Table of Contents/Table des matières.............................................................................2
IMPORTANT:
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
Save installation instructions for local electrical inspector's use.
IMPORTANT :
Installateur : Remettre les instructions d'installation au propriétaire.
Propriétaire : Conserver les instructions d'installation pour référence ultérieure.
Conserver les instructions d'installation pour consultation par l'inspecteur local des installations électriques.
501961066054C
Page 2
TABLE OF CONTENTS
TABLE DES MATIÈRES
RANGE SAFETY .............................................................................2
CONVERSIONS POUR CHANGEMENT DE GAZ.......................30
Conversion pour l'alimentation au propane ..............................30
Conversion pour l'alimentation au gaz naturel ..........................31
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
follow instructions.
can be killed or seriously injured if you don't
You
instructions.
follow
2
Page 3
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
•
Do not touch any electrical switch.
•
Do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
•
instructions.
If you cannot reach your gas supplier, call the fire department.
•
– Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.
In the State of Massachusetts, the following installation instructions apply:
■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
■ If using a ball valve, it shall be a T-handle type.
■ A flexible gas connector, when used, must not exceed 3 feet.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect wall anti-tip brackets to wall behind range.
Connect range anti-tip brackets to underside of range.
Re-engage the anti-tip brackets, if the range is moved.
See the installation instructions for details.
Failure to follow these instructions can result in death or serious burns to children and adults.
3
Page 4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tool s n e ed e d
■ Tape measure
■ Flat-blade screwdriver
■ Phillips screwdriver
■ Level
■ Hand or electric drill
■ ¹⁄₄" drill bit (for wall)
■ Hammer
■ Wrench or pliers
■ Pipe wrench
Parts supplied
Check that all parts are included.
■ CSA approved strain relief (U.S.A. only)
■ Marker or pencil
■ Masking tape
■ Pipe-joint compound
resistant to LP gas
■ Noncorrosive leak-detection
solution
For LP/Natural Gas
Conversions
■ ½" combination wrench
■ 7 mm combination wrench
■ 7 mm nut driver
■ Anti-tip bracket assembly
A
C
A. Wall anti-tip brackets (2)
B. Range anti-tip bracket (2)
C. Plastic drywall anchors (4)
D. Screws (12)
B
D
Wall anti-tip brackets must be securely mounted to the rear
wall, and range anti-tip brackets must be securely attached
to the rear underside of the range.
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See “Electrical Requirements” and
“Gas Supply Requirements” sections.
B
A
A. Strain relief screws
B. Washers
C. Attachment screws
■ CSA approved conduit connector (U.S.A. only)
A
B
A. Conduit connector
B. Conduit connector attachment
screws and washers
C
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
■ It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located inside the oven door on
the right-hand side oven door trim.
■ The range should be located for convenient use in the
kitchen.
■ Recessed installations must provide complete enclosure of
the sides and rear of the range.
■ To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
or microwave hood combination that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
■ All openings in the wall or floor where range is to be installed
must be sealed.
■ Do not seal the range to the side cabinets.
■ Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
4
Page 5
■ The wall anti-tip bracket assembly (wall anti-tip brackets and
B
range anti-tip brackets) must be installed. To install the antitip brackets shipped with the range, see “Install Range AntiTip Brackets” and “Install Wall Anti-Tip Bracket” sections.
■ Grounded electrical supply is required. See “Electrical
Requirements” section.
■ Proper gas supply connection must be available. See “Gas
Supply Requirements” section.
■ Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
■ Use an insulated pad or ¼" (0.64 cm) plywood under range if
installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194° (90°C).
Product Dimensions
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Mobile home installations require:
■ When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
■ Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be
revised. See “Electrical Connection” section.
A. 35¹⁄₄" (89.5 cm)
B. Model/serial number plate
(located inside the oven
door on the right-hand side
oven door trim)
A
C
C. Adjustable legs 5³⁄₄" min. to 9¹⁄₁₆"
max. (14.6 cm min. to 23.0 cm max.)
D. 1" (2.5 cm)
E. 23⁵⁄₈" (60.0 cm)
D
E
H
F
G
L
I
J
C
K
F. 2 9 ¹⁄₂" (75.0 cm)
G. 1⁵⁄₈" (4.0 cm)
H. Front panel
I. Oven door
J. 35¹⁄₄" to 37⁷⁄₈" max. (89.5 cm to 96.2 cm
max.)
K. 40⁹⁄₁₆" +/- ¹⁄₈" (103.0 cm +/- 2.5 mm)
L. 5³⁄₄" min. to 9¹⁄₁₆" max. (14.6 cm min. to
23.0 cm max.)
5
Page 6
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm)
countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood
combination installation instructions for dimensional clearances above the cooktop surface.
A. 18" (45.7 cm) upper cabinet to countertop
B. 13" (33.0 cm) upper cabinet depth
C. 35¹⁄₂" (90.1 cm) min. opening width
D. For minimum clearance to top of the cooktop, see NOTE.
E. 35¹⁄₄" (89.5 cm) min. opening width
F. This shaded area recommended for installation of rigid gas pipe.
G. 8" (20.3 cm) available area for gas and electric installation
H. This shaded area recommended for installation of outlet or junction
box.
I. 7" (17.8 cm)
J. 1¹⁄₂" (3.8 cm)
M
K. 4¹⁄₂" (11.4 cm)
L. 5" (12.7 cm) min. clearance from both sides of the range to the
side wall or other combustible material.
M. Cabinet door or hinge should not extend into the cutout.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is protected by not less than ¹⁄₄" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an unprotected wood or metal
cabinet.
Electrical Requirements - U.S.A. Only
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge is in accordance
with local codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
This range is manufactured with the neutral terminal connected
to the cabinet. Use a 3-wire, UL listed, 40-amp power supply
cord (pigtail) kit; or if local codes do not permit ground through
the neutral, use a 4-wire power supply cord rated at 250 volts,
40 amps and investigated for use with ranges.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
■ Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial rating plate is located inside the oven
door on the right-hand side oven door trim. See the following
illustration.
A
A. Model/serial number plate
■ When a 4-wire or 3-wire, single phase 120/240 volt, 60 Hz,
AC only electrical supply is available, a 50-amp maximum
circuit protection is required. When a 4-wire or 3-wire single
phase 120/208 volt 60 Hz, AC only electrical supply is
available, a 40-amp maximum circuit protection is required,
fused on both sides of the line.
6
Page 7
■ A time-delay fuse or circuit breaker is recommended.
■ The range can be connected directly to the fused disconnect
(or circuit breaker box) through flexible or nonmetallic
sheathed, copper or aluminum cable. See “Electrical
Connection.”
■ Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
■ A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction
box).
■ Wire sizes and connections must conform with the rating of
the range (40 amps).
■ The tech sheet is located on the rear panel of the range in a
clear plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
cabinet. The ground must be revised so the green ground wire of
the 4-wire power supply cord is connected to the cabinet. See
“Electrical Connection.”
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250 volt, 40-amp, range power supply
cord (pigtail) kit must be used. This cord contains 4 copper
conductors with ring terminals or open-end spade terminals with
upturned ends, terminating in a NEMA Type 14-50R plug on the
supply end.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
Electrical Requirements - Canada Only
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Be sure that the electrical connection and wire size are adequate
and in conformance with the CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.
■ Check with a qualified electrical installer if you are not sure
the range is properly grounded.
■ When a 4-wire, single phase 120/240 volt, 60 Hz., AC only
electrical supply is available, a 50-amp maximum circuit
protection is required (or, if specified on the model/serial
rating plate, when a 4-wire, single phase 120/208 volt, 60 Hz.,
AC only electrical supply is available, a 40-amp maximum
circuit protection is required), fused on both sides of the line.
■ A time-delay fuse or circuit breaker is recommended.
■ This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range’s final location.
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire,
250 volt, 40-amp range power supply cord (pigtail) kit. This cord
contains 3 copper conductors with ring terminals or open-end
spade terminals with upturned ends, terminating in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)
■ Do not use an extension cord.
7
Page 8
WARNING
Gas Supply Requirements
Flexible metal appliance connector:
■ If local codes permit, a new CSA design-certified,
4 - 5 ft (122 - 152.4 cm) long, ½" (1.3 cm) or
¾" (1.9 cm) I.D., flexible metal appliance connector may
be used for connecting range to the gas supply line.
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT: Leak testing of the range must be conducted
according to the manufacturer’s instructions.
Type of Gas
Natural gas:
This range is design-certified by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
■ This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial rating plate located
inside the oven door on the right-hand side oven door trim
has information on the types of gas that can be used. If the
types of gas listed do not include the type of gas available,
check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See “Gas
Conversions” section.
Gas Supply Line
■ Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the
range location. A smaller size pipe on longer runs may result
in insufficient gas supply. Pipe-joint compounds that resist
the action of LP gas must be used. Do not use TEFLON
tape. With LP gas, piping or tubing size can be ½" (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and
materials used in the system.
®†
■ A ½" (1.3 cm) male pipe thread is needed for connection
to the female pipe threads of the inlet to the appliance
pressure regulator.
■ Do not kink or damage the flexible metal tubing when
moving the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe
fittings to obtain an in-line connection to the range. The rigid
pipe must be level with the range connection. All strains must
be removed from the supply and fuel lines so range will be
level and in line.
■ Must include a shutoff valve:
The supply line must be equipped with a manual shutoff
valve. This valve should be located in the same room but
external to the range. It should be in a location that allows
ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the
range.
B
A
C
A. Gas supply line
B. Shutoff valve “open” position
C. To range
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be
used. The inlet pressure to the regulator should be as follows for
proper operation:
Natural gas:
Minimum pressure: 5" WCP
Maximum pressure: 13" WCP
LP gas:
Minimum pressure: 11" WCP
Maximum pressure: 13" WCP
Contact local gas supplier if you are not sure about the inlet
pressure.
8
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Page 9
Burner Input Requirements
Gas Supply Pressure Testing
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level (not
applicable for Canada).
INSTALLATION INSTRUCTIONS
Unpack Range
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. Remove shipping materials, tape and protective film from the
range. Remove oven racks and parts package from inside
oven.
2. Place the top sheet of polystyrene foam from the packaging
lengthwise on the floor behind the range to support the range
when it is laid on its back. Using 2 or more people, firmly
grasp the range and gently lay it on its back on the
polystyrene foam.
Line pressure testing above ½ psi gauge (13" WCP)
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (13" WCP) or lower
The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
Attach Leveling Legs
1. Remove the 4 leveling legs from the parts package.
2. To attach the leveling legs, screw 1 leg clockwise into the
threaded hole located at each corner underneath the range.
Install Range Anti-Tip Brackets
1. Use the 8 screws provided to securely attach range anti-tip
brackets to each rear corner of the range.
A
B
A. Range anti-tip bracket (2)
B. 8 screws (4 per bracket)
Adjust Leveling Legs
1. If range height adjustment is necessary, manually adjust
the leveling leg sleeves to loosen the 4 leveling legs.
Leveling legs can be loosened to add up to a maximum of
5³⁄₄" (14.6 cm).
This may be done with the range on its back or with the range
supported on 2 legs after the range has been placed back to
a standing position.
A
A. Leveling leg sleeves
NOTE: To place range back up to a standing position, put a
sheet of cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto the cardboard or
hardboard.
9
Page 10
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect wall anti-tip brackets to wall behind range.
Connect range anti-tip brackets to underside of range.
Re-engage the anti-tip brackets, if the range is moved.
See the installation instructions for details.
Failure to follow these instructions can result in death
or serious burns to children and adults.
2. When the range is at the correct height, check that there is
adequate clearance between the range and wall to install the
anti-tip brackets. Before sliding range into its final position,
install anti-tip brackets.
Level Range
1. Place a rack in oven.
2. Place level on rack to check levelness of range, first side to
side, then front to back.
A
B
C
A. Centerline
B. 27½” (70.0 cm)
C. Determine distance from bottom of range
anti-tip brackets to floor and add ⁵⁄₈" (16.0 mm).
2. Measure distance from bottom of range anti-tip brackets to
floor, add ⁵⁄₈" (16.0 mm) to the distance and mark on the rear
wall of the cutout.
3. Measure out 13⁵⁄₈" (34.6 cm) right and left of the centerline (A)
made in Step 1 and mark the intersection to determine
placement of top of each bracket.
4. Securely attach the wall anti-tip brackets to the rear wall of
the cutout with drywall anchors and screws provided.
A
3. If the range is not level, pull range forward.
4. Manually adjust the leveling legs up or down. Turn leveling leg
sleeves to level range and to raise or lower range to the
desired countertop height.
NOTE: Range must be level for satisfactory baking
performance.
5. Continue installing your range using the following installation
instructions.
Install Wall Anti-Tip Brackets
Before moving range, slide range onto shipping base, cardboard
or hardboard.
1. Using a measuring tape, find and clearly mark the vertical
centerline on the wall of the range location. Use the
dimensions provided below to determine the position of the
wall anti-tip brackets on the rear wall of the cutout.
B
C
A. Wall anti-tip brackets
B. Drywall anchors
C. Anti-tip screws
5. Move range close enough to wall to allow for final electrical
connection. Remove shipping base, cardboard or hardboard
from under range.
10
Page 11
Electrical Connection - U.S.A. Only
Power Supply CordDirect Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover.
A
C
B
C
D
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
■ Feed the power supply cord through the hole underneath
the terminal block on the bottom of the range. Allow
enough slack to easily attach the wiring to the terminal
block.
A
B
E
A. Terminal block cover
B. Terminal block cover screws
C. Terminal block cover screw holes
D. Power cord insertion hole
E. Terminal block
3. Install strain relief.
Style 1: Power supply cord strain relief
■ Secure the strain relief onto the power supply cord by
tightening the screws with Phillips screwdriver.
NOTE: Allow for 6" minimum from power supply cord
wires to strain relief.
A
B
C
A. Power supply cord wires
B. Screw
C. UL listed strain relief
C
D
E
A. Terminal block
B. Rear of range
C. Power supply cord wires
D. Strain relief
E. Screws
■ Secure strain relief underneath the range by tightening
screws.
11
Page 12
Style 2: Direct wire strain relief
■ Assemble a UL listed conduit connector and conduit
plate.
A
B
Electrical Connection Options
If your home has:And you will be
connecting to:
4-wire receptacle
(NEMA type 14-50R)
A UL listed,
250-volt
minimum,
40-amp, range
power supply
cord
Go to Section:
4-wire connection:
Power supply cord
C
A. Removable retaining nut
B. Conduit plate
C. Strain relief
■ Feed the flexible conduit through the conduit plate.
Securely tighten strain relief screw.
A
B
C
A. Conduit plate
B. Strain relief screw
C. Flexible conduit
■ Feed wires through the hole underneath the terminal
block on the bottom of the range. Allow enough slack to
easily attach the wiring to the terminal block. Secure the
conduit plate underneath the range by tightening screws.
A
B
4-wire directA fused
disconnect or
5"
(12.7 cm)
3-wire receptacle
(NEMA type 10-50R)
circuit breaker
box
A UL listed,
250-volt
4-wire connection:
Direct wire
3-wire connection:
Power supply cord
minimum,
40-amp, range
power supply
cord
3-wire directA fused
1"
(2.5 cm)
disconnect or
circuit breaker
3-wire connection:
Direct wire
box
3"
(7.6 cm)
4-wire connection: Power Supply Cord
Use this method for:
■ New branch-circuit installations (1996 NEC)
■ Mobile homes
■ Recreational vehicles
■ An area where local codes prohibit grounding through the
neutral
1. Remove the ground-link screw from the range frame. Save
the ground link screw and cup washer. Bend the ground-link
away from the range so that it does not contact the range.
C
E
A. Terminal block
B. Rear of range
C. Wires
D. Strain relief
E. Screws
4. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
12
C
D
B
A
A. Ground-link screw
B. Cup washer
C. Ground-link bent away from range
2. Connect the green ground wire from the power supply cord to
the range using the ground-link screw. The ground wire must
be attached first and must not contact any other terminal.
3. Use a ¼" nut driver and remove the hex washer head screws
from the terminal blocks.
Page 13
4. Connect the neutral (center) wire to the center terminal
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
E
D
C
F
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or
circuit breaker box. Depending on your electrical supply, make
the required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 1" (2.5 cm) from the end of each wire.
1"
(2.5 cm)
B
G
H
A
I
A. Line 1
B. Green ground wire
C. Ground-link screw
D. Hex washer head
screw
E. Silver-colored terminal
block screw
F. Ground-link
G. Neutral (center) wire
H. Line 2
I. UL listed strain relief
and 40-amp range
power supply cord
5. Connect the other 2 wires (lines 1 and 2) to the outer
aluminum terminal blocks.
6. Securely tighten screws for proper electrical connection.
7. Tighten strain relief screws.
8. Replace terminal block cover.
3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting cabinetground conductor to neutral wire of power supply cord.
1. Use a ¼" nut driver and remove the hex washer head screws
from the aluminum terminal blocks.
2. Connect the neutral (center) wire to the center terminal
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
D
C
E
B
F
A
G
A. Line 1
B. Ground-link
C. Hex washer head screw
D. Silver-colored terminal
block screw
E. Neutral (center) wire
F. Line 2
G. UL listed strain relief
and 40-amp range power
supply cord
3"
(7.6 cm)
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete electrical connection according to your type of
electrical supply (4-wire or 3-wire connection).
4-wire Connection: Direct Wire
Use this method for:
■ New branch-circuit installations (1996 NEC)
■ Mobile homes
■ Recreational vehicles
■ An area where local codes prohibit grounding through the
neutral
1. Remove the ground-link screw from the range frame. Save
the ground-link screw and cup washer. Bend the ground-link
away from the range so that it does not contact the range.
C
B
A
A. Ground-link screw
B. Cup washer
C. Ground-link bent away from range
2. Connect the bare ground wire to the range using the ground-
link screw and cup washer. The ground wire must be
attached first and must not contact any other terminal.
D
C
E
F
B
A
G
3. Connect the other 2 wires (lines 1 and 2) to the outer terminal
screws on the terminal block.
4. Tighten strain relief screws.
5. Replace terminal block cover.
A. Bare wire from power
supply cable
B. Line 1
C. Hex washer head screw
D. Silver-colored terminal
block screw
E. Line 2
F. Neutral (white) wire
G. UL listed conduit
connector and power
supply cable
13
Page 14
3. Loosen (do not remove) the hex washer head screw and
B
B
insert the neutral (white) wire under the screw clamp at the
bottom of the center position terminal connector.
4. Insert the other 2 wires (lines 1 and 2) under the other 2 screw
clamps.
A
A. Insert wire under screw clamp.
B. Hex washer head screw
5. Securely tighten the hex washer head screws to
35 lbs-in. (4.0 N-m) minimum torque to make proper
electrical connection.
6. Tighten the locking ring of the conduit connector.
7. Replace the terminal block cover.
Make Gas Connection
The gas pressure regulator is supplied with the Gas Connection
Kit. Check that all parts are included.
A
B
C
A
D
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Loosen (do not remove) the hex washer head screws and
insert the neutral (white) wire under the screw clamp at the
bottom of the center position terminal connector.
D
C
E
F
B
A
A. Line 1
B. Ground-link
C. Hex washer head screw
D. Silver-colored terminal
block screw
E. Neutral (white) wire
F. Line 2
G. UL listed conduit
connector and power
supply cable
2. Insert the other 2 wires (lines 1 and 2) under the other 2 screw
clamps.
G
E
A. Joint
B. Pipe
C. Plate
D. Adapter
E. Gas pressure regulator
1. Connect the gas pressure regulator to the pipe, using the
adapter.
C
B
A
D
A. Gas pressure regulator
B. Adapter
C. Plate
D. Pipe
2. Securely attach the pipe and plate underneath the range,
using the screws provided.
A
B
A
A. Insert wire under screw clamp.
B. Hex washer head screw
3. Securely tighten the hex washer head screws to
35 lbs-in. (4.0 N-m) minimum torque to make a proper
electrical connection.
4. Tighten the locking ring of the conduit connector.
5. Replace the terminal block cover.
14
C
A. Plate
B. Gas pressure regulator
C. Screws
Page 15
Typical rigid pipe connection
J
A combination of pipe fittings must be used to connect the range
to the existing gas line. Your connections may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound made for use with LP gas to all
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
I
H
3. Remove cooktop burner caps and grates from parts
package. Align notches in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light. Place burner grates over burner and caps.
A
G
B
A
C
A. ½" or ¾" gas pipe
B. Manual gas shutoff valve
C. Nipple
D. Union
E. 90° elbow
F
D
E
F. Black iro n p i p e
G. Union
H. Nipple
I. 90° elbow (must have
½" male pipe thread)
J. Gas pressure regulator
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see C
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
H
E
B
D
F
B
C
D
A. Burner grate
B. Burner cap
C. Burner head
D. Burner base
B
C
D
4. Plug in range or reconnect power. For further information,
please refer to the user instructions located in the Use and
Care Guide.
5. Push range back into its final location. Check that the anti-tip
brackets are engaged.
Electronic Ignition System
Light a Surface Burner
Push in and turn cooktop control knob to the “LITE” position. A
spark will automatically light the burner.
Check Operation of Surface Burners
A
C
A. ½" or ¾" gas pipe
B. Manual gas shutoff valve
C. Use pipe-joint compound
D. Adapter
E. Flexible connector
F. Adapter (must have ½" male
pipe thread)
G. Use pipe-joint compound
H. Gas pressure regulator
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
B
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
G
Push in and turn the surface burners control knobs to the “LITE”
position.
The surface burner flame should light within 4 seconds. The first
time a surface burner is lighted it may take longer than 4 seconds
to light because of air in the gas line.
Check the flame on “HI” for a blue color. It should be clean and
soft in character. No yellow tip, blowing or lifting of flame should
occur. Occasional orange flashes are normal and reflect different
elements in the air or gas.
After verifying the proper burner operation, turn the control knobs
to “OFF.”
If burners do not light properly:
■ Turn surface burner control knob to the “OFF” position.
■ Check that the power supply cord is plugged in and the
circuit breaker has not tripped or the fuse blown.
■ Check that the gas shutoff valves are set to the “open”
position.
■ Check that burner caps are properly positioned on burner
bases.
Recheck operation of surface burners. If a burner does not light
at this point, contact your dealer or authorized service company
for assistance.
15
Page 16
Adjust Flame Height
Adjust the height of surface burner flames.
The surface burner “low” flame should be a steady blue flame
approximately ¼" (0.64 cm) high.
A
B
A. Low flame
B. High flame
If the “low” flame needs to be adjusted:
The flame can be adjusted using the adjustment screw in the
center of the valve stem. The valve stem is located directly
underneath the control knob.
A
A. Adjustment screw
Complete Installation
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check that range level. See “Level Range.”
5. Use a mild solution of liquid household cleaner and warm
water to remove waxy residue caused by protective shipping
material. Dry thoroughly with a soft cloth. For more
information, see the “Range Care” section of the Use and
Care Guide.
6. Read “Range Use” in the Use and Care Guide.
7. Turn on surface burners and oven. See the Use and Care
Guide for specific instruction on range operation.
If range does not operate, check the following:
■ Household fuse is intact and tight, or circuit breaker has not
tripped.
■ Gas valves are turned to the “open” position.
■ If the gas supply line shutoff valve is open, press the OFF
button on the oven control panel and contact a qualified
technician.
■ Electrical supply is connected.
■ See “Troubleshooting” in the Use and Care Guide.
When the range has been on for 5 minutes, check for heat. If
range is cold, turn off the range and contact a qualified
technician.
1. Remove the control knob.
2. Hold the knob stem with a pair of pliers. Use a small flat-
blade screwdriver to turn the screw located in the center of
the control knob stem until the flame is the proper size.
3. Replace the control knob.
4. Test the flame by turning the control from “LO” to “HI,”
checking the flame at each setting.
16
Page 17
GAS CONVERSIONS
C
Gas conversions from Natural gas to LP gas; or from LP gas to
Natural gas must be done by a qualified installer.
2. Unplug range or disconnect power.
B
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
LP Gas Conversion
WARNING
A
A. To range
B. Manual shutoff valve “closed“ position
C. Gas supply line
3. Remove access cover from the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure regulator
4. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
5. Remove sprint retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the “NAT” or “LP” position.
6. Turn over the spring retainer so the “LP” is showing on the
bottom.
7. Snap the spring retainer back into the cap.
8. Reinstall the cap onto the regulator.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect wall anti-tip brackets to wall behind range.
Connect range anti-tip brackets to underside of range.
Re-engage the anti-tip brackets, if the range is moved.
See the installation instructions for details.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the “closed” position.
LP
E
A. Access cap
B. Gasket
C. Gas pressure regulator
A
LP
D
D. Spring retainer LP position
E. Spring retainer NAT position
B
C
17
Page 18
To Convert Standard Surface Burners
A
C
1. Remove burner cap.
2. Remove burner base.
3. Apply masking tape to the end of a 7.0 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
A
A. Orifice spud
4. Gas orifice spuds are stamped with a number on the side.
XXX
Natural Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect wall anti-tip brackets to wall behind range.
Connect range anti-tip brackets to underside of range.
Re-engage the anti-tip brackets, if the range is moved.
See the installation instructions for details.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the “closed” position.
2. Unplug range or disconnect power.
B
A. Stamped number
Refer to the following chart for correct LP gas orifice spud
placement.
LP Gas Orifice Spud Chart for Standard Surface Burners
Burner LocationBurner RatingSize
Right front
Left front
Center
Right rear
Left rear
5. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package.
6. Repeat steps 1-6 for the remaining burners.
7. Replace burner base, burner head and burner cap.
8. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package.
9. Complete installation. See “Make Gas Connection” and
“Electronic Ignition System” sections.
Checking for proper cooktop burner flames is very important.
The small inner cone should have a very distinct blue flame
¼" to ½" long. The outer cone is not as distinct as the inner
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the “LO” setting for
each cooktop burner. See “Make Gas Connection” and
“Electronic Ignition System” section.
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
3. Remove access cover from the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
18
Page 19
Gas pressure regulator
A
4. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
5. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the “LP” or “NAT” position.
6. Turn over the spring retainer so the “NAT” is showing on the
bottom.
7. Snap the spring retainer back into the cap.
8. Reinstall the cap onto the regulator.
4. Gas orifice spuds are stamped with a number on the side.
Replace the LP gas orifice spud with the correct Natural gas
orifice spud.
XXX
A. Stamped number
A
B
LP
LP
E
A. Access cap
B. Gasket
C. Gas pressure regulator
D
D. Spring retainer NAT position
E. Spring retainer LP position
C
To Convert Standard Surface Burners
1. Remove burner cap.
2. Remove burner base.
3. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
Refer to the following chart for the correct Natural gas orifice
spud placement.
Natural Gas Orifice Spud Chart for Standard Surface Burners
Burner LocationBurner RatingSize
Right front
Left front
Center
Right rear
Left rear
5. Place LP gas orifice spuds in plastic parts bag for future use
and keep with package containing literature.
6. Repeat steps 1-6 for the remaining burners.
7. Replace burner base, burner head and burner cap.
8. Place LP gas orifice spuds in plastic parts bag for future use
and keep with package containing literature.
9. Complete installation. See “Make Gas Connection” and
“Electronic Ignition System” sections.
Checking for proper cooktop burner flames is very important.
Natural gas flames do not have yellow tips.
IMPORTANT: You may have to adjust the “LO” setting for
each cooktop burner. See “Make Gas Connection” and
“Electronic Ignition System” section.
A
A. Orifice spud
19
Page 20
SÉCURITÉ DE LA CUISINIÈRE
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
Risque possible de décès ou de blessure grave si vous ne
DANGER
AVERTISSEMENT
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
AVERTISSEMENT : Si les renseignements dans ce manuel ne sont pas exactement
observés, un incendie ou une explosion peut survenir, causant des dommages au
produit, des blessures ou un décès.
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
– Ne pas entreposer ni utiliser de l’essence ou d’autres vapeurs ou liquides inflammables
à proximité de cet appareil ou de tout autre appareil électroménager.
– QUE FAIRE DANS LE CAS D’UNE ODEUR DE GAZ :
Ne pas tenter d’allumer un appareil.
•
Ne pas toucher à un commutateur électrique.
•
Ne pas utiliser le téléphone se trouvant sur les lieux.
•
Appeler immédiatement le fournisseur de gaz d’un téléphone voisin. Suivre
•
ses instructions.
À défaut de joindre votre fournisseur de gaz, appeler les pompiers.
•
– L’installation et l’entretien doivent être effectués par un installateur qualifié, une agence
de service ou le fournisseur de gaz.
AVERTISSEMENT : L’odorat ne permet pas toujours la détection d’une fuite de gaz.
Les distributeurs de gaz recommandent l’emploi d’un détecteur de gaz (homologation UL ou CSA).
Pour d’autre information, contacter le fournisseur de gaz local.
En cas de détection d’une fuite de gaz, exécuter les instructions “Que faut-il faire si une odeur de gaz est perceptible”.
20
Page 21
Dans l’État du Massachusetts, les instructions d’installation suivantes sont applicables :
■ Les travaux d’installation et réparation doivent être exécutés par un plombier ou tuyauteur qualifié ou licencié, ou par le
personnel qualifié d’une entreprise licenciée par l’État du Massachusetts.
■ Si une vanne à boisseau sphérique est utilisée, elle doit comporter une manette “T”.
■ Si un conduit de raccordement flexible est utilisé, sa longueur ne doit pas dépasser 3 pi.
AVERTISSEMENT
Risque de basculement
Un enfant ou une personne adulte peut faire basculer la cuisinière, ce qui peut causer
un décès.
Joindre les brides antibasculement au mur derrière la cuisinière.
Joindre les brides antibasculement sous la cuisinière.
Joindre de nouveau la bride antibasculement si la cuisinière est déplacée.
Voir les instructions d'installation pour plus de détails.
Le non-respect de ces instructions peut causer un décès ou des brûlures graves aux enfants et
aux adultes.
EXIGENCES D'INSTALLATION
Outillage et pièces
Rassembler les outils et pièces nécessaires avant d'entreprendre
l'installation. Lire et suivre les instructions fournies avec les outils
indiqués ici.
Outils nécessaires
■ Mètre ruban
■ Tournevis à lame plate
■ Tournevis Phillips
■ Niveau
■ Perceuse manuelle ou
électrique
■ Foret de ¹⁄₄" (pour mur)
■ Marteau
■ Clé ou pince
■ Clé à tuyauterie
Pièces fournies
Vérifier que toutes les pièces sont présentes.
■ Marqueur ou crayon
■ Ruban adhésif de masquage
■ Composé d'étanchéité des
raccords filetés - résistant
au propane
■ Solution non-corrosive de
détection des fuites
Pour les conversions au gaz
naturel ou au propane
■ Clé mixte de ¹⁄₂"
■ Clé mixte de 7 mm
■ Tourne-écrou de 7 mm
■ Serre-câble homologué CSA (É.-U. uniquement)
B
C
A
A. Vis du serre-câble
B. Rondelles
C. Vis de fixation
■ Connecteur de conduit homologué CSA (É.-U. uniquement)
A
B
A. Connecteur de conduit
B. Vis de fixation du connecteur
de conduit et rondelles
21
Page 22
■ Installation de la bride antibasculement
A
C
A. Brides antibasculement murales (2)
B. Brides antibasculement pour cuisinière (2)
C. Chevilles d'ancrage murales en plastique (4)
D. Vis (12)
B
D
Les brides antibasculement murales doivent être bien fixées
sur le mur arrière et les brides antibasculement pour
cuisinière doivent être bien scellées à la face interne de
l'arrière de la cuisinière.
Pièces nécessaires
Vérifier les codes locaux et consulter le fournisseur de gaz.
Vérifier l'alimentation en gaz et l'alimentation électrique
existantes. Voir les sections “Spécifications électriques” et
“Spécifications de l'alimentation en gaz”.
Exigences d'emplacement
IMPORTANT : Respecter tous les codes et règlements en
vigueur. Ne pas obstruer le flux de combustion et la ventilation.
■ C'est à l'installateur qu'incombe la responsabilité de
respecter les distances de séparation, spécifiées sur la
plaque signalétique de l'appareil. La plaque signalétique est
située à l'intérieur de la porte du four, sur le côté droit de la
garniture de la porte.
■ La cuisinière doit être installée à un endroit pratique dans la
cuisine.
■ Dans le cas d'une cuisinière encastrée, l'enceinte doit
recouvrir complètement les côtés et l'arrière de la cuisinière.
■ Afin de supprimer le risque de brûlures ou d'incendie en se
penchant au-dessus des unités de surface chauffées, le
rangement en armoire au-dessus des unités de chauffage
doit être évité. Si le rangement en armoire est envisagé, le
risque peut être réduit par l'installation d'une hotte de cuisine
ou d'un ensemble hotte/micro-ondes opérant
horizontalement sur un minimum de 5" (12,7 cm) au-delà du
bas des placards.
■ Toutes les ouvertures dans le mur ou le plancher de
l'emplacement d'installation de la cuisinière doivent être
scellées.
■ Ne pas réaliser un scellement entre la cuisinière et les
placards latéraux.
■ Respecter les dimensions indiquées pour la cavité
d'installation entre les placards. Ces dimensions tiennent
compte des valeurs minimales des dégagements de
séparation.
■ La bride antibasculement murale (brides antibasculement
murales et brides antibasculement pour la cuisinière) doit être
installée. Pour l'installation de la bride antibasculement
expédiée avec la cuisinière, voir les sections “Installation de
la bride antibasculement” et “Installation des brides
antibasculement murales”.
■ Une source d'électricité avec liaison à la terre est nécessaire.
Voir la section “Spécifications électriques”.
■ Une source de gaz adéquate doit être disponible. Voir la
section “Spécifications de l'alimentation en gaz”.
■ Contacter un installateur de revêtement de sol qualifié, qui
pourra déterminer si le revêtement de sol peut résister à une
température d'au moins 200°F (93°C).
■ Dans le cas de l'installation de la cuisinière sur de la
moquette, placer sous la cuisinière une plaque d'appui isolée,
ou une plaque de contreplaqué de ¼" (0,64 cm).
IMPORTANT : Pour éviter que vos placards ne subissent tout
dommage, consulter le constructeur ou le fabricant du placard
pour déterminer si les matériaux utilisés ne subiront pas un
changement de couleur, une déstratification ou d'autres
dommages. Ce four a été conçu conformément aux exigences
UL et aux normes de CSA International; il respecte la
température maximale autorisée pour les placards en bois :
194°F (90°C).
Résidence mobile - Spécifications additionnelles à
respecter lors de l'installation
L'installation de cette cuisinière doit être conforme aux
dispositions de la norme Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 (anciennement Federal
Standard for Mobile Home Construction and Safety, Title 24,
HUD Part 280). Lorsque cette norme n'est pas applicable,
l'installation doit satisfaire aux critères de la norme Standard for
Manufactured Home Installations, ANSI A225.1/NFPA 501A ou
les dispositions des codes locaux.
Au Canada, l'installation de cette cuisinière doit satisfaire aux
stipulations de la version la plus récente de la norme CAN/CSAA240, ou des codes locaux en vigueur.
Autres critères à respecter pour une installation en résidence
mobile :
■ Dans le cas de l'installation de cette cuisinière dans une
résidence mobile, la cuisinière doit être fixée au plancher
durant tout déplacement du véhicule. Toute méthode de
fixation de la cuisinière est adéquate dans la mesure où elle
satisfait aux critères des normes mentionnées ci-dessus.
■ Pour une installation en résidence mobile, un câble ou cordon
d'alimentation à quatre fils doit être utilisé. Le câblage de
l'appareil devra être revu. Voir la section “Spécifications de
l'installation électrique”.
22
Page 23
Dimensions de l'appareil
B
A. 35¹⁄₄" (89,5 cm)
B. Plaque des numéros de
modèle et de série
(située à l'intérieur de la porte
du four, sur le côté droit de la
garniture de la porte)
D
E
A
H
F
G
L
I
J
C
C
K
C. Pieds réglables de 5³⁄₄" min. à 9¹⁄₁₆"
max. (de 14,6 cm min. à 23,0 cm
max.)
D. 1" (2,5 cm)
E. 23⁵⁄₈" (60,0 cm)
F. 2 9 ¹⁄₂" (75,0 cm)
G. 1⁵⁄₈" (4,0 cm)
H. Panneau avant
I. Porte du four
J. De 35¹⁄₄" à 37⁷⁄₈" max. (de 89,5 cm à
96,2 cm max.)
K. 40⁹⁄₁₆" +/- ¹⁄₈" (103,0 cm +/- 2,5 mm)
L. De 5³⁄₄" min. à 9¹⁄₁₆" max.
(de 14,6 cm min. à 23 cm max.)
Dimensions du placard
Les dimensions de l'espace d'installation entre les placards sont valides pour l'installation entre des placards de 24" (61,0 cm) et plan
de travail de profondeur de 25" (64,0 cm) et hauteur de 36" (91,4 cm).
IMPORTANT : En cas d'installation d'une hotte ou d'un ensemble hotte/micro-ondes au-dessus de la cuisinière, suivre les instructions
fournies avec la hotte ou l'ensemble hotte/micro-ondes concernant les dimensions de dégagement à respecter au-dessus de la surface
de la table de cuisson.
A. 18" (45,7 cm) entre le placard supérieur et le plan de travail
B. Profondeur des placards supérieurs : 13" (33,0 cm)
C. Largeur minimale de l'ouverture : 35¹⁄₂" (90,1 cm)
D. Pour la distance libre minimale vers la partie supérieure de la table
de cuisson, voir REMARQUE.
E. Largeur minimale de l'ouverture : 35¹⁄₄" (89,5 cm)
F. Installation de la canalisation de gaz rigide recommandée dans cette
zone ombrée.
G. Zone de 8" (20,3 cm) disponible pour l’installation du gaz et de
l’électricité.
H. Installation de la prise de courant ou du boîtier de raccordement
électrique dans cette zone ombrée.
M
I. 7" (17,8 cm)
J. 1¹⁄₂" (3,8 cm)
K. 4¹⁄₂" (11,4 cm)
L. Égagement de 5" (12,7 cm) min. entre les deux côtés de la cuisinière
et les parois latérales ou d'autres matériaux combustibles.
M. La porte ou charnière du placard ne doit pas dépasser à l'intérieur
de l'ouverture.
REMARQUE : Distance de séparation de 24" (61,0 cm) ou plus
lorsque le fond d'un placard de bois ou de métal est protégé par
une planche ignifugée d'au moins ¼" (0,64 cm) recouverte d'une
feuille métallique d'épaisseur égale ou supérieure à : acier calibre
28 MSG, acier inoxydable 0,015" (0,4 mm), aluminium
0,024" (0,6 mm), ou cuivre 0,020" (0,5 mm).
Distance de séparation de 30" (76,2 cm) ou plus entre le dessus
de la table de cuisson et le fond d'un placard de bois ou de métal
non protégé.
23
Page 24
Spécifications de l’installation électrique
Spécifications de l’alimentation en gaz
AVERTISSEMENT
Risque de choc électrique
Relier la cuisinière à la terre.
Le non-respect de cette instruction peut causer
un décès, un incendie ou un choc électrique.
Si le code en vigueur le permet et qu’un conducteur distinct de
liaison à la terre est utilisé, on recommande qu’un électricien
qualifié vérifie que la liaison à la terre et la taille du conducteur de
liaison à la terre sont conformes aux prescriptions du code local.
Vérifier que le raccordement à la source d’électricité et le calibre
des conducteurs sont adéquats et conformes aux prescriptions
de la plus récente édition de la norme CSA C22.1, partie 1 - Code
canadien de l’électricité, et de tout code ou règlement local en
vigueur.
On peut obtenir un exemplaire de la norme ci-dessus auprès de :
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.
■ En cas de doute quant à la qualité de la liaison à la terre de la
cuisinière, consulter un électricien qualifié.
■ Lorsqu’une source d’électricité monophase de 120/240 volts,
60 Hz/4 conducteurs (CA uniquement) est disponible, le
circuit doit comporter un dispositif de protection 50 A
maximum (ou 40 A si la source d’électricité spécifiée sur la
plaque signalétique est de 120/208 volts), fusionné aux deux
extrémités de la ligne.
■ On recommande l’emploi de fusibles temporisés ou
disjoncteurs.
■ Cette cuisinière est dotée d’un dispositif de branchement
(homologation CSA International) destiné à être branché sur
une prise de courant murale standard 14-50R. Veiller à ce
que la prise de courant murale soit placée à portée de la
position de service finale de la cuisinière.
■ Ne pas utiliser de câble de rallonge.
AVERTISSEMENT
Risque d'explosion
Utiliser une canalisation neuve d'arrivée de gaz
approuvée par CSA International.
Installer un robinet d'arrêt.
Bien serrer chaque organe de connexion de la
canalisation de gaz.
En cas de connexion au gaz propane, demander à une
personne qualifiée de s’assurer que la pression de gaz
ne dépasse pas 33 cm (13 po) de la colonne d’eau.
Par personne qualifiée, on comprend :
le personnel autorisé de chauffage,
le personnel autorisé d’une compagnie de gaz, et
le personnel d’entretien autorisé.
Le non-respect de ces instructions peut causer
un décès, un explosion ou un incendie.
Observer toutes les prescriptions des codes et règlements en
vigueur.
IMPORTANT : L'installation doit satisfaire aux critères de tous les
codes et règlements locaux. En l'absence de code local,
l'installation doit satisfaire aux prescriptions de la plus récente
édition du code national en vigueur : National Fuel Gas Code
ANSI Z223.1 (American National Standard), ou CAN/CGA B149.
IMPORTANT : La procédure de détection d'éventuelles fuites de
gaz de la surface de cuisson de la cuisinière doit être exécutée
conformément aux instructions du fabricant.
Type de gaz
Gaz naturel :
La conception de cette cuisinière a été homologuée par CSA
International pour l'alimentation au gaz naturel, ou pour
l'alimentation au propane après conversion adéquate.
■ Cette cuisinière a été configurée à l'usine pour l'alimentation
au gaz naturel. Voir la section “Conversions pour changement
de gaz”. La plaque signalétique des numéros de modèle et
de série située à l'intérieur de la porte du four, sur le côté droit
de la garniture de la porte contient des informations au sujet
des types de gaz pouvant être utilisés. Si le type de gaz
disponible n'est pas mentionné sur la plaque signalétique,
consulter le fournisseur de gaz local.
Conversion pour l'alimentation au propane :
L'opération de conversion doit être exécutée par un technicien
qualifié.
Consulter le fournisseur de gaz avant toute conversion de
l'appareil pour l'utilisation d'un type de gaz qui n'est pas
mentionné sur la plaque signalétique. Voir la section
“Conversions pour changement de gaz”.
24
Page 25
Canalisation de gaz
Détendeur de gaz
■ Installer une canalisation de gaz rigide de ¾" (1,9 cm) jusqu'à
l'emplacement d'installation de la cuisinière. L'emploi d'une
canalisation de plus petit diamètre sur une plus grande
longueur peut susciter une déficience du débit
d'alimentation. On doit utiliser un composé d’étanchéité des
tuyauteries résistant à l’action du gaz propane. Ne pas utiliser
de ruban TEFLON
®†
. Pour l'alimentation au propane, le
diamètre des canalisations et tubes doit être de ½" (1,3 cm)
ou plus. En général, le fournisseur de gaz propane détermine
les matériaux à utiliser et le diamètre approprié.
Raccord métallique flexible :
■ Si le code local le permet, on peut utiliser pour raccorder
la cuisinière à la canalisation de gaz un raccord
métallique flexible neuf (homologation CSA) de
4 - 5 pi (122 - 152,4 cm) de longueur, de diamètre interne
de ¹⁄₂" (1,3 cm) ou ¾" (1,9 cm).
■ Un raccord avec filetage mâle de ½" (1,3 cm) est
nécessaire pour la connexion sur le raccord à filetage
femelle à l'entrée du détendeur de l'appareil.
■ Veiller à ne pas déformer/écraser/endommager le tube
métallique flexible lors d'un déplacement de la cuisinière.
Raccordement par un ensemble rigide :
On doit utiliser une combinaison de raccords pour réaliser un
raccordement rigide entre la cuisinière et la canalisation de
gaz. Le tuyau rigide doit se trouver au même niveau que le
raccord de connexion de la cuisinière. On doit veiller à ne
soumettre les sections de canalisation d'alimentation à aucun
effort de traction ou flexion, pour que la cuisinière soit
d'aplomb et correctement alignée.
Le détendeur fourni avec cette cuisinière doit être utilisé. Pour un
fonctionnement correct, la pression d'alimentation du détendeur
doit être comme suit :
Pression minimum : 11" (27,9 cm) (colonne d'eau)
Pression maximum : 13" (35,6 cm) (colonne d'eau)
En cas d'incertitude quant à la pression d'alimentation à établir,
contacter le fournisseur de gaz local.
Débit thermique des brûleurs - Altitude
Les débits thermiques indiqués sur la plaque signalétique
correspondent à une altitude d'utilisation inférieure à
2000 pi (609,6 m).
Lorsque l'appareil est utilisé à une altitude supérieure à
2000 pi (609,6 m), on doit réduire le débit thermique indiqué de
4 % pour chaque tranche de 1000 pi (304,8 m) au-dessus du
niveau de la mer.
Tests de pressurisation de la canalisation de gaz
Pressurisation à une pression supérieure à ½ lb/po²
(13" - colonne d'eau)
Lors de tout test de pressurisation de ce système à une pression
supérieure à ½ lb/po² (3,5 kPa), on doit déconnecter l'appareil et
son robinet d'arrêt individuel de la canalisation de gaz.
Pressurisation à une pression relative de ½ lb/po²
(13" - colonne d'eau) ou moins
Lors de tout test de pressurisation de la canalisation de gaz à une
pression égale ou inférieure à ½ lb/po² (3,5 kPa), on doit isoler
l'appareil de la canalisation de gaz par fermeture de son robinet
d'arrêt manuel individuel.
■ Robinet d'arrêt manuel nécessaire :
La canalisation d'alimentation doit comporter un robinet
d'arrêt manuel. Le robinet d'arrêt manuel doit être séparé de
la cuisinière, mais doit se trouver dans la même pièce en un
endroit où il sera facilement accessible pour les manoeuvres
d'ouverture/fermeture. Ne pas entraver l'accès au robinet
d'arrêt manuel. Le robinet d'arrêt manuel est prévu pour
ouvrir ou fermer l’alimentation en gaz de la cuisinière.
B
A
C
A. Canalisation de gaz
B. Robinet d'arrêt manuel - position d'ouverture
C. Vers la cuisinière
†®TEFLON est une marque déposée de E.I. Du Pont De Nemours et Compagnie.
25
Page 26
INSTRUCTIONS D'INSTALLATION
Déballage de la cuisinière
AVERTISSEMENT
Risque du poids excessif
Utiliser deux ou plus de personnes pour déplacer et
installer la cuisinière.
Le non-respect de cette instruction peut causer
une blessure au dos ou d'autre blessure.
1. Ôter les matériaux d'emballage, le ruban adhésif et le film
protecteur de la cuisinière. Retirer les grilles de four et le
sachet de pièces de l'intérieur du four.
2. Il y a au sommet de l'emballage une plaque de polystyrène,
placer celle-ci sur le sol derrière la cuisinière pour la
protection du plancher et de la cuisinière lorsque la cuisinière
sera en appui sur la face arrière. À l’aide d’au moins une autre
personne, saisir fermement la cuisinière pour la faire basculer
avec précaution et placer la face arrière en appui sur la
plaque de polystyrène.
Installation des brides
antibasculement pour cuisinière
1. Utiliser les 8 vis fournies pour fixer solidement les brides
antibasculement pour cuisinière dans chaque angle arrière de
la cuisinière.
Réglage de la hauteur des pieds
1. Si un réglage de la hauteur de la cuisinière est nécessaire,
ajuster manuellement les manchons de pieds de nivellement
pour déserrer les 4 pieds de réglage de l'aplomb.
Les pieds de réglage de l'aplomb peuvent être desserrés
pour gagner jusqu'à un maximum de 5³⁄₄" (14,6 cm) de
hauteur.
Ceci doit être effectué alors que la cuisinière repose sur sa
partie postérieure ou qu'elle est supportée par 2 pieds après
avoir été replacée en position verticale.
A
A. Manchons de pieds de nivellement
REMARQUE : Pour placer à nouveau la cuisinière en position
verticale, placer un carton ou un panneau de fibres dur
devant la cuisinière. Avec l’aide d’au moins une autre
personne, relever la cuisinière et la placer sur le carton ou le
panneau de fibres dur.
A
B
A. Brides antibasculement pour cuisinière (2)
B. 8 vis (4 par brides)
Installation des pieds de réglage de
l'aplomb
1. Retirer les 4 pieds de réglage de l'aplomb du sachet de
pièces.
2. Pour fixer les pieds de réglage, visser dans le sens des
aiguilles d’une montre un pied dans le trou fileté situé dans
chaque angle sous la cuisinière.
AVERTISSEMENT
Risque de basculement
Un enfant ou une personne adulte peut faire basculer
la cuisinière, ce qui peut causer un décès.
Joindre les brides antibasculement au mur derrière
la cuisinière.
Joindre les brides antibasculement sous la cuisinière.
Joindre de nouveau la bride antibasculement si
la cuisinière est déplacée.
Voir les instructions d'installation pour plus de détails.
Le non-respect de ces instructions peut causer
un décès ou des brûlures graves aux enfants et
aux adultes.
2. Lorsque la cuisinière est à la hauteur souhaitée, vérifier qu'il y
a un espace suffisant entre la cuisinière et le mur pour loger
les brides antibasculement. Avant de faire glisser la cuisinière
à son emplacement final, installer les brides antibasculement.
26
Page 27
Réglage de l'aplomb de la cuisinière
1. Placer une grille dans le four.
2. Placer un niveau sur la grille et contrôler l'aplomb, d'abord
transversalement, puis dans le sens avant/arrière.
3. Si la cuisinière n'est pas parfaitement d'aplomb, tirer la
cuisinière vers l'avant.
4. Ajuster manuellement les pieds de nivellement vers le haut ou
vers le bas. Tourner les manchons des pieds de nivellement
pour mettre la cuisinière d'aplomb et pour soulever ou
abaisser la cuisinière à la hauteur du plan de travail désirée.
REMARQUE : La cuisinière doit être d'aplomb pour pouvoir
obtenir des résultats de cuisson satisfaisants.
5. Poursuivre l'installation de la cuisinière en utilisant les
instructions d'installation suivantes.
Installation des brides
antibasculement murales
Avant de déplacer la cuisinière, la faire glisser sur sa base
d'expédition, un carton ou un panneau de fibres dur.
1. Utiliser un mètre ruban pour les mesures et tracer l'axe
vertical sur le mur arrière de la cavité d'installation. Utiliser les
dimensions indiquées ci-dessous pour déterminer la position
des brides antibasculement murales sur le mur arrière de la
cavité d'installation.
2. Mesurer la distance entre le bas des brides antibasculement
pour cuisinière et le plancher; ajouter ⁵⁄₈" (16 mm) à cette
valeur; marquer la position correspondante sur le mur arrière
de la cavité d'installation.
3. Mesurer une distance de 13⁵⁄₈" (34,6 cm) à droite et à gauche
de l'axe vertical (A) tracé à l'étape 1; marquer les points
d'intersection ; ceci déterminera l'emplacement du sommet
de chaque bride.
4. Fixer solidement chaque bride antibasculement murale sur le
mur arrière de la cavité d'installation; utiliser les chevilles
d'ancrage murales et les vis fournies.
A
B
C
A
B
C
A. Axe central
B. 27½" (70,0 cm)
C. Déterminer la distance entre le bas des brides
antibasculement pour cuisinière et le plancher
et ajouter ⁵⁄₈" (16 mm).
A. Brides antibasculement murales
B. Chevilles d'ancrage murales
C. Vis de fixation
5. Approcher la cuisinière du mur suffisamment pour pouvoir
effectuer les raccordements électriques finaux. Retirer la
base d'expédition, le carton ou le panneau de fibres dur de
sous la cuisinière.
27
Page 28
Raccordement au gaz
J
Le détendeur est fourni avec l'ensemble Raccordement au circuit
de distribution de gaz. Vérifier que toutes les pièces sont
présentes.
A
B
Raccordement typique à une canalisation rigide
On doit utiliser une combinaison de raccords pour raccorder la
cuisinière à la canalisation de gaz existante. La configuration de
la connexion sera variable, selon les caractéristiques de la
canalisation d'alimentation (type, taille et position).
1. Sur chaque connexion filetée, appliquer un composé
d'étanchéité résistant au propane.
2. Utiliser une clé pour serrer tous les raccords entre la
cuisinière et la canalisation de gaz.
I
H
G
C
A
D
E
A. Joint
B. Canalisation
C. Plaque
D. Raccord d'adaptation
E. Détendeur
1. Effectuer le raccordement entre le détendeur et la
canalisation; utiliser le raccord d'adaptation.
C
B
A
D
A. Détendeur
B. Raccord d'adaptation
C. Plaque
D.Canalisation
2. Fixer solidement la canalisation et la plaque sous la
cuisinière; utiliser les vis fournies.
A
C
A. Plaque
B. Détendeur
C. Vis
B
A
C
A. Tuyau de gaz de ½" ou ¾"
B. Robinet d'arrêt manuel
C. Mamelon
D. Raccord
E. Coude à 90°
F
D
F. Tuyau en fer noir
G. Raccord
H. Mamelon
I. Coude à 90° (avec
filetage mâle NPT ½")
J. Détendeur
E
Raccordement typique par raccord flexible
1. Appliquer un composé d'étanchéité des filetages résistant au
propane sur l'extrémité filetée la plus petite des adaptateurs
de raccord flexible (voir C et G dans l'illustration ci-dessous).
2. Fixer un raccord d'adaptation sur le détendeur et l'autre
raccord d'adaptation sur le robinet d'arrêt de la canalisation
de gaz. Serrer les deux raccords d'adaptation.
3. Utiliser une clé mixte de ¹⁵⁄₁₆" et une pince multiprise pour
fixer le raccord flexible sur les raccords d'adaptation. Veiller à
ne pas déformer/écraser le raccord.
H
E
B
D
F
G
B
A. Tuyau de gaz de ½" ou ¾"
B. Robinet d'arrêt manuel
C. Appliquer un composé
d'étanchéité des filetages
D. Raccord d'adaptation
A
C
E. Raccord flexible
F. Raccord d'adaptation (avec
filetage mâle NPT ½")
G. Appliquer un composé
d'étanchéité des filetages
H. Détendeur
Compléter le raccordement
1. Ouvrir le robinet d'arrêt manuel sur la canalisation de gaz. Le
robinet est ouvert lorsque la manette est parallèle à la
canalisation de gaz.
A
B
A. Robinet fermé
B. Robinet ouvert
28
Page 29
2. Vérifier tous les raccordements en les badigeonnant d'une
solution de détection des fuites non corrosive approuvée.
L'apparition de bulles indique une fuite. Réparer toute fuite
éventuelle.
3. Ôter les chapeaux et grilles de brûleur de la table de cuisson
du sachet de pièces. Aligner les encoches des chapeaux de
brûleur avec les broches dans la base de chaque brûleur. Un
chapeau de brûleur correctement placé doit être horizontal.
Si le chapeau de brûleur n'est pas correctement placé, le
brûleur ne peut s'allumer. Placer les grilles de brûleur audessus des brûleurs et des chapeaux.
A
Si le brûleur ne s'allume pas correctement :
■ Ramener le bouton de commande du brûleur de surface à la
position “OFF”.
■ Vérifier que le cordon d'alimentation est branché et
■ Vérifier que le chapeau de brûleur est correctement placé sur
la base du brûleur.
S'assurer à nouveau du bon fonctionnement des brûleurs. Si à ce
stade un brûleur ne s'allume pas, contacter le revendeur ou un
dépanneur agréé.
Réglage de la taille des flammes
Régler la taille des flammes sur les brûleurs de surface.
Pour le réglage au débit thermique minimum, on doit observer
des flammes stables bleues d’environ ¼" (0,64 cm) de hauteur.
B
C
D
A. Grille de brûleur
B. Chapeau de brûleur
C. Tête de brûleur
D. Base du brûleur
B
C
D
4. Brancher la cuisinière ou reconnecter la source de courant
électrique. Pour plus de renseignements, consulter les
instructions pour l'utilisateur dans le Guide d'utilisation et
d'entretien.
5. Déplacer la cuisinière à son emplacement final. Vérifier le bon
engagement des brides antibasculement.
Système d'allumage électronique
Allumer un brûleur de surface
Enfoncer et tourner chaque bouton de commande de la table de
cuisson à la position “LITE” (allumage). Une étincelle allumera
automatiquement le brûleur.
Contrôle du fonctionnement des brûleurs de surface
Enfoncer et tourner les boutons de commande des brûleurs de
surface à la position “LITE”.
Le gaz doit s'enflammer sur le brûleur de surface en moins de
4 secondes. Lors de l'allumage initial du brûleur de surface, le
délai d'allumage peut être supérieur à 4 secondes du fait de la
présence d'air dans la canalisation de gaz.
Vérifier que la flamme est bleue à la position “HI”. Elle doit être
propre et douce. On ne doit pas observer de pointe jaune, ni
d'effet de soufflage ou de séparation entre les flammes et le
brûleur. Il est normal d'observer parfois des éclairs oranges; ceci
est dû à différents éléments dans l'air ou le gaz.
Après avoir vérifié le bon fonctionnement du brûleur, tourner les
boutons de commande à “OFF” (arrêt).
A
B
A. Débit thermique minimum
B. Débit thermique maximum
S'il est nécessaire de régler la taille des flammes pour le
débit thermique minimum :
La vis de réglage au centre de la tige de commande du robinet
permet de régler la taille des flammes. La tige de commande est
située directement en dessous du bouton de commande.
A
A. Vis de réglage
1. Ôter le bouton de commande.
2. Immobiliser la tige de commande avec une pince. Utiliser un
petit tournevis à lame plate pour faire tourner la vis située au
centre de la tige de commande; ajuster les flammes à la taille
désirée.
3. Réinstaller le bouton de commande.
4. Tester le fonctionnement du brûleur : faire passer le bouton
de commande de la position “LO” (basse) à la position “HI”
(élevée) et observer les flammes pour chaque réglage.
Achever l'installation
1. Vérifier que toutes les pièces sont maintenant installées. S'il
reste une pièce, passer en revue les différentes étapes pour
découvrir laquelle aurait été oubliée.
2. Vérifier la présence de tous les outils.
3. Jeter ou recycler tous les matériaux d’emballage.
4. Vérifier que la cuisinière est d'aplomb. Voir “Réglage de
l'aplomb de la cuisinière”.
29
Page 30
5. Utiliser une solution d'eau tiède et de nettoyant ménager
C
doux pour éliminer tout résidu de cire laissé par les matériaux
de protection de l'emballage. Sécher parfaitement avec un
linge doux. Pour plus d'informations, consulter la section
“Entretien de la cuisinière” dans le Guide d'utilisation et
d'entretien.
6. Lire la section “Utilisation de la cuisinière” dans le Guide
d'utilisation et d'entretien.
7. Mettre en marche les brûleurs de surface et le four. Pour des
instructions spécifiques concernant l'utilisation de la
cuisinière, consulter le Guide d'utilisation et d'entretien.
Si la cuisinière ne fonctionne pas, contrôler ce qui suit :
■ Fusible grillé ou desserré? Disjoncteur ouvert?
■ Robinets de gaz à la position “open” (ouverture)?
■ Si le robinet d'arrêt d'alimentation en gaz est ouvert, appuyer
sur le bouton OFF (arrêt) sur le tableau de commande du four
et contacter un électricien qualifié.
■ Prise de courant correctement alimentée?
■ Consulter la section “Dépannage” dans le Guide d'utilisation
et d'entretien.
Après 5 minutes de fonctionnement de la cuisinière, vérifier la
chaleur. Si la cuisinière est froide, l'éteindre et contacter un
technicien qualifié.
CONVERSIONS POUR
Conversion pour l'alimentation au propane
AVERTISSEMENT
Risque de basculement
Un enfant ou une personne adulte peut faire basculer
la cuisinière, ce qui peut causer un décès.
Joindre les brides antibasculement au mur derrière
la cuisinière.
Joindre les brides antibasculement sous la cuisinière.
Joindre de nouveau la bride antibasculement si
la cuisinière est déplacée.
Voir les instructions d'installation pour plus de détails.
Le non-respect de ces instructions peut causer
un décès ou des brûlures graves aux enfants et
aux adultes.
CHANGEMENT DE GAZ
Les conversions pour changement de gaz naturel à propane ou
de propane à gaz naturel doivent être effectuées par un
installateur qualifié.
AVERTISSEMENT
Risque d'explosion
Utiliser une canalisation neuve d'arrivée de gaz
approuvée par CSA International.
Installer un robinet d'arrêt.
Bien serrer chaque organe de connexion de la
canalisation de gaz.
En cas de connexion au gaz propane, demander à une
personne qualifiée de s’assurer que la pression de gaz
ne dépasse pas 33 cm (13 po) de la colonne d’eau.
Par personne qualifiée, on comprend :
le personnel autorisé de chauffage,
le personnel autorisé d’une compagnie de gaz, et
le personnel d’entretien autorisé.
Le non-respect de ces instructions peut causer
un décès, un explosion ou un incendie.
Conversion du détendeur
1. Tourner le robinet d'arrêt manuel à la position “fermée”.
2. Débrancher la cuisinière ou déconnecter la source de courant
électrique.
B
A
A. Vers la cuisinière
B. Robinet d'arrêt manuel (position de fermeture)
C. Canalisation de gaz
3. Ôter le couvercle d'accès du détendeur.
A
A. Détendeur
IMPORTANT : Ne pas enlever le détendeur.
Détendeur
4. Utiliser une clé pour enlever le chapeau de l'ouverture
d'accès; faire tourner le chapeau dans le sens antihoraire.
5. Ôter le ressort de retenue qui se trouve sous le chapeau -
pousser contre le côté plat du ressort de retenue. Examiner le
ressort de retenue pour identifier la position “NAT” ou “LP”.
6. Orienter correctement le ressort de retenue pour que la
mention “LP” soit au fond.
7. Réinstaller le ressort de retenue dans le chapeau.
30
Page 31
8. Réinstaller le chapeau sur le détendeur.
A
A
LP
E
A. Chapeau de l'ouverture
d'accès
B. Joint d'étanchéité
LP
D
C. Détendeur
D. Ressort de retenue - position LP
E. Ressort de retenue - position NAT
B
C
Conversion des brûleurs standard de la table de cuisson
5. Placer les gicleurs pour gaz naturel dans le sachet de pièces
en plastique et avec les documents fournis avec l'appareil,
pour pouvoir les réutiliser ultérieurement.
6. Répéter les étapes 1 à 6 pour les autres brûleurs.
7. Réinstaller le brûleur, la tête et le chapeau du brûleur.
8. Placer les gicleurs pour gaz naturel dans le sachet de pièces
en plastique et avec les documents fournis avec l'appareil,
pour pouvoir les réutiliser ultérieurement.
9. Achever l'installation. Voir les sections “Raccordement au
gaz” et “Système d'allumage électronique”.
Il est très important de vérifier l'établissement de flammes
correctes sur les brûleurs de la table de cuisson. Il doit y avoir
un petit cône interne bleu distinct de ¼" à ½" de long. La
partie externe des flammes n'est pas aussi distincte que le
cône interne. Les flammes d'un brûleur alimenté au propane
comportent une pointe légèrement jaune.
IMPORTANT : Il peut être nécessaire de modifier le réglage
des flammes à la position du débit thermique minimum pour
chaque brûleur de la table de cuisson. Voir les sections
“Raccordement au gaz” et “Système d'allumage
électronique”.
1. Ôter le chapeau de brûleur.
2. Ôter la base du brûleur.
3. Appliquer du ruban adhésif de masquage à l'extrémité d'un
tourne-écrou de 7 mm pour retenir le gicleur du brûleur dans
le tourne-écrou durant l'extraction. Placer le tourne-écrou sur
le gicleur; faire tourner dans le sens antihoraire et soulever
pour enlever le gicleur. Conserver à part le gicleur du brûleur.
A
A. Gicleur
4. Chaque gicleur est marqué d'un code d'identification gravé
sur le côté.
XXX
Conversion pour l'alimentation au gaz
naturel
AVERTISSEMENT
Risque de basculement
Un enfant ou une personne adulte peut faire basculer
la cuisinière, ce qui peut causer un décès.
Joindre les brides antibasculement au mur derrière
la cuisinière.
Joindre les brides antibasculement sous la cuisinière.
Joindre de nouveau la bride antibasculement si
la cuisinière est déplacée.
Voir les instructions d'installation pour plus de détails.
Le non-respect de ces instructions peut causer
un décès ou des brûlures graves aux enfants et
aux adultes.
A. Chiffre gravé
Le tableau qui suit permet de sélectionner le gicleur pour
propane approprié à chaque brûleur.
Gicleurs pour propane, pour brûleurs standard de la table de
cuisson
Position du brûleurPuissance thermique Taille
Avant droit
Avant gauche
Centre
Arrière droit
Arrière gauche
1. Tourner le robinet d'arrêt manuel à la position “fermée”.
0,53 mm
0,73 mm
1 mm
0,73 mm
0,93 mm
31
Page 32
2. Débrancher la cuisinière ou déconnecter la source de courant
C
A
électrique.
B
A
A. Vers la cuisinière
B. Robinet d'arrêt manuel (position de fermeture)
C. Canalisation de gaz
3. Ôter le couvercle d'accès du détendeur.
A
A. Détendeur
IMPORTANT : Ne pas enlever le détendeur.
Détendeur
4. Utiliser une clé pour enlever le chapeau de l'ouverture
d'accès; faire tourner le chapeau dans le sens antihoraire.
5. Ôter le ressort de retenue qui se trouve sous le chapeau -
pousser contre le côté plat du ressort de retenue. Examiner le
ressort de retenue pour identifier la position “LP” ou “NAT”.
6. Orienter correctement le ressort de retenue pour que la
mention “NAT”soit au fond.
7. Réinstaller le ressort de retenue dans le chapeau.
8. Réinstaller le chapeau sur le détendeur.
3. Appliquer du ruban adhésif de masquage à l'extrémité d'un
tourne-écrou de 7 mm pour retenir le gicleur du brûleur dans
le tourne-écrou durant l'extraction. Placer le tourne-écrou sur
le gicleur; faire tourner dans le sens antihoraire et soulever
pour enlever le gicleur. Mettre celui-ci de côté.
A
A. Gicleur
4. Chaque gicleur est marqué d'un code d'identification gravé
sur le côté. Remplacer le gicleur pour propane par le gicleur
correct pour gaz naturel.
XXX
A. Chiffre gravé
Le tableau qui suit permet de sélectionner le gicleur pour gaz
naturel approprié à chaque brûleur.
Gicleurs pour gaz naturel, pour brûleurs standard de la table
de cuisson
Position du brûleur Puissance
Taille
thermique
A
B
LP
LP
E
A. Chapeau de l'ouverture
d'accès
B. Joint d'étanchéité
D
C. Détendeur
D. Ressort de retenue - position NAT
E. Ressort de retenue - position LP
C
Conversion des brûleurs standard de la table de cuisson
1. Ôter le chapeau du brûleur.
2. Ôter la base du brûleur.
Avant droit
Avant gauche
Centre
Arrière droit
Arrière gauche
5. Placer les gicleurs pour propane dans le sachet de pièces en
plastique et avec les documents fournis avec l'appareil, pour
pouvoir les réutiliser ultérieurement.
6. Répéter les étapes 1 à 6 pour les autres brûleurs.
7. Réinstaller la base, la tête et le chapeau du brûleur.
8. Placer les gicleurs pour propane dans le sachet de pièces en
plastique et avec les documents fournis avec l'appareil, pour
pouvoir les réutiliser ultérieurement.
9. Achever l'installation. Voir les sections “Raccordement au
gaz” et “Système d'allumage électronique”.
Il est très important de vérifier l'établissement de flammes
correctes sur les brûleurs de la table de cuisson. Les flammes
d'un brûleur alimenté au gaz naturel ne comportent pas de
pointe jaune.
IMPORTANT : Il peut être nécessaire de modifier le réglage
des flammes à la position du débit thermique minimum pour
chaque brûleur de la table de cuisson. Voir les sections
“Raccordement au gaz” et “Système d'allumage
électronique”.