Part number
CX 04 XF
Product description
Model
Version
Product type
Family
Size
N. of poles
Technical data
Current
Voltage
Rated impulse withstand
voltage
Pollution degree
Operating temperature range
(min, max)
IP degree of protection
Further technical details
Characteristics according to
EN 61984
Insulation resistance
Rated voltage according to
UL/CSA
UL 94 flammability rating
Weight
female insert
Crimp connection
for female contacts 40A
MIXO series, customizable inserts
1 module
4 poles
40 A (A.C. and D.C.)
830 V
8kV
3
-40°C … +125°C
IP20 without enclosure; IP65/IP66/IP67/IP68 with
enclosure
40A 830V 8kV 3; 40A 1000V 8kV 2
≥ 10 GΩ
600V
V-0
13,00 g
Brief description:
female insert, 4 poles, crimp connections, 40A 830V, 8kV, 3, 1 module, modular
units series MIXO
Approvals / Standards
Reference standard
Quality mark
Conformity
General ordering information
EAN13 code
Tariff number
Packaging Information
Packaging length
Packaging height
Packaging width
Packaging weight
Packaging volume
Packaging description
Packaging quantity
Packaging EAN code
Sub-packaging weight
Sub-packaging description
Sub-packaging quantity
Sub-packaging EAN barcode
EN 61984 (2001-11)
, EAC
CQC, CE
8015747097291
85369095
112,00 mm
95,00 mm
117,00 mm
0,13 kg
1,24 dm³
Carton box
10 Pcs
8015747098373
0,01 kg
Plastic bag
1 Pcs
8015747098595
Part number
CX 04 XF
Notes
Inserts CX 04 XF/M
- characteristics according to EN 61984:
40A 830V 8kV 3
40A 1000V 8kV 2
- rated voltage according to UL/CSA: 600V
- insulation resistance: > 10 GOhm
- ambient temperature limit: -40 °C ... +125 °C
- are made of self-extinguishing thermoplastic resin UL
94 V0
- mechanical life: > 500 cycles
- contact resistance: < 0.3 mOhm
- for contact crimping instructions, please see the
crimping tool section (40A contacts, CXF and CXM
series)
- male and female contacts to test of contact with fingers
- for maximum current load, see the following load
curves inserts
- 1 frame slot
- Female inserts are supplied with two red lock tabs
that must be used instead of those supplied with the
frames.
Finger proof (IP2X or IPXXB) upon connector unmated.
the modular inserts must be installed in suitable frames which in turn
are installed in traditional housings or COB panel support