ILME CX-08CF Data Sheet

Part number
CX 08 CF
Product description Model Version Product type Family Size N. of poles Technical data Current Voltage Rated impulse withstand
voltage Pollution degree Operating temperature range
(min, max) IP degree of protection Further technical details
Characteristics according to EN 61984
Insulation resistance Rated voltage according to
UL/CSA UL 94 flammability rating Weight
16 A (A.C. and D.C.) 400 V
6kV 3
-40°C … +125°C IP20 without enclosure; IP65/IP66/IP67/IP68 with
enclosure
16A 400V 6kV 3; 16A 400/690V 6kV 2 10 G 600V V-0
9,00 g
Brief description:
female insert, 8 poles, crimp connections, 16A, 400V, 6kV, 3, 1 module, modular units series MIXO
Approvals / Standards Reference standard
Quality mark Conformity
General ordering information EAN13 code Tariff number Packaging Information Packaging length Packaging height Packaging width Packaging weight Packaging volume Packaging description Packaging quantity Packaging EAN code Sub-packaging length Sub-packaging height Sub-packaging width Sub-packaging weight Sub-packaging volume Sub-packaging description Sub-packaging quantity Sub-packaging EAN barcode
EN 61984 (2001-11)
, EAC
CQC, CE
8015747129237 85369095
180,00 mm 130,00 mm 150,00 mm 0,75 kg 3,51 dm³ Carton box 60 Pcs 8015747221290 35,00 mm 40,00 mm 155,00 mm 0,13 kg 0,22 dm³ Carton 10 Pcs 8015747129244
Part number
CX 08 CF
Catalogue drawings
Catalogue drawings
Notes
CX 08 C inserts:
- characteristics according to EN 61984: (16A 400V 6kV 3) (16A 400/690V 6kV 2)
- footprint 1 modules
- for maximum current load, see the insert load curve section
- for contact crimping instructions, please see the crimping tool section (16A contacts, CCF, CCM and CC...AN series)
the modular inserts must be installed in suitable frames which in turn are installed in traditional housings or COB panel support