IHP Arcturus54, Arcturus60, Artesia54, Artesia60, ERC4054 Installation And Operation Instructions Manual

...
Installation and Operation Instructions
54" AND 60" LINEAR ELECTRIC FIREPLACES
54" and 60" Linear Electric Fireplaces P/N 900264-00 Rev. A 03/2017
MODELS
INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference
INSTALLATEUR : Laissez cette notice avec l’appareil. CONSOMMATEUR : Conservez cette notice pour con­sultation ultérieure.
A French manual is available upon request. Order P/N 900278-00 Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 900278-00.
IMPORTANT! TO ASSURE PROPER ALIGNMENT, INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES.
Arcturus54 Arcturus60
This manual will enable you to obtain a safe, effi cient and depend­able installation and operation of your electric fi replace. Please read and understand these instructions before beginning your installation.
Do not alter or modify this fi replace or its components under any circumstances. Any modifi cation or alteration of the fi replace system, including but not limited to the fi replace and accessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
EXPOSED SURFACES OF THE ELECTRONIC FIREPLACE ADJACENT TO HEATERS AND BLOWERS MAY BECOME HOT. CARE SHOULD BE TAKEN TO AVOID CONTACT WITH BLOWER HEAT DISCHARGE OUTLETS SUCH AS THE ONE ON THE TOP OF THIS FIREPLACE.
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUS­ING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
Artesia54 Artesia60
FOR YOUR SAFETY
ERC4054 ERC4060
MPE-54L MPE-60L
IHP electric fi replaces are designed for use as a decorative appli­ance and/or as a supplemental heater. They are not intended for continuous use as a primary heat source.
C
®
US
Report # 1906849
P900264-00
BEFORE STARTING YOUR FIREPLACE INSTALLATION, READ THIS INSTALLATION AND OPERATION MANUAL VERY CAREFULLY TO ENSURE YOU UNDERSTAND IT COMPLETELY AND IN ENTIRETY. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A POSSIBLE ELECTRIC SHOCK, FIRE HAZARD AND/OR INJURY OR PROPERTY DAMAGE AND WILL VOID THE WARRANTY.
EXTREME CAUTION IS NECESSARY WHEN ANY HEATER IS USED BY OR NEAR CHILDREN OR INVALIDS AND WHENEVER THE HEATER IS LEFT OPERATING AND UNATTENDED.
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
IMPORTANT SAFETY AND WARNING INFORMATION
READ THIS MANUAL IN ITS ENTIRETY AND UNDERSTAND THESE RULES TO FOLLOW FOR SAFETY.
WARNING
If the information in this manual is not followed exactly, an elec­trical shock or fi re may result causing property damage, per­sonal injury or loss of life.
IMPORTANT
Before starting your fi replace installation, read this instal­lation and operation manual very carefully to ensure you understand it completely and in entirety. Failure to follow these instructions may result in a pos­sible electric shock, fi re hazard and/or injury or property damage and will void the warranty.
CAUTION
Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left oper­ating and unattended.
WARNING
To prevent contact with sag­ging or loose insulation, the appliance must not be installed against vapor barriers or exposed insulation. Localized overheat­ing could occur and a fi re could result. Insulation and a vapor barrier should be placed a minimum of 2 inches from the appliance.
TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKES OR EXHAUSTS IN ANY WAY. DO NOT USE NEAR SOFT SURFACES, LIKE A PILLOW, WHERE OPENINGS MAY BECOME BLOCKED.
THIS APPLIANCE MAY BECOME HOT WHEN IN USE. TO AVOID BURNS, DO NOT LET BARE SKIN TOUCH HOT SURFACES. KEEP COMBUSTIBLE MATERIALS, SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS, CLOTHES AND CURTAINS AT LEAST 3 FEET (1 METER) FROM THE FRONT OF THIS APPLIANCE.
DO NOT OPERATE ANY HEATER WITH DAMAGED WIRING OR CONNECTORS, OR AFTER THE APPLIANCE MALFUNC­TIONS, OR IF IT HAS BEEN DROPPED OR DAMAGED IN ANY WAY.
ANY REPAIRS TO THIS FIREPLACE SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN.
DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING. OR COVER WITH THROW RUGS, RUNNERS OR SIMILAR MATERIALS.
FOR 120 VAC POWER CORD AVOID THE USE OF AN EXTENSION CORD BECAUSE THE EXTENSION CORD MAY OVERHEAT AND CAUSE A RISK OF FIRE. HOWEVER, IF YOU HAVE TO USE AN EXTENSION CORD, THE CORD SHALL BE NO. 14 AWG MINIMUM SIZE AND RATED NOT LESS THAN 1800 WATTS, 15 AMPS. THE EXTENSION CORD MUST BE A THREE CONDUCTOR SHEATH CABLE WITH GROUNDING TYPE PLUG AND CORD CONNECTION.
THIS APPLIANCE HAS HOT AND ARCING OR SPARKING PARTS INSIDE. DO NOT USE IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE USED OR STORED.
THIS FIREPLACE SHOULD NOT BE USED AS A DRYING RACK FOR CLOTHING, NOR SHOULD CHRISTMAS STOCKINGS OR OTHER DECORATIONS BE HUNG NEAR IT.
USE THIS APPLIANCE ONLY AS DESCRIBED IN THIS MANUAL. ANY OTHER USE IS NOT RECOMMENDED BY THE MANUFACTURER AND MAY CAUSE A FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS.
IF APPLIANCE IS TO BE DISCONNECTED, TURN OFF CONTROLS FIRST.
IMPORTANT
These fi replaces are designed as supplemental heaters. There­fore, it is advisable to have an alternate heat source when installed in a dwelling.
IMPORTANT
Cold climate installation recom­mendation: when installing this fi replace against a non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to appli­cable insulation codes.
2
UNDER NO CIRCUMSTANCES SHOULD THIS FIREPLACE BE MODIFIED. PARTS HAVING TO BE REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERAT­ING THE FIREPLACE AGAIN.
DO NOT USE THIS APPLIANCE OUT­DOORS. DO NOT EXPOSE FIREPLACE TO THE ELEMENTS (SUCH AS RAIN, ETC.).
THIS APPLIANCE IS NOT INTENDED FOR USE IN BATHROOMS, LAUNDRY AREAS OR SIMILAR INDOOR LOCATIONS. NEVER LOCATE THIS APPLIANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CONTAINER.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
DO NOT INSERT OR ALLOW FOREIGN OBJECTS TO ENTER ANY VENTILATION OR EXHAUST OPENING, AS THIS MAY CAUSE AN ELECTRIC SHOCK, FIRE, OR DAMAGE TO THE APPLIANCE.
SAVE THESE INSTRUCTIONS.
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
In selecting this Innovative Hearth Products linear electric fi replace, you have chosen the fi nest and most dependable fi replace found anywhere. A beautiful and prestigious addition to the fi nest homes. Welcome to a Family of hundreds of thousands of satis­fi ed IHP Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The instruc­tions included here will assure that you have many years of dependable and enjoyable service from your IHP product.
TABLE OF CONTENTS
Important Safety Information ........... Page 2
Packaging List .................................. Page 3
Introduction ..................................... Page 3
General Information ......................... Page 3
Locating Fireplace ............................ Page 3
Tools/Supplies Required .................. Page 3
Framing Specifi cations ..................... Page 4
Fireplace Specifi cations .................... Page 4
Clearances ....................................... Page 5
Pre-installation ................................. Page 5
Installation Steps ............................. Page 5
Electrical Connections ...................... Page 6
Final Finishing .................................. Page 6
Break-In Period ................................ Page 6
On/Off Switch ................................... Page 6
Remote Control Operation ............... Page 7
Operation Modes .............................. Page 7
Maintenance ..................................... Page 8
54" Fireplace Specifi cations .............. Page 9
60" Fireplace Specifi cations .............. Page 10
Troubleshooting ............................... Page 11
Exploded Diagram Key ..................... Page 12
Available Replacement Parts ............ Page 12
Exploded Diagram ............................ Page 13
Electrical Diagram ............................ Page 14
Warranty .......................................... Page 15
Installation must conform to local codes. In the absence of local codes, electrical wiring and grounding must comply with the National Electrical Code ANSI/ NFPA 70 - latest edition. In Canada, the current CSA C22-1 Canadian Electrical Code - latest edition.
INTRODUCTION
This Electric Fireplace is designed for resi­dential applications to be wall mounted or framed in as a fi replace.
This appliance has been tested in accor­dance with UL 2021 and CSA C22.2 No. 46-M198 standards for fi xed and location dedicated electric room heaters.
GENERAL INFORMATION
Power Supply Wire Specifi cations
120 Volt, 60 Hz, 1500 Watts:
Power is supplied to the fi replace through a 120Volt, 60Hz receptacle located withing reach of the powercord provided with the fi replace. If the heater option it to be used we suggest that a separate circuit with breaker be used. See Table 1.
TOOLS AND BUILDING SUPPLIES NORMALLY REQUIRED
Power Supply Wire Gage
Voltage Wire Gage Fuse
120 V 14 GA. 15 AMP
Table 1
LOCATING YOUR PRO SERIES ELECTRIC FIREPLACE
Your new fi replace may be mounted on or recessed into a wall (see Figure 1).
When choosing a location for your new fi re­place, ensure that the general instructions are followed. Also, for the best effect, install the fi replace out of direct sunlight and away from overhead lighting. See Figure 1.
Top View Showing Approved
Room Locations of Fireplace
fi replace shown in gray.
Figure 1
Please read and understand these
instructions before installing,
operating, or servicing this product.
PACKAGING LIST
This assembled Electric Room Heater is packaged with:
• One accessory package located in the fi rebox, containing;
1. One Installation and Operation Manual.
2. One Warranty Certifi cate (in manual)
3. One Remote Control.
900264-00 Rev. A 03/2017
TOOLS:
Phillips Screwdriver Hammer Saw And/or Saber Saw Level Measuring Tape Plumb Line Electric Drill And Bits Pliers Square Gloves
BUILDING SUPPLIES:
Framing Materials Wall Finishing Materials
IMPORTANT NOTE: This fi replace system is not diffi cult to install. However, in the interest of safety, it is recommended that the installer be a qualifi ed or certifi ed “tradesman” familiar with commonly accepted fi replace installation and safety techniques as well as prevailing local codes.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
WALL MOUNTED AND RECESSED INSTALLATION
The Electric Fireplaces listed in this manual accept either wall-mounted installation or can be installed as a recessed appliance for a more fi nished appearance.
WALL MOUNTING OPTION
Surface wall mounting can be achieved by securing the provided brackets to a surface such as a wall in standard construction after fi rst fi nding weight-bearing studs.
If this option is used, you will be able to enjoy the full functionality of the fi replace, including light and heat.
NOTE: Minimum distances between walls, fl oors, and ceilings must be observed. See Figure 2. Failure to do so may result in damage to fi nishing materials on the wall including but not limited to paint and wallpaper.
RECESSED FRAMING OPTION
These Electric Fireplaces offer a recessed installation (see Figure 3) that gives the fi replace a more distinguished appearance.
Minimum distance from ceiling 23-5/8” (600mm)
Blower Heat Discharge Outlet
Minimum distance to walls and fl oors 7-7/8” (200mm)
Figure 2
Recessed framing places the front glass on the unit nearly fl ush with the wall. With this option, the fi replace will be more permanently affi xed in its desired position in the home for a more dramatic presentation.
With recessed installation, the heater in the unit must be disabled by removing the access panel and pulling apart a pair of wires to the blower (see Figure
6). In addition, the power switch must be enabled and power will be controlled with the provided remote.
MODEL A - Height B - Width C - Depth
54" 18-5/8" (473mm) 52" (1321mm) 4-1/8" (105mm)
60" 18-5/8" (473mm) 52" (1321mm) 4-1/8" (105mm)
4
A
C
Figure 3 - Recessed Framing Dimensions
Recessed Framing Dimensions
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Possible locations for Electrical Receptacle/Outlet
B
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
WARNING
Do not use this fi replace if any part of it has been underwater. Immediately call a qualified service technician to inspect the fi replace and replace any part of the electrical system which has been under water.
WARNING
The minimum recommended safe distance from the fi replace to adjacent walls and furnishings is 15 3/4" (600mm).
FIREPLACE SPECIFICATIONS
54" Models: ERC4054, Arturcus54, Artesia54 and MPE-54L
Description: 54" Linear Electric Fireplace Shipping Weight: 70-1/2 lbs. (32 KG) Packaging: 57” x 6-1/2” x 22-3/8” (1448mm x 165mm x 568mm)
4.94 cu. ft.
Power Requirements: (120 Volt, 60 Hz.) Rated Wattage - 1600 Watts Amperage - 13.33 Amps Blower CFM: 83 CFM (120 V): 5,461 BTU/HR
60" Models: ERC4060, Arturcus60,
Artesia60 and MPE-60L
Description: 60" Linear Electric Fireplace Shipping Weight: 72-3/4 lbs. (33 KG) Packaging: 62-3/8” x 6-1/2” x 22-3/8”WWW (1584mm x 165mm x 568mm)
5.3 cu. ft.
Power Requirements: (120 Volt, 60 Hz.) Rated Wattage - 1600 Watts Amperage - 13.33 Amps Blower CFM: 83 CFM (120 V): 5,461 BTU/HR
MINIMUM CLEARANCES TO COMBUS­TIBLES
This appliance is an electric fi replace designed to be framed in with combustible materials (up to the edge of the appliance).
Fireplace Clearances
WALL RECESS
Sides
Floor
Top
Rear 0" (0mm) 0" (0mm)
Table 2
Mantel Clearance: Combustible and Non­combustible mantels may be installed above the top of the face of fi replace.
When surface mounting the fi replace with the heater function enabled, a shelf must be a minimum of 15-3/4" above the discharge of the heater.
7-7/8"
(200mm)
7-7/8"
(200mm)
23-5/8"
(600mm)
0" (0mm)
0" (0mm)
0" (0mm)
PRE-INSTALLATION
Before You Start
Check appliance for any concealed damage.
DETAILED INSTALLATION STEPS
WALL MOUNTING
1. Do not connect the appliance until properly fi xed to the wall and the instruction manual is read fully.
2. Two people are recommended for installation of this electric fi replace heater.
3. Peel off the removable label and the protective sheet attached to the front tempered glass.
4. To place the decorative crystals media follow the steps as given below
a. To place the crystals, the front glass is
required to be removed from the heater panel body. Unscrew top and side screws which hold the glass as shown in Figures
4a and 4b.
Figure 4b
b. Once the screws are out the top metal
bracket will come loose, place the bracket away. Make sure the glass is supported while doing this. Lift the glass up and out from the heater body.
c. Place the crystals along the light unit
in desired position.
d. Put the front glass back and place the
metal bracket on top of the glass so that the bracket secures it. Put the fasten screws back. Make sure the screws are tight and the glass is secured before continuing with the installation.
5. A minimum recommended viewing distance of 15" is recommended.
6. For installation of the appliance, care must be taken not to damage concealed cables. Please be careful while drilling the holes.
7. This appliance is designed to be perma­nently fi xed to a wall at a minimum height of 7-7/8" (200mm). The wall bracket must be fi tted horizontally and the cable routed to the bot tom right of the heater.
8. A minimum height of 15" from bottom of heater to fl oor is recommended for opti­mum viewing of fuel bed. See the Figure 2 for the recommended framing dimensions.
10. Carefully lift the heater up ensuring that the top rear edge of heater engages the wall bracket and is sitting centrally. Two people will make this operation easier.
11. Gently bring the heater level with the wall and hang the heater to the heater bracket. Ensure the heater body is locked in with the wall bracket.
12. Attach the bottom bracket to the heater panel body and mark the mounting hole; remove the heater.
13. Drill the bracket mounting hole and fi t the wall plug.
14. Refi t the heater to the wall and secure the bottom bracket using the screws provided to permanently fi x the heater in place. Ensure the heater body is engaged with the wall bracket at the top. The heater is now ready for use.
900264-00 Rev. A 03/2017
Figure 4a
5
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
WARNING
Electrical wiring must comply with local building codes and other applicable regulations to reduce the risk of fi re, electrical shock and injury to individuals.
IMPORTANT
Any electrical re-wiring of this appliance must be done by a qualifi ed electrician.
ELECTRICAL CONNECTIONS FOR RECESSED FRAMING OPTION
1. Complete the framing opening to the dimen­sions specifi ed in Figure 3. Disable the blower as shown in Figure 5. Insure that the fi replace is in the off position (see Figures
7 and 8).
2. Wire a dedicated, properly fused circuit with an Amp rating for the appropriate voltage (120 V - 15 Amps). A dedicated circuit is required to prevent overloading a house circuit in cases of having multiple appliances on the same circuit. Use an outlet that is protected by a ground fault circuit interrupter where required by electrical code.
3. Prepare the connections to power receptacle:
120 Volt Connections - Locate the power
cord on the right side of the unit and connect it to the outlet installed during the framing (see Figure 5). Verify that the power to the receptacle is off.
Hard wired installation: Ensure that there is a minimum of 8" of the
service cable for connection to the junction box on the fi replace.
- Loosen four screws to remove the junction box cover plate.
- Disconnect and remove the 120 Volt power cord from the fi replace wires.
- Position the fi replace into the framed-in opening. Attach fi replace to frame using nailing fl anges provided.
- Complete the wiring to the fi replace as shown on Page 14.
4. Perform a function test. See Fireplace Heater
On/Off on Page 7 and Remote Control Operation on Page 8.
5. Turn the master power switch to the "Off" position and cut the power to the breaker leading to the appliance.
RECESSED INSTALLATION OPTION
Use the following detailed instructions for recessed installation.
Installing the fi replace is a two person job.
1. Prepare the wall recess and electrical recep­tacle as see in Figure 3, Page 4. It may be necessary to shim the wall bracket to the wall forming the rear of the recess to meet the minimum distance from the bracket to the appliance (see Figure 7).
2. IMPORTANT: Cut off the breaker leading to the appliance.
3. Follow the wiring details located in Figure 11 on Page 14.
3. Follow steps 1-5 found under WALL MOUNT­ING (see Page 5). to prepare decorative elements of the fi replace for installation.
4. Install the mounting bracket on the inside wall or on the shim.
5. Disable the blower motor and heater by removing the four screws in the Heater Cutoff Access Panel and unplugging the wires as seen in Figure 5.
Figure 5
6. Flip the master power switch to the "ON" position.
7. Carefully seat the fi replace into the recess opening near the top of the opening and lower the appliance so that the mounting brackets will catch against the brackets at the back of the fi replace.
8. Turn the breaker supporting the fi replace back on.
9. Use the supplied remote control to oper­ate the fi replace. For more information on fi replace operation, see Page 8.
Recommended appliance
depth in wall
4- 5/8"
(118mm)
Back of recessed wall
1" (26mm)
Mounting bracket
4-3/4"
(121mm)
Maximum recess depth
Front of finished wall
Glass overlap
Fireplace
When the fi replace is fully installed using the recess option, the viewing glass should overlap the top opening framing approximately 1" (26mm) and extend to conceal the framing. See Figure 6 above.
Figure 6
BREAK-IN PERIOD:
During the fi rst few initial uses of this heater, there may be a release of a slight, harmless odor. This odor is a normal occurrence caused by the initial heating of the internal heating elements and should not reoccur.
6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
NOTE: Ensure the circuit breakers for the power supply are turned on.
This appliance can be activated using the fi re­place and heater On/Off Switch (see Figures 7 and 8) or by using the remote control when the unit power switch is already in the "ON" position.
The manual controls are located on the fi rebox fl oor on the front left (see Figure 5). If an optional glass enclosure is installed, it must be removed to access.
Fireplace and Heater On/Off
When the main power switch is turned on, power is supplied to the fi replace.
On
Off
The On/Off Switch is located on the right side of the unit below the Heater Cutoff Access Panel. In the recessed install option, this switch must be turned into the "ON" position and the appliance must
be controlled with the remote provided.
Figure 7
MAINTENANCE
This appliance has been designed to provide many years of trouble-free service. The com­ponents that will need to be serviced have been kept to a minimum. Periodic dusting of the fi replace is all that should be required.
CAUTION
Handle glass very carefully to prevent accidental breakage.
CAUTION
Disconnect power before attempt­ing any maintenance or cleaning to reduce the risk of fi re, electri­cal shock or personal injury.
WARNING
When cleaning the fi replace, the fi replace must be cool.
CLEANING THE GLASS ENCLOSURE PANEL
Over time the front glass panel may become dirty or dusty. Dust can be removed by lightly rubbing the glass surface with a clean, lint free cloth or paper towel. To remove fi ngerprints or other marks, use a damp cloth with a good quality household glass cleaner. The front glass panel should be completely dried with a clean, lint free cloth or paper towel.
CAUTION
Do not use abrasive cleaners on the glass panel. Do not spray liquids directly onto any surface of the fi replace.
OPERATION
The appliance can be turned on either by the switch located on the lower right hand side of the heater body or by supplied remote control.
Manual Operation
1. The main power ON/OFF switch in position “O,” the heater is OFF.
2. When main power ON/OFF switch is at posi­tion “I,” the heater is ready to use.
3. Press the HEAT button on the remote control repeatedly to set the heater to desired heat setting.
4. Press the Flame brightness adjustment button to adjust the fl ame height and ember bed brightness. Press and release the FLAME control button to cycle through LO, MED, HI and OFF.
SAFETY CUT-OFF
• This appliance is fi tted with a safety cut-off which will operate if the heater overheats (eg. due to blocked air vents). For safety reasons, the heater will NOT automatically reset.
• To reset the appliance, disconnect the appliance from the mains supply for at least 30 minutes. Reconnect the supply to the main switch on the appliance.
AUTO MODE
Under this mode the heater will automatically turn ON at high heat setting 1500w heat output when the room temperature drops below 72˚F (22˚ C). When the room temperature is between 72-77˚F (22-25˚ C) the heater output will switch to low heat set ting 1000W. When the room temperature goes above 77˚F (25˚ C) the heater will be turned off and the cycle will continue.
Main Power Switch in "OFF" Position.
Figure 8
900264-00 Rev. A 03/2017
WARNING
An authorized service represen­tative should perform any other servicing.
7
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
REMOTE CONTROL OPERATION:
REMOTE CONTROL
A
B
C
D
E
F
G
I
H
J
• When using the remote control, the power on/off switch on the lower right side of the
unit must be in the "ON" position.
Figure 9
REMOTE CONTROL MODEL NO. R-37 PART NO. F2052
K
CAUTIONS
• Do Not Use Old Batteries With New Ones.
• Do Not Use Batteries Other Than The Type Specifi ed (2 Ea. AA).
• Ensure Batteries Are Correctly Installed In Remote Control.
This IHP Electric Fireplace is provided with an Infrared light Remote Control. All functions of the fi replace can be controlled through the remote control. Note: The Effective range of the remote control is up to approximately 26 feet (8 meters).
The functions identifi ed on the remote (see Figure 9) are as follows:
A. POWER BUTTON
Press once to turn on power to fi replace.
B. INDICATING LIGHT
Illuminates when signal is sent.
C. FLAME BUTTON
On/off switch for fl ame and ember light.
D. AMBER FLAME BUTTON (DIM)
Reduces brightness of amber light.
E. AMBER FLAME BUTTON (BRIGHTEN)
Increases brightness of amber light.
F. HEATER ON/OFF
This button will turn the heater ON and OFF
independent of the main button.
G. TEMPERATURE ADJUSTMENT BUTTON
(HIGH)
Highest heat output, up to 75° F.
H. TEMPERATURE ADJUSTMENT BUTTON
(LOW.)
Low heat output, up to 72° F.
I. TEMPERATURE ADJUSTMENT BUTTON
(ROOM)
Sets the fi replace to Auto Mode (See Opera-
tions)
J. BLUE FLAME BUTTON (LOWER)
Reduces brightness of blue light.
K. BLUE FLAME BUTTON (HIGHER)
Increases brightness of blue light.
REMOTE CONTROL OPERATION STEPS:
1. For remote to function make sure the heater is plugged-in and main power switch located on the bottom right hand side is in the “ON” position.
2. When operating the remote make sure you point the remote to the center of the heater unit and make sure each time you press the button the LED indicator located on top right hand corner of the remote blinks. The buzzer inside the unit will beep once; if the LED fails to blink check the batteries. It takes some time for the receiver to respond to the transmitter. Do not PRESS the but­tons more than once within two seconds for correct operation.
3. Power On power button: The power-on button at top left corner of the remote is the main ON/OFF power button. This will turn off all the functions and the heater will be in standby mode.
4. Flame Power On button: This button con­trols both the amber and blue color fl ame. Press this button once to turn ON the fl ame effect. Once the fl ame effect is ON use the + and – but tons as explained below to adjust the fl ame brightness as desired. Press this button again to turn OFF the fl ame effect. The heater can function even when the fl ame effect is turned off if so desired.
The Red Flame +5 or -5 buttons control the
brightness of the Amber fame. To increase the brightness/fl ame height, press and release the fl ame +5 button. Each time you press this button the brightness will increase by a small amount, until the maximum is reached.
Press and release the Red Flame -5 button.
Each time you press this button the bright­ness will decrease by small amount, until the minimum brightness is reached.
The Blue Flame +5 or -5 buttons control the
brightness of the Blue fame. To increase the brightness/fl ame height, press and release the Blue Flame +5 button. Each time you press this button the brightness will increase by a small amount, until the maximum is reached.
To decrease the brightness / fl ame height,
press and release the Blue Flame -5 button. Each time you press this but ton the bright­ness will decrease by small amount, until the minimum brightness is reached.
Using these settings you can mix the amber and the blue fl ame to create a realistic or stylized fl ame effect. Color mixes will also be refl ected in the crystal ember bed for added impact.
5. Heater Power Button: This button is the heater ON/OFF button. Press this button to turn the heater ON. The heater will always turn on at the highest setting. In order to reduce the temperature on the heater press this button again.
High Button: Press the high button to switch the heater directly to high heat setting of 1500W.
Low Button: Press the high button to switch the heater directly to low heat setting of 750W.
Room Temp Button: Press the high but ton
to switch the heater to AUTO Mode (See
Operations, Page 7).
6. To turn OFF the heater unit com­pletely press the Power Button once.
8
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
54" LINEAR ELECTRIC FIREPLACE
47” (1194mm)
LEFT SIDE VIEW
4-3/4”
(120mm)
TOP VIEW
54” (1372mm)
FRONT VIEW
7-5/8” (194mm)
RIGHT
SIDE
VIEW
20”
(508mm)
BOTTOM VIEW
22-1/2”
(572mm)
BACK VIEW
900264-00 Rev. A 03/2017
9
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
)
4
)
(
)
)
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
60" LINEAR ELECTRIC FIREPLACE
7” (1194mm
7-5/8” (194mm
TOP VIEW
17-1/8
(436mm)
4-3/4”
121mm
LEFT SIDE
VIEW
60” (1524mm)
FRONT VIEW
BOTTOM VIEW
22-1/2” (572mm
9-5/8
(244mm)
5-1/4”
(134mm)
RIGHT
SIDE
VIEW
20”
(508mm)
BACK VIEW
MOUNTING BRACKET
25” (635mm)
>1”
2”
(51mm)
4”
(102mm)
12” (305mm)
22-1/2” (572 mm)
10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
(26mm)
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
TROUBLESHOOTING
Symptom Possible Causes
1. Fireplace does not turn on when the power button on the remote is pushed.
2. Fireplace does not turn on when main power switch is engaged.
Main power switch on the lower right side of the fi replace is in the off position.
Appliance is not plugged in or there is no power to the receptacle
3. Flame is fi xed (unmoving). Wiring may be loose or the fl ame motor may be defective.
Who Performs
Corrective Action
Corrective Action
Homeowner Turn on the main power switch.
Homeowner Plug unit in or confi rm that the circuit
breaker is switched on.
Qualifi ed service technician Inspect all wiring for loose connections.
If the wire connections are good, replace the fl ame motor.
4. Dim or poorly visible fl ame or LED
ember bed is not glowing.
LED strip failure or wiring is loose. Qualifi ed service technician Inspect all wiring for loose connec-
tions and repair or replace if neces­sary. Inspect LED strips and replace if necessary.
5. Flame sputters. Flame motor is defective. Qualifi ed service technician Replace fl ame motor.
6. Remote control does not work. Low batteries. Unit switch and/or wall switch in “on” position.
Homeowner Replace aa batteries in remote control.
If problem persists, there may have been a loss of power to the unit as a possible result from a power failure (i.E. Breaker tripped).
Turn off main power on/off switch (see fi gure 4) and/or optional wall switch (if applicable).
7. Circuit breaker trips or fuse blows
when the unit is turned on.
Improper circuit current rating. Qualifi ed service technician Check the house circuit to ensure it is
on a dedicated circuit with proper amp. Rating. If the circuit breaker continues to trip (or blown fuses), inspect wiring for a loose connection or a dead short. Repair or replace wiring and/or connec­tors as necessary.
900264-00 Rev. A 03/2017
11
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
EXPLODED DIAGRAM KEY AND AVAILABLE REPLACEMENT PARTS
ITEM
NO.
1 Front Glass F2042 F2043 1
2 Bottom Front Glass Fixed Bar N/A N/A 1
3 Top Front Glass Fixed Bar N/A N/A 1
4 Lower Baffl e N/A N/A 1
5 Ember Bed Bracket N/A N/A 1
6 Translucent LED Ember Cover N/A N/A 1
7 Mirror Glass F2044 F2044 1
8 Isolation Columns N/A N/A 1
9 Ember Bed LED Lights F2045 F2045 4
10 Flame Board N/A N/A 1
11 Drum Bracket N/A N/A 1
12 Flame Drum Assembly F2046 F2046 1
13 Plastic Handle N/A N/A 1
14 Left Side Panel N/A N/A 1
15 Left Inner Lining Board N/A N/A 1
16 Upper Bar N/A N/A 1
17 Upper Panel N/A N/A 1
18 Remote Receiver Assembly F2048 F2048 1
19 Air Outlet Bracket N/A N/A 1
20 Heater Assembly F2049 F2049 1
21 Circuit/Control Board F2050 F2050 1
22 Firebox N/A N/A 1
23 Right Lining Panel N/A N/A 1
24 Right Side Panel N/A N/A 1
25 Heater Cutoff Access Panel N/A N/A 1
26 Rocker Switch F2051 F2051 1
27 Power Supply Lines N/A N/A 1
28 Power Cord N/A N/A 1
--- Remote Control (see Page 8) F2052 F2052 1
--- Wall Mounting Bracket (see Page 10) F2053 F2053 1
--- Flame Drum Motor (Not Shown) F2047 F2047 1
--- Ember Crystals (Not Shown) F2054 F2054
DESCRIPTION
54" Models 60" Models
Cat. No. Cat. No.
QTY
2
NOTE: If touch-up paint is needed, use Rust-oleum®, Painter’s Touch, Flat Black (part number 1976) available at most stores which sell aerosol touch-up paint.
12
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
900264-00 Rev. A 03/2017
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION AND OPERATION INSTRUCTIONS
EXPLODED DIAGRAM WITH AVAILABLE REPLACEMENT PARTS - 54" AND 60" MODELS
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifi quement approuvées avec cet appareil sont utilisées.
WARNING
Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.
900264-00 Rev. A 03/2017
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
13
N
6.3*0.8
L1
N
P-NI
HS0038
GND
GND
5V 47uF
2
GND
C4
104
C6
5v
GND
2.4*7
11
P5.2
SN8P2722
P5.1
10
R12
510
12345
6
R5
10K
GND
12
P5.3
510
ELECTRICAL DIAGRAM
R3
10K
t
25*C,5K
THERMISTOR
TEMP
P5.0
SIP2
9
R11
5
P0.4
GND
104
1K
GND
C5
2.4*2
R2
104
16
P4.2/AIN2
10K
C2
1
2
R8
15
P4.1/AIN1
GND
P0.7
510
3V-4
V+
2
2.2nF/250VAC
R13
27
C9
+12V
7805IC1
+5V
D9
AC
AC
1
6.3*0.8
FUSE2
F1
PTC
2.2nF/250VAC
6.3*0.58
6.3*0.8
390PF
P-SW
S1
PH-7
TEMP_BRK
PH-6
P-L
C14
1M
LTV817A
U1B
1K
R17
FR106
R14
2M
GND
GND
L2
6mH
R16
D7
GND
35V 680uF
1KU/16V
400V 22U
TNY1
5-8
TNY278PN
+5V
C12
16V 10U
BUZ1
SS8050
T3
D1
P0.5
4007
GND
P0.6
6
R4
510
2
P0.1
8
R10
4
1
2
U1A
LTV817A
+5V
D6
12V
10
VSS
20
VDD
P0.2
7
3
400V 22U
2
6
C7
100U 16V
C8
2
GND
C1
104
R15
2M
P6KE200
EF1
D4 SB3100
3.3uH
100/0.5W
C3
D8
1
7
Vin
Vout
2KBP06M
C13
C10
C11
L1
R1
1
3
14
GND
PH-4
6.3*0.8
T6
D3
RELAY-H2
FAN MOTOR
+12V
GND
6.3*0.8
H1
8050
1N4007
H1+FAN
T5
D2
RELAY-H1
+12V
510
GND
100
LED8LED7
R9
T4
SS8050
2.4*2
2.4*2
LED6LED5
LED-M
1
2
LAMP
1
2
+12V
GND
100
LED8LED7
R6 510
SS8050
100
R?
LED6LED5
LED-HB
2.4*2
1
2
2.4*2
FIRE-Y
1
2
+12V
T2
GND
R?
180
LED2
LED3
R7
510
T1
SS8050
2.4*2
2.4*2
R?
180
DS?
LED1D1
DS?
LED-HY
1
2
FIRE-B
1
2
+12V
180
R?
8050
+12V
1N4007
D5
RELAY-MOTOR
MOTOR
6.3*0.8
MOTOR
6.3*0.8
8050
1N4007
H2 PH-2
H2
GND
T7
Innovative Hearth Products
Electric Fireplace
Limited One Year Warranty
THE WARRANTY
Innovative Hearth Products Limited One Year Warranty ("IHP") warrants your electric fi replace, appliance or insert ("Product") to be free from defects in materials and work­manship at the time of manufacture. The product body, blower and circuit board, if applicable, carry the Limited One Year Warranty. After installation, if covered components are found to be defective in materials or workmanship during the Limited One Year Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP Product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited One Year Warranty as described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from IHP, regardless of the installation or occupancy date.
EXCLUSIONS AND LIMITATIONS
This Limited One Year Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be provided. The following do not carry a Limited One Year Warranty but are warranted as follows:
Glass components – Replacement for 90 days from the date of installation Accessories & doors – Repair or replacement for 90 days from the date of installation Light bulbs, LED strips & batteries – Replacement for 90 days from the date of installation for defects in material and workmanship only Remote control – Repair or replacement for one year from the date of installation Labor coverage – Prevailing IHP labor charges apply for the warranty period of the component
Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. All precautions and warnings as described in the instruction/owner’s manual must be followed.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instruc­tions provided with the Product; (d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.
This Limited One Year Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.
LIMITATION ON LIABILITY
It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Products, whether such damage occurs or is discovered before or after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited One Year Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited One Year Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited One Year Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
IHP reserves the right to investigate any and all claims against this Limited One Year Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefi ts and advantages described in this Limited One Year Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a
contractor that is not approved without fi rst obtaining IHP's prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.IHP.US.COM.
Printed in U.S.A. © 2013 Innovative Hearth Products LLC
P/N 900220-00, Rev. A 10/2015
Innovative Hearth Products 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
15
INNOVATIVE HEARTH PRODUCTS • LINEAR ELECTRIC FIREPLACE • INSTALLATION INSTRUCTIONS
IHP.us.com
Record the following important information about your appliance:
Appliance model number
Appliance serial number
Date appliance was Installed
Dealer name
16
IHP reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information.
Printed in U.S.A. © 2014 Innovative Hearth Products
P/N 900264-00 Rev. A 03/2017
P900264-00
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
Loading...