The Ilumipod Inground IP Series User Manual Rev. 01f covers the description, safety precautions, installation,
programming, operation, and maintenance of the Ilumipod Inground 36 IP RGB, Ilumipod Inground 36 IP VW,
and Ilumipod Inground Tri-12 IP products. ILUMINARC
User Manual Rev. 01f in July 2011.
®
released this edition of the Ilumipod Inground IP Series
Trademarks
The ILUMINARC® logo, the ILUMINARC® name, and all other trademarks in this document related to services
or products by ILUMINARC
Any other product names, logos, brands, company names, or trademarks featured or referred to within this
document are the property of their respective trademark holders.
®
are trademarks owned or licensed by ILUMINARC®, its affiliates, or subsidiaries.
Copyright Notice
The entire content of this document, except where applicable and unless otherwise noted, is solely owned by
ILUMINARC
ILUMINARC® authorizes its customers to download and print this manual for professional information purposes
only. ILUMINARC
manual or its content for any other purpose without its written consent.
®
expressly prohibits the usage, copy, storage, distribution, modification, or printing of this
Document Printing
For better results, print this document in color, on letter size paper (8.5 x 11 inches), double sided. If using A4
paper (210 x 297 mm), configure your printer to scale the content of this document to A4 paper.
Intended Audience
Any person in charge of installing, operating, and/or maintaining any of these products should read the Guide
that shipped with it and this manual in their entirety before installing, operating, or maintaining the product.
Disclaimer
ILUMINARC® believes that the information contained in this manual is accurate in all respects. However,
ILUMINARC
right to revise this document and to make changes from time to time in the content hereof without obligation of
ILUMINARC
a commitment by ILUMINARC
new edition of it to incorporate such changes.
®
assumes no responsibility for any error or omissions in this document. ILUMINARC® reserves the
®
to notify any person or company of such revision or changes. This does not constitute in any way
®
to make such changes. ILUMINARC® may issue a revision of this manual or a
ILUMINARC® Publications Hot Line
If you have any comments about the accuracy of this document or general suggestions regarding how we can
improve it, please call us at (954) 923-3680. You can download the latest versions of all ILUMINARC
manuals from www.iluminarc.com.
®
products’
Document Revision
The Ilumipod Inground IP Series User Manual Rev. 01f supersedes all previous versions of this manual. Please
discard any older versions of this manual you may have, whether in printed or electronic format, and replace
them with this version.
Ilumipod Inground 36 IP VW .............................................................................................. 27
Ilumipod Inground 36 IP RGB ............................................................................................ 28
Ilumipod Inground Tri-12 IP ............................................................................................... 29
ii Ilumipod Inground IP Series User Manual (Rev. 02)
Page 5
1. Introduction
This icon
indicates useful,
although non-
critical information.
This icon
indicates
important
installation or
configuration information.
Failure to comply with this
information may prevent
the product from
functioning correctly.
This icon
indicates critical
installation,
configuration, or operation
information. Failure to
comply with this
information may render
the product partially or
completely inoperative,
damage third-party
equipment, or cause harm
to the user
The term “DMX”
used throughout
this document
refers to the USITT
DMX512-A transmission
protocol.
What is in the Box
One Ilumipod Inground IP product (36 IP RGB, 36 IP VW, or Tri-12 IP)
Warranty Card
Quick Reference Guide
Unpacking Instructions
Immediately upon receiving a product from ILUMINARC®, carefully unpack the carton.
Check the contents of the box to ensure that all parts are present and that they are in good
condition. If any part appears damaged from shipping, or if the carton shows signs of
mishandling, see the Claims section in the Technical Information chapter.
Text Conventions
Convention Meaning
1~512
50/60
“ILUMICON UM”
<SET>
SETTINGS
MENU > SETTINGS
1~10
Yes/No
ON
A range of values in the text
A set of mutually exclusive values in the text
The name of another publication or manual
A button on the product’s control panel
A product function or a menu option
A sequence of menu options
A range of menu values from which to choose in a menu
A set of two mutually exclusive menu options in a menu
A unique value to enter or select in a menu
Introduction
Ilumipod Inground IP Series User Manual (Rev. 02) 1
regulations for the proper
installation of this product.
you sell this product to
another user, make sure
that they also receive this
manual.
Inground IP product may
require service, please
contact ILUMINARC
Technical Support.
There are no
user serviceable
parts inside this
®
Please refer to all
applicable local
codes and
Keep this manual
for future
consultation. If
In the unlikely
event that your
Ilumipod
authorized
®
Safety Notes
Please read all the following safety notes carefully because they include important information
on how to install, use, and maintain this product safely.
Personal Safety
Avoid direct eye exposure to the light source while the product is on.
Always disconnect the Ilumipod Inground IP product from its power source before
servicing.
Always connect the Ilumipod Inground IP product to a grounded circuit to avoid the risk
of electrocution.
Installing
The Ilumipod Inground IP products are for o utdoor use and they can work while
submerged in up to 1 m of water (IP67) for 30 min.
Observe the installation instructions regarding drainage to ensure that the water level is
never higher than 1 m to comply with the IP67 rating.
Power and Wiring
Always make sure that you are connecting this product to the proper voltage, as per the
specifications in this manual or on the product’s sticker.
Never connect this product to a dimmer pack.
Make sure that the power cable is not cracked, crimped, or damaged.
Make sure that the sealed cover is properly adjusted to avoid water entering the unit.
Operation
The maximum ambient temperature (Ta) is 104° F (40° C). Do not operate this product
at a higher temperature.
In case of a serious operating problem, stop using this product immediately!
2 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 7
2. Product Description
Product Description
Other than their
LED configuration
and programming
features, these
three products share the
same dimensions, as well
as the installation, wiring,
and troubleshooting
procedures.
The lenses in
these three
products are non-
changeable.
Therefore, make sure to
use the right product
order code for the desired
lens angle.
The Ilumipod Inground IP Series includes three separate products: Ilumipod Inground 36 IP
RGB, Ilumipod Inground 36 IP VW, and Ilu mipod Inground Tri-12 IP.
Common Features
Remotely addressable DMX-512 LED ingro un d wash light
IP67 ingress protection
IP67 stainless steel gland nuts for cable entry
Adjustable module angle
Cast aluminum and stainless steel housing
Impact resistant glass lens cover (drive-over rated)
Polished stainless steel mounting ring
Ilumicode compatible
ILUMICON compatible
High power 1 W (750 mA) Warm White and Cool White LEDs
Installed (non-changeable) optical system:
15 lenses Product order code: 11036010
30º lenses Product order code: 11036008
Ilumipod Inground 36 IP RGB Features
Operating modes:
1-channel: Dimmer
3-channel: RGB control
4-channel: RGB, dimmer
6-channel: RGB per module
7-channel: RGB, dimmer, macro, strobe, dimming speed
High power 1 W (750 mA) Red, Green, and Blue LEDs
Blackout/static/dimmer/strobe/pulse
Installed (non-changeable) optical system:
15 lenses Product order code: 11036009
30º lenses Product order code: 11036007
Ilumipod Inground Tri-12 IP Features
Operating modes:
High power 3 W (1,050 mA) tri-color LEDs
Blackout/static/dimmer/strobe/pulse
Installed (non-changeable) optical system:
Ilumipod Inground IP Series User Manual (Rev. 02) 3
1-channel: Dimmer
3-channel: RGB control
4-channel: RGB, dimmer
6-channel: RGB per module
7-channel: RGB, dimmer, macro, strobe, dimming speed
16 lenses Product order code: 11012001
Page 8
Product Description
Product Dimensions
(All Ilumipod Inground IP Series models)
4 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 9
3. Installation
Always keep the
power cables
away from the
signal cables by
running them in different
conduits and using
separate distribution
boxes.
Ilumipod Inground
IP products can
support a
distributed load of up to
3,000 kg (6,614 lbs) when
properly installed.
Installation Notes
The Ilumipod Inground IP products consist of two parts, the product housing and the concrete
installation sleeve. The product housing is IP67 rated, but the installation sleeve is not.
Carefully read the installation instructions for the concrete installation sleeve regard ing leve ling
and drainage.
You will have to run the AC power and signal cables in to the concrete installation sleeve and
the product’s housing.
Do not use the product’s junction box to extend the power or signal cables to other units
because it may compromise the IP rating of the junction box. Instead, use individual cables
from the product to the corresponding distribution boxes.
Installation Sleeve Orientation
Orient the installation sleeve to allow the signal cable to enter the sleeve using one of th e four
cable inlets and the power cable to use the opposite inlet, as seen in the following figure. This
will reduce the stress to the signal and power cables when setting down the product, while
keeping them separated under the product’s housing.
Installation Sleeve Setup
When setting up the installation sleeve, make sure any water that entered the sleeve can drain
out on its own. Locate the installation sleeve above the normal drainage level so the product
is never under more than 1 m of water (IP67) during heavy rain.
In addition, make sure that the installation sleeve and the stainless steel collar are horizontal
and even with the ground surface. This helps to distribute the load uniformly over the
product’s surface and avoids creating dangerous bumps.
Installation
Ilumipod Inground IP Series User Manual (Rev. 02) 5
Page 10
Installation
Make sure to
disconnect the
power to the
product before opening it.
Be careful when
opening and
closing the
product’s housing as it
may compromise the
product’s IP67 rating.
Beam Angle Adjustment
Ilumipod Inground IP products have two LED modules each. You can adjust the angle of
each of these modules to spread or narrow the product’s beam. Follow these steps:
1. Loo s en the Allen bolts on the stainless steel collar by turning no more than a turn
or two counter-clockwise to release the aluminum latch from its “locked” position.
2. Lift th e prod uct from the installation sleeve, making sure not to stretch the power
and signal cables.
3. Loosen four of the six nuts that hold the collar to the housing, leaving untouched
any two adjacent nuts.
4. W ait a few seconds for the seal to expand, which lowers the possibility of
damaging the seal.
5. Co mplete the removal of the two remaining nuts.
6. Re move the stainless steel collar.
7. Carefully lift and remove the protective glass and the attached seal, making sure
not to reverse the glass.
8. Using only your hands, push on the sides of each module to adjust its angle, as
shown in the figure below.
9. Replace the glass and then re-silicone the seal to insure a watertight seal.
10. Replace the stainless steel collar, making sure to align it with the Allen screws
while keeping the glass surface flush with the collar.
11. Replace all six nuts and adjust them manually until they touch the housing.
12. Tighten the nuts uniformly by alternating between opposite nuts.
13. Reattach the produ c t to the installation sleeve by turning the Allen bolts clockwise.
You should only need a turn or two to have the stainless steel collar firmly
attached.
6 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 11
Make sure to
connect the
Ilumipod Inground
IP product to a power line
with the proper voltage
and frequency, as per the
specifications in this
manual or on the
product’s sticker.
The listed
current rating
indicates the
maximum
current draw during
normal operation.
Always connect
the Ilumipod
Inground IP
products to protected
circuits (CB or fuse) with
an appropriate electrical
ground to avoid the risk of
electrocution or fire.
Never connect an
Ilumipod Inground
IP product to a
rheostat (variable resistor)
or dimmer circuit, even if
the rheostat or dimmer
channel serves only as a
0 to 100% switch.
Make sure to use
power and signal
cables with the
indicated outer diameters
to ensure that the
corresponding gland nut
makes full contact with
the cable’s external
insulation. This is required
to keep the product’s IP67
rating when fully adjusted.
AC Power
Input Voltage and Frequency
The products in the Ilumipod Inground IP Series have an auto-ranging power supply with an
input voltage range of 100~240 VAC, 50/60 Hz.
Power Consumption
To determine the power requirements for any of the Ilumipod Inground IP products see the
label affixed to the side of the product. Alternatively, you may refer to the corresponding
specifications chart in the Technical Information chapter of this manual.
Junction Box Wiring
The Ilumipod Inground IP products have an IP67 rated junction box where the power and signal
cables come into the unit. The cables access the junction box through individual (signal and
power) IP67 rated stainless steel gland nuts.
Make sure that the junction seal is clean before placing the cover back on. In additio n, tighten
the gland nuts and the junction cover to prevent water from entering the junction box and
causing a short.
The figure below shows the connections in the junction box.
Power Wiring
To provide AC power for any of the Ilumipod Inground
IP products, you must run a single SJTW rated 3conductor cable (AWG18/3, 6~8 mm external diameter)
from the power distribution box into the installation
sleeve and the product’s junction box.
Strip the end of the AC power cable that will connect to
the junction box as indicated in the figure on the right.
Connection Wire (US) Wire (Europe)
Live Black Brown
Neutral White Blue
Ground Green/Yellow Green/Yellow
AC Power Input Wiring
Installation
Ilumipod Inground IP Series User Manual (Rev. 02) 7
Page 12
Installation
(
)
The signal cable
must match or
exceed the
electrical
characteristics of the
Belden® 9841 cable for
EIA RS-485 applications.
You can also use CAT 5,
CAT 5e, or CAT 6.
If you choose to
bury the power or
signal distribution
boxes, make sure that
they are IP67 rated.
Signal Wiring
To provide signal for any of the Ilumipod Inground IP products, you must run a single, IP67
rated DMX signal cable (shielded, 2-conductor, AWG24/2, 6.5 mm external diameter) from
the signal distribution box into the installation sleeve and the product’s junction box.
External Wiring
You must run AC power and signal wires from the respective AC and signal distribution boxes
into each of the Ilumipod Inground IP products.
Power Distribution
Connect the bare-ended power cable from the product to a power distribution box as indicated
below.
Signal Distribution
Connect the bare-ended signal cable from the product to a signal distribution box as indicated
below.
Black
8 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 13
If you have not
configured the
DMX starting
address and DMX
mode for each product,
they will all use their
default values. This
means that all products
will operate in unison.
Refer to the
Operation chapter
to learn how to
enable the
Ilumipod Inground IP
products to operate with
the ILUMICON controller.
Controllers
The products in the Ilumipod Inground IP Series can operate with a standard DMX controller,
the ILUMICON controller, or the Ilumicode controller. The sections below will show you how
to connect these products to the corresponding controllers. The instructions to operate these
products with each of the above controllers are in the Operation chapter of this manual.
DMX Controller
The Ilumipod Inground IP products can work with a standard DMX controller. The channel
assignments will depend on the selected personality (refer to the Menu Map on pages 11 and
12) and the DMX address assigned to each product (refer to Programming on page 13).
The figure below illustrates how to connect the DMX controller to the Ilumipod Inground IP
products.
ILUMICON
The Ilumipod Inground IP products can also work with the ILUMICON controller instead of
a standard DMX controller. Please refer to the ILUMICON User Manual to learn how to use
this controller with the Ilumipod Inground IP products.
The figure below illustrates how to connect the ILUMICON controller to the Ilumipod
Inground IP products.
Installation
Ilumipod Inground IP Series User Manual (Rev. 02) 9
Page 14
Installation
To assign
individual DMX
addresses to
each product, you
must connect the
Ilumicode controller
individually to each
product.
ILUMINARC®
suggests that you
connect no more
than 20 products
in this mode and keep the
total distance to less than
60 m (197 ft). Otherwise,
you might need to use an
optically isolated signal
amplifier.
Ilumicode
The diagram below shows how to connect the Ilumicode to this product.
Note that this connection will control multiple products at the same time, all having the same
DMX address.
10 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 15
4. Operation
many of them that do not
correspond with this menu
map. Skip them, as they
do not work with the
White output products.
When you scroll
through the
menu options,
you will see
If you scroll after
STRB, you will
see the
RED,
GREN, BLUE,
and AMBE
skip them as they do not
work with the VW
products.
colors. Just
Ilumicode
The products in the Ilumipod Inground IP Series lack a control panel. Therefore, they need an
external controller, the Ilumicode device, to change their configuration.
Ilumicode Panel Description
Button Function
<MENU>
<ENTER>
<UP>
<DOWN>
<POWER>
Exits from the current menu or function
Enables the currently displayed menu or sets the
currently selected value into the selected function
Navigates upwards through the menu list and increases
the numeric value when in a function
Navigates downwards through the menu list and
decreases the numeric value when in a function
Turns the unit on. The unit will turn off automatically
after 30 seconds of inactivity.
Menu Map
The products in the Ilumipod Inground IP Series have distinct menu maps based on the colors they
produce, whether RGB or White. The Ilumicode controller presents the functions for both types of
products.
White Functions Menu Map
(Ilumipod Inground 36 IP VW)
This menu map shows you which parameters of the Ilumicode controller correspond to the
Ilumipod Inground 36 IP VW product.
Operation
Ilumipod Inground IP Series User Manual (Rev. 02) 11
Page 16
Operation
many of them that do not
correspond with this menu
map. Skip them, as they
do not work with the RGB
only output products.
WARM colors. Just skip
them as they do not work
with the RGB products.
When you scroll
through the
menu options,
you will see
If you scroll after
STRB, you will
see the AMBE,
COOL and
RGB Functions Menu Map
(Ilumipod Inground 36 IP RGB and Ilumipod Inground Tri-12 IP)
12 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 17
Make sure to
press <ENTER>
after selecting an
option. Otherwise, the
product will not save the
new setting. In this case,
the Ilumicode’s display
will show “SEND…”
The DMX Starting
Address setting
works with all but
the REMOTE
personality.
Operation
Programming
Carry out all the programming procedures indicated below from Ilumicode’s panel. Refer to the
corresponding Menu Map (pages 11 and 12) to learn how the menu options relate to each other
depending on the type of product.
Use <ENTER> and <MENU> to change levels in the Menu Map. This is equivalent to moving
right and left respectively. Use <UP> and <DOWN> to move forward and backwards
respectively within the Menu Map options.
Press <ENTER> to accept the selected value for an option. This will send that value to the
product(s).
DMX Personality
(All Ilumipod Inground IP products)
1. Go to PERSON and select any DMX personality that matches the product with
which you are working (ignore any other options).
36 IP RGB & Tri-12 IP 36 IP VW
ARC1
ARC+D
ARC FULL
SOLID SOLID
SPECIAL1
VW
VW+D
2. Mak e sure to arrange the DMX addresses of all products in the current DMX
universe to avoid address overlapping.
DMX Starting Address
(All Ilumipod Inground IP products)
1. Go to DMX.
2. Select a starting DMX address (001~512).
Dimmer
(All Ilumipod Inground IP products)
1. Go to DIMMER.
2. Select a dimmer curve (OFF or DIM1~4).
Ilumipod Inground IP Series User Manual (Rev. 02) 13
DIMMER Description
OFF
DIM1
DIM2
DIM3
DIM4
Dimmer curve is linear with fader
Non-linear (fastest)
Non-linear (fast)
Non-linear (slow)
Non-linear (slowest)
Page 18
Operation
Do not connect
any other
controller to the
product(s) when using the
ILUMICON controller.
WHITE 1~11
define the white
color shown
when selecting a
value 201~255 in channel
5 for the ARC FULL
personality.
RGBTOW
defines the white
color shown
when the COLOR
value is set to RGBTOW.
ILUMICON Control
(Only for 36 IP RGB and Tri-12 IP)
1. Go to PERSON.
2. Select the REMOTE personality.
Static Color
(Only for 36 IP RGB and Tri-12 IP)
1. Go to STATIC.
2. Select a color (RED, GREN, or BLUE).
3. Select a color value (000~255).
4. Select STRB.
5. Select a strobe frequency (0~20).
(Only for 36 IP VW)
1. Go to STATIC.
2. Select a color (COOL or WARM).
3. Select a color value (000~255).
Color Calibration
(Only for 36 IP RGB and Tri-12 IP)
1. Go to CALIB
2. Select a white color (WHITE 1~11) or RGBTOW.
3. Select an RGB color (RED, GREN, or BLUE).
4. Select a color value (0~255).
5. Repeat steps 3 and 4 for the other RGB colors to obtain a white color.
6. Repeat steps 2 to 5 fo r the other white colors.
Color
(Only for 36 IP RGB and Tri-12 IP)
1. Go to SETTINGS > COLOR.
2. Select the color method (OFF, RGBTOW, or UC).
Color Description
OFF
RGBTOW
UC
When the RGB faders are all at “255”, the output is at its
maximum.
When the RGB faders are all at “255”, the output is the
selected white color (see Color Calibration).
When the RGB faders are all at “255”, the output matches the
same color output of previous versions of this product.
Reset
(Only for 36 IP RGB and Tri-12 IP)
1. Go to SETTINGS > RESET TO FACTORY SETTINGS.
2. Select an option (YES/NO).
14 Ilumipod Inground IP Series User Manual (Rev. 02 )
No Function
Red 100% - Green Up - Blue 0%
Red Down - Green 100% - Blue 0%
Red 0% - Green 100% - Blue Up
Red 0% - Green Down - Blue 100%
Red Up - Green 0% - Blue 100%
Red 100% - Green 0% - Blue Down
Red 100% - Green Up - Blue Up
Red Down - Green Down - Blue 100%
Red 100% - Green 100% - Blue 100%
White 1: 3,200 K
White 2: 3,400 K
White 3: 4,200 K
White 4: 4,900 K
White 5: 5,600 K
White 6: 5,900 K
White 7: 6,500 K
White 8: 7,200 K
White 9: 8,000 K
White 10: 8,500 K
White 11: 10,000 K
No Function
0 ~ 20 Hz
Dimmer is set by Ilumicode
OFF (Dimmer is linear)
DIM1 (Fastest dimmer curve)
DIM2
DIM3
DIM4 (Slowest dimmer curve)
Operation
Ilumipod Inground IP Series User Manual (Rev. 02) 15
Page 20
Operation
SPECIAL 1
Channel Function Value Percent/Setting
1 Module 1 Red
2 Module 1 Green
3 Module 1 Blue
4 Module 2 Red
5 Module 2 Green
6 Module 2 Blue
16 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 21
5. Technical Information
cleaning them.
trying the solutions in the
Troubleshooting Guide,
contact ILUMINARC
Technical Support.
Always dry the
optic surfaces
carefully after
If you still
experience
technical
problems after
®
Product Maintenance
To maintain optimum performance and minimize wear, the user should clean the Ilumipod
Inground IP products frequently. Usage and environment are contributing factors in
determining the cleaning frequency. As a rule, the user should clean the product at least twice a
month. Dust and grime build up on the glass surface reducing light output performance.
To clean an Ilumipod Inground IP product, follow the below recommendations:
1. D isconnect the power to the product.
2. W a it until the product is cold.
3. Loo s en the Allen bolts on the stainless steel collar by turning them CCW, not more
than a turn or two, enough to release the aluminum latch from its “locked” position.
4. Pu ll the product out of the installation sleeve, making sure that you are not pulling the
signal or AC power cables.
5. Use a wet vacuum cleaner to remove any liquid inside the installation sleeve and
around the product’s housing.
6. Inspect the cables and the gland nuts for signs of deterioration.
7. Clean or unclog the water drainage.
8. Replace the product in the installation sleeve.
9. Reattach the product to the installation sleeve by turning the Allen bolts CW. You
should only need a turn or two to have the stainless steel collar firmly attached.
10. Clean the glass surface with a mild solution of glass cleaner or isopropyl alcohol, and a
soft, lint free cotton cloth or a lens cleaning tissue to remove grease or grime.
11. Apply the solution directly to the cloth or tissue and drag any dirt and grime to the
outside of the lens.
12. Gently po lish the external glass surface until it is free of haze and lint.
Product Repairs
ILUMINARC® strongly advises you against attempting any repairs to this product unless you
are an authorized ILUMINARC
®
ILUMINARC
presents the information contained in the Troubleshooting Table as a guide
only. In most cases, opening the product’s housing will invalidate its warranty, unless there is a
written indication to the contrary.
®
technician.
Technical Information
Ilumipod Inground IP Series User Manual (Rev. 02) 17
Page 22
Technical Information
Troubleshooting Guide
Symptom Cause(s) Action(s)
Dimmer fader set to “0” Increase the value of the dimmer channel
All color faders set to “0” Increase the value of the color channels
All colors in STATIC are set to “0” Increase the values of the colors
Product does not light up
One LEDs does not work
Two or more LEDs do not work
on a single module
The wrong LEDs light up when
using DMX
Circuit breaker/fuse keeps
tripping/blowing
Product does not respond to
DMX
DMX signal problems
Unit is being configured with Ilumicode Complete the configuration process.
No power Verify external power circuit and wiring
Faulty internal power supply Change power supply
Faulty main control board Change main control board
Faulty LED
Faulty LED module
Change LED module
Faulty LED driver Change LED driver
Faulty LED module Change LED module
Faulty LED driver Change LED driver
Wrong personality Change the personality
Wrong DMX address Change the DMX address
Excessive circuit load Check total load on electrical circuit
Short circuit along the power wires Check for a short in the electrical wiring
Wrong DMX addressing Change DMX address
Damaged DMX cables Check DMX cables
Replace the main control board
Non DMX cables Use only DMX compatible cables
Unstable control signals Install terminator as su ggested
Long cable / low level signal
Too many products
Interference from AC wires
Install an optically coupled DMX splitter
right after the product with the strong signal
Install an optically coupled DMX splitter
after unit #32 or before
Keep DMX cables separated from power
cables or fluorescent/black lights
18 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 23
Exploded View
Reference Description
1
2
3
4
5
6
7
8
9
10
11
Stainless steel cover
15 mm tempered glass
Diaphragm
LED lens panels
LED boards
Heat sink
Power supply
Control board
Inner housing
Installation sleeve
Dustproof board
Technical Information
Ilumipod Inground IP Series User Manual (Rev. 02) 19
Page 24
Technical Information
V
Photometrics
Pro 1.3.2
copyright 2003-
2008 by
jSolutions, Inc.
Reported data calculated
from manufacturer's data
file, based on IES
recommended methods
2009 ALL
Iluminarc R & D Optics Laboratory
Type B
Direct
Full Cutoff
EfficiencyLumensHorizontal Spread Vertical Spread
42.2% 583.0 33.7 34.2
21.4% 295.3 18.3 18.4
49.2% 679.1
Center Beam
(fc)
ertical Beam Width
18.4º
Horizontal Beam Width
(ft)
Horizontal Spread
(ft)
18.3º
24 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 29
LED Disclaimer
LED Life
ILUMINARC® rates LED lifetime based on lumen depreciation of 70% of the original
output, with data provided by the manufacturer of the LED. Data from the manufacturer of
the LED are not independently verified or measured by ILUMINARC®. When the product is
operating in optimal environmental conditions, the LED lifetime is rated to be 50,000 to
70,000 hours by the LED manufacturer.
LED Binning
LED manufacturers sort LEDs into “bins”, based on variances in color, output intensity, and
the frequency at which the semiconductor operates. ILUMINARC® strives to hold its LED
manufacturers to the highest standards of binning to optimize consistency in output from
product to product. However, the availability of a single bin cannot be guaranteed . With that
in mind, ILUMINARC® has developed a rigorous control system to seek the best achievable
consistency in color and output.
Color Rendering Index (CRI)
CRI is an industry standard method to compare properties of different types of light sources.
There are known limitations and inconsistencies related to CRI. Results may vary depending
on the environmental factors involved. For this reason, the US Department of Energy (DOE)
states that CRI should be considered as one point of reference among others in evaluating
white LED products and systems.
The following is an excerpt of recommendations from the DOE:
1. Id entify the visual tasks to be performed under the light source. If color fidelity
under different light sources is critically important (for example in a space where
color or fabric comparisons are made under both daylight and electric lighting),
CRI values may be a useful metric for rating LED products.
2. CRI may be compared only for light sources of equal CCT. This ap plies to all light
sources, not only to LEDs. Also, differences in CRI values of less than five points
are not significant, e.g., light sources with 80 and 84 CRI are essentially the same.
3. If co lor appearance is more important than color fidelity, do not exclude white light
LEDs solely on the basis of relatively low CRI values. Some LED products with
CRIs as low as 25 still produce visually pleasing white light.
4. Evaluate LED systems in person and, if possible, on-site when color fidelity or
color appearance are important issues.
Source: DOE publication: PNNL-SA-56891, January 2008
Technical Information
Ilumipod Inground IP Series User Manual (Rev. 02) 25
Page 30
Technical Information
write it on a properly
affixed label.
repair or replace returned
product(s).
will need those to ship the
unit back to
ILUMINARC
DO NOT write
the RMA #
directly on the
box. Instead,
ILUMINARC
reserves the
right to use its
own discretion to
Always keep the
original box and
all packaging
material as you
®.
®
Returns Procedure
The user must send the merchandise prepaid, in the original box, and with its original packing
and accessories. ILUMINARC
Call ILUMINARC
shipping the product. Be prepared to provide the model number, serial number, and a brief
description of the cause for the return.
The user must clearly label the package with a Return Merchandise Authorization Number
(RMA #). ILUMINARC
Once you receive the RMA #, please include the following information on a piece of paper
inside the box:
Your name
Your address
Your phone number
The RMA #
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate
packaging will be the customer’s responsibility. As a suggestion, proper UPS packing or
double-boxing is always a safe method to use.
Claims
The carrier is responsible for any damage incurred during shipping. Therefore, if the received
merchandise appears to have damages caused during shipping, the customer must submit the
damage report and any related claims with the carrier, not ILUMINARC
submit the report upon reception of the damaged merchandise. Failure to do so in a timely
manner may invalidate the customer’s claim with the carrier.
For other issues such as missing components or parts, damage not related to shipping, or
concealed damage, the customer must make claims to ILUMINARC
receiving the merchandise.
Contact Us
®
will not issue call tags.
®
and request a Return Merchandise Authorization Number (RMA #) before
®
will refuse any product returned without the RMA #.