~512).
Dimmer
(All Ilumipod Inground IP products)
1. Go to DIMMER.
2. Select a dimmer curve (OFF or DIM1~4).
Ilumipod Inground IP Series User Manual (Rev. 02) 13
DIMMER Description
OFF DIM1 DIM2 DIM3 DIM4
Dimmer curve is linear with fader
Non-linear (fastest)
Non-linear (fast)
Non-linear (slow)
Non-linear (slowest)
Page 18
Operation
Do not connect any other
controller to the product(s) when using the ILUMICON controller.
WHITE 1~11
define the white
color shown
when selecting a value 201~255 in channel 5 for the ARC FULL personality.
RGBTOW
defines the white
color shown
when the COLOR value is set to RGBTOW.
ILUMICON Control
(Only for 36 IP RGB and Tri-12 IP)
1. Go to PERSON.
2. Select the REMOTE personality.
Static Color
(Only for 36 IP RGB and Tri-12 IP)
1. Go to STATIC.
2. Select a color (RED, GREN, or BLUE).
3. Select a color value (000~255).
4. Select STRB.
5. Select a strobe frequency (0~20).
(Only for 36 IP VW)
1. Go to STATIC.
2. Select a color (COOL or WARM).
3. Select a color value (000~255).
Color Calibration
(Only for 36 IP RGB and Tri-12 IP)
1. Go to CALIB
2. Select a white color (WHITE 1~11) or RGBTOW.
3. Select an RGB color (RED, GREN, or BLUE).
4. Select a color value (0~255).
5. Repeat steps 3 and 4 for the other RGB colors to obtain a white color.
6. Repeat steps 2 to 5 fo r the other white colors.
Color
(Only for 36 IP RGB and Tri-12 IP)
1. Go to SETTINGS > COLOR.
2. Select the color method (OFF, RGBTOW, or UC).
Color Description
OFF
RGBTOW
UC
When the RGB faders are all at “255”, the output is at its maximum. When the RGB faders are all at “255”, the output is the selected white color (see Color Calibration). When the RGB faders are all at “255”, the output matches the same color output of previous versions of this product.
Reset
(Only for 36 IP RGB and Tri-12 IP)
1. Go to SETTINGS > RESET TO FACTORY SETTINGS.
2. Select an option (YES/NO).
14 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 19
DMX Values
ARC 1
Channel Function Value Percent/Setting
1 Red 2 Green 3 Blue
ARC 1 + D
Channel Function Value Percent/Setting
1 Dimmer 2 Red 3 Green 4 Blue
ARC FULL
Channel Function Value Percent/Setting
1 Dimmer 2 Red 3 Green 4 Blue
5 Color Macro + White Balance
6 Strobe
7 Dimming Speed
000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100%
000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100%
000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100% 000 010
011 030 031 050 051 070 071 090 091 110 111 130 131 150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255
000 004 005 255
000 009 010 029 030 069 070 129 130 189 190 255
No Function Red 100% - Green Up - Blue 0% Red Down - Green 100% - Blue 0% Red 0% - Green 100% - Blue Up Red 0% - Green Down - Blue 100% Red Up - Green 0% - Blue 100% Red 100% - Green 0% - Blue Down Red 100% - Green Up - Blue Up Red Down - Green Down - Blue 100% Red 100% - Green 100% - Blue 100% White 1: 3,200 K White 2: 3,400 K White 3: 4,200 K White 4: 4,900 K White 5: 5,600 K White 6: 5,900 K White 7: 6,500 K White 8: 7,200 K White 9: 8,000 K White 10: 8,500 K White 11: 10,000 K
No Function 0 ~ 20 Hz
Dimmer is set by Ilumicode OFF (Dimmer is linear) DIM1 (Fastest dimmer curve) DIM2 DIM3 DIM4 (Slowest dimmer curve)
Operation
Ilumipod Inground IP Series User Manual (Rev. 02) 15
Page 20
Operation
SPECIAL 1
Channel Function Value Percent/Setting
1 Module 1 Red 2 Module 1 Green 3 Module 1 Blue 4 Module 2 Red 5 Module 2 Green 6 Module 2 Blue
000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100%
VW
Channel Function Value Percent/Setting
1 Warm White 2 Cool White
000 255 0 ~ 100% 000 255 0 ~ 100%
VW + D
Channel Function Value Percent/Setting
1 Dimmer 2 Warm White 3 Cool White
000 255 0 ~ 100% 000 255 0 ~ 100% 000 255 0 ~ 100%
SOLID
Channel Function Value Percent/Setting
1 Dimmer
000 255 0 ~ 100%
16 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 21
5. Technical Information
cleaning them.
trying the solutions in the Troubleshooting Guide, contact ILUMINARC Technical Support.
Always dry the optic surfaces carefully after
If you still experience technical problems after
®
Product Maintenance
To maintain optimum performance and minimize wear, the user should clean the Ilumipod Inground IP products frequently. Usage and environment are contributing factors in determining the cleaning frequency. As a rule, the user should clean the product at least twice a month. Dust and grime build up on the glass surface reducing light output performance.
To clean an Ilumipod Inground IP product, follow the below recommendations:
1. D isconnect the power to the product.
2. W a it until the product is cold.
3. Loo s en the Allen bolts on the stainless steel collar by turning them CCW, not more
than a turn or two, enough to release the aluminum latch from its “locked” position.
4. Pu ll the product out of the installation sleeve, making sure that you are not pulling the
signal or AC power cables.
5. Use a wet vacuum cleaner to remove any liquid inside the installation sleeve and
around the product’s housing.
6. Inspect the cables and the gland nuts for signs of deterioration.
7. Clean or unclog the water drainage.
8. Replace the product in the installation sleeve.
9. Reattach the product to the installation sleeve by turning the Allen bolts CW. You
should only need a turn or two to have the stainless steel collar firmly attached.
10. Clean the glass surface with a mild solution of glass cleaner or isopropyl alcohol, and a
soft, lint free cotton cloth or a lens cleaning tissue to remove grease or grime.
11. Apply the solution directly to the cloth or tissue and drag any dirt and grime to the
outside of the lens.
12. Gently po lish the external glass surface until it is free of haze and lint.
Product Repairs
ILUMINARC® strongly advises you against attempting any repairs to this product unless you are an authorized ILUMINARC
®
ILUMINARC
presents the information contained in the Troubleshooting Table as a guide
only. In most cases, opening the product’s housing will invalidate its warranty, unless there is a written indication to the contrary.
®
technician.
Technical Information
Ilumipod Inground IP Series User Manual (Rev. 02) 17
Page 22
Technical Information
Troubleshooting Guide
Symptom Cause(s) Action(s)
Dimmer fader set to “0” Increase the value of the dimmer channel All color faders set to “0” Increase the value of the color channels All colors in STATIC are set to “0” Increase the values of the colors
Product does not light up
One LEDs does not work
Two or more LEDs do not work on a single module
The wrong LEDs light up when using DMX
Circuit breaker/fuse keeps tripping/blowing
Product does not respond to DMX
DMX signal problems
Unit is being configured with Ilumicode Complete the configuration process. No power Verify external power circuit and wiring Faulty internal power supply Change power supply Faulty main control board Change main control board Faulty LED Faulty LED module
Change LED module
Faulty LED driver Change LED driver Faulty LED module Change LED module Faulty LED driver Change LED driver Wrong personality Change the personality Wrong DMX address Change the DMX address Excessive circuit load Check total load on electrical circuit Short circuit along the power wires Check for a short in the electrical wiring Wrong DMX addressing Change DMX address Damaged DMX cables Check DMX cables
Wrong polarity on the controller
Check polarity switch settings on the
controller Loose DMX cables Check cable connections Faulty DMX interface Faulty Display/Main board
Replace the main control board Non DMX cables Use only DMX compatible cables
Unstable control signals Install terminator as su ggested Long cable / low level signal
Too many products
Interference from AC wires
Install an optically coupled DMX splitter
right after the product with the strong signal
Install an optically coupled DMX splitter
after unit #32 or before
Keep DMX cables separated from power
cables or fluorescent/black lights
18 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 23
Exploded View
Reference Description
1 2 3 4 5 6 7 8
9 10 11
Stainless steel cover 15 mm tempered glass Diaphragm LED lens panels LED boards Heat sink Power supply Control board Inner housing Installation sleeve Dustproof board
Technical Information
Ilumipod Inground IP Series User Manual (Rev. 02) 19
Page 24
Technical Information
V
Photometrics Pro 1.3.2 copyright 2003-
2008 by jSolutions, Inc. Reported data calculated from manufacturer's data file, based on IES recommended methods
Photometrics
Flood Summary
Illuminance at a Distance
.
Ilumipod Inground 36 IP 15º VW
Filename:
Manufacturer:
Luminaire:
Lamp Output:
Max Candela:
Input Wattage:
Luminous Opening:
Test Lab:
Photometry :
CIE Class:
Cutoff Class:
Field (10%): Beam (50%): Total:
Distance
(ft)
3 907.01 0.7 0.7 6 226.75 1.4 1.4
9 100.78 2.1 2.1 12 56.69 2.8 2.8 15 32.28 3.5 3.4 18 25.19 4.2 4.1
Vertical Spread
Ilumipod Inground 36 IP Optic 15 RGB 100% ALL ILUMINARC Ilumipod Inground 36 IP Optic 15 RGB
Lamp:
12 Red, 12 Green, 12 Blue 1 lamp(s), rated Lumens/lamp: 1380 8,753.5 at Horizontal: 180, Vertical: 3
43.1 Point
Test:
2009 ALL Iluminarc R & D Optics Laboratory Type B Direct Full Cutoff
Efficiency Lumens Horizontal Spread Vertical Spread
40.3% 556.6 28 28
17.7% 244.3 13.1 13.4
55.7% 768.1
Center Beam
(fc)
ertical Beam Width
13.4º
Horizontal Beam Width
(ft)
Horizontal Spread
(ft)
13.1º
20 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 25
V
jSolutions, Inc. Reported data calculated from manufacturer's data file, based on IES recommended methods
Photometrics Pro 1.3.2 copyright 2003­2008 by
.
Ilumipod Inground 36 IP 30º VW
Filename:
Manufacturer:
Luminaire:
Lamp Output:
Max Candela:
Input Wattage:
Luminous Opening:
Test Lab:
Photometry :
CIE Class:
Cutoff Class:
Flood Summary
Field (10%): Beam (50%): Total:
Illuminance at a Distance
Distance
(ft)
3 392.70 1.4 1.4
6 98.18 2.8 2.8
9 43.63 4.2 4.2 12 24.54 5.7 5.6 15 15.71 7.1 7.1 18 10.91 8.5 8.5
Vertical Spread
Ilumipod Inground 36 IP Optic 30 VW 100% ALL ILUMINARC Ilumipod Inground 36 IP Optic 30 VW
Lamp:
24 Warm White, 12 Cool White 1 lamp(s), rated Lumens/lamp: 3000 3,534.3 at Horizontal: 0, Vertical: 0
46.5 Point
Test:
2009 ALL Iluminarc R & D Optics Laboratory Type B Direct Full Cutoff
Efficiency Lumens Horizontal Spread Vertical Spread
27.3% 819.3 52.2 52.7
13.8% 413.5 26.5 26.6
32.8% 985.2
Center Beam
(fc)
ertical Beam Width
26.6º
Technical Information
Horizontal Beam Width
(ft)
Horizontal Spread
(ft)
26.5º
Ilumipod Inground IP Series User Manual (Rev. 02) 21
Page 26
Technical Information
V
Photometrics Pro
1.3.2 copyright 2003-2008 by
jSolutions, Inc. Reported data calculated from manufacturer's data file, based on IES recommended methods
Flood Summary
Illuminance at a Distance
.
Ilumipod Inground 36 IP 15º RGB
Filename:
Manufacturer:
Luminaire:
Lamp Output:
Max Candela:
Input Wattage:
Luminous Opening:
Test Lab:
Photometry :
CIE Class:
Cutoff Class:
Field (10%): Beam (50%): Total:
Distance
(ft)
3 907.01 0.7 0.7 6 226.75 1.4 1.4
9 100.78 2.1 2.1 12 56.69 2.8 2.8 15 36.28 3.5 3.4 18 25.19 4.2 4.1
Vertical Spread
Ilumipod Inground 36 IP Optic 15 RGB 100% ALL ILUMINARC Ilumipod Inground 36 IP Optic 15 RGB
Lamp:
12 Red, 12 Green, 12 Blue 1 lamp(s), rated Lumens/lamp: 1380 8,753.5 at Horizontal: 180, Vertical: 3
43.1 Point
Test:
2009 ALL Iluminarc R & D Optics Laboratory Type B Direct Full Cutoff
Efficiency Lumens Horizontal Spread Vertical Spread
40.3% 556.6 28 28
17.7% 244.3 13.1 13.4
55.7% 768.1
Center Beam
(fc)
ertical Beam Width
13.4º
Horizontal Beam Width
(ft)
Horizontal Spread
(ft)
13.1º
22 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 27
V
jSolutions, Inc. Reported data calculated from manufacturer's data file, based on IES recommended methods
Photometrics Pro 1.3.2 copyright 2003­2008 by
.
Ilumipod Inground 36 IP 30º RGB
Filename:
Manufacturer:
Luminaire:
Lamp Output:
Max Candela:
Input Wattage:
Luminous Opening:
Test Lab:
Photometry :
CIE Class:
Cutoff Class:
Flood Summary
Field (10%): Beam (50%): Total:
Illuminance at a Distance
Distance
(ft)
3 277.84 1.5 1.5
6 69.46 3.1 3.0
9 30.87 4.6 4.5 12 17.36 6.2 6.0 15 11.11 7.7 7.6 18 7.72 9.3 9.1
Vertical Spread
Ilumipod Inground 36 IP Optic 30 RGB 100% ALL ILUMINARC Ilumipod Inground 36 IP Optic 30 RGB
Lamp:
12 Red, 12 Green, 12 Blue 1 lamp(s), rated Lumens/lamp: 1380 2,520.5 at Horizontal: 0, Vertical: 3
43.3 Point
Test:
2009 ALL Iluminarc R & D Optics Laboratory Type B Direct Full Cutoff
Efficiency Lumens Horizontal Spread Vertical Spread
48.7% 672.7 55.4 55.2
25.6% 352.8 28.3 28.8
56.8% 784.4
Center Beam
(fc)
ertical Beam Width
28.4º
Technical Information
Horizontal Beam Width
(ft)
Horizontal Spread
(ft)
28.3º
Ilumipod Inground IP Series User Manual (Rev. 02) 23
Page 28
Technical Information
V
Photometrics Pro 1.3.2 copyright 2003-
2008 by jSolutions, Inc. Reported data calculated from manufacturer's data file, based on IES recommended methods
Flood Summary
Illuminance at a Distance
.
Ilumipod Inground Tri-12 IP 16º
Filename:
Manufacturer:
Luminaire:
Lamp Output:
Max Candela:
Input Wattage:
Luminous Opening:
Test Lab:
Photometry :
CIE Class:
Cutoff Class:
Field (10%): Beam (50%): Total:
Distance
(ft)
3 625.96 1.0 1.0 6 156.49 1.9 1.9
9 69.55 2.9 2.9 12 39.12 3.9 3.9 15 25.04 4.9 4.8 18 17.39 5.8 5.8
Vertical Spread
Ilumipod Inground Tri-12 IP Optic 16 RGB 100% ALL ILUMINARC Ilumipod Inground Tri-12 IP Optic 16 RGB
Lamp:
12 Tri-color 1 lamp(s), rated Lumens/lamp: 1380 5,633.6 at Horizontal: 0, Vertical: 0
17.6 Point
Test:
2009 ALL Iluminarc R & D Optics Laboratory Type B Direct Full Cutoff
Efficiency Lumens Horizontal Spread Vertical Spread
42.2% 583.0 33.7 34.2
21.4% 295.3 18.3 18.4
49.2% 679.1
Center Beam
(fc)
ertical Beam Width
18.4º
Horizontal Beam Width
(ft)
Horizontal Spread
(ft)
18.3º
24 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 29
LED Disclaimer
LED Life
ILUMINARC® rates LED lifetime based on lumen depreciation of 70% of the original output, with data provided by the manufacturer of the LED. Data from the manufacturer of the LED are not independently verified or measured by ILUMINARC®. When the product is operating in optimal environmental conditions, the LED lifetime is rated to be 50,000 to 70,000 hours by the LED manufacturer.
LED Binning
LED manufacturers sort LEDs into “bins”, based on variances in color, output intensity, and the frequency at which the semiconductor operates. ILUMINARC® strives to hold its LED manufacturers to the highest standards of binning to optimize consistency in output from product to product. However, the availability of a single bin cannot be guaranteed . With that in mind, ILUMINARC® has developed a rigorous control system to seek the best achievable consistency in color and output.
Color Rendering Index (CRI)
CRI is an industry standard method to compare properties of different types of light sources. There are known limitations and inconsistencies related to CRI. Results may vary depending on the environmental factors involved. For this reason, the US Department of Energy (DOE) states that CRI should be considered as one point of reference among others in evaluating white LED products and systems.
The following is an excerpt of recommendations from the DOE:
1. Id entify the visual tasks to be performed under the light source. If color fidelity
under different light sources is critically important (for example in a space where color or fabric comparisons are made under both daylight and electric lighting), CRI values may be a useful metric for rating LED products.
2. CRI may be compared only for light sources of equal CCT. This ap plies to all light
sources, not only to LEDs. Also, differences in CRI values of less than five points are not significant, e.g., light sources with 80 and 84 CRI are essentially the same.
3. If co lor appearance is more important than color fidelity, do not exclude white light
LEDs solely on the basis of relatively low CRI values. Some LED products with CRIs as low as 25 still produce visually pleasing white light.
4. Evaluate LED systems in person and, if possible, on-site when color fidelity or
color appearance are important issues.
Source: DOE publication: PNNL-SA-56891, January 2008
Technical Information
Ilumipod Inground IP Series User Manual (Rev. 02) 25
Page 30
Technical Information
write it on a properly affixed label.
repair or replace returned product(s).
will need those to ship the unit back to ILUMINARC
DO NOT write the RMA # directly on the box. Instead,
ILUMINARC reserves the right to use its own discretion to
Always keep the original box and all packaging material as you
®.
®
Returns Procedure
The user must send the merchandise prepaid, in the original box, and with its original packing and accessories. ILUMINARC
Call ILUMINARC shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return.
The user must clearly label the package with a Return Merchandise Authorization Number (RMA #). ILUMINARC
Once you receive the RMA #, please include the following information on a piece of paper inside the box:
Your name Your address Your phone number The RMA # A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be the customer’s responsibility. As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Claims
The carrier is responsible for any damage incurred during shipping. Therefore, if the received merchandise appears to have damages caused during shipping, the customer must submit the damage report and any related claims with the carrier, not ILUMINARC submit the report upon reception of the damaged merchandise. Failure to do so in a timely manner may invalidate the customer’s claim with the carrier.
For other issues such as missing components or parts, damage not related to shipping, or concealed damage, the customer must make claims to ILUMINARC receiving the merchandise.
Contact Us
®
will not issue call tags.
®
and request a Return Merchandise Authorization Number (RMA #) before
®
will refuse any product returned without the RMA #.
®
. The customer must
®
within seven (7) days of
World Wide
General Information
ILUMINARC® 5200 NW 108th Ave nue Sunrise, FL 33351
Voice: (954) 923-3680 Fax: (954) 929-5571 Email: info@iluminarc.com
Customer Support
Voice: (954) 923-3680 (ext. 4000) Fax: (954) 756-8015
Email: tech@iluminarc.com
World Wide Web
www.iluminarc.com
26 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 31
Technical Specifications
Ilumipod Inground 36 IP VW
Weight & Dimensions
Diameter ................................................................................................................. 12.6 in (320 mm)
Height ....................................................................................................................... 5.7 in (146 mm)
Weight ........................................................................................................................ 17.6 lbs (8 kg)
Power
Auto-ranging .............................................................................................. 100~240 VAC, 50/60 Hz
Power consumption @ 120 V ....................................................................................... 38 W (0.6 A)
Power consumption @ 230 V ....................................................................................... 40 W (0.3 A)
Inrush current .................................................................................... 0.1 A @ 120 V, 0.3 A@ 230 V
Power connectors ..................................................................... Terminal strip in sealed junction box
Light Source
Type .................................................................................................. 1 W, 350 mA 50,000 hrs LEDs
Configuration ........................................................... 36 LEDs (12 Cool White and 24 Warm White)
Construction
Housing ............................................................... Cast aluminum body and stainless steel outer ring
Color ............................................................................................... Black body and silver outer ring
Lens cover .................................................................................... Impact resistant (drive over rated)
Ingress protection (IP) rating ...................................................................................................... IP67
Photometrics
Installed optics: ............................................................................................................................. 15º
Beam angle: ............................................................................................................................... 13.1º
Field angle: ................................................................................................................................ 28.0º
Illuminance: ............................................................................................................. 226.75 fc @ 6 ft
Thermal
Maximum ambient temperature .................................................................................. 104° F (40° C)
Cooling ................................................................................................................ Natural convection
Control & Programming
Addresser ........................................................................................................................... Ilumicode
Data input ................................................................................ Terminal strip in sealed junction box
Data pin configuration ...................................................................... Pin 1 shield, pin 2 (-), pin 3 (+)
Protocols ............................................................................................................. USITT DMX512-A
DMX Channels .................................................................................................................... 1, 2, or 3
Ordering Information
Ilumipod Inground 36 IP Optic 15º VW ............................................................................. 11036010
Ilumipod Inground 36 IP Optic 30º VW ............................................................................. 11036008
Warranty Information
Warranty ....................................................................................................... 2-year limited warranty
Technical Information
Ilumipod Inground IP Series User Manual (Rev. 02) 27
Page 32
Technical Information
Ilumipod Inground 36 IP RGB
Weight & Dimensions
Diameter ................................................................................................................. 12.6 in (320 mm)
Height ....................................................................................................................... 5.7 in (146 mm)
Weight ........................................................................................................................ 17.6 lbs (8 kg)
Power
Auto-ranging .............................................................................................. 100~240 VAC, 50/60 Hz
Power consumption @ 120 V ....................................................................................... 38 W (0.6 A)
Power consumption @ 230 V ....................................................................................... 40 W (0.3 A)
Inrush current .................................................................................... 0.1 A @ 120 V, 0.3 A@ 230 V
Power connectors ..................................................................... Terminal strip in sealed junction box
Light Source
Type .................................................................................................. 1 W, 350 mA 50,000 hrs LEDs
Configuration ................................................................... 36 LEDs (12 Red, 12 Green, and 12 Blue)
Construction
Housing................................................................ Cast aluminum body and stainless steel outer ring
Color ............................................................................................... Black body and silver outer ring
Lens cover .................................................................................... Impact resistant (drive over rated)
Ingress protection (IP) rating ...................................................................................................... IP67
Photometrics
Installed optics: ............................................................................................................................. 15º
Beam angle: ............................................................................................................................... 13.1º
Field angle: ................................................................................................................................ 40.3º
Illuminance: ............................................................................................................. 226.75 fc @ 6 ft
Thermal
Maximum ambient temperature .................................................................................. 104° F (40° C)
Cooling ................................................................................................................ Natural convection
Control & Programming
Addresser ........................................................................................................................... Ilumicode
Data input ................................................................................ Terminal strip in sealed junction box
Data pin configuration ...................................................................... Pin 1 shield, pin 2 (-), pin 3 (+)
Protocols ............................................................................................................. USITT DMX512-A
DMX Channels ............................................................................................................ 1, 3, 4, 6, or 7
Ordering Information
Ilumipod Inground 36 IP Optic 15º RGB........................................................................... 11036009
Ilumipod Inground 36 IP Optic 30º RGB........................................................................... 11036007
Warranty Information
Warranty ....................................................................................................... 2-year limited warranty
28 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 33
Ilumipod Inground Tri-12 IP
Weight & Dimensions
Diameter ................................................................................................................. 12.6 in (320 mm)
Height ....................................................................................................................... 5.7 in (146 mm)
Weight ........................................................................................................................ 17.6 lbs (8 kg)
Power
Auto-ranging .............................................................................................. 100~240 VAC, 50/60 Hz
Power consumption @ 120 V ....................................................................................... 38 W (0.6 A)
Power consumption @ 230 V ....................................................................................... 40 W (0.3 A)
Inrush current .................................................................................... 0.1 A @ 120 V, 0.3 A@ 230 V
Power connectors ..................................................................... Terminal strip in sealed junction box
Light Source
Type ................................................................................ 3 W, 1,050 mA 50,000 hrs Tri-color LEDs
Configuration ........................................................................................................ 12 Tri-color LEDs
Construction
Housing ............................................................... Cast aluminum body and stainless steel outer ring
Color ............................................................................................... Black body and silver outer ring
Lens cover .................................................................................... Impact resistant (drive over rated)
Ingress protection (IP) rating ...................................................................................................... IP67
Photometrics
Installed optics: ............................................................................................................................. 16º
Beam angle: ............................................................................................................................... 18.3º
Field angle: ................................................................................................................................ 33.7º
Illuminance: ............................................................................................................. 156.49 fc @ 6 ft
Thermal
Maximum ambient temperature .................................................................................. 104° F (40° C)
Cooling ................................................................................................................ Natural convection
Control & Programming
Addresser ........................................................................................................................... Ilumicode
Data input ................................................................................ Terminal strip in sealed junction box
Data pin configuration ...................................................................... Pin 1 shield, pin 2 (-), pin 3 (+)
Protocols ............................................................................................................. USITT DMX512-A
DMX Channels ............................................................................................................ 1, 3, 4, 6, or 7
Ordering Information
Ilumipod Inground Tri-12 IP Optic 15º .............................................................................. 11012001
Warranty Information
Warranty ....................................................................................................... 2-year limited warranty
Technical Information
Ilumipod Inground IP Series User Manual (Rev. 02) 29
Page 34
ILUMINARC
5200 NW 108
®
th
Avenue Sunrise, FL 33351 U.S.A. Tel.: (954) 929-1115 FAX: (954) 929-5560 www.iluminarc.com
Ilumipod Inground IP Series User Manual Rev. 02 August 2011
Loading...