Quick Start Guide
Cloud-Enabled Indoor Access Point
Spark™ AC Wave2 Mini, SP-W2M-AC1200
1. Unpack the AP
◆
Spark AC Wave2 Mini, SP-W2M-AC1200
◆
Universal AC/DC power adapter
◆
USB cable — Micro to Type A
◆
Cat 5e Ethernet cable, 1.2 m (4 ft)
◆
2 Med Command strips
◆
Quick Start Guide (this document)
2. Mount the AP
a. Mounting the AP on a Wall
At the installation location on the wall, mark two holes
44 mm (1.73 in) apart for the wall plugs and screws (not
included).
Drill two holes for the wall plugs, and then insert the plugs
and tap them flush with the wall surface.
Insert the two screws in the wall plugs leaving the screw
heads about 5 mm from the wall surface.
With its ports facing down, place the AP’s mounting points
over the two screws, and then slide it down on the screws.
Do not let go of the AP until you confirm that it is secure.
b. Alternative Wall-Mounting Method
c. Mounting the AP on a Desktop
Attach the included four rubber feet to the base of the AP.
Place the AP on the desktop.
3. Connect Cables
Connect the cable from the AC/DC power adapter to the USB
power jack on the AP.
Connect the power adapter to a nearby AC power source
(100-240 VAC, 50/60 Hz).
Connect Category 5e or better cable to the 1000BASE-T
Eth1 RJ-45 port.
Connect the other end of this cable to a LAN switch.
(Optional) Connect a local LAN device to the Eth2 RJ-45 port
on the AP using Category 5e or better cable.
This Eth2 RJ-45 port is a 100BASE-TX port.
ignitenet.com
Position and stick the two supplied Med Command strips to
the base of the AP as shown.
Position the AP on the wall and press firmly for 30 seconds.
Remove the AP from the wall to separate the strips. Wait a
further hour before mounting the AP.
Mount the AP by pressing the strips together until they click.
4. Verify AP Operation
The power LED should be on green.
– 1 –
Spark SP-W2M-AC1200
E122017-CS 150200001xxxX R01
During normal operation, the wireless LEDs should be on/
Log in to the web interface
using the default settings:
◆
Login Name — root
◆
Password — admin123
Select the country of
operation for the AP. Setting
the correct country ensures
that the radios operate within
local regulations specified for
Wi-Fi networks.
blinking green.
The Ethernet port link/activity LEDs should be on/blinking
green.
5. Connect to the Web User Interface
To access the web interface, connect a PC directly to the AP’s Eth2
RJ-45 port. In a web browser, enter the AP’s default management IP
address of 192.168.2.1 to access the web login page.
If you want to connect to the web interface using the Eth1 port, the
IP address is automatically assigned through DHCP by default. If a
DHCP server is unreachable, the Eth1 port reverts to a fallback IP
address of 192.168.1.20.
Note:
To reset the AP to factory default settings, press and
hold down the AP’s Reset button for 5 seconds.
6. Complete the Setup Wizard
Quick Start Guide
Safety and Regulatory Information
FCC Class B
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following
measures:
◆ Reorient or relocate the receiving antenna
◆ Increase the separation between the equipment and receiver
◆ Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected
◆ Consult the dealer or an experienced radio/TV technician for help
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user’s authority to
operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Manage the AP with the IgniteNet Cloud Controller
Go to cloud.ignitenet.com to register your AP.
Log in and select Devices from the menu. Click Add Device and
enter the AP serial number and MAC address to register the AP with
your cloud network. The serial number and MAC address can be
found on the product packaging or label.
Manage the AP in Stand-Alone Mode
If you select to manage the AP in stand-alone mode, use the web
interface to manually make your configuration changes.
For more information on AP configuration in stand-alone mode,
refer to the HeliOS User Manual, which can be downloaded from
ignitenet.com/support.
For product available in the USA/Canada market, only channel 1–11 can
be operated. Selection of other channels is not possible.
Operation within the 5.15–5.25GHz frequency range is restricted to an
indoor environment.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20 cm between the radiator and your
body.
Industry Canada
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation
of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement.
For product available in the USA/Canada market, only channel 1~11 can
be operated. Selection of other channels is not possible.
– 2 –