
Welcome to MetroLinq
TM
Interference-Free Gigabit Wireless
ignitenet.com

Unboxing
After opening the box, you will find…
• MetroLinq
TM
• Bracket Kit
• POE Power Supply
• Power Cable
Tools/Items Required
• 13 mm Socket Wrench
• Flat-Head Screwdriver
• Ethernet Cables
• (Optional) Alignment Scope ICC-SCOPE-9x50
ignitenet.com2
For helpful training and user-case information, please go to ignitenet.com/support

ignitenet.com3
Assembly
The MetroLinq™ bracket is designed for
wall and pole mounting (25mm - 75mm
pole diameter). Choose what is best for
your location and select hardware
accordingly.
1. Ensure all four position-locking bolts are
tight before installing.
2. Install the bracket onto MetroLinq™
using four M8 bolts, lock washers, and
flat washers.

Power Up
1. Connect an Ethernet cable from the
MetroLinq™ WAN port (right-side
RJ-45) to the POE port on the power
supply.
2. Connect Ethernet cable from the
“LAN” port on the power supply
to your LAN device.
3. Connect the power cord to a nearby
AC power source.
ignitenet.com4

Alignment
IgniteNet strongly recommends using the ICC-SCOPE-9x50
Alignment Scope for alignment. To install, place the scope
on top of the MetroLinq™ housing and secure it with its
thumb screw.
ignitenet.com5
Note: Do not adjust bolts A
and B without first loosening
1 and 4 respectively.
!
1. Loosen coarse adjustment bolts 2 and 3 and set initial alignment. Don’tworry,
you don’t have to be too accurate yet. After you have set the coarse
alignment, tighten bolts 2 and 3.
2. Loosen the horizontal fine-tune adjustment bolt 4. Use fine-tune bolt "B" to
optimize the horizontal position. Re-tighten bolt 4.
3. Loosen the vertical fine-tune adjustment bolt 1. Use fine-tune bolt "A" to
optimize the vertical position. Re-tighten bolt 1.
4. Initial alignment should be based on optical or visual alignment. After you
achieve this, repeat steps 2 and 3 while watching the 60 GHz ignal strength
LED. Optimize position to the LED indicator.
5. Ensure all bolts are fully tightened, remove the alignment scope (if installed),
and enjoy Gigabit interference-free wireless.
B
1 4
A
2 3

ignitenet.com6
Software
1. To configure your MetroLinq, connect your computer to the LAN port on the
device and configure the IP subnet to match the default IP address of
192.168.1.20 Once configured, direct your web browser to 192.168.1.20 and
log in.
username: root
password: admin123
2. After you have logged in, follow the steps in the Setup Wizard to configure the
device for your network.
For more configuration details and training,
please go to ignitenet.com/support
150200001244A R01