Instruction Manual
Pastry Display Cases
Models: CURP
CURLP
series
CURP
124 Norfinch Dr. Toronto, ON. M3N 1X1
Tel : 416-663-3051 Fax : 416-663-5793
Toll Free : 1-888-408-8819
CURHP
REFRIGERATION LTD.

www.igloorefrigeration.com | Pastry Display Cases
Contents
Contents ............................................................................................................................................................. 2
1 UNLOADING ..................................................................................................................................................... 3
2 PROPERTIES OF THE UNIT.................................................................................................................................. 3
2.1. Purpose .................................................................................................................................................... 3
2.2. Description of the unit............................................................................................................................... 3
2.3. Technical data ........................................................................................................................................... 4
3. PREPARING THE DEVICE FOR START UP ............................................................................................................ 5
3.1. Installation requirements .......................................................................................................................... 5
3.2. Unit Location ............................................................................................................................................ 5
3.3. Connection and start-up ............................................................................................................................ 6
4. UNIT START UP ............................................................................................................................................... 8
4.1. Temperature regulation ............................................................................................................................ 9
5. MAINTENANCE .............................................................................................................................................. 12
5.1 Cleaning and maintenance ....................................................................................................................... 12
6. SERVICE ......................................................................................................................................................... 14
6.1. Faults identification and repair ................................................................................................................ 14
6.2 Service ..................................................................................................................................................... 15
List of Figures
Figure 1 CURP ..................................................................................................................................................... 4
Figure 2 placing the hooks in the frame ................................................................................................................ 6
Figure 3 Hook height control ................................................................................................................................ 7
Figure 4 Assemble of glass elements .................................................................................................................... 7
Figure 5 Control panel ......................................................................................................................................... 8
Figure 6 “Carel” thermostat control panel ............................................................................................................ 9
Figure 7 Manner of assembling/pulling out the blow in and suction .................................................................... 12
Figure 8 Cleaning the condenser ........................................................................................................................ 13
List of Tables
Table 1 Technical data ......................................................................................................................................... 4
Table 2 Table of alarms and signals .................................................................................................................... 10
Table 3 Table of easy compact parameters ......................................................................................................... 11

Pastry Display Cases | www.igloorefrigeration.com
1 UNLOADING
The unit should be transported in vertical position and properly secured and packed.
2 PROPERTIES OF THE UNIT
2.1. Purpose
“CURP” series display cases are universal cooling devices that are aimed to display and are used for short-term
storage for confectionery goods (such as cakes, cookies, desserts… etc.) in temperature between +1ºC and +4ºC
with ambient temperature between +15ºC and +25ºC and relative air humidity up to 55%, depending on the
environment and the location of the unit.
2.2. Description of the unit
“CURP” series display cases have a dynamic cooling system. All units are equipped with automatic condensate
evaporation and automatic defrosting. The electronic thermostat cooperates module to monitor and send signals
when the temperature inside the equipment gets too low or too high. They can be supplied with self-contained or
remote compressors. Glass shelves fixed on the frame make the exhibitive part of display cases. The height and
angle of the shelves are adjustable. These display cases use energy-saving LED lighting. Our equipment is
manufactured in accordance to modern technologies and has all certificates required by law.
The description in this box signifies important information for user security and for
proper operation of the device.

www.igloorefrigeration.com | Pastry Display Cases
Figure 1 CURP
1 – Upper glass shelf
2 – Front panel
3 – Straight front glass
4 – LED lamp
5 – Inner frame (made of metal plates)
6 – Sliding doors (CURP3 and CURP4) or swing door
(CURP2)
2.3. Technical data
7 – Display glass shelf
8 – Shelf hook for glass shelf (height/angle adjustable)
9 – Condenser cover (DO NOT BLOCK air louver!!!)
10 – Leveling legs
11 – Serial plate
12 – Control panel (thermostat, switches)
Table 1 Technical data
Model Voltage [V/Hz/Ph]

Pastry Display Cases | www.igloorefrigeration.com
3. PREPARING THE DEVICE FOR START UP
The unit must be properly installed and located in accordance with the installation
instructions before it is used.
3.1. Installation requirements
• Always use a dedicated circuit with the amperage stated on the unit.
• Plug into an outlet designed for the plug.
• Do not overload the circuit.
• Do not use extension cords.
• Never use adapters.
• Never plug in more than one unit per electric circuit.
• If in doubt, call an electrician.
IGLOO will not warranty any equipment that is connected to an extension cord or
adapter plug.
The equipment may be turned on after confirmation of the fire protection efficiency
with results of measures performed according to binding regulations!
IGLOO refrigeration uses this type of plugs. If you do not
have the right outlet have a certified electrician install
3.2. Unit Location
• Remove cardboard angles and protective foil.
• Install the unit on a strong and leveled surface.
• To ensure proper operation of the unit, it must be leveled from front to back and left to right.
• Unit may malfunction if improperly leveled.
• Be sure there is sufficient ventilation around the entire unit.
• Select a location away from heat and moisture generating equipment.
• Avoid installation in a high ambient or humid location.
• High ambient temperatures will cause the compressor to overwork.
• Humidity may cause rust, condensation around glass or stainless steel and decrease the efficiency of the
unit.