54" and 60" Linear Electric Fireplaces
P/N 900264-00 Rev. A 03/2017
MODELS
INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference
INSTALLATEUR : Laissez cette notice avec l’appareil.
CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
A French manual is available upon request. Order P/N 900278-00
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 900278-00.
IMPORTANT! TO ASSURE PROPER ALIGNMENT, INSTALL THIS
FIREPLACE IN A SQUARE AND PLUMB CONDITION, USING SHIMS
AS NECESSARY AT SIDES.
Arcturus54
Arcturus60
This manual will enable you to obtain a safe, effi cient and dependable installation and operation of your electric fi replace. Please read
and understand these instructions before beginning your installation.
Do not alter or modify this fi replace or its components under any
circumstances. Any modifi cation or alteration of the fi replace system,
including but not limited to the fi replace and accessories, may void
the warranty, listings and approvals of this system and could result
in an unsafe and potentially dangerous installation.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
EXPOSED SURFACES OF THE ELECTRONIC FIREPLACE ADJACENT
TO HEATERS AND BLOWERS MAY BECOME HOT. CARE SHOULD
BE TAKEN TO AVOID CONTACT WITH BLOWER HEAT DISCHARGE
OUTLETS SUCH AS THE ONE ON THE TOP OF THIS FIREPLACE.
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
Artesia54
Artesia60
FOR YOUR SAFETY
ERC4054
ERC4060
MPE-54L
MPE-60L
IHP electric fi replaces are designed for use as a decorative appliance and/or as a supplemental heater. They are not intended
for continuous use as a primary heat source.
C
®
US
Report # 1906849
P900264-00
BEFORE STARTING YOUR FIREPLACE INSTALLATION, READ THIS
INSTALLATION AND OPERATION MANUAL VERY CAREFULLY TO
ENSURE YOU UNDERSTAND IT COMPLETELY AND IN ENTIRETY.
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A
POSSIBLE ELECTRIC SHOCK, FIRE HAZARD AND/OR INJURY OR
PROPERTY DAMAGE AND WILL VOID THE WARRANTY.
EXTREME CAUTION IS NECESSARY WHEN ANY HEATER IS USED
BY OR NEAR CHILDREN OR INVALIDS AND WHENEVER THE
HEATER IS LEFT OPERATING AND UNATTENDED.
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
IMPORTANT SAFETY AND
WARNING INFORMATION
READ THIS MANUAL IN ITS ENTIRETY
AND UNDERSTAND THESE RULES
TO FOLLOW FOR SAFETY.
WARNING
If the information in this manual
is not followed exactly, an electrical shock or fi re may result
causing property damage, personal injury or loss of life.
IMPORTANT
Before starting your fi replace
installation, read this installation and operation manual
very carefully to ensure you
understand it completely and in
entirety. Failure to follow these
instructions may result in a possible electric shock, fi re hazard
and/or injury or property damage
and will void the warranty.
CAUTION
Extreme caution is necessary
when any heater is used by or
near children or invalids and
whenever the heater is left operating and unattended.
WARNING
To prevent contact with sagging or loose insulation, the
appliance must not be installed
against vapor barriers or exposed
insulation. Localized overheating could occur and a fi re could
result. Insulation and a vapor
barrier should be placed a
minimum of 2 inches from the
appliance.
TO PREVENT A POSSIBLE FIRE, DO NOT
BLOCK AIR INTAKES OR EXHAUSTS IN
ANY WAY. DO NOT USE NEAR SOFT
SURFACES, LIKE A PILLOW, WHERE
OPENINGS MAY BECOME BLOCKED.
THIS APPLIANCE MAY BECOME HOT
WHEN IN USE. TO AVOID BURNS, DO NOT
LET BARE SKIN TOUCH HOT SURFACES.
KEEP COMBUSTIBLE MATERIALS, SUCH
AS FURNITURE, PILLOWS, BEDDING,
PAPERS, CLOTHES AND CURTAINS AT
LEAST 3 FEET (1 METER) FROM THE
FRONT OF THIS APPLIANCE.
DO NOT OPERATE ANY HEATER WITH
DAMAGED WIRING OR CONNECTORS,
OR AFTER THE APPLIANCE MALFUNCTIONS, OR IF IT HAS BEEN DROPPED OR
DAMAGED IN ANY WAY.
ANY REPAIRS TO THIS FIREPLACE
SHOULD BE PERFORMED BY A QUALIFIED
SERVICE TECHNICIAN.
DO NOT RUN ELECTRICAL WIRING OR
POWER CORD UNDER CARPETING. OR
COVER WITH THROW RUGS, RUNNERS
OR SIMILAR MATERIALS.
FOR 120 VAC POWER CORD AVOID THE
USE OF AN EXTENSION CORD BECAUSE
THE EXTENSION CORD MAY OVERHEAT
AND CAUSE A RISK OF FIRE. HOWEVER,
IF YOU HAVE TO USE AN EXTENSION
CORD, THE CORD SHALL BE NO. 14
AWG MINIMUM SIZE AND RATED NOT
LESS THAN 1800 WATTS, 15 AMPS. THE
EXTENSION CORD MUST BE A THREE
CONDUCTOR SHEATH CABLE WITH
GROUNDING TYPE PLUG AND CORD
CONNECTION.
THIS APPLIANCE HAS HOT AND ARCING
OR SPARKING PARTS INSIDE. DO NOT
USE IT IN AREAS WHERE GASOLINE,
PAINT OR FLAMMABLE LIQUIDS ARE
USED OR STORED.
THIS FIREPLACE SHOULD NOT BE USED
AS A DRYING RACK FOR CLOTHING, NOR
SHOULD CHRISTMAS STOCKINGS OR
OTHER DECORATIONS BE HUNG NEAR IT.
USE THIS APPLIANCE ONLY AS
DESCRIBED IN THIS MANUAL. ANY
OTHER USE IS NOT RECOMMENDED BY
THE MANUFACTURER AND MAY CAUSE
A FIRE, ELECTRIC SHOCK OR INJURY
TO PERSONS.
IF APPLIANCE IS TO BE DISCONNECTED,
TURN OFF CONTROLS FIRST.
IMPORTANT
These fi replaces are designed
as supplemental heaters. Therefore, it is advisable to have an
alternate heat source when
installed in a dwelling.
IMPORTANT
Cold climate installation recommendation: when installing this
fi replace against a non-insulated
exterior wall or chase, it is
mandatory that the outer walls
be insulated to conform to applicable insulation codes.
2
UNDER NO CIRCUMSTANCES SHOULD
THIS FIREPLACE BE MODIFIED. PARTS
HAVING TO BE REMOVED FOR SERVICING
MUST BE REPLACED PRIOR TO OPERATING THE FIREPLACE AGAIN.
DO NOT USE THIS APPLIANCE OUTDOORS. DO NOT EXPOSE FIREPLACE TO
THE ELEMENTS (SUCH AS RAIN, ETC.).
THIS APPLIANCE IS NOT INTENDED FOR
USE IN BATHROOMS, LAUNDRY AREAS
OR SIMILAR INDOOR LOCATIONS.
NEVER LOCATE THIS APPLIANCE WHERE
IT COULD FALL INTO A BATHTUB OR
OTHER WATER CONTAINER.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
DO NOT INSERT OR ALLOW FOREIGN
OBJECTS TO ENTER ANY VENTILATION
OR EXHAUST OPENING, AS THIS MAY
CAUSE AN ELECTRIC SHOCK, FIRE, OR
DAMAGE TO THE APPLIANCE.
SAVE THESE INSTRUCTIONS.
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
In selecting this Innovative Hearth Products linear electric fi replace, you have chosen
the fi nest and most dependable fi replace found anywhere. A beautiful and prestigious
addition to the fi nest homes. Welcome to a Family of hundreds of thousands of satisfi ed IHP Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please
pay special attention to the safety instructions provided in this manual. The instructions included here will assure that you have many years of dependable and enjoyable
service from your IHP product.
TABLE OF CONTENTS
Important Safety Information ........... Page 2
Packaging List .................................. Page 3
Installation must conform to local codes.
In the absence of local codes, electrical
wiring and grounding must comply with
the National Electrical Code ANSI/ NFPA
70 - latest edition. In Canada, the current
CSA C22-1 Canadian Electrical Code - latest
edition.
INTRODUCTION
This Electric Fireplace is designed for residential applications to be wall mounted or
framed in as a fi replace.
This appliance has been tested in accordance with UL 2021 and CSA C22.2 No.
46-M198 standards for fi xed and location
dedicated electric room heaters.
GENERAL INFORMATION
Power Supply Wire Specifi cations
120 Volt, 60 Hz, 1500 Watts:
Power is supplied to the fi replace through a
120Volt, 60Hz receptacle located withing reach
of the powercord provided with the fi replace.
If the heater option it to be used we suggest
that a separate circuit with breaker be used.
See Table 1.
TOOLS AND BUILDING SUPPLIES
NORMALLY REQUIRED
Power Supply Wire Gage
VoltageWire GageFuse
120 V14 GA.15 AMP
Table 1
LOCATING YOUR PRO SERIES ELECTRIC
FIREPLACE
Your new fi replace may be mounted on or
recessed into a wall (see Figure 1).
When choosing a location for your new fi replace, ensure that the general instructions are
followed. Also, for the best effect, install the
fi replace out of direct sunlight and away from
overhead lighting. See Figure 1.
Top View Showing Approved
Room Locations of Fireplace
fi replace shown in gray.
Figure 1
Please read and understand these
instructions before installing,
operating, or servicing this product.
PACKAGING LIST
This assembled Electric Room Heater is
packaged with:
• One accessory package located in the
fi rebox, containing;
1. One Installation and Operation Manual.
2. One Warranty Certifi cate (in manual)
3. One Remote Control.
900264-00 Rev. A 03/2017
TOOLS:
Phillips Screwdriver
Hammer
Saw And/or Saber Saw
Level
Measuring Tape
Plumb Line
Electric Drill And Bits
Pliers
Square
Gloves
BUILDING SUPPLIES:
Framing Materials
Wall Finishing Materials
IMPORTANT NOTE: This fi replace system
is not diffi cult to install. However, in the
interest of safety, it is recommended that
the installer be a qualifi ed or certifi ed
“tradesman” familiar with commonly
accepted fi replace installation and safety
techniques as well as prevailing local
codes.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
WALL MOUNTED AND RECESSED INSTALLATION
The Electric Fireplaces listed in this manual accept either wall-mounted installation or can be installed as a recessed appliance
for a more fi nished appearance.
WALL MOUNTING OPTION
Surface wall mounting can be achieved by securing the
provided brackets to a surface such as a wall in standard
construction after fi rst fi nding weight-bearing studs.
If this option is used, you will be able to enjoy the full
functionality of the fi replace, including light and heat.
NOTE: Minimum distances between walls, fl oors, and
ceilings must be observed. See Figure 2. Failure to do so
may result in damage to fi nishing materials on the wall
including but not limited to paint and wallpaper.
RECESSED FRAMING OPTION
These Electric Fireplaces offer a recessed installation (see Figure 3) that gives the fi replace a more distinguished
appearance.
Minimum distance from
ceiling 23-5/8” (600mm)
Blower Heat
Discharge Outlet
Minimum distance
to walls and fl oors
7-7/8” (200mm)
Figure 2
Recessed framing places the front glass on the unit nearly
fl ush with the wall. With this option, the fi replace will be
more permanently affi xed in its desired position in the
home for a more dramatic presentation.
With recessed installation, the heater in the unit
must be disabled by removing the access panel and
pulling apart a pair of wires to the blower (see Figure
6). In addition, the power switch must be enabled and
power will be controlled with the provided remote.
MODELA - HeightB - WidthC - Depth
54"18-5/8" (473mm)52" (1321mm)4-1/8" (105mm)
60"18-5/8" (473mm)52" (1321mm)4-1/8" (105mm)
4
A
C
Figure 3 - Recessed Framing Dimensions
Recessed Framing Dimensions
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Possible locations for
Electrical Receptacle/Outlet
B
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
WARNING
Do not use this fi replace if any
part of it has been underwater.
Immediately call a qualified
service technician to inspect the
fi replace and replace any part of
the electrical system which has
been under water.
WARNING
The minimum recommended
safe distance from the fi replace
to adjacent walls and furnishings
is 15 3/4" (600mm).
FIREPLACE SPECIFICATIONS
54" Models: ERC4054, Arturcus54,
Artesia54 and MPE-54L
Description: 54" Linear Electric Fireplace
Shipping Weight: 70-1/2 lbs. (32 KG)
Packaging:
57” x 6-1/2” x 22-3/8”
(1448mm x 165mm x 568mm)
This appliance is an electric fi replace designed
to be framed in with combustible materials (up
to the edge of the appliance).
Fireplace Clearances
WALLRECESS
Sides
Floor
Top
Rear0" (0mm)0" (0mm)
Table 2
Mantel Clearance: Combustible and Noncombustible mantels may be installed above
the top of the face of fi replace.
When surface mounting the fi replace with
the heater function enabled, a shelf must be
a minimum of 15-3/4" above the discharge of
the heater.
7-7/8"
(200mm)
7-7/8"
(200mm)
23-5/8"
(600mm)
0" (0mm)
0" (0mm)
0" (0mm)
PRE-INSTALLATION
Before You Start
Check appliance for any concealed damage.
DETAILED INSTALLATION STEPS
WALL MOUNTING
1. Do not connect the appliance until properly
fi xed to the wall and the instruction manual
is read fully.
2. Two people are recommended for installation
of this electric fi replace heater.
3. Peel off the removable label and the protective
sheet attached to the front tempered glass.
4. To place the decorative crystals media follow
the steps as given below
a. To place the crystals, the front glass is
required to be removed from the heater
panel body. Unscrew top and side screws
which hold the glass as shown in Figures
4a and 4b.
Figure 4b
b. Once the screws are out the top metal
bracket will come loose, place the
bracket away. Make sure the glass is
supported while doing this. Lift the
glass up and out from the heater body.
c. Place the crystals along the light unit
in desired position.
d. Put the front glass back and place the
metal bracket on top of the glass so that
the bracket secures it. Put the fasten
screws back. Make sure the screws are
tight and the glass is secured before
continuing with the installation.
5. A minimum recommended viewing distance
of 15" is recommended.
6. For installation of the appliance, care must
be taken not to damage concealed cables.
Please be careful while drilling the holes.
7. This appliance is designed to be permanently fi xed to a wall at a minimum height
of 7-7/8" (200mm). The wall bracket must
be fi tted horizontally and the cable routed
to the bot tom right of the heater.
8. A minimum height of 15" from bottom of
heater to fl oor is recommended for optimum viewing of fuel bed. See the Figure 2
for the recommended framing dimensions.
10. Carefully lift the heater up ensuring that the
top rear edge of heater engages the wall
bracket and is sitting centrally. Two people
will make this operation easier.
11. Gently bring the heater level with the wall
and hang the heater to the heater bracket.
Ensure the heater body is locked in with
the wall bracket.
12. Attach the bottom bracket to the heater
panel body and mark the mounting hole;
remove the heater.
13. Drill the bracket mounting hole and fi t the
wall plug.
14. Refi t the heater to the wall and secure the
bottom bracket using the screws provided
to permanently fi x the heater in place.
Ensure the heater body is engaged with
the wall bracket at the top. The heater is
now ready for use.
900264-00 Rev. A 03/2017
Figure 4a
5
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
WARNING
Electrical wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of fi re, electrical
shock and injury to individuals.
IMPORTANT
Any electrical re-wiring of this
appliance must be done by a
qualifi ed electrician.
ELECTRICAL CONNECTIONS FOR
RECESSED FRAMING OPTION
1. Complete the framing opening to the dimensions specifi ed in Figure 3. Disable the
blower as shown in Figure 5. Insure that the
fi replace is in the off position (see Figures
7 and 8).
2. Wire a dedicated, properly fused circuit with
an Amp rating for the appropriate voltage
(120 V - 15 Amps). A dedicated circuit is
required to prevent overloading a house
circuit in cases of having multiple appliances
on the same circuit. Use an outlet that is
protected by a ground fault circuit interrupter
where required by electrical code.
3. Prepare the connections to power receptacle:
120 Volt Connections - Locate the power
cord on the right side of the unit and connect
it to the outlet installed during the framing
(see Figure 5). Verify that the power to the
receptacle is off.
Hard wired installation:
Ensure that there is a minimum of 8" of the
service cable for connection to the junction
box on the fi replace.
- Loosen four screws to remove the junction
box cover plate.
- Disconnect and remove the 120 Volt power
cord from the fi replace wires.
- Position the fi replace into the framed-in
opening. Attach fi replace to frame using
nailing fl anges provided.
- Complete the wiring to the fi replace as
shown on Page 14.
4. Perform a function test. See Fireplace Heater
On/Off on Page 7 and Remote Control
Operation on Page 8.
5. Turn the master power switch to the "Off"
position and cut the power to the breaker
leading to the appliance.
RECESSED INSTALLATION
OPTION
Use the following detailed instructions for
recessed installation.
Installing the fi replace is a two person job.
1. Prepare the wall recess and electrical receptacle as see in Figure 3, Page 4. It may be
necessary to shim the wall bracket to the
wall forming the rear of the recess to meet
the minimum distance from the bracket to
the appliance (see Figure 7).
2. IMPORTANT: Cut off the breaker leading to
the appliance.
3. Follow the wiring details located in Figure 11 on Page 14.
3. Follow steps 1-5 found under WALL MOUNTING (see Page 5). to prepare decorative
elements of the fi replace for installation.
4. Install the mounting bracket on the inside
wall or on the shim.
5. Disable the blower motor and heater by
removing the four screws in the Heater Cutoff
Access Panel and unplugging the wires as
seen in Figure 5.
Figure 5
6. Flip the master power switch to the "ON"
position.
7. Carefully seat the fi replace into the recess
opening near the top of the opening and
lower the appliance so that the mounting
brackets will catch against the brackets at
the back of the fi replace.
8. Turn the breaker supporting the fi replace
back on.
9. Use the supplied remote control to operate the fi replace. For more information on
fi replace operation, see Page 8.
Recommended appliance
depth in wall
4- 5/8"
(118mm)
Back of
recessed
wall
1" (26mm)
Mounting
bracket
4-3/4"
(121mm)
Maximum recess depth
Front of
finished
wall
Glass
overlap
Fireplace
When the fi replace is fully installed using
the recess option, the viewing glass
should overlap the top opening framing
approximately 1" (26mm) and extend to
conceal the framing. See Figure 6 above.
Figure 6
BREAK-IN PERIOD:
During the fi rst few initial uses of this heater,
there may be a release of a slight, harmless odor.
This odor is a normal occurrence caused by the
initial heating of the internal heating elements
and should not reoccur.
6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
NOTE: Ensure the circuit breakers for the
power supply are turned on.
This appliance can be activated using the fi replace and heater On/Off Switch (see Figures 7 and 8) or by using the remote control when the
unit power switch is already in the "ON" position.
The manual controls are located on the fi rebox
fl oor on the front left (see Figure 5). If an
optional glass enclosure is installed, it must
be removed to access.
Fireplace and Heater On/Off
When the main power switch is turned on,
power is supplied to the fi replace.
On
Off
The On/Off Switch is located on the right
side of the unit below the Heater Cutoff
Access Panel. In the recessed install
option, this switch must be turned into
the "ON" position and the appliance must
be controlled with the remote provided.
Figure 7
MAINTENANCE
This appliance has been designed to provide
many years of trouble-free service. The components that will need to be serviced have been
kept to a minimum. Periodic dusting of the
fi replace is all that should be required.
CAUTION
Handle glass very carefully to
prevent accidental breakage.
CAUTION
Disconnect power before attempting any maintenance or cleaning
to reduce the risk of fi re, electrical shock or personal injury.
WARNING
When cleaning the fi replace, the
fi replace must be cool.
CLEANING THE GLASS ENCLOSURE
PANEL
Over time the front glass panel may become
dirty or dusty. Dust can be removed by lightly
rubbing the glass surface with a clean, lint free
cloth or paper towel. To remove fi ngerprints
or other marks, use a damp cloth with a good
quality household glass cleaner. The front glass
panel should be completely dried with a clean,
lint free cloth or paper towel.
CAUTION
Do not use abrasive cleaners on
the glass panel. Do not spray
liquids directly onto any surface
of the fi replace.
OPERATION
The appliance can be turned on either by the
switch located on the lower right hand side of
the heater body or by supplied remote control.
Manual Operation
1. The main power ON/OFF switch in position
“O,” the heater is OFF.
2. When main power ON/OFF switch is at position “I,” the heater is ready to use.
3. Press the HEAT button on the remote control
repeatedly to set the heater to desired heat
setting.
4. Press the Flame brightness adjustment
button to adjust the fl ame height and ember
bed brightness. Press and release the FLAME
control button to cycle through LO, MED,
HI and OFF.
SAFETY CUT-OFF
• This appliance is fi tted with a safety
cut-off which will operate if the heater
overheats (eg. due to blocked air
vents). For safety reasons, the heater
will NOT automatically reset.
• To reset the appliance, disconnect
the appliance from the mains supply
for at least 30 minutes. Reconnect
the supply to the main switch on the
appliance.
AUTO MODE
Under this mode the heater will automatically
turn ON at high heat setting 1500w heat output
when the room temperature drops below 72˚F
(22˚ C). When the room temperature is between
72-77˚F (22-25˚ C) the heater output will switch
to low heat set ting 1000W. When the room
temperature goes above 77˚F (25˚ C) the heater
will be turned off and the cycle will continue.
Main Power Switch in "OFF" Position.
Figure 8
900264-00 Rev. A 03/2017
WARNING
An authorized service representative should perform any other
servicing.
7
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
REMOTE CONTROL OPERATION:
REMOTE CONTROL
A
B
C
D
E
F
G
I
H
J
• When using the remote control, the power
on/off switch on the lower right side of the
unit must be in the "ON" position.
Figure 9
REMOTE CONTROL MODEL NO. R-37
PART NO. F2052
K
CAUTIONS
• Do Not Use Old Batteries With
New Ones.
• Do Not Use Batteries Other Than
The Type Specifi ed (2 Ea. AA).
• Ensure Batteries Are Correctly
Installed In Remote Control.
This IHP Electric Fireplace is provided with an
Infrared light Remote Control. All functions
of the fi replace can be controlled through the
remote control. Note: The Effective range of
the remote control is up to approximately 26
feet (8 meters).
The functions identifi ed on the remote (see
Figure 9) are as follows:
A. POWER BUTTON
Press once to turn on power to fi replace.
B. INDICATING LIGHT
Illuminates when signal is sent.
C. FLAME BUTTON
On/off switch for fl ame and ember light.
D. AMBER FLAME BUTTON (DIM)
Reduces brightness of amber light.
E. AMBER FLAME BUTTON (BRIGHTEN)
Increases brightness of amber light.
F. HEATER ON/OFF
This button will turn the heater ON and OFF
independent of the main button.
G. TEMPERATURE ADJUSTMENT BUTTON
(HIGH)
Highest heat output, up to 75° F.
H. TEMPERATURE ADJUSTMENT BUTTON
(LOW.)
Low heat output, up to 72° F.
I. TEMPERATURE ADJUSTMENT BUTTON
(ROOM)
Sets the fi replace to Auto Mode (See Opera-
tions)
J. BLUE FLAME BUTTON (LOWER)
Reduces brightness of blue light.
K. BLUE FLAME BUTTON (HIGHER)
Increases brightness of blue light.
REMOTE CONTROL OPERATION STEPS:
1. For remote to function make sure the
heater is plugged-in and main power switch
located on the bottom right hand side is in
the “ON” position.
2. When operating the remote make sure you
point the remote to the center of the heater
unit and make sure each time you press
the button the LED indicator located on
top right hand corner of the remote blinks.
The buzzer inside the unit will beep once; if
the LED fails to blink check the batteries. It
takes some time for the receiver to respond
to the transmitter. Do not PRESS the buttons more than once within two seconds
for correct operation.
3. Power On power button: The power-on
button at top left corner of the remote is
the main ON/OFF power button. This will
turn off all the functions and the heater will
be in standby mode.
4. Flame Power On button: This button controls both the amber and blue color fl ame.
Press this button once to turn ON the fl ame
effect. Once the fl ame effect is ON use the +
and – but tons as explained below to adjust
the fl ame brightness as desired. Press this
button again to turn OFF the fl ame effect.
The heater can function even when the
fl ame effect is turned off if so desired.
The Red Flame +5 or -5 buttons control the
brightness of the Amber fame. To increase
the brightness/fl ame height, press and
release the fl ame +5 button. Each time you
press this button the brightness will increase
by a small amount, until the maximum is
reached.
Press and release the Red Flame -5 button.
Each time you press this button the brightness will decrease by small amount, until
the minimum brightness is reached.
The Blue Flame +5 or -5 buttons control the
brightness of the Blue fame. To increase the
brightness/fl ame height, press and release
the Blue Flame +5 button. Each time you
press this button the brightness will increase
by a small amount, until the maximum is
reached.
To decrease the brightness / fl ame height,
press and release the Blue Flame -5 button.
Each time you press this but ton the brightness will decrease by small amount, until
the minimum brightness is reached.
Using these settings you can mix the amber
and the blue fl ame to create a realistic or
stylized fl ame effect. Color mixes will also
be refl ected in the crystal ember bed for
added impact.
5. Heater Power Button: This button is the
heater ON/OFF button. Press this button to
turn the heater ON. The heater will always
turn on at the highest setting. In order to
reduce the temperature on the heater press
this button again.
High Button: Press the high button to switch
the heater directly to high heat setting of
1500W.
Low Button: Press the high button to switch
the heater directly to low heat setting of
750W.
Room Temp Button: Press the high but ton
to switch the heater to AUTO Mode (See
Operations, Page 7).
6. To turn OFF the heater unit completely press the Power Button once.
8
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
54" LINEAR ELECTRIC FIREPLACE
47” (1194mm)
LEFT
SIDE
VIEW
4-3/4”
(120mm)
TOP VIEW
54” (1372mm)
FRONT VIEW
7-5/8” (194mm)
RIGHT
SIDE
VIEW
20”
(508mm)
BOTTOM VIEW
22-1/2”
(572mm)
BACK VIEW
900264-00 Rev. A 03/2017
9
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
)
4
)
(
)
)
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
60" LINEAR ELECTRIC FIREPLACE
7” (1194mm
7-5/8” (194mm
TOP VIEW
17-1/8
(436mm)
4-3/4”
121mm
LEFT
SIDE
VIEW
60” (1524mm)
FRONT VIEW
BOTTOM VIEW
22-1/2” (572mm
9-5/8”
(244mm)
5-1/4”
(134mm)
RIGHT
SIDE
VIEW
20”
(508mm)
BACK VIEW
MOUNTING BRACKET
25” (635mm)
>1”
2”
(51mm)
4”
(102mm)
12” (305mm)
22-1/2” (572 mm)
10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
(26mm)
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
TROUBLESHOOTING
SymptomPossible Causes
1. Fireplace does not turn on when
the power button on the remote is
pushed.
2. Fireplace does not turn on when
main power switch is engaged.
Main power switch on the lower
right side of the fi replace is in the
off position.
Appliance is not plugged in or there
is no power to the receptacle
3. Flame is fi xed (unmoving).Wiring may be loose or the fl ame
motor may be defective.
Who Performs
Corrective Action
Corrective Action
HomeownerTurn on the main power switch.
HomeownerPlug unit in or confi rm that the circuit
breaker is switched on.
Qualifi ed service technicianInspect all wiring for loose connections.
If the wire connections are good, replace
the fl ame motor.
4. Dim or poorly visible fl ame or LED
ember bed is not glowing.
LED strip failure or wiring is loose.Qualifi ed service technicianInspect all wiring for loose connec-
tions and repair or replace if necessary. Inspect LED strips and replace
if necessary.
5. Flame sputters.Flame motor is defective.Qualifi ed service technicianReplace fl ame motor.
6. Remote control does not work.Low batteries. Unit switch and/or wall
switch in “on” position.
HomeownerReplace aa batteries in remote control.
If problem persists, there may have been
a loss of power to the unit as a possible
result from a power failure (i.E. Breaker
tripped).
Turn off main power on/off switch (see
fi gure 4) and/or optional wall switch (if
applicable).
7. Circuit breaker trips or fuse blows
when the unit is turned on.
Improper circuit current rating.Qualifi ed service technicianCheck the house circuit to ensure it is
on a dedicated circuit with proper amp.
Rating. If the circuit breaker continues
to trip (or blown fuses), inspect wiring
for a loose connection or a dead short.
Repair or replace wiring and/or connectors as necessary.
900264-00 Rev. A 03/2017
11
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
EXPLODED DIAGRAM KEY AND AVAILABLE REPLACEMENT PARTS
ITEM
NO.
1Front GlassF2042F20431
2Bottom Front Glass Fixed BarN/AN/A1
3Top Front Glass Fixed BarN/AN/A1
4Lower Baffl eN/AN/A1
5Ember Bed BracketN/AN/A1
6Translucent LED Ember CoverN/AN/A1
7Mirror GlassF2044F20441
8Isolation ColumnsN/AN/A1
9Ember Bed LED LightsF2045F20454
10Flame BoardN/AN/A1
11Drum BracketN/AN/A1
12Flame Drum AssemblyF2046F20461
13Plastic HandleN/AN/A1
14Left Side PanelN/AN/A1
15Left Inner Lining BoardN/AN/A1
16Upper BarN/AN/A1
17Upper PanelN/AN/A1
18Remote Receiver AssemblyF2048F20481
19Air Outlet BracketN/AN/A1
20Heater AssemblyF2049F20491
21Circuit/Control BoardF2050F20501
22FireboxN/AN/A1
23Right Lining PanelN/AN/A1
24Right Side PanelN/AN/A1
25Heater Cutoff Access PanelN/AN/A1
26Rocker SwitchF2051F20511
27Power Supply LinesN/AN/A1
28Power CordN/AN/A1
---Remote Control (see Page 8)F2052F20521
---Wall Mounting Bracket (see Page 10)F2053F20531
---Flame Drum Motor (Not Shown)F2047F20471
---Ember Crystals (Not Shown)F2054F2054
DESCRIPTION
54" Models60" Models
Cat. No.Cat. No.
QTY
2
NOTE: If touch-up paint is needed, use Rust-oleum®, Painter’s Touch, Flat Black (part number 1976) available at most stores which sell aerosol touch-up paint.
12
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
EXPLODED DIAGRAM WITH AVAILABLE REPLACEMENT PARTS - 54" AND 60" MODELS
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally
approved with this appliance may result in property damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas
et ou si des pièces autres que celles spécifi quement approuvées avec cet appareil sont utilisées.
WARNING
Never use substitute materials. Use of non-approved parts can result in poor performance and safety
hazards.
900264-00 Rev. A 03/2017
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
13
N
6.3*0.8
L1
N
P-NI
HS0038
GND
GND
5V 47uF
2
GND
C4
104
C6
5v
GND
2.4*7
11
P5.2
SN8P2722
P5.1
10
R12
510
12345
6
R5
10K
GND
12
P5.3
510
ELECTRICAL DIAGRAM
R3
10K
t
25*C,5K
THERMISTOR
TEMP
P5.0
SIP2
9
R11
5
P0.4
GND
104
1K
GND
C5
2.4*2
R2
104
16
P4.2/AIN2
10K
C2
1
2
R8
15
P4.1/AIN1
GND
P0.7
510
3V-4
V+
2
2.2nF/250VAC
R13
27
C9
+12V
7805IC1
+5V
D9
AC
AC
1
6.3*0.8
FUSE2
F1
PTC
2.2nF/250VAC
6.3*0.58
6.3*0.8
390PF
P-SW
S1
PH-7
TEMP_BRK
PH-6
P-L
C14
1M
LTV817A
U1B
1K
R17
FR106
R14
2M
GND
GND
L2
6mH
R16
D7
GND
35V 680uF
1KU/16V
400V 22U
TNY1
5-8
TNY278PN
+5V
C12
16V 10U
BUZ1
SS8050
T3
D1
P0.5
4007
GND
P0.6
6
R4
510
2
P0.1
8
R10
4
1
2
U1A
LTV817A
+5V
D6
12V
10
VSS
20
VDD
P0.2
7
3
400V 22U
2
6
C7
100U 16V
C8
2
GND
C1
104
R15
2M
P6KE200
EF1
D4 SB3100
3.3uH
100/0.5W
C3
D8
1
7
Vin
Vout
2KBP06M
C13
C10
C11
L1
R1
1
3
14
GND
PH-4
6.3*0.8
T6
D3
RELAY-H2
FAN MOTOR
+12V
GND
6.3*0.8
H1
8050
1N4007
H1+FAN
T5
D2
RELAY-H1
+12V
510
GND
100
LED8LED7
R9
T4
SS8050
2.4*2
2.4*2
LED6LED5
LED-M
1
2
LAMP
1
2
+12V
GND
100
LED8LED7
R6 510
SS8050
100
R?
LED6LED5
LED-HB
2.4*2
1
2
2.4*2
FIRE-Y
1
2
+12V
T2
GND
R?
180
LED2
LED3
R7
510
T1
SS8050
2.4*2
2.4*2
R?
180
DS?
LED1D1
DS?
LED-HY
1
2
FIRE-B
1
2
+12V
180
R?
8050
+12V
1N4007
D5
RELAY-MOTOR
MOTOR
6.3*0.8
MOTOR
6.3*0.8
8050
1N4007
H2 PH-2
H2
GND
T7
Innovative Hearth Products
Electric Fireplace
Limited One Year Warranty
THE WARRANTY
Innovative Hearth Products Limited One Year Warranty ("IHP") warrants your electric fi replace, appliance or insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The product body, blower and circuit board, if applicable, carry the Limited One Year Warranty. After installation, if covered components
are found to be defective in materials or workmanship during the Limited One Year Warranty period and while the Product remains at the site of the original installation,
IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price
or wholesale price of the IHP Product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or
replacing such components. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited One Year Warranty as described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six
months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following
the date of product shipment from IHP, regardless of the installation or occupancy date.
EXCLUSIONS AND LIMITATIONS
This Limited One Year Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be
provided. The following do not carry a Limited One Year Warranty but are warranted as follows:
Glass components – Replacement for 90 days from the date of installation
Accessories & doors – Repair or replacement for 90 days from the date of installation
Light bulbs, LED strips & batteries – Replacement for 90 days from the date of installation for defects in material and workmanship only
Remote control – Repair or replacement for one year from the date of installation
Labor coverage – Prevailing IHP labor charges apply for the warranty period of the component
Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse,
or unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. All precautions and warnings as
described in the instruction/owner’s manual must be followed.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.
This Limited One Year Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are not
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to
any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.
LIMITATION ON LIABILITY
It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied,
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Products, whether such damage occurs or is discovered before or
after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a
particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited One Year Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited One Year Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited
One Year Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
IHP reserves the right to investigate any and all claims against this Limited One Year Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefi ts and advantages described in this Limited One Year Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a
contractor that is not approved without fi rst obtaining IHP's prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the
IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.IHP.US.COM.
Innovative Hearth Products
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
15
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION INSTRUCTIONS
IHP.us.com
Record the following important information about your appliance:
Appliance model number
Appliance serial number
Date appliance was Installed
Dealer name
16
IHP reserves the right to make changes at any time, without notice, in design, materials,
specifi cations, prices and also to discontinue colors, styles and products. Consult your local
distributor for fi replace code information.