ILME CX-25IM Data Sheet

Part number
CX 25 IM
Product description Model Version Product type Family Size N. of poles Technical data Current Voltage Pollution degree Operating temperature range
(min, max) IP degree of protection Further technical details
Characteristics according to EN 61984
Insulation resistance Rated voltage according to
UL/CSA UL 94 flammability rating Weight
4 A (A.C. and D.C.) 50 V 3
-40°C … +125°C IP20 without enclosure; IP65/IP66/IP67/IP68 with
enclosure
5A 50V 10A 3 10 G 50V V-0
9,00 g
Brief description:
male insert, 25 poles, crimp connections, 4A 50V, 3, for 5A male contacts, 1 module, modular units series MIXO
Approvals / Standards Reference standard
Quality mark Conformity
General ordering information EAN13 code Tariff number Packaging Information Packaging length Packaging height Packaging width Packaging weight Packaging volume Packaging description Packaging quantity Packaging EAN code Sub-packaging length Sub-packaging height Sub-packaging width Sub-packaging weight Sub-packaging volume Sub-packaging description Sub-packaging quantity Sub-packaging EAN barcode
EN 61984 (2001-11)
EAC
8015747148320 85369095
180,00 mm 130,00 mm 150,00 mm 2,00 kg 3,51 dm³ Carton box 60 Pcs 8015747221368 35,00 mm 40,00 mm 155,00 mm 0,33 kg 0,22 dm³ Carton 10 Pcs 8015747148344
Part number
CX 25 IM
Notes
Inserts CX 25 IF/M
- characteristics according to EN 61984: 4A 50V 0.8kV 3 4A 160V 2.5kV 2
- insulation resistance: > 10 GOhm
- ambient temperature limit: -40 °C ... +125 °C
- are made of self-extinguishing thermoplastic resin UL 94 V0
- mechanical life: > 500 cycles
- for crimp contacts CI series using: CIPZ D crimping tool CITP D turret head CIES insertion / removal tool
- we recommend the use of CRF / CRM code pins
- 1 frame slot
the modular inserts must be installed in suitable frames which in turn are installed in traditional housings or COB panel support