Ignis gamma v 2.15 Quick Manual

1
2
IGNIS gamma v 2.15
Ignis gamma v2.15 is a microprocessor temperature regulator to control the central heating boiler with a solid fuel feeding screw. The Ignis gamma v2.15 controller with room sensor supports the preset room temperatures according to established time programs.
APPLICATION
The purpose of Ignis gamma v2.15 is automatic control of feeding screw, blower, central heating pump (CH pump) and feeding pump for tap water container (TW container).
FRONT PANEL
Controls:
feeding pump for TW container
CH pump
blower
feeding
parameter setting MENU ON/OFF
MENU navigation and parameter setting
MAIN DISPLAYS
controller operation status
current boiler temperature
current tap water temperature
current room temperature
boiler temperature setting
current day/hour
controller daytime
room temperature for daytime
The main displays operate changing in cyclic mode. The boiler temperature can be set on Display 1 using buttons and . The arrow we can use to change displays in manual mode. In 30 seconds the controller returns to its cyclic operation of changing displays.
Mo 12:35 Daily & 21,5*
- day
- day edition
- day selection
- copy to other day
- daytime
- hour selection
- enter the copy
- reset the day for introduced copy
Mo@ EDIT@ COPY#
Mo (! 7@ &21,0* ^^^^^^& &&&& @
Mo@ COPY
TO )Tu @
)Mo@^^^^^^&&&&&& &&&&&&&&====
OPERATION
The boiler is fired up in MANUAL MODE (f). To start MANUAL MODE press MENU and next use and .
When the feeder is started wait till coal is delivered to retort then stop the feeder and fire up the coal. The blower can be used during this operation with its whole range of power.
If there is fire in the whole retort, you can change operation mode into automatic. For this purpose press MENU and next - START. Operation status changes from STOP to FIRE UP. The blower is working with its maximum power and the feeder delivers coal regularly.
When the BURNING OUT TEMPERATURE (M) is exceeded controller starts HEAT.
If maximum and minimum power of the blower are different the quantity of delivered air and fuel decreases (feeder operation time is automatically reduced) as the temperature is drawing near the value preset by user and increases as the temperature is drawing away.
When the preset temperature is exceeded, the controller changes to HOLD mode. The feeder and blower begin periodical operation to keep fire on. Whereas, there is possibility to stop blower as in case of using the sawdust as solid fuel.
If the boiler temperature decreases, controller changes over to HEAT. If the boiler temperature drops below the value of BURNING OUT TEMPERATURE controller changes to STOP status. However controller cannot change to STOP, if the FIRE UP (F) time has not been completed since pressing START, that is setting of 1 hour - made by producer.
The controller operation can be stopped at any time by pressing - STOP. In STOP status the blower and feeder are stopped.
ROOM TEMPERATURES ROOM TEMPERATURES parameter (a) see page 3.
Controller keeps up the room temperature in three daytimes accordingly;
day period, night period, economy period.
The operator can set different room temperature for each of these periods. If the preset room temperature is exceeded the CH pump stops and controller changes to HOLD status.
Each day and hour can have any of those period set.
DAYTIME PROGRAM EDITION DAYTIME PROGRAM parameter(b) see page 3
& ^ =
display informs: Monday 00:00 - 05:59 night period 06:00 - 19:59 day period 20:00 - 23:59 economic period
holding or changes between copy daytime and an hour selection