At the installation location on the wall, use the wall/ceilingmount bracket to mark four holes for the wall plugs and
screws (included in wall-mount kit).
Drill four holes for the wall plugs, and then insert the plugs
and tap them flush with the wall surface.
Use the four screws to secure the bracket to the wall.
With its ports facing down, slide the AP down onto the
bracket until it snaps into its secured position.
Do not let go of the AP until you confirm that it is secure.
c. Mounting the AP on a Pole (requires optional pole-mount kit)
Attach the pole-mount bracket to the back of the AP.
Use the included screw to secure the bracket to the AP.
Feed the two steel-band clamps through the pole-mount
bracket mounting points.
Fasten the steel-band clamps around the pole to secure the
AP to the pole.
3. Connect Cables
a. Using the AC/DC Power Adapter
b. Mounting the AP on a Ceiling
Slide the wall/ceiling-mount bracket onto the rails on the
back of the AP until it snaps into its secured position.
Use the included screw to secure the bracket to the AP.
Press the retention clips of the wall/ceiling-mount bracket
against the ceiling T-bar.
The wall/ceiling-mount bracket supports two
ignitenet.com
Rotate the AP until the T-bar snaps into place.
Note:
different sizes of suspended ceiling T-bars. The position
illustrated above is for 15 mm bars. Use the position at a 90
degrees angle for 24.5 mm bars.
Connect the cable from the AC/DC power adapter to the DC
power jack on the AP.
Connect the power adapter to a nearby AC power source
(100-240 VAC, 50/60 Hz).
Connect Category 5e or better cable to the Eth0 RJ-45 port.
Connect the other end of this cable to a LAN switch.
(Optional) Connect local LAN devices to the other RJ-45 port
on the AP using Category 5e or better cable.
This 1000BASE-T port is labeled Eth1.
– 1 –
E092017-CS 150200001744X R01
Spark SP-W2-AC1200
Quick Start Guide
1
2
1
2
1
2
3
1
2
3
Log in to the web interface
using the default settings:
◆
Login Name — root
◆
Password — admin123
Select the country of
operation for the AP. Setting
the correct country ensures
that the radios operate within
local regulations specified for
Wi-Fi networks.
b. Using a PoE Power Source
Connect Category 5e or better cable to the Eth0 PoE In
RJ-45 port, and the other end of this cable to an 802.3af PoE
LAN switch.
(Optional) Connect local LAN devices to the other
Eth1 RJ-45 port on the AP using Category 5e or better cable.
4. Verify AP Operation
5. Connect to the Web User Interface
To access the web interface, connect a PC directly to the AP’s Eth1
RJ-45 port. In a web browser, enter the AP’s default management IP
address of 192.168.2.1 to access the web login page.
If you want to connect to the web interface using the Eth0 port, the
IP address is automatically assigned through DHCP by default. If a
DHCP server is unreachable, the Eth0 port reverts to a fallback IP
address of 192.168.1.20.
Note:
To reset the AP to factory default settings, press and
hold down the AP’s Reset button for 5 seconds.
6. Complete the Setup Wizard
Manage the AP with the IgniteNet Cloud Controller
Go to cloud.ignitenet.com to register your AP.
Log in and select Devices from the menu. Click Add Device and
The power LED should be on amber.
The Eth0 port link/activity LED should be on/blinking green.
When connected, the Eth1 port link/activity LEDs should
also be on/blinking green.
During normal operation, the wireless LEDs should be on/
blinking green.
enter the AP serial number and MAC address to register the AP with
your cloud network. The serial number and MAC address can be
found on the product packaging or label.
Manage the AP in Stand-Alone Mode
If you select to manage the AP in stand-alone mode, use the web
interface to manually make your configuration changes.
For more information on AP configuration in stand-alone mode,
refer to the HeliOS User Manual, which can be downloaded from
ignitenet.com/support.
– 2 –
Safety and Regulatory Information
FCC Class B
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following
measures:
◆Reorient or relocate the receiving antenna
◆Increase the separation between the equipment and receiver
◆Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected
◆Consult the dealer or an experienced radio/TV technician for help
Quick Start Guide
Dynamic Frequency Selection (DFS) for devices operating in the bands
5250- 5350 MHz, 5470-5600 MHz and 5650-5725 MHz.
Sélection dynamique de fréquences (DFS) pour les dispositifs
fonctionnant dans les bandes 5250-5350 MHz, 5470-5600 MHz et 56505725 MHz.
The device for operation in the band 5150-5250 MHz is only for indoor
use to reduce the potential for harmful interference to co-channel
mobile satellite systems.
les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés
uniquement pour une utilisation à l'intérieur afin de réduire les risques
de brouillage préjudiciable aux systèmes de satellites mobiles utilisant
les mêmes canaux.
IMPORTANT NOTE:
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set
forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20 cm between the
radiator and your body.
Cet équipement est conforme aux limites d'exposition aux
rayonnements IC établies pour un environnement non contrôlé. Cet
équipement doit être installé et utilisé avec un minimum de 20 cm de
distance entre la source de rayonnement et votre corps.
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user’s authority to
operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
For product available in the USA/Canada market, only channel 1–11 can
be operated. Selection of other channels is not possible.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20 cm between the radiator and your
body.
Industry Canada
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation
of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement.
For product available in the USA/Canada market, only channel 1~11 can
be operated. Selection of other channels is not possible.
Pour les produits disponibles aux États-Unis / Canada du marché, seul le
canal 1 à 11 peuvent être exploités. Sélection d'autres canaux n'est pas
possible.
CE Statement
This equipment complies with EU radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20 cm between the radiator and your
body.
The device is restricted to indoor use only when operating in the 5150 to
5350 MHz frequency range.
The frequency and maximum transmitted power limit in EU are listed as
below:
2412-2472 MHz: 20 dBm
5150-5350 MHz: 23 dBm
5500-5700 MHz: 30 dBm
ATBEBGCHCYCZ
DEDKEEELESFI
FRHRHUIEISIT
LILTLULVMTNL
NOPLPTROSESI
SKTRUK
The abbreviations of the countries, as prescribed in above table, where
any restrictions on putting into service or any requirements for
authorization of use exist.
– 3 –
Hardware Specifications
Quick Start Guide
Europe - EU Declaration of Conformity
Hereby, IgniteNet Inc. declares that the radio equipment type: Spark™
AC Wave2, SP-W2-AC1200 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address:
www.ignitenet.com -> support.