Welcome to MetroLinq
Interference-Free Gigabit Wireless
Unboxing
After opening the box, you will find…
MetroLinq (ML2.5-60-35 or ML2.5-60-19)
Bracket Kit
POE Power Supply
Power Cable
Tools/Items Required
13 mm Socket Wrench
Flat-Head Screwdriver
Ethernet Cables
(Optional) Alignment Scope ICC-SCOPE-9x50
For helpful training and user-case information, please go to ignitenet.com/support
Assembly
The MetroLinq bracket is designed for wall and pole mounting
5 mm - 75 mm pole diameter). Choose what is best for your
(2 location and select hardware accordingly.
Install the bracket onto MetroLinq using four M8 bolts, lock washers, and flat washers.
Power Up
Connect an Ethernet cable from the MetroLinq WAN port (right-side RJ-45) to the POE port on the power supply.
Ensure all four position-locking bolts are tight before installing.
www.ignitenet.com
– 1 –
Connect Ethernet cable from the “LAN” port on the power supply to your LAN device.
Connect the power cord to a nearby AC power source.
MetroLinq 60
E042016-CS 15020000xxxxA R01
Quick Start Guide
2
1
4
A
2
3
B
1
2
345
1
2
Alignment
IgniteNet strongly recommends using the ICC-SCOPE-9x50 Alignment Scope for alignment. To install, place the scope on top of the MetroLinq housing and secure it with its thumb screw.
Software
To configure your MetroLinq, connect your computer to the LAN port on the device and configure the IP subnet to match the default IP address of 192.168.1.20 Once configured, direct your web browser to 192.168.1.20 and log in.
username: root password: admin123
Note:
Do not adjust bolts A and B without first loosening 1
and 4 respectively. Loosen coarse adjustment bolts 2 and 3 and set initial
alignment. Don’tworry, you don’t have to be too accurate yet. After you have set the coarse alignment, tighten bolts 2 and 3.
Loosen the horizontal fine-tune adjustment bolt 4. Use fine­tune bolt "B" to optimize the horizontal position. Re-tighten bolt 4.
Loosen the vertical fine-tune adjustment bolt 1. Use fine­tune bolt "A" to optimize the vertical position. Re-tighten bolt 1.
Initial alignment should be based on optical or visual alignment. After you achieve this, repeat steps 2 and 3 while watching the 60 GHz signal strength LED. Optimize position to the LED indicator.
Ensure all bolts are fully tightened, remove the alignment scope (if installed), and enjoy Gigabit interference-free wireless.
After you have logged in, follow the steps in the Setup Wizard to configure the device for your network.
For more configuration details and training, please go to ignitenet.com/support
– 2 –
Safety and Regulatory Information
FCC Class B
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Operation within the 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range is restricted to an indoor environment. The 5600-5650MHz band is disabled by software during manufacturing and cannot be changed by the end user. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 48 cm between the radiator and your body.
Note: The country code selection is for non-US models only and is not available on all US models. Per FCC regulation, all Wi-Fi products marketed in the US must be fixed to US operation channels only.
Quick Start Guide
Instructions d'installation professionnelle
1. Installation
Ce produit est destiné à un usage spécifique et doit être installé par un personnel qualifié maîtrisant les radio-fréquences et les règles s'y rapportant. L'installation et les réglages ne doivent pas être modifiés par l'utilisateur final.
2. Emplacement d'installation
En usage normal, afin de respecter les exigences réglementaires concernant l'exposition aux radio-fréquences, ce produit doit être installé de façon à respecter une distance de 69 cm entre l'antenne émettrice et les personnes.
3. Antenne externe
Utiliser uniquement les antennes approuvées par le fabricant. L'utilisation d'autres antennes peut conduire à un niveau de rayonnement essentiel ou non essentiel dépassant les niveaux limites définis par FCC/IC, ce qui est interdit.
4. Procedure d'installation
Consulter le manuel d'utilisation.
5. Avertissement
Choisir avec soin la position d'installation et s'assurer que la puissance de sortie ne depasse pas les limites en vigueur. La violation de cette règle peut conduire à de sérieuses pénalites fédérales.
CE Mark
CE Mark Declaration of Conformance for EMI and Safety (EEC)
This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
National Restrictions
This device is intended for home and office use in all EU countries (and other countries following the EU directive 1999/5/EC) without any limitation except for the countries mentioned below:
Country Restriction Reason/Remark
Bulgaria None General authorization required for
France Outdoor use limited
to 10 mW e.i.r.p. within the band 2454-2483.5 MHz
italy None If used outside of own premises,
outdoor use and public service
Military Radiolocation use. Refarming of the 2.4 GHz band has been ongoing in recent years to allow current relaxed regulation. Full implementation planned 2012
general authorization is required
– 3 –