Ensure the rack on which the switch is to be mounted is
properly grounded and in compliance with ETSI ETS 300 253.
Verify that there is a good electrical connection to the
grounding point on the rack (no paint or isolating surface
treatment).
Attach the included grounding wire to the grounding point
on the switch rear panel, and then to rack ground.
Caution:
unless all supply connections have been disconnected.
Caution:
location. It should have a separate protective earthing
terminal on the chassis that must be permanently
connected to earth to adequately ground the chassis and
protect the operator from electrical hazards.
The earth connection must not be removed
The device must be installed in a restricted-access
Attach the brackets to the front of the switch.
Use the screws and cage nuts supplied with the rack to
secure the switch in the rack.
Caution:
people. One person should position the switch in the rack,
while the other person secures it using the rack screws.
Note:
using the included adhesive rubber foot pads.
Installing the switch in a rack requires two
The switch can also be installed on a desktop or shelf
4. Connect Power
Plug the AC power cord into the socket on the rear of the
switch.
Connect the other end of the power cord to an AC power
source. Verify that the external AC power requirements for
the switch are AC 100-240 V, 50-60 Hz, 2.1 A
Warning:
not touch!
Note:
AC line cord. You must use a line cord set that has been
approved for the socket type in your country.
The bottom of the enclosure is a hot surface. Do
For International use, you may need to change the
www.ignitenet.com
– 1 –
E122016-CS-R01
150200001593A
Quick Start Guide
1
1
Log in to the web interface
using the default settings:
◆
Username — admin
◆
Password — admin
2
1
3
1
2
3
2
3
1
123
5. Verify Switch Operation
Verify basic switch operation by checking the system LEDs.
When operating normally, the Power and Diag LEDs should
be on green.
6. Connect to the Web User Interface
To access the web interface, connect a PC directly to a switch RJ-45
port. Set the PC’s IP address to be on the same subnet as the switch
(that is, the PC and switch addresses must both start 192.168.2.x
with subnet mask 255.255.255.0). In a web browser, enter the
switch’s default management IP address of 192.168.2.10 to access
the web login page.
Alternatively, you can connect to the switch console port and use
the command-line interface (CLI) to assign an IP address to the
switch’s default VLAN (see following section “Setting an IP Address
Using the CLI”).
Log in to the CLI using default settings: Username “admin”
and password “admin.” Enter the following CLI commands
to set an IP address for VLAN 1.
For RJ-45 ports, connect 100-ohm Category 5, 5e or better
twisted-pair cable.
For the SFP slots, first install SFP transceivers and then
connect fiber optic cabling to the transceiver ports.
The following transceivers are supported:
◆
1000BASE-SX
◆
1000BASE-LX
◆
1000BASE-ZX
◆
1000BASE-LHX
Note:
For further information on switch configuration, refer
to the Web Management Guide and CLI Reference Guide.
a. Setting an IP Address Using the CLI
Connect a PC to the switch console port using the included
RJ-45 to DB-9 console cable.
Configure the PC’s serial port: 115200 bps, 8 characters, no
parity, one stop bit, 8 data bits, and no flow control.
As connections are made, check the port status LEDs to be
sure the links are valid. Press the Mode button to change
from Ethernet to PoE status:
◆
On/Blinking Green — Port has a valid link. Blinking
indicates network activity.
◆
On Amber — Port is supplying PoE power.
– 2 –
Safety and Regulatory Information
CLASS 1
LASER PRODUCT
PRODUIT LASER
DE CLASSE 1
LASERPRODUKT
DER KLASSE 1
Quick Start Guide
FCC Class A
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
You are cautioned that changes or modifications not expressly approved
by the party responsible for compliance could void your authority to
operate the equipment.
You may use unshielded twisted-pair (UTP) for RJ-45 connections Category 3 or better for 10 Mbps connections, Category 5 or better for
100 Mbps connections, Category 5, 5e, or 6 for 1000 Mbps connections.
For fiber optic connections, you may use 50/125 or 62.5/125 micron
multimode fiber or 9/125 micron single-mode fiber.
CE Mark
CE Mark Declaration of Conformance for EMI and Safety (EEC)
This information technology equipment complies with the requirements
of the Council Directive 2004/108/EC on the Approximation of the laws
of the Member States relating to Electromagnetic Compatibility and
2006/95/EC for electrical equipment used within certain voltage limits
and the Amendment Directive 93/68/EEC. For the evaluation of the
compliance with these Directives, the following standards were applied:
RFI Emission:
◆Limit according to EN 55032:2012+AC:2013, Class A
◆Limit for harmonic current emission according to EN 61000-3-
2:2014, Class A
◆Limitation of voltage fluctuation and flicker in low-voltage supply
system according to EN 61000-3-3:2013
Immunity:
◆Product family standard according to EN 55024:2010+A1:2015
◆Electrostatic Discharge according to IEC 61000-4-2:2008 ED. 2.0
◆Radio-frequency electromagnetic field according to IEC 61000-4-
3:2010 ED 3.2
◆Electrical fast transient/burst according to IEC 61000-4-4:2012 ED.
3.0
◆Surge immunity test according to IEC 61000-4-5:2014 ED. 3.0
◆Immunity to conducted disturbances, Induced by radio-frequency
fields: IEC 61000-4-6:2013 ED. 4.0
◆Power frequency magnetic field immunity test according to IEC
61000-4-8:2009 ED. 2.0
◆Voltage dips, short interruptions and voltage variations immunity
The Declaration of Conformity (DoC) can be obtained from
www.ignitenet.com/support.
Laser Safety
Warning: Fiber Optic Port Safety:
When using a fiber optic port, never look at the
transmit laser while it is powered on. Also, never look
directly at the fiber TX port and fiber cable ends when
they are powered on.
Avertissment: Ports pour fibres optiques - sécurité sur le plan optique
Ne regardez jamais le laser tant qu'il est sous tension.
Ne regardez jamais directement le port TX
(Transmission) à fibres optiques et les embouts de
câbles à fibres optiques tant qu'ils sont sous tension.
Niemals ein Übertragungslaser betrachten, während
dieses eingeschaltet ist. Niemals direkt auf den FaserTX-Anschluß und auf die Faserkabelenden schauen,
während diese eingeschaltet sind.
:
Power Cord Safety
Please read the following safety information carefully before installing
the switch:
Warning: Installation and removal of the unit must be carried out by
qualified personnel only.
◆The unit must be connected to an earthed (grounded) outlet to
comply with international safety standards.
◆Do not connect the unit to an A.C. outlet (power supply) without an
earth (ground) connection.
◆The appliance coupler (the connector to the unit and not the wall
plug) must have a configuration for mating with an EN 60320/IEC
320 appliance inlet.
◆The socket outlet must be near to the unit and easily accessible. You
can only remove power from the unit by disconnecting the power
cord from the outlet.
◆This unit operates under SELV (Safety Extra Low Voltage) conditions
according to IEC 60950. The conditions are only maintained if the
equipment to which it is connected also operates under SELV
conditions.
France and Peru only
This unit cannot be powered from IT† supplies. If your supplies are of IT
type, this unit must be powered by 230 V (2P+T) via an isolation
transformer ratio 1:1, with the secondary connection point labelled
Neutral, connected directly to earth (ground).
† Impédance à la terre
Important! Before making connections, make sure you have the correct
cord set. Check it (read the label on the cable) against the following:
– 3 –
Quick Start Guide
Power Cord Set
U.S.A. and
Canada
DenmarkThe supply plug must comply with Section 107-2-D1,
SwitzerlandThe supply plug must comply with SEV/ASE 1011.
U.K.The supply plug must comply with BS1363 (3-pin 13 A)
EuropeThe supply plug must comply with CEE7/7 (“SCHUKO”).
Veuillez lire à fond l'information de la sécurité suivante avant d'installer
le Switch:
Avertissement: L’installation et la dépose de ce groupe doivent être
confiés à un personnel qualifié.
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at
least 10 A
The attachment plug must be an earth-grounding type
with NEMA 5-15P (15 A, 125 V) configuration.
Standard DK2-1a or DK2-5a.
and be fitted with a 5 A fuse which complies with
BS1362.
The mains cord must comply with IEC 60227
(designation 60227 IEC 52).
The mains cord must comply with IEC 60227
(designation 60227 IEC 52).
IEC-320 receptacle.
◆Ne branchez pas votre appareil sur une prise secteur (alimentation
électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à
la masse).
◆Vous devez raccorder ce groupe à une sortie mise à la terre (mise à
la masse) afin de respecter les normes internationales de sécurité.
◆Le coupleur d’appareil (le connecteur du groupe et non pas la prise
murale) doit respecter une configuration qui permet un
branchement sur une entrée d’appareil EN 60320/IEC 320.
◆La prise secteur doit se trouver à proximité de l’appareil et son accès
doit être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en
débranchant son cordon électrique au niveau de cette prise.
◆L’appareil fonctionne à une tension extrêmement basse de sécurité
qui est conforme à la norme IEC 60950. Ces conditions ne sont
maintenues que si l’équipement auquel il est raccordé fonctionne
dans les mêmes conditions.
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la
terre. Si vos alimentations sont du type impédance à la terre, ce groupe
doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un
transformateur d’isolement à rapport 1:1, avec un point secondaire de
connexion portant l’appellation Neutre et avec raccordement direct à la
terre (masse).
Cordon électrique - Il doit être agréé dans le pays d’utilisation
Etats-Unis et
Canada:
Danemark:La prise mâle d’alimentation doit respecter la section
Suisse:La prise mâle d’alimentation doit respecter la norme
EuropeLa prise secteur doit être conforme aux normes CEE 7/7
Bitte unbedingt vor dem Einbauen des Switches die folgenden
Sicherheitsanweisungen durchlesen:
Warnun g: Die Installation und der Ausbau des Geräts darf nur durch
Fachpersonal erfolgen.
Le cordon doit avoir reçu l’homologation des UL et un
certificat de la CSA.
Les spécifications minimales pour un cable flexible sont
AWG No. 18, ouAWG No. 16 pour un cable de longueur
inférieure à 2 mètres.
- type SV ou SJ
- 3 conducteurs
Le cordon doit être en mesure d’acheminer un courant
nominal d’au moins 10 A.
La prise femelle de branchement doit être du type à mise
à la terre (mise à la masse) et respecter la configuration
NEMA 5-15P (15 A, 125 V).
107-2 D1 de la norme DK2 1a ou DK2 5a.
SEV/ASE 1011.
(“SCHUKO”)
Le cordon d'alimentation doit être conforme à la norme
IEC 60227 (IEC 60227 désignation 52)
◆Das Gerät sollte nicht an eine ungeerdete Wechselstromsteckdose
angeschlossen werden.
◆Das Gerät muß an eine geerdete Steckdose angeschlossen werden,
welche die internationalen Sicherheitsnormen erfüllt.
◆Der Gerätestecker (der Anschluß an das Gerät, nicht der
Wandsteckdosenstecker) muß einen gemäß EN 60320/IEC 320
konfigurierten Geräteeingang haben.
◆Die Netzsteckdose muß in der Nähe des Geräts und leicht
zugänglich sein. Die Stromversorgung des Geräts kann nur durch
Herausziehen des Gerätenetzkabels aus der Netzsteckdose
unterbrochen werden.
◆Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60950. Diese
Bedingungen sind nur gegeben, wenn auch die an das Gerät
angeschlossenen Geräte unter SELV-Bedingungen betrieben
werden.
Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft
werden:
SchweizDieser Stromstecker muß die SEV/ASE 1011
EuropeDas Netzkabel muss mit IEC 60227 (IEC 60227
Bestimmungen einhalten.
entsprechen Bezeichnung 52)
Der Netzstecker muß die Norm CEE 7/7 erfüllen
(”SCHUKO”).
– 4 –
Warnings and Cautionary Messages
Quick Start Guide
Warning:
parts.
Warning:
out by qualified personnel only.
Warning:
connect the field ground lead on the tri-pole power plug to a
valid earth ground line to prevent electrical hazards.
Warning:
optic cable. The lasers are compliant with the requirements of a
Class 1 Laser Product and are inherently eye safe in normal
operation. However, you should never look directly at a
transmit port when it is powered on.
Warning:
safety, please make sure that it can function at a temperature
that is not less than the recommended maximum operational
temperature of the product. You must also use an approved
Laser Class 1 SFP transceiver.
Caution:
measures to prevent electrostatic discharge when handling this
equipment.
Caution:
port. This may damage this device.
Caution:
that conform to FCC standards.
Caution:
One should position the switch in the rack, while the other
secures it using the mounting screws.
This product does not contain any serviceable user
Installation and removal of the unit must be carried
When connecting this device to a power outlet,
This switch uses lasers to transmit signals over fiber
When selecting a fiber SFP device, considering
Wear an anti-static wrist strap or take other suitable
Do not plug a phone jack connector in the RJ-45
Use only twisted-pair cables with RJ-45 connectors
Installing the switch in a rack requires two people:
– 5 –
Hardware Specifications
Switch Chassis
Size (WxDxH)33.0 x 20.4 x 4.26 cm (12.99 x 8.03 x 1.67 in.)
Weight2.4 kg (5.34 lb)
TemperatureOperating: 0° C to 40° C (32° F to 104° F)