Ikelite 5510.35 Instruction Manual

Page 1
Flat Modular Port
n s t r u c t i o n m a n u a l
i
Thank you for your purchase of the Ikelite Flat Modular Port System. Ikelite products have been designed and built in the USA for over 45 years by Ikelite for both the professional and amateur photographer.
Our modular port system allows you to build a port out of universal components to accommodate a variety of macro, zoom, and wide­angle lenses. The interchangeable port bodies and extensions combine to create endless combinations for maximum versatility and performance.
This product should receive the same care and attention as your other photographic products.
Cover the faceplate with the protective cover when not in use.
IImmppoorrttaanntt NNoottiicce
Port Bodies are engraved with a Maximum Depth Rating, “RRAATTEEDD 220000 FFTT ((6600mm)) rests against the front of the camera housing; see illustration.
Older Standard
and Extended Port
odies that are NOT
B ENGRAVED, HAVE A MAXIMUM DEPTH RATING OF 150 FEET (45M). The unmarked Standard or Extended Port Bodies can be returned to Ikelite for a no charge replacement with the newer 200 ft. (60m) rated Bodies,
SSeenndd PPoorrtt BBooddyy OOnnllyy
#5510.10 and #5510.11 Superwide Port Bodies are “Rated 200 ft. (60m)“ whether or not they are engraved. DO NOT return Superwide bodies for exchange. Superwide bodies are NOT recommended for use with the Modular Flat Port system.
e
They are engraved on the flat flange that
.
Maximum
Depth Rating
engraved
on flange
.
SSppeecciiaall RReeqquuiirreemmeenntt ffoorr NNiikkoonn 110055mmmm VVRR LLeennss
Use of the new Modular Flat Port with the Nikon 105 VR Macro lens requires modification to early Port Bodies. This modification expands the inner diameter of the Port Body to accept the larger base of the Nikon 105mm VR lens. Port Bodies produced after 4/15/08 will include this modification and will bear the designation that rests against the housing body. Early Port Bodies without this designation may be returned directly to Ikelite to be modified for use with the Nikon 105mm VR Lens.
RRAATTEEDD 220000FFTT ((6600mm)) LLAARRGGEE DDIIAA..
2
on the flange
IImmppoorrttaanntt IInnffoorrmmaattiioonn
PPoorrtt SSeeaall IInnssiiddee VViieeww
Due to the overhang of the port flange, the port seal is most visible when viewed by looking inside the housing before the camera is inserted. After the port is installed, check to see that the o-ring is properly sealed as shown in Figure 1 and not extruded as shown in Figure 2.
CCAAUUTTIIOONN:: WWhheenn tthhee ppoorrtt wwiillll nnoott bbee uusseedd ffoorr pprroolloonnggeedd
ppeerriiooddss wwee rreeccoommmmeenndd uunnssccrreewwiinngg aallll sseeccttiioonnss ooff tthhee PPoorrtt.. IIff
sseeccttiioonnss aarree nnoott uunnssccrreewweedd ffoorr pprroolloonnggeedd ppeerriiooddss iitt ccaann mmaakkee
uunnssccrreewwiinngg ddiiffffiiccuulltt..
For prolonged storage, the port should be removed from the housing and the port sections should be unscrewed. All o-rings on port sections should be removed, cleaned, lightly lubricated and reinstalled on each port section. If you screw the port sections back together for storage, only engage a few threads leaving the sealing o-ring visible.
Cover the Flat Glass Assembly with protective cover when not in use.
CCAAUUTTIIOONN
ingredient can cause cracking in this product.
: Never use spray lubricants as the propellant
3
Fig. 1
Fig. 2
SSccrreewwiinngg MMoodduulleess TTooggeetthheerr
Once prepared for assembly the modules can be screwed together and only need to be hand tight. A strap wrench is supplied and can be used to assemble or disassemble as required.
strap wrench
PPrreeppaarriinngg tthhee FFllaatt AAsssseemmbbllyy MMoodduullee ffoorr IInnssttaallllaattiioonn
The Flat Assembly Module has an o-ring that seals and holds the clear faceplate in place. the clear faceplate o-ring. The interior and exterior of the clear faceplate can be cleaned with fresh water or water with a mild non-abrasive soap. On the inside of the Flat Assembly Module just below the internal threads is a flat sealing surface. This sealing surface is where the o-ring on the Port Body or Extension Ring will seal when they are screwed together. Make sure the threads and sealing surface are clean. Use a Q-tip and fresh water, or water with a mild non-abrasive soap to clean.
DDoo NNoott
remove
4
Clear Faceplate o-ring
Clear Faceplate
Flat Assembly Module
Page 2
PPrreeppaarriinngg PPoorrtt BBooddiieess aanndd OO--rriinnggss ffoorr IInnssttaallllaattiioon
n
The Port Body has 2 o-rings. The o-ring on the bottom seals
gainst the port opening in the SLR-DC housing. The top o-ring
a seals against an Extension Ring or the Flat Port
o-ring
Assembly. Both o-rings
hould be clean and lightly
s lubricated before installation. To remove the top o-ring from it’s groove, use a non-sharp instrument such as a small flat bladed
housing/port
o-ring
Port Body
screwdriver. O-rings can be cleaned with fresh water. To lubricate the o-ring, put a small amount of lubricant on your finger tips and gently pull the o-ring through your fingers. Use only a small amount of lubricant. The o-ring only needs a light coating of lubricant, just enough to make it feel slick. Remove any excess lubricant as it can collect foreign particles such as sand, which can interfere with sealing. When gently pulling the o-ring through your fingers, do not stretch the o-ring. Check the o-ring groove where the o-ring fits on the Port Body to make sure it is clean. Use Q-tips and fresh water, or water with a mild non-abrasive soap to clean the groove. Also check the port opening in the housing where the housing/port o-ring will seal to make sure it is clean.
PPrreeppaarriinngg PPoorrtt EExxtteennssiioonnss ffoorr IInnssttaallllaattiioonn
NNoonn--FFooccuuss EExxtteennssiioonn MMoodduulle
f an extension ring is used in your Flat Port system, the o-ring
I below the outer threads should be removed, cleaned, and lightly lubricated before installing the Flat Port Assembly.
n the inside of the Extension
O Ring just below the internal threads is a flat sealing surface. This sealing surface is were the o-ring on the Port Body will seal when they are screwed together. Make sure the threads and sealing surface are clean, use a Q-tip with fresh water, or water with a mild non-abrasive soap solution.
For proper o-ring preparation, Refer to page 5 BBooddiieess aanndd OO--rriinnggss ffoorr IInnssttaallllaattiioonn))
e
Extension Module
((PPrreeppaarriinngg PPoorrtt
.
FFooccuuss EExxtteennssiioonn MMoodduullee ##55551100..7755
If you are using a Focus Extension Module, please refer to your Ikelite Manual Focus Port Extension #5510.75 instruction manual for proper installation.
#5510.10 and #5510.11 Super-Wide Port Bodies are NOT recommended for use with the Modular Flat Port system.
5
AAsssseemmbblliinngg tthhee FFllaatt PPoorrtt
PPoorrtt ccoonnssiissttss ooff FFllaatt AAsssseemmbbllyy MMoodduullee aanndd PPoorrtt BBooddyy MMoodduullee Assemble the Flat Port by screwing each module together as shown. Modules only need to be hand tight.
#5510.35 Flat Assembly Module
Port Body Module
(varies in length)
#5510.16 shown
FFooccuuss EExxtteennssiioonn MMoodduullee iiss nnoott ttoo bbee uusseedd wwiitthh SSuuppeerr--WWiiddee PPoorrtt BBooddyy ##55551100..1100 oorr ##55551100..1111
5510.75 Focus Extension Module
6
AAsssseemmbblliinngg tthhee FFllaatt PPoorrtt
PPoorrtt ccoonnssiissttss ooff FFllaatt AAsssseemmbbllyy MMoodduullee,, EExxtteennssiioonn MMoodduullee oorr FFooccuuss EExxtteennssiioonn MMoodduullee,, aanndd PPoorrtt BBooddyy MMoodduullee.. Assemble the Modular Flat Port by screwing each module together as shown. Modules only need to be hand tight.
#5510.35 Flat Assembly Module
5510.75 Focus Extension Module
Extension Module
(varies in length)
Port Lock
Housing port opening
7
Port Body Module
(varies in length)
Port Lock
Housing port opening
8
Page 3
IInnssttaalllliinngg tthhee MMoodduullaarr FFllaatt PPoorrtt
Slide To Open
Lift To Unlock
Open Position
Port Lock Release Button in Locked Position
Port Lock Release Button in Unlocked Position
P
ush forward
t
o Lock —Release Button
w
ill drop down and click into
l
ocked position
There are four port locks on the front of the housing. Each Port
Lock has a Release Button. Lift the release button and slide each
ort Lock away from the
P port opening before installing the port. In the unlocked position, the
elease Button will remain
R in the up or open position as shown.
The housing port seal is a piston seal and requires that the housing/port o-ring be lightly lubricated for easy installation. Put a small amount of lubricant on your fingers and gently pull the o-ring through your fingers to lightly lubricate it. Do not stretch the o-ring. Check that the lip of the Port Body where the o-ring fits and the sealing surface on the housing are clean. Place the o-ring back onto the Port Body. Place the port and o-ring into the housing’s port opening. Press down on the port firmly and evenly until you feel the port slide into place. Continue to push down on the port. Using your other hand, push each port lock forward. The Release Button on the port lock will drop down and click into the locked position. VViissuuaallllyy cchheecckk tthhee ppoorrtt lloocckkss are in the down and locked position. Do not rely solely on the audible click when pushing each port lock in.
before each dive to make sure they
MMaaiinntteennaanncce
e
After each dive, the exterior of the housing and Port should be rinsed thoroughly in fresh water and dried with a soft cloth. Remove any water spots from the port assembly faceplate as they can cause blurry spots in the photographs.
After prolonged saltwater use, the exterior of the Port and housing should be soaked in a mild non-abrasive liquid soap and water solution. Rinse thoroughly and dry with a soft cloth.
IIkkeelliittee LLiimmiitteedd WWaarrrraannttyy
All Ikelite products are warranted against any manufacturing defects for a period of one year from the original date of purchase. Defective products should be returned prepaid to Ikelite. Ikelite
ill, at its discretion, repair or replace such products, and will
w return to customer prepaid. All other claims of any nature are not covered. Housing is pressure tested and warranted to 200’ (60m) maximum underwater depth. Except as mentioned above, no other warranty expressed or implied, applies to this Ikelite product.
CChheecckk aarroouunndd tthhee ppeerriimmeetteerr ooff tthhee ppoorrtt sseeaall
to see that the o-ring
is properly sealed and not extruded.
9
RReettuurrnniinngg PPrroodduuccttss ffoorr SSeerrvviiccee
Ikelite is most interested in preforming any service to assure that all products perform as intended. For repair or service, return the product to the address below with your name, address, phone number and a brief description of the problem. Evidence of purchase date must be provided to obtain warranty service. Normal service turnaround time is approximately 2-3 weeks.
IIkkeelliittee UUnnddeerrwwaatteerr SSyysstteemmss
5500 WW 3333rrdd SSttrreeeett
IInnddiiaannaappoolliiss,, IINN 4466220088 UUSSAA
WWhheenn rreettuurrnniinngg pprroodduuccttss,, sseennddaattttnn.. RReeppaaiirr DDeepptt..
10
331177--992233--44552233
ggeenneerraall qquueessttiioonnss ee--mmaaiill:: iikkeelliittee@@iikkeelliittee..ccoomm
wwwwww..iikkeelliittee..ccoomm
MMoodduullaarr FFllaatt PPoorrtt--0022--00221100
Loading...