ILME CX-04XF Data Sheet

Part number
CX 04 XF
Product description Model Version Product type Family Size N. of poles Technical data Current Voltage Rated impulse withstand
voltage Pollution degree Operating temperature range
(min, max) IP degree of protection Further technical details
Characteristics according to EN 61984
Insulation resistance Rated voltage according to
UL/CSA UL 94 flammability rating Weight
40 A (A.C. and D.C.) 830 V
8kV 3
-40°C … +125°C IP20 without enclosure; IP65/IP66/IP67/IP68 with
enclosure
40A 830V 8kV 3; 40A 1000V 8kV 2 10 G 600V V-0
13,00 g
Brief description:
female insert, 4 poles, crimp connections, 40A 830V, 8kV, 3, 1 module, modular units series MIXO
Approvals / Standards Reference standard
Quality mark Conformity
General ordering information EAN13 code Tariff number Packaging Information Packaging length Packaging height Packaging width Packaging weight Packaging volume Packaging description Packaging quantity Packaging EAN code Sub-packaging weight Sub-packaging description Sub-packaging quantity Sub-packaging EAN barcode
EN 61984 (2001-11)
, EAC
CQC, CE
8015747097291 85369095
112,00 mm 95,00 mm 117,00 mm 0,13 kg 1,24 dm³ Carton box 10 Pcs 8015747098373 0,01 kg Plastic bag 1 Pcs 8015747098595
Part number
CX 04 XF
Notes
Inserts CX 04 XF/M
- characteristics according to EN 61984: 40A 830V 8kV 3 40A 1000V 8kV 2
- rated voltage according to UL/CSA: 600V
- insulation resistance: > 10 GOhm
- ambient temperature limit: -40 °C ... +125 °C
- are made of self-extinguishing thermoplastic resin UL 94 V0
- mechanical life: > 500 cycles
- contact resistance: < 0.3 mOhm
- for contact crimping instructions, please see the crimping tool section (40A contacts, CXF and CXM series)
- male and female contacts to test of contact with fingers
- for maximum current load, see the following load curves inserts
- 1 frame slot
- Female inserts are supplied with two red lock tabs that must be used instead of those supplied with the frames.
Finger proof (IP2X or IPXXB) upon connector unmated.
the modular inserts must be installed in suitable frames which in turn are installed in traditional housings or COB panel support