Instruction Manual
Ice Cream/ Gelato Cases
Models: ARBF & ARB2F series
124 Norfinch Dr. Toronto, ON. M3N 1X1
Tel : 416-663-3051 Fax : 416-663-5793
Toll Free : 1-888-408-8819
ARB2
ARB
REFRIGERATION LTD.

www.igloorefrigeration.com | Ice Cream/ Gelato
Contents
1 UNLOADING ..................................................................................................................................................... 3
2 PROPERTIES OF THE UNIT.................................................................................................................................. 3
2.1. Purpose .................................................................................................................................................... 3
2.2. Description of the unit............................................................................................................................... 3
2.3. Technical data ........................................................................................................................................... 5
3. PREPARING THE DEVICE FOR START UP ............................................................................................................ 6
3.1. Installation requirements .......................................................................................................................... 6
3.2. Unit Location ............................................................................................................................................ 6
3.3. Connection and start-up ............................................................................................................................ 7
4. UNIT START UP ............................................................................................................................................... 9
4.1. Temperature regulation ............................................................................................................................ 9
5. MAINTENANCE .............................................................................................................................................. 12
5.1 Cleaning and maintenance ....................................................................................................................... 12
6. SERVICE ......................................................................................................................................................... 13
6.1 Faults identification and repair ................................................................................................................. 13
6.2 Service ..................................................................................................................................................... 14
List of Figures
Figure 1 ARBF & ARB2F - Overview ...................................................................................................................... 4
Figure 2 ARBF – Layout of containers ................................................................................................................... 4
Figure 3 ARB2F - Layout of containers .................................................................................................................. 4
Figure 4 Leveling legs ........................................................................................................................................... 6
Figure 5 Install internal elements ......................................................................................................................... 7
Figure 6 Control panel ......................................................................................................................................... 7
Figure 7 Front glass panel lifted improperly .......................................................................................................... 8
Figure 8 "Carel" thermostat control panel ............................................................................................................ 9
Figure 9 Cleaning the condenser ........................................................................................................................ 13
List of Figures & Tables
Table 1 Technical data - ARB ................................................................................................................................ 5
Table 2 Technical data - ARB2 .............................................................................................................................. 5
Table 3 Table of alarms and signals .................................................................................................................... 10
Table 4 Table of easy compact parameters for ARB2F & ARBF............................................................................. 11

Ice Cream/ Gelato Cases| www.igloorefrigeration.com
1 UNLOADING
The unit should be transported in vertical position and properly secured and packed.
2 PROPERTIES OF THE UNIT
2.1. Purpose
“ARBF” and “ARB2F” are universal freezing devices aimed for displaying and short-lasting storage of scooped ice
cream in temperature ranging between -24ºC and -15ºC with ambient temperature of +15ºC/+25ºC and relative
air humidity up to 55%, depending on the environment of the unit location.
2.2. Description of the unit
“ARBF” and “ARB2F” display units have dynamic cooling.
The display cases are equipped with automatic defrosting and automatic condensate evaporation. The electronic
thermostat cooperate module to monitor and send signals when the temperature inside the equipment gets too
low or too high. The front glass can be listed with the telescopic system
Our equipment is manufactured in accordance to modern technologies and has all certificates required by law.
The description in this box signifies important information for user security and for
proper operation of the device.

www.igloorefrigeration.com | Ice Cream/ Gelato
ARBF4 _ 14 containers
ARBF8 _ 28 containers
Figure
Figure 3 ARB2F - Layout of containers
Figure 1 ARBF & ARB2F - Overview
1 – LED lamp
2 – Telescopic front glass lifting system
3 – Wooden casing
4 – Leveling legs
5 – Stainless steel work top
6 – Stainless steel containers
7 – Side glass
8 – Serial plate
9 – Control panel
10 – Top shelf –night curtain
11 – Night curtain handle
12 – Condenser cover (DO NOT block the air louver)
2 ARBF – Layout of containers

Ice Cream/ Gelato Cases| www.igloorefrigeration.com
2.3. Technical data
Table 1 Technical data - ARB
[V/Hz/Ph]
[A]
Table 2 Technical data - ARB2
[V/Hz/Ph]
[A]
3. PREPARING THE DEVICE FOR START UP
The unit must be properly installed and located in accordance with the installation
instructions before it is used.
[Qt/L]
[Qt/L]
[lbs/kg]
[lbs/kg]
3.1. Installation requirements
• Always use a dedicated circuit with the amperage stated on the unit.
• Plug into an outlet designed for the plug.
• Do not overload the circuit
• Do not use extension cords
• Never use adapters
• Never plug in more than one unit per electric circuit
• If in doubt, call an electrician.
IGLOO will not warranty any equipment that is connected to an extension cord or
adapter plug.
The equipment may be turned on after confirmation of the fire protection efficiency
with results of measures performed according to binding regulations!