s featured or referred to within this document are the property of their
The entire content of this document, except where applicable and unless otherwise noted, is solely
authorizes its customers to download and print this manual for professional
sage, copy, storage,
For better results, print this document in color, on letter size paper (8.5 x 11 inches), double sided.
If using A4 paper (210 x 297 mm), configure your printer to scale the content of this document to
should read the Guide that shipped with it and this manual in their entirety before
believes that the information contained in this manual is accurate in all respects.
assumes no responsibility for any error or omissions in this document.
and to make changes from time to time
to notify any person or company of
If you have any comments about the accuracy of this document or general suggestions regarding
3680. You can download the latest versions of
supersedes all previous versions of this
The Ilumipod 42 IP Optic Series User Manual Rev. 6 covers the
installation, programming, operation, and maintenance of the Ilumipod 42 IP Optic Series.
ILUMINARC
May 2015.
®
released this edition of the Ilumipod 42 IP Optic Series User Manual Rev. 6 in
Trademarks
The ILUMINARC® logo, the ILUMINARC® name, and all other trademarks in this document
related to services or products by ILUMINARC
ILUMINARC®, its affiliates or subsidiaries. Any other
names, or trademark
respective trademark holders.
®
Copyright Notice
owned by ILUMINARC®, a wholly owned trademark of Chauvet & Sons Inc.
All rights reserved.
Electronically published by ILU M INARC
®
in the United States of America.
Manual Usage
ILUMINARC®
information purposes only. ILUMINARC® expressly prohibits the u
distribution, modification, or printing of this manual or its content for any other purpose without
its written consent.
Document Printing
A4 paper.
Intended Audience
Any person i n charge o f insta lling, op erating, and/or mai ntaini ng the Ilumipod 42 IP Optic Series
fixtures
installing, operating, or maintaining this product.
Disclaimer
ILUMINARC®
However, ILUMINARC®
ILUMINARC® reserves the right to revise this document
in the conte nt hereof without obligation of ILU MINARC®
such revision or changes. T hi s d o es no t constitute in an y wa y a c o m mit ment by ILUMINA RC® to
make such c hanges. I LUMINAR C
incorporate such changes.
®
may issue a revision of this manual or a new editio n of it to
ILUMINARC® Publications Hot Line
how we can improve it, please call us at (954) 923all ILUMINARC® products’ manuals from www.iluminarc.com.
Document Revision
The Ilumipod 42 IP Optic Series User Manual Rev. 6
manual. Please discard any older versions of this manual you may have, whether in printed or
electronic format, and replace them with this version.
A range of menu values from which to choose in a menu
Yes/No
A set of two mutually exclusive menu options in a menu
ON
A unique value to enter or select in a menu
Introduction
critical information.
installation or
configuration information.
Failure to comply with this
information may prevent
the fixture from
functioning correctly.
configuration, or operation
information. Failure to
comply with this
information may render
the fixture partially or
completely inoperative,
damage third-party
equipment, or cause harm
to the user
refers to the USITT
DMX512-A transmission
protocol.
This icon
indicates useful,
although non-
This icon
indicates
important
This icon
indicates critical
installation,
The term “DMX”
used throughout
this document
What is Included
• One Ilumipod 42 IP Optic Series Fixture
• Warranty Card
• Quick Reference Guide
Unpacking Instructi ons
Immediately upon receiving a product from ILUMINARC®, carefully unpack the carton. Check
the contents of the box to ensure t ha t a l l p ar ts ar e p r ese nt a nd t ha t t he y a r e i n go o d co nd i tio n. I f
any part appears damaged from shipping, or if the carton shows signs of mishand ling, see t he
Claims section in the Technical Information chapter.
Text Conventions
Ilumipod 42 IP Optic Series User Manual Rev. 6 1
Introduction
Technical Support.
product. Any reference to
servicing it you may find
from now on in this User
Manual will only apply to
properly ILUMINARC
certified technicians. Do
not open the housing or
attempt any repairs
unless you are one of
them.
regulations for the proper
installation of this product.
you sell this product to
another user, make sure
that they also receive this
manual.
Optic Series fixture may
require service, please
contact ILUMINARC
There are no
user serviceable
parts inside this
®
Please refer to all
applicable local
codes and
Keep this manual
for future
consultation. If
In the unlikely
event that your
Ilumipod 42 IP
®
Safety Notes
Please read all the following safety notes carefully because they include important information
on how to install, use, and maintain this product safely.
Personal Safety
• Avoid direct eye exposure to the light source while the fixture is on.
• Always disconnect this product from its power source before servicing.
• Always conne ct this product to a grounded circuit to avoid the risk of electrocution.
• Do not touch this product’s hous ing when operating because it may be very hot.
Mounting and Rigging
• This product is for outdoor use and it can be submerged (IP67). However, do not
submerge it deeper than 1 m for more than (30) thirty minutes.
• CAUTION: When transferring product from extreme temperature environments, (e.g.
cold truck to warm humid ballroom) condensation may form on the internal electronics
of the product. To avoid causing a failure, allow product to fully acclimate to the
surrounding environment before connecting it to power.
• Do not allow the product to remain pointed straight down.
• When hanging this product, a l ways secure it to a fa s t ening device using a safety cable.
Power and Wiring
• Always make sure that you are connecting this product to the proper voltage, as per the
specifications in this manual or on the product’s sticker.
• Never connect this product to a dimmer.
• Make sure that the power input cable is not cracked, crimped, or damaged.
• Never disconnect this product by pulling or tugging on the power input cable.
Operation
• The maximum ambient temperature (Ta) is 104° F (40° C). Do not operate this product
at a higher temperature.
•In case of a serious operating problem, stop using this product immediately!
2 Ilumipod 42 IP Optic Series User Manual Rev. 6
Product Description
2. Product Description
The Ilumipod 42 IP Optic Series encompasses two types of fixtures, the Ilumipod 42 IP Optic
RGBW and Ilumipod 42 IP Optic VW. These fixtures are available in 15 degree and 30 degree
optics.
Common Features
• 316 Stainless Steel hardware for corrosive environments
• 3, 4, 5, 6, or 11-channel RGBW LED wash light with ID addressing
• Operating modes:
3-channel: HSV control
3-channel: RGB control
4-channel: RGB, dimmer
4-channel: RGBW control
5-channel: RGBW, dimmer
6-channel: RGBW, dimmer, strobe
11-channel: RGBW, dimmer, macros, strobe, auto/custom, auto speed, ID
addressing, dimmer curve
• Static color mixing with or without a DMX controller
• Five distinct dimmer curves
• Color temperature presets (3,200 K ~ 10,000 K)
• Optical systems: 15°and 30°
SpectraWhite™ Features
• 1, 2, 3 or 6-channel DMX LED wash light with ID ad dressing
• Operating modes:
1-channel: Dimmer
2-channel: Color temperature macros
2-channel: Warm white, cool white control
3-channel: Dimmer, warm white, cool white, color
6-channel: Dimmer, warm white, cool white, color, temperature macros, strobe, ID
addressing
• Static color temperature contr ol with or without a DMX controller
• VW SpectraWhite™ mixing with or without DMX controller via Integrated command™
LCD display
•2,800 K and 7,000 K LEDs
Ilumipod 42 IP Optic Series User Manual Rev. 6 3
Product Description
316 Stainless
Steel Hardware
Tempered Glass
Lens Cover
Tamper
Resistant
Adjustment Bolt
Cast Aluminum
Housing
Safety Cable
Loop
Humidity
Control Valve
(under bracket)
Power In
DMX In/Out
(under bracket)
13 mm
Mounting Holes
Heavy Duty
Mounting
Bracket
LED Display
(under cover)
Product Overview
Front View
Rear View
4 Ilumipod 42 IP Optic Series User Manual Rev. 6
Product Dimensions
Product Description
Ilumipod 42 IP Optic Series User Manual Rev. 6 5
Installation
AC Live
Black
Yellow or Brass
Brown
1
AC Neutral
White
Silver or Gray
Blue
2
AC Ground
Green/Yellow
Green
Green/Yellow
3
3. Installation
Always connect
the Ilumipod 42
IP Optic Series to
a protected circuit with an
appropriate electrical
ground to avoid the risk of
electrocution or fire.
Never connect
the Ilumipod 42
IP Optic Series to
a rheostat (variable
resistor) or dimmer circuit,
even if the rheostat or
dimmer channel serves
only as a 0 to 100%
switch.
Please refer to all
applicable local
codes and
regulations for the proper
installation of this product.
AC Power
The Ilumipod 42 IP Optic Series has an auto -ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
Make sure that you are connecting this product to the proper voltage, as per the specifications in
this guide, the product’s QRG, or on the product’s sticker.
Power Consumption
To determine the power requirements for the Ilumipod 42 IP Optic Series, see the label
affixed to the side of the fixture or refer to the corresponding specifications chart in the
Technical Information chapter of this manual.
The listed current rating indicates the maximum c urrent draw during normal operation.
AC Plug
The Ilumipod 42 IP Optic Series comes with an un-terminated power input cord for
hardwirin g during installation. Use the table/illustration below to wire a plug.
Connection Wire (US) Screw Color (US) Wire (Europe) IP67 Pin
Power Wiring
You can connect the bare-ended IP67 rated AC power cable from the fixture to an IP67
rated power connector.
You may also use IP67 rated junction boxes for surface installations or direct buried cable
(DBC)for buried installations.
If using junction boxes, make sure to use IP67 rated conduit for surface installations or
direct buried cable (DBC) for buried installations. You could also use direct buried cable
(DBC) to link the junction boxes. See below for a wiring illustration.
6 Ilumipod 42 IP Optic Series User Manual Rev. 6
Installation
The Operation
chapter of this
manual provides
detailed
inst ructions on how to
configure the Master and
Slave units.
DMX Linking
You may link the Ilumipod 42 IP Optic Series to a DMX controller using a standard DMX
serial connection. If using other DMX compatible fixtures with the Ilumipod 42 IP Optic Series,
it is possible to control them individually with a single DMX controller.
It is also possible to run several DMX compatible fixtures synchronized without a DMX
controller in a master/slave operating mode. The Ilumipod 42 IP Optic Series does support the
master/slave mode.
If you are not familiar with the DMX standard, or if you need information about the DMX
cables needed to link the Ilumipod 42 IP Optic Series to a DMX controller, you may download
the “DMX Primer” document from the ILUMINARC® Web site.
DMX Modes
The Ilumipod 42 IP Optic Series uses the standard DMX data connection for all its DMX
personalities whet he r they are RGBW or VW ve rs io ns. Refer to the Introduction chapter for
a brief description of these modes and the Operation chapter to learn how to configure t he
Ilumipod 42 IP Optic Series to work in these modes. The DMX Values section wi ll gi ve yo u
detailed information regarding the above-mentioned DMX modes.
Protocol Connectivity
The Ilumipod 42 IP Optic Series uses USITT DMX 512 Protocol. The procedure below
illustrates the recommended connection method.
Master/Slave Linking
The Master/Slave mode allows a Ilumipod 42 IP Optic Series fixture (the master) run ning a
preconfigured program to control several other Ilumipod 42 IP Optic Series fixtures (t he sl a ves)
without requiring a DMX con troller. In this mode, all the slave fixt ures will operate in unison
with the mast er fixture.
When in Master/Slave mode, the Ilumipod 42 IP Optic Series units li nk to ea ch othe r usi ng the
standard DMX connection.
ID Addressing
The Ilumipod 42 IP Optic Series uses the ID Addressing feature to increase the number of
addressable fixtures in the same DMX universe when in the TOUR personality. Refer to the
Operation chap ter in this ma nual to lea rn in detail how to co nfigure the Ilumipod 42 IP Optic
Series fixtures when using ID Addressing.
Ilumipod 42 IP Optic Series User Manual Rev. 6 7
Loading...
+ 23 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.