Thank you for choosing our product.
This product is a high-tech infra-red (IR) thermometer
designed to take human body temperature by measuring the
1
1
1
2
3
4
4
4
6
6
7
7
7
8
8
8
8
9
9
11
energy of IR emitted from the forehead. The product helps
you to assess you and your family members’ health
conditions easily and quickly.
Product Name: Infrared No-Touch Forehead Thermometer
Product Model: PT3
Safety Precautions
Warning
Use of this thermometer is not intended as a substitute for
consultation with your physician. Please consult your doctor
if you have any doubt about the temperature reading.
For consumer use only, not for professional use.
Keep the thermometer out of reach of children. For
accidental swallowing of the battery or other components,
please contact emergency services immediately.
Batteries must not be thrown into an open re or short
circuited.
Caution
(1) Measurements
1. Thermometer readings should be regarded as a reference.
Do not attempt self-diagnostics or self-treatment using the
temperature readings. Please seek professional medical
advice when necessary.
2. There is no absolute standard for human body
temperature. Knowing your own normal body temperature
range is important to accurately determine if you have a
fever.
3. Make sure that the forehead of the subject is free from
sweat, cosmetics, dirt, or grease before measuring.
4. Patients should not drink, eat, or be physically active
before/while taking a reading. Wait 30 minutes before
taking a measurement. Temperature readings taken when
a body is in a state of stable equilibrium is more accurate
and useful as a reference.
5. Do not take temperature measurement over scar tissue,
open sores or abrasions.
6. Do not measure body temperature from scar tissues on the
forehead as such tissues will aect temperature conduction
of the body.
7. If there is a temperature dierence between the
thermometer storage area and the new ambient
environment around the subject, please let the
thermometer sit within the new environment for 30
minutes before taking the measurement.
8. Do not measure body temperature immediately after
consuming a drug that raises body temperature.
Temperature readings taken at this time will not be
accurate.
9. It is normal for readings taken from continuous
measurements to uctuate within a small range. During
continuous measurements, the subject’s body temperature
may be transmitted to the thermometer, aecting
1
measurement accuracy. We recommend taking only up to
3 continuous readings within a short period.
10. Do not directly face the sun or an air outlet of an air
conditioning or radiator device during the measurement
as this will cause changes to the forehead temperature.
Measurements should be taken in a stable environment
where possible.
11. Do not measure body temperature in an environment
with strong EM interference (examples include places
close to a working microwave, induction cooker, or
cellphone in-use) as EM interference may cause errors in
the reading or even device failure.
12. This product should be considered a personal device.
Clean and sanitize the product properly to prevent cross
contamination.
13. To clean a dirty thermometer probe, gently swipe the
probe using a cotton swab dipped in 75% alcohol. Let the
cleaned thermometer sit for at least 15 minutes before
taking more measurements.
14. This infrared thermometer meets requirements
established in ASTM Standard (E1965-98) Except of clause
5.2.2. It displays subject’s temperature over a range of 89.6
℉~109.2℉. Full responsibility for the conformance of this
product to the standard is assumed by (manufacturer:
Famidoc Technology Co., Ltd. Add:
No. 212 Yilong Road, Hexi Industrial Zone, Jinxia, Changan
Town, Dongguan 523853, Guangdong Province, China.)
(2) About the product
1. This product is a precision device. Return the product to its
original packaging for proper storage after use. To ensure
accurate measurements, avoid the device or probe
contacting any liquid or droplets. Avoid tiny particles (such
as dust or powder) falling into the probe.
2. Avoid dropping or subjecting the product to external
forces. Do not disassemble or re-assemble the product on
your own.
3. Do not directly touch the probe with your ngers or blow
on it. Measurements taken using a damaged or dirty IR
probe may be inaccurate.
4. Keep the product at a place inaccessible to children to
prevent children from swallowing the batteries or small
parts.
5. Do not throw the thermometer or batteries into re to
prevent explosions.
6. Remove the batteries from the thermometer if the device
will not be used for more than one month.
7.If you are allergic to plastic/rubber, please don’t use this
device.
8.The materials (ABS, TPU, metal) of expect contact with
patient had passed the ISO 10993-5 and ISO 10993-10
standards test, no toxicity, allergy and irritation reaction.
They are in compliance with the MDD requirements.
Based on the current science and technology, other
potential allergic reactions are unknown.
Overall Description
The thermometer is mainly comprised of a plastic casing, IR
23
temperature sensor, MCU, vibration motor, LED display screen
and batteries.
Thermometer
LED display
area
Measurement
button
probe
Distance
probe
Battery cover
LED screen instructions
Temperature
display area
Low power
reminder
Device dimensions: 5.39 in x 1.34 in x 1.54 in
Screen dimensions: 1.01 in x 0.75 in
Product weight: 90 g
Celsius
Fahrenheit
Product performance
1. Measurement position: Centre of the forehead surface
2. Measurement distance: ≤1.18in(3 cm)
3. Power source: DC 3V; 2 x 1.5V AAA batteries
4. Measurement range: 89.6℉-109.2℉(32℃-42.9℃)
5. Measurement precision: ±0.4℉ within 95℉-107.6℉,
and±0.5℉ for other temperature ranges.
9. Operation mode:
Adjusted mode: forehead
Direct mode: surface mode
10. Expected service life: 2 years
11. Reference Body Site: Oral
12. Software version: V1.0
ASTM laboratory accuracy requirements in the display range
of 98°F to 102°F(37℃) for IR thermometers is ±0.4°F(±0.2℃),
whereas for mercury in-glass and electronic thermometers,
the requirement per ASTM Standards E667-86 and E1112-86
is ±0.2°F(±0.1℃).
Expected use and scope of applications
This product mainly uses IR temperature sensing of the
forehead to measure human body temperature. Can be used
for babies, children, and adults. Babies and children should
not operate the thermometer on their own. Body temperature
readings for babies and children should be taken by an adult.
Reminder: Temperature readings may dier according to skin
tone and measurement distance.
Contraindications
It is not recommended for people whose measuring part has
local lesions, such as inammation, trauma, postoperative,
etc.
Instruction For Use
The patient is an intended operator. The patient can measure,
transmit data and change battery.
(1) Installing the product
Insert the 2 battery cells from the packaging box into the
battery compartment at the back of the device. The product
will start automatic inspection and a standby mode (if the
device indicates low battery power, then replace the
batteries to ensure ample power supply).
(2) Measurement process
Aim the thermometer probe at the center of the
1
forehead and keep the probe 1.18in (3cm) away from
the forehead (the optimal distance is about the width of
an adult’s index nger). Do not touch the forehead with
the probe.
≤1.18in(3cm)
Gently press the
2
measurement button
[ ] to start the
measurement.
The device will vibrate
3
once a reading is obtained.
The reading will be
displayed on the screen. If
the measurement is failed,
the device will not vibrate
the screen but display
[ ] instead.
45
Possible reasons for measurement errors include:
A. Measurement distance is greater than
1.18in (3cm);
B. Environment temperature does not
meet measurement requirements or
there is an excessively large
temperature dierence;
C. Target temperature exceeds
measurement range.
(3) Power o
If no more measuring is required, simply let the device sit idle
for 8 seconds to power o automatically.
(4) Unit switching
1. When the device is powered OFF, press and hold the
measurement button for 8 seconds to enter unit switching
mode. Under this mode, both ℃ and °F should ash at the
same time.
2. Under this mode, press the measurement button to switch
to Fahrenheit or Celsius. The corresponding symbol of the
selected unit after switching will ash.
3. After selecting the unit, press and hold the measurement
button for 8 seconds to leave the unit switching mode.
Reminder: If you do not press and hold the measurement
button for 8 seconds to conrm the unit selected before the
screen switches o, the system will consider the switch as a
failure and retain the original unit for temperature
measurements.
(5) Installing and replacing batteries
When switched ON for use, the thermometer will
automatically detect remaining battery capacity. If battery
capacity is low but adequate for measurements, the low
power symbol [ ] will be displayed with the measurement
results. However, if the battery capacity is too low for
measurements, the screen will display a single, ashing [ ]
icon and automatically switch OFF after 8 seconds. To
continue using the device, old batteries must be replaced.
(6) Replacing batteries
1. Press down and hold the battery cover with the nger and
apply some force to slide the cover backwards to open the
battery compartment.
2. Remove the old batteries and install the new batteries.
3. Refer to the battery polarity symbols to orient the batteries
properly during installation. Make sure that the new
batteries are tightly inserted into the battery compartment
and make sure that the polarity is not reversed during
installation.
4. Return the battery cover to close the battery compartment.
Comply with relevant national laws and regulations when
disposing of the used batteries.
Do not dispose of batteries directly into the trash bag.
Remove the batteries if the device will not be used more
than one month.
When using, shall not touch battery and the patient
simultaneously.
Do not throw batteries into re.
The typical service life of the new and unused batteries is
300 measurements for the operation time is 60s.
Product errors and troubleshooting
Item to detectSolutionProblem
Replace old
Battery depleted
·
· Batteries have been
installed with the
wrong polarity
· Batteries are not
installed properly
Unable to carry out
·
measurement as
current battery
capacity is too low.
· Measurement
distance too long
Target temperature is
·
beyond range of
measurements 89.6℉-
109.2℉(32℃-42.9℃)
·
Environment temperature
either exceeds the design
range 59℉-104℉(15℃40℃) or is unstable
·
Current state: All
symbols are ashing
on the screen. The
product is not usable.
·
Current battery
capacity is too low.
batteries with
new ones
Take out the
batteries and
re-install them
correctly.
Replace the
batteries
Follow the
instruction
manual and
repeat the
measurements
Please contact
customer
services.
Replace the
battery as soon
as possible.
Body temperature
Body temperature varies from person to person and
uctuates during the course of the day. For this reason, it is
suggested to know one's normal, healthy forehead
temperature to correctly determine the temperature.
Body temperature runs approximately from 95.9°F to100°F
(35.5℃-37.8℃). To determine if one has a fever, compare the
temperature detected with the person's normal temperature.
A rise over the reference body temperature of 1°F(1℃) or
more is generally an indication of fever.
Dierent measurement sites(rectal, axillary, oral, frontal,
auricular) will give dierent readings. Therefore it is wrong to
compare the measurement taken from dierent sites.
67
The following aretypical temperatures for adults, based
on dierent measurement sites:
Rectal
Axillary
Oral
Auricular
97.9°F-99.1°F
94.5°F-99.1°F
95.9°F-99.5°F
96.4°F-100.4°F
36.6℃ to 38℃
34.7℃ to 37.3℃
35.5℃ to 37.5℃
35.8℃ to 38℃
Care and Cleaning
1. The probe (comprising a temperature sensor and a distance
sensor) is the most intricate part of the thermometer, and
should be kept clean and intact to acquire accurate
readings.
Use the following method to clean the probe:
Gently swab the surface of the probe using a cotton bud
soaked in > 75% medical alcohol.
2. If the probe (sensor) is broken, please contact customer
services.
3. Use a piece of soft, dry cloth to clean the display screen and
external surface of the thermometer. If the thermometer is
very dirty, the cloth can be moistened with some medical
alcohol to clean the device.
4. The product is not waterproof. Do not clean the device with
detergents. Do not soak the thermometer in water or other
liquids.
Maintenance
1. This company has not authorized any agency or individual
to carry out product repairs or maintenance. Do not
attempt to disassemble or modify the thermometer if you
suspect functional issues with the device.
2. The IR thermometer is an extremely precise instrument. Any
improper maintenance, disassembly, or modication may
lead to inaccuracies of the product measurements.
3. If you suspect any product issues during the warranty
period, please contact customer services for subsequent
handling.
Disposal
Dispose of the battery in accordance with the
regulation applicable at the place of operation.
Dispose of at public collection point in the EU
countries – 2002/96/EC WEEE Directive.
If you have any queries, please refer to the local
authorities responsible for waste disposal.
Notes
• Please act according to local laws for disposal of used
batteries.
• Take out the battery if you are not going to use the unit for
a long time.
To protect the environment, dispose of empty
batteries at appropriate collection sites according to
national or local regulations.
Dispose of at public collection point in the EU
countries – 2006/66/EC Directive.
Operating, shipping, and storage conditions
(1) Operating conditions
Range of operating environments
Temperature: 59℉-104℉(15℃- 40℃)
Humidity: 15-85%RH,non-condensing
Atmospheric Pressure: 70kPa~106kPa
(2) Transportation / storage conditions
Main Unit: -4℉~131℉(-20℃~ 55℃)
Humidity: 15-95%RH, non-condensing
Atmospheric Pressure: 70kPa~106kPa
Accessories
Use only accessories provided by the original manufacturer,
and check for any missing accessories.
1 IR Thermometer
1 Instruction manual
2 AAA batteries
1 Quick user guide
Standard icons
Attention: Follow instructions for use!
(The sign background color: blue. The sign
graphical symbol: white.)
The batteries and electronic instruments must
be disposed of in accordance
with the locally applicable regulation, not with
domestic waste.
Manufacturer information
Symbol for "WARNING"
Serial number
Authorized representative in the European
Community
IP code of the device: this device’s grade of
against ingress of solid foreign objects -- ≥
12.5mm diameter (and the against access to
hazardous parts with nger); the grade of
waterproof is dripping (15° tilted).
Complies with MDD 93/42/eec Requirements
0120
Calibration
The thermometer is initially calibrated at the time of
manufacture. If this thermometer is used according to the
use instruction, periodic re-adjustment is not required. If any
time your question the accuracy of measurement, please
contact distributor or manufacturer, the contact information
is on the last page.
8
Storage
1) Do not put the thermometer under direct
sunlight, high temperature, or moist
environments. Do not allow it to come into
contact with re or harsh vibrations.
2) Take out the battery if the device is not used for
a long period of time.
Electromagnetic Compatibility (EMC) Tables
Guidance and manufacturer’s declaration -
electromagnetic emissions
The PT3 device is intended for use in the electromagnetic
environment specied below.The customer or the user of the
PT3 should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR11
RF emissions
CISPR11
Harmonic
emissions
lEC61000-3-2
Voltage
uctuations/
ickeremissions
lEC61000-3-3
environment specied below.The customer or the user of the
Immunity test IEC 60601 Test
Electrostatic
discharge(ESD)
lEC61000-4-2
environment specied below. The customer or the user of the
Compliance
Group 2The PT3 device must emit
Class B
Not applicable
Not applicable
Guidance and manufacturer’s declaration —
electromagnetic immunity
The PT3 device is intended for use in the electromagnetic
PT3 should assure that it is used in such an environment.
level
±6kV contact
±8kV air
Guidance and - manufacturer’s declaration.
Electromagnetic immunity
The PT3 device is intended for use in the electromagnetic
PT3 should assure that it is used in such an environment.
Electromagnetic environment
-guidance
electromagnetic energy in
order to perform its intended
function. Nearby electronic
equipment maybe aected.
The PT3 device is suitable for
use in all establishments
other than domestic and
those directly connected to
the public low-voltage
power supply network that
supplies buildings used for
domestic
purposes.
Compliance
level
±6kV contact
±8kV air
Electromagnetic
environment guidance
Floors should be
wood , concrete or
ceramic tile.
If oors are
covered with
synthetic material,
the relative
humidity should
be at least 30%.