IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANTE: LEA Y GUARDE ESTAS INSTRUCCIONES.
SÓLO PARA USO RESIDENCIAL.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LI305D/W10502582F
RANGE HOOD
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories or service, call: 1-866-664-2449.
In Canada, for assistance, installation and service, call: 1-866-664-2449.
CAMPANA PARA COCINA CON ESCUDETE DE
MONTAJE EN LA PARED DE 30" (76,2 CM)
Instrucciones de instalación y Manual de uso y cuidado
Si tiene preguntas respecto a las características, funcionamiento, rendimiento, partes, accesorios o servicio técnico, llame al: 1-866-664-2449.
HOTTE DE CUISINIÈRE À MONTAGE MURAL DE
30" (76,2 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour assistance, installation ou service, composez le 1-866-664-2449.
Table of Contents/Índice/Table des matières..................................................................2
For warranty concerns, do not take the appliance back to the store. Please contact us in U.S.A. or Canada at 1-866-664-2449.
This product features a Limited Warranty - See the “Warranty” section for complete details. IKEA® appliances carry a 5-year warranty
(excludes LAGAN family - see warranty for coverage details).
NOTE: Proof of Purchase is required to obtain warranty service.
Si tiene dudas acerca de la garantía, no devuelva el aparato a la tienda. Póngase en contacto con nosotros en los EE.UU. o en Canadá
al 1-866-664-2449.
Este producto tiene una garantía limitada - Consulte la sección “Garantía” para obtener todos los detalles. Los aparatos IKEA® tienen
una garantía de 5 años (excluyendo los de la familia LAGAN - consulte la garantía para ver los detalles acerca de la cobertura).
NOTA: Se requiere la prueba de compra para obtener servicio bajo la garantía.
Pour toute question concernant l’application de la garantie, ne pas rapporter l’appareil au magasin. Veuillez nous contacter aux É.-U.
ou au Canada au 1-866-664-2449.
Ce produit est couvert par une garantie limitée – Voir la section “Garantie” pour des détails complets. Les appareils IKEA
par une garantie de 5 ans (hormis les appareils de la série LAGAN - voir la garantie pour des détails concernant les modalités de
garantie).
REMARQUE : Une preuve d’achat est obligatoire pour obtenir l'application de la garantie.
®
sont couverts
TABLE OF CONTENTS
RANGE HOOD SAFETY .................................................................3
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
4
INSTALLATION REQUIREMENTS
†®TORX and T20 are registered trademarks of Acument intellectual properties, LLC.
20"
(50.8 cm)
30" (76.2 cm)
13³⁄₁₆"
(33.5 cm)
10⁷⁄₈"
(27.6 cm)
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools needed
■ Level
■
Drill with 1¼" (3.2 cm),
■ Pencil
■ Wire stripper or utility knife
■ Tape measure or ruler
■ Pliers
■ Caulking gun and weatherproof caulking compound
■ Vent clamps
■ Jigsaw or keyhole saw
■ Flat-blade screwdriver
■ Metal snips
■ Phillips screwdriver
Parts needed
■ Home power supply cable
■ ½" (12.7 mm) UL listed or CSA approved strain relief
■ 3 UL listed wire connectors
For vented installations, you will also need:
■ 1 wall or roof cap
■ Metal vent system
For non-vented (recirculating) installations, you will also need:
■ Charcoal Filter Kit Part Number W10412939 for non-vented
(recirculating) installations only. See “Assistance or Service”
section to order.
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof
or wall. For non-vented (recirculating) Installation see “For
non-vented (recirculating) installation only” in the “Connect Vent
System” section. Charcoal Filter Kit Part Number W10412939
is available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
Parts supplied
Remove parts from packages. Check that all parts are included.
■ Hood canopy assembly with blower, light bulb and canopy
glass already installed
■ Vent transition
■ Metal grease filter
■ Vent cover support bracket
■ Mounting template
■ 2-piece vent cover
■ Air deflector (for non-vented [recirculating] installations only)
■ 8 - 4.2 x 8 mm screws (T20
■ 6 - 5 x 45 mm mounting screws (#2 Phillips drive)
■ 2 - 8 x 40 mm wall anchors (masonry)
■ 4 - 10 x 60 mm wall anchors
■ 4 - 5.4 x 75 mm screws (for 10 x 60 mm wall anchors)
■ T10 Torx
■ T20
■ 2 - 3.5 x 9.5 mm screws (T10 drive)
®†
adapter
®
Tor x® adapter
®†
drive)
5
*For non-vented (recirculating) installations
17³⁄₁₆" (43.7 cm)
**27¹⁄₈" (68.9 cm) min.
**41¹⁄₈" (104.5 cm) max.
*27¹⁄₈" (68.9 cm) min.
*45¹⁄₂" (115.6 cm) max.
10" (25.4 cm) min.
13" (33.0 cm) max.
9¹⁄₂" (24.1 cm)
2" (5.1 cm) min.
9" (22.9 cm) min.*
Centerline
Side
cabinet
Side
cabinet
Vent and power
supply cable
entry location
20" (50.8 cm)* min.
30" (76.2 cm) or
36" (91.4 cm)
“X”
bottom of
canopy
to cooking
surface
10" (25.4 cm) min.
13" (33.0 cm) max.
Cooking surface
**For vented installations
Cabinet Dimensions
*For non-vented (recirculating) installations
IMPORTANT:
Minimum distance “X”: 24" (61.0 cm) from electric cooking
surface
Minimum distance “X”: 27" (68.6 cm) from gas cooking
surface
Suggested maximum distance “X”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights.
See the following chart.
Vented Installations
Min. ceiling heightMax. ceiling height
Electric cooking
7' 4" (2.23 m)9' 5" (2.87 m)
surface
Gas cooking
7' 7" (2.31 m)9' 5" (2.87 m)
surface
Non-vented (recirculating) Installations
Min. ceiling heightMax. ceiling height
Electric cooking
7' 4" (2.23 m)9' 9" (2.97 m)
surface
Gas cooking
7' 7" (2.31 m)9' 9" (2.97 m)
surface
NOTE: The range hood chimneys are adjustable and designed to
meet varying ceiling or soffit heights depending on the distance
“X” between the bottom of the range hood and the cooking
surface. For higher ceilings, a Stainless Steel Chimney Extension
Kit Part Number W10294735 is available from your dealer or an
authorized parts distributor. The chimney extension replaces the
upper chimney shipped with the range hood.
Venting Requirements
(vented models only)
■ Vent system must terminate to the outdoors except for
non-vented (recirculating) installations.
■ Do not terminate the vent system in an attic or other
enclosed area.
■ Do not use 4" (10.2 cm) laundry-type wall cap.
■ Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
■ The length of vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the Most Efficient and Quiet Operation:
■ Use no more than three 90° elbows.
■ Make sure there is a minimum of 24" (61 cm) of straight
vent between the elbows if more than 1 elbow is used.
■ Do not install 2 elbows together.
■ Use clamps to seal all joints in the vent system.
■ The vent system must have a damper. If the roof or wall
cap has a damper, do not use the damper supplied with
the range hood.
■ Use caulking to seal exterior wall or roof opening around
the cap.
■ The size of the vent should be uniform.
6
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the
vent system enters the heated portion of the house.
A
A
B
B
B
A
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in
your area.
Venting Methods
This canopy hood is factory set for venting through the roof
or wall.
A 6" (15.2 cm) round vent system is needed for installation
(not included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall.
To vent through a wall, a 90° elbow is needed.
Rear Discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, fitting a charcoal filter and the deflector. Fumes and
vapors are recycled through the top grille.
Roof VentingWall VentingNon-Vented
(Recirculating)
A. Roof cap
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A. Deflector
B. 6" (15.2 cm)
round vent
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece6" (15.2 cm) Round
45° elbow2.5 ft
(0.8 m)
90° elbow5.0 ft
(1.5 m)
Example Vent System
The following example falls within the maximum recommended
vent length of 35 ft (10.7 m).
1 - 90° elbow= 5.0 ft (1.5 m)
1 - wall cap= 0.0 ft (0.0 m)
8 ft (2.4 m) straight= 8.0 ft (2.4 m)
Length of system= 13.0 ft (3.9 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
■ A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit
is required.
■ If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
■ Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial/rating plate.
The model/serial/rating plate is located behind the left filter
on the rear wall of the range hood.
■ Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1
and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
Maximum equivalent vent length is 35 ft (10.7 m).
7
INSTALLATION INSTRUCTIONS
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
■ It is recommended that the vent system be installed before
hood is installed.
■ Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
■ Check your ceiling height and the hood height maximum
before you install your hood. See “Cabinet Dimensions”
in the “Location Requirements” section for details.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or
non-vented.
3. Select a flat surface for assembling the range hood.
Place covering over that surface.
4. Using 2 or more people, lift range hood onto covered surface.
5. For wood, drill ³⁄₁₆" (4.8 mm) pilot holes at all locations
where screws are being installed into wood.
For wall anchors, drill ⁷⁄₁₆" (10 mm) holes at all locations
where wall anchors are being used.
6. For wood, install (2) 5 x 45 mm mounting screws. Leave
a ¹⁄₄" (6.4 mm) gap between the wall and the back of the
screw head to slide range hood into place.
For wall anchors, install the 10 x 60 mm wall anchors
and install the 5.4 x 75 mm screws into the wall anchors.
Tighten until the wall anchors are secure. Back the
screws out ¹⁄₄" (6.4 mm).
Vent Cover Bracket Installation
7. Attach vent cover bracket to wall flush to the ceiling using
(2) 5 x 45 mm #2 Phillips screws. Use optional wall anchors
if needed.
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the wall where
the canopy hood will be installed.
2. Select a mounting height between a minimum of 24"
(61.0 cm) for an electric cooking surface, a minimum of
27" (68.6 cm) for a gas cooking surface, and a suggested
maximum of 36" (91.4 cm) above the range to the bottom
of the hood. Mark a reference line on the wall.
3. Tape template in place, aligning the template centerline
and bottom of template with hood bottom line and with
the centerline marked on the wall.
A. Centerline
B. Fastener locations
C. Mounting height reference (hood bottom line)
4. Mark centers of the fastener locations through the template
to the wall.
IMPORTANT: All canopy mounting screws must be installed
into wood where possible. If there is no wood to screw into,
additional wall framing supports may be required, or use the
(4) 10 x 60 mm wall anchors and 5.4 x 75 mm screws.
8
Remove the template.
A. Ceiling
B. Wall
C. Centerline
Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See “Venting Requirements” section.
2. Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
3. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough ½" conduit and wires
from the fused disconnect (or circuit breaker) box to make
the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
Install Range Hood
B
C
A
B
A
A
B
C
X
A
C
D
B
E
1. Remove screws from wooden shipping supports. Properly
dispose of shipping materials.
2. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket using
(4) 4.2 x 8 mm T20
®
screws. Use T20® Tor x® drive (or T20®
adapter provided) to tighten.
A. Assembly screws
B. Air deflector
C. Duct cover bracket
2. Measure from the bottom of the air deflector to the bottom
of the hood outlet.
3. Remove the grease filter. See “Range Hood Care” section.
4. Level the range hood and tighten upper mounting screws.
5. Install (2) 5 x 45 mm #2 Phillips lower mounting screws and
tighten. Use optional wall anchors if needed.
Connect Vent System
1. Install transition on top of hood (if removed for shipping) with
(2) 3.5 x 9.5 mm T10 sheet metal screws. Use T10 Torx
(or T10 adapter provided) to tighten.
A. Vent transition
B. 3.5 x 9.5 mm screw
®
drive
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
3. Cut the duct to the measured size “X.”
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over the exhaust
outlet from the hood.
7. Reassemble the air deflector to the duct cover bracket with
the 4 assembly screws.
8. Seal connections with vent clamps.
For vented installations only:
1. Fit vent system over the exhaust outlet.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
9
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
C
B
A
A
B
C
D
E
F
G
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
C
A
B
5. Use UL listed wire connectors and connect black
wires (E) together.
6. Use UL listed wire connectors and connect white
wires (D) together.
1. Disconnect power.
2. Remove terminal box cover using a T10 Torx
(or the T10 adapter provided) to remove screws.
3. Remove the knockout in the terminal box and install
a UL listed or CSA approved ¹⁄₂" strain relief.
A. Terminal box
B. Knockout
C. Terminal box cover
4. Run home power supply cable through strain relief
into terminal box.
®
drive
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Vent Covers
When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling. Install
with (2) 4.2 x 8 mm T20® screws using a T20® Torx® drive
®
(or T20
NOTE: For vented installations, the upper vent cover may
be reversed to hide slots.
adapter provided) to tighten.
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. UL listed wire connectors
D. White wires
E. Black wires
10
F. Green (or bare) and yellow-green ground wires
G. Terminal box
A. Bracket
B. 4.2 x 8 mm T20
C. Vent cover
®
screws
Secure the bottom of the duct with (2) 4.2 x 8 mm T20® screws
A
B
C
D
E
F
G
H
A
B
C
D
E
using a T20
®
Torx® drive (or T20® adapter provided) to tighten.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the
hood before cooking and allow it to operate several minutes
after the cooking is complete to clear all smoke and odors
from the kitchen.
The hood controls are located on the front side of the canopy.
Complete Installation
1. For non-vented (recirculating) installations only, install
charcoal filters over metal grease filter. See the “Range
Hood Care” section.
2. Install metal filters. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and light.
See the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range
hood, read the “Range Hood Use” section.
Range Hood Controls
A. On/Off light button
B. Blower off button
C. Blower speed minimum button
D. Blower speed medium button
E. Blower speed maximum button
Operating the Light
The On/Off Light button controls both lights. Press once for
On and again for Off.
Operating the Blower
The Blower Speed buttons turn the blower on and control the
blower speed and sound level for quiet operation. The speed
can be changed anytime during fan operation by pressing the
desired Blower Speed button.
The Blower Off button turns the blower Off.
A. Duct cover holes
B. Duct cover
C. Control panel
D. Glass canopy
E. Grease filter
F. Lamp cover
G. Incandescent lamp (position
and number of lamps may vary)
H. Grease filter release handle
11
RANGE HOOD CARE
A
Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool
or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
■ Liquid detergent soap and water or all-purpose cleanser
■ Wipe with damp soft cloth or nonabrasive sponge, and
then rinse with clean water and wipe dry.
4. Bend spring clips back into place to secure the charcoal
filter to the metal filter.
5. Replace metal grease filter. See “Metal Grease Filter”
in this section.
Metal Grease Filter:
1. Remove the filter by pulling the spring release handle
and then pulling down the filter.
A. Spring release handle
2. Wash metal filters as needed in dishwasher or hot detergent
solution.
3. Reinstall the filter by making sure the spring release handles
are toward the front. Insert aluminum filter into upper track.
4. Push in spring release handle.
5. Push up on metal filter and release handle to latch into place.
Non-Vented (Recirculating) Installation Filters:
The charcoal filter is not washable. It should last up to 6 months
with normal use. Replace with Charcoal Filter Kit Number
W10412939.
To Replace Charcoal Filter:
1. Remove metal grease filter from range hood. See “Metal
Grease Filter” in this section.
2. Bend spring clips away from metal grease filter.
Replacing a Lamp
Turn off the range hood and allow the lamp to cool. To avoid
damage or decreasing the life of the new bulb, do not touch
bulb with bare fingers. Replace bulb, using tissue or wearing
cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Use a Phillips screwdriver to remove screw from lamp cover.
3. Remove lamp cover and set lamp cover and the screw aside.
4. Remove bulb and replace with a new 120 volt, 40 watt
maximum E-12 bulb.
3. Place charcoal filter into top side of metal filter.
5. Replace lamp cover and reinstall screw.
6. Reconnect power.
12
WIRING DIAGRAM
SE13FC
M
BU
BU
WH
RD
BK
GY
YL
BR
YL
YL/GN
YL/GN
BK
WH
BK
WH
RD
BU
YL
NL1Gnd
YL/GN
La
Z
YL
BK
RD
WH
BR
WH
YL
BK
RD
WH
YL/GN
BK
BU
BR
Push Button Switch
Off
Lamps
Low Speed
No connection
Brown - Yellow
(L - LA)
PositionFunction
Switch Operation
High Speed
Med Speed
Brown - Black
(L - 3)
Brown - Red
(L - 2)
Brown - White
(L - 1)
Motor Resistance
(Ohms)
Blue - Black
Blue - Gray
Blue - Red
Blue - White
Room Temp.
37.7
73.4˚F (23˚C)
45.1
30.3
28.8
Motor
Characteristics
Power Supply
Frequency
Power Absorption
120 VAC
60 Hz
240 Watts
GY
1
23L
L
13
ASSISTANCE OR SERVICE
Before calling for assistance or service, please check to see
whether a circuit breaker has tripped or a household fuse has
blown. It may save you the cost of a service call. If you still need
help, follow the instructions below.
When calling, please know the purchase date and the complete
model and serial number of your appliance. This information will
help us to better respond to your request.
If you need replacement parts
If you need to order replacement parts, we recommend that
you use only factory specified
will fit right and work right because they are made with the
same precision used to build every new IKEA
To locate factory specified parts in your area, call us or your
nearest designated service center.
Call the Whirlpool Customer eXperience Center toll free:
1-866-664-2449.
Our consultants provide assistance with:
■ Features and specifications on our full line of appliances.
■ Referrals to local dealers, repair parts distributors, and
service companies. Whirlpool designated service technicians
are trained to fulfill the product warranty and provide afterwarranty service anywhere in the United States.
To locate the Whirlpool designated service company in
your area, you can also look in your telephone directory
Yellow Pages.
For further assistance
If you need further assistance, you can write to Whirlpool
Corporation with any questions or concerns at:
IKEA Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
parts. Factory specified parts
®
appliance.
In the U.S.A.
In Canada
Call the Whirlpool Canada LP Customer eXperience Centre
toll free: 1-866-664-2449.
Our consultants provide assistance with:
■ Features and specifications on our full line of appliances.
■ Use and maintenance procedures.
■ Accessory and repair parts sales.
■ Referrals to local dealers, repair parts distributors, and
service companies. Whirlpool Canada LP designated service
technicians are trained to fulfill the product warranty and
provide after-warranty service anywhere in Canada.
For further assistance
If you need further assistance, you can write to Whirlpool
Canada LP with any questions or concerns at:
Customer eXperience Centre
Whirlpool Canada LP
200 – 6750 Century Ave.
Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.
Accessories
Charcoal Filter Kit
(for non-vented installations only)
Order Part Number W10412939
Chimney Extension Kit
Order Part Number W10294735
6" (15.2 cm) Makeup Air Kit
(consult local building codes)
Order Part Number W10446915
14
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.