trademarks featured or referred to within this document are the property of their
except where applicable and unless otherwise noted, is
authorizes its customers to download and print this manual for professional
sage, copy, storage,
r any other purpose
For better results, print this document in color, on letter size paper (8.5 x 11 inches), double
should read the Guide that shipped with it and this manual in their entirety before
believes that the information contained in this manual is accurate in all
assumes no responsibility for any error or omissions in this
to notify any person or
whether in printed or electronic format, and replace them with this version.
Edition Notes
The Ilumiline Inground IP Optic 25 Series User Ma nual Rev. 1 0
precautions, installation, p rogra mming, op era tion, and maint ena nce o f t he se Ilumiline I nground
®
IP products. ILUMINARC
r eleased this edition o f the Ilumiline Inground IP Optic 25 Series
User Manual Rev. 10 in May 2015.
Trademarks
The ILUMINARC® l ogo, the ILUMINA RC®
related to services or products by ILUMINARC®
ILUMINARC®, its affiliates or subsidiaries. Any other
names,
respective trademark holders.
Copyright Notice
The entire c ontent of this document,
solely owned by ILUMINARC®, a wholly owned trademark of Chauvet & Sons, Inc.
ILUMINARC®
information purposes only. ILUMINARC® expressly prohibits the u
distribution, modification, or printing of this manual or its content fo
without its written consent.
Document Printing
sided. If using A4 paper (210 x 297 mm), configure your printer to scale the content of this
document to A4 paper.
Intended Audience
Any person i n charge of install ing, operating, and/or main taining these Ilumiline Inground IP
products
installing, operating, or maintaining this product.
Disclaimer
ILUMINARC®
respects. However, ILUMINARC®
document. ILUMINARC® reserves the right to revi se th is document a nd to make c ha nges from
time to time in the co ntent her eof withou t obligatio n of I LUMINARC
company of s uch revision or c hanges. This does no t constitute in an y way a commitment b y
®
ILUMINARC
to make suc h changes. ILUMINARC® may iss ue a r e vi sio n of this manua l o r a
new edition of it to incorporate such changes.
Document Revision
The Ilumiline Inground IP Optic 25 Series User Manual Rev. 10 supersedes all previous
versions of this manual. Please discard any older versions of t his manual you may have,
Author Date Editor Date
D. Couppe 5/1/15
®
Ilumiline Inground IP Optic 25 Series User Manual Rev. 10
ii Ilumiline Inground IP Optic 25 Series User Manual Rev. 10
1. Introduction
1~512
A range of values in the text
50/60
A set of mutua lly exclusive values in t he text
“ILUMICON UM”
The name of another publication or manual
<SET>
A button on the product’s control panel
Settings
A product function or a menu option
MENU > Settings
A sequence of menu options
1~10
A range of menu values from which to choose in a menu
Yes/No
A set of two mutually exclusive menu o ptions in a menu
ON
A unique value to enter or select in a menu
Introduction
critical information.
installation or
configuration information.
Failure to comply with this
information may prevent
the product from
functioning correctly.
configuration, or operation
information. Failure to
comply with this
information may render
the product partially or
completely inoperative,
damage third-party
equipment, or cause harm
to the user.
refers to the USITT
DMX512-A transmission
protocol.
This icon
indicates useful,
although non-
This icon
indicates
important
This icon
indicates critical
installation,
The term “DMX”
used throughout
this document
What Is In the Box
•One Ilumiline Inground Tri-12 IP Optic 25 RGB, or
One Ilumiline Inground 12 IP Optic 25 WW
• One Power Input Cable (bare-ended)
• One Data Input/Output Cable (bare-ended)
• One Installation Sleeve
• One Pour Kit Cover
• One Warranty Card
• One Quick Reference Guide
Unpacking Instructi ons
Immediately upon receiving a product from ILUMINARC®, carefully unpack the carton. Check
the contents of the box to ensure that all p a r ts a r e present and that they are in good condition.
Claims
The carrier is responsible for any damage incurred during shipping. Therefore, if the
received merchandise appears to have been damaged during shipping, the customer
must submit the damage report and any related claims to the carrier, not
ILUMINARC
merchandise. Failure to do so in a timely manner may invalidate the customer’s claim
with the carrier.
For other issues such as missing components or parts, damage not related to shipping,
or concealed damage, the customer must make claims to ILUMINARC
(7) days of receiving the merchandise.
®
. The customer must submit the report upon receipt of the damaged
®
wit hin se ven
Text Conventions
Convention Meaning
Ilumiline Inground IP Optic 25 Series User Manual Rev. 10 1
Introduction
product. Any reference to
servicing you may find
from now on in this User
Manual will only apply to
properly certified
ILUMINARC
technicians. Do not open
the housing or attempt
any repairs unless you
are certified to do so.
regulations for the proper
installation of this product.
consultation. If you sell
this product to another
user, make sure that they
also receive this manual.
product may require
service, please contact
ILUMINARC
Support.
There are no user
serviceable parts
inside this
®
Please refer to
all applicable
local codes and
Keep this
manual for
future
In the unlikely
event that your
Ilumiline
Inground IP
®
Technical
Safety Notes
Please read all the following safety notes carefully because they include important information
on how to install, use, and maintain this product safely.
Personal Safety
• Avoid direct eye exposure to the light source while the product is on.
• Always disconnect this product from its power source before servicing.
• Always connect this product to a grounded circuit to avoid the risk of electrocution.
• Do not touch this product’s housing when operating because it may be very hot.
Mounting and Installation
•This product is for outdoor use and can be submerged (IP67). However, do not
submerge deeper than 1 m for more than thirty (30) minutes.
•CAUTION: When transferring product from extreme temperature environments, (e.g.
cold truck to warm humid ballroom) condensation may form on the internal electronics
of the product. To avoid causing a failure, allow product to fully acclimate to the
surrounding environment before connecting it to power.
•Make sure there are no flammable materials close to this product while operating.
Power and Wiring
•Always make sure that you a re connecting this product to the proper voltage, as per the
specifications in this manual or on the product’s sticker.
• Never connect this product to a dimmer pack.
• Make sure that the power input cable is not cracked, crimped, or damaged.
• Never disconnect this product by pulling or tugging on the power input cable.
Operation
•The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at a
higher temperature.
•In case of a serious operating problem, stop using this product immediately!
2 Ilumiline Inground IP Optic 25 Series User Manual Rev. 10
Product Description
2. Product Description
The I lumiline Inground Tri-12 IP Optic 25 RGB is a Tri-color linear wash light intended for
inground in stallatio n. The Ilumiline Inground 12 IP Optic 25 WW is the Warm White version.
Both produc ts consist of a cast aluminum body containing a power supply, control unit, and
drive-over rated glass lens cover.
Common Features
• Five distinct dimming curves
• IP67 ingress protection
• IP67 stainless steel gland nuts for c a ble entry
• ADA compliant skid resistant, drive-over rated glass lens cover
• Remotely addressable with Ilumicode Addresser
• Integrated Cooling Enhancement™
• Humidity controlling Gore ™ valve
• Ilumicode compatible
RGB Features
• 1, 3, 4, 6, or 7 channel DMX-512 LED inground linear wash product
• Operating modes:
1-channel: Dimmer
3-channel: RGB control
4-channel: Dimmer, RG B control
6-channel: RGB control per module (two modules)
7-channel: Dimmer, RGB control, color macros, strobe, dimmer speed
•High Power 3 W (1,050 mA) Tri Color LEDs
Options
• Ilumicode Addresser (required for product configuration)
WW Features
• 1 channel DM X-512 LED inground linear wash product
• Operating modes:
1-channel: Dimmer
•High Power 1 W (350 mA) Warm White LEDs
Ilumiline Inground IP Optic 25 Series User Manual Rev. 10 3
Front View
Side View
End View
Product Description
Product Overview
Mounting
Screws
Concrete
Installation
Sleeve
Port Holes
for
Data/Power
4 Ilumiline Inground IP Optic 25 Series User Manual Rev. 10
Product Dimensions
Product Description
Ilumiline Inground IP Optic 25 Series User Manual Rev. 10 5
and power cables when setting down the
To power
distribution box.
To signal
distribution box.
Installation
3. Installation
Always keep the
power cables away
from the signal
cables by running
them in different conduits
and using separate
distribution boxes.
For best results,
insure that the
frosted portion of
the lens is
orientated towards the
surface you are trying to
illuminate.
Ilumiline Inground
IP products can
support a
distributed load of up to
3,000 kg (6,614 lbs) when
properly installed.
Installation Notes
Both Ilumiline Inground IP products consist of two components:
• Product housing, which is IP67 rated.
• Concrete installation sleeve, which is not IP67 rated.
Read the Installation Sleeve Setup instructions in this User Manual carefully.
Do not use the product’s junction box to extend the power or signal cables to other units. This
might compromise the IP rating of the junction box. Instead, use individual cables from the
product to the corresponding signal and/or power distribution boxes.
Installation Sleeve Orientation
You will have to run the AC power and signal cables into the concrete installation
sleeve.
Position the i nstallation slee ve so t he signal cable enters the slee ve us in g one of the t wo
cable inlets.
Use the opposite inlet for the power cable (refer to the following figure).
This will reduce the stress to the signal
product, while keeping both cables separated under the product housing.
Power
cable
Signal
cable
6 Ilumiline Inground IP Optic 25 Series User Manual Rev. 10