IFM Electronic UGT203, UGT206, UGT509, UGT512 Operating Instructions Manual

Operating instructions
Ultrasonic diffuse-reflection sensor
with IO-Link
UGT203 UGT206 UGT509 UGT512
80275568 / 00 05 / 2018
UK
1 Safety instructions
Read this document before setting up the product and keep it during the entire service life.
The product must be suitable for the corresponding applications and environmental conditions without any restrictions.
Only use the product for its intended purpose (→ 2 Functions and features).
If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator.
Protect units and cables against damage.
2 Functions and features
Ultrasonic sensor for monitoring levels and detecting objects.
3 Installation
3
4
1
2
Secure the unit to a bracket.
1/2: status LEDs 1/2 (yellow),
setting aid and output indication
3: echo LED (green), is on when object or
background is detected
4: teach button
Sound-absorbing surfaces have a negative effect on a reliable function.
► Consider the dead zone (Technical data sheet):
No object detection in the dead zone.