ILP CFL-110W Series, CFM-52W Series, CFS-36W-U Series, CFM-52W-U Series, CFM-85W-U Series Installation Instructions Manual

...
ILP – Industrial Lighting Products, LLC
519 Codisco Way, Sanford, FL 32771
Phone: (407) 478 3759 Fax: (407) 478 3760
www.ilp-inc.com
CONVERTAFLOOD REFLECTOR
INSTALLATION INSTRUCTIONS
MODELS:
CFS-36W-U-XX CFM-52W-U-XX or CFM-85W-U-XX CFL-110W-U-XX or CFL-150W-U-XX
(Note: Replace XX with 40 or 50 based on CCT of LED, may be followed by BLK, BRZ, or WHT)
Part Number List:
(Note: The NEMA 7x6 reflector comes Standard on the Convertaflood. Replacements are available.)
1. Introduction
The CF Family LED Floods use easy replaceable snap-in type reflectors to customize
to your lighting needs.
MODEL
REFLECTOR PART NUMBERS
NEMA 3X3
NEMA 4X4
NEMA 5X5
NEMA 7x6
CFS-36W
-
N44/S
N55/S
N76/S
CFM-52W
N33/M52
N44/M52
N55/M
N76/M
CFM-85W
-
N44/M85
N55/M
N76/M
CFL-110W or CFL-150W
N33/L
N44/L
N55/L
N76/L
Warning:
To avoid the risk of fire, explosion, or electric shock, this product shall be installed, inspected, and maintained by a qualified electrician, in accordance with all applicable electrical codes.
Warning:
To avoid electric shock:
Allow product to cool before servicing.
Be certain electrical power is OFF before and during installation or maintenance.
Luminaire must be connected to a wiring system with equipment-grounding conductor.
Warning:
To avoid LED damage:
Please do not touch the LED when replacing the reflector. Touching the LED may result in damage or failure of the LED.
ILP – Industrial Lighting Products, LLC
519 Codisco Way, Sanford, FL 32771
Phone: (407) 478 3759 Fax: (407) 478 3760
www.ilp-inc.com
2. Installation
Step 1 Open the back cover by using the provided tool to loosen the security closure screw, hold and compress fixture lightly while depressing the cover opening latch. (FIG.1)
Step 2 Remove existing reflector by tilting the reflector forward until the tabs release than slightly pull outward to remove the reflector. (FIG.2)
Step 3 Replace reflector by tilting the reflector forward and dropping into the bottom tabs. slightly push forward till the reflector snaps in the remaining tabs. (FIG.3)
Step 4 Close the back cover and tighten the security closure screw using the provided tool to approx. 10 ft lbs.
After installation, please
Ensure the lighting fixture is firmly secure to its mount.Ensure wires are connected correctly before applying power.
To complete installation, turn power ON, check for proper operation of luminaire.