![](/html/bb/bb11/bb116520e61e26b9bb4a3d8f7df6733e9527f010452c8efd2516ce83beb8db5b/bg1.png)
Installation Instructions
Temperature transmitter
TA3233
TA3237
UK
704560 / 01 12 / 2009
![](/html/bb/bb11/bb116520e61e26b9bb4a3d8f7df6733e9527f010452c8efd2516ce83beb8db5b/bg2.png)
1 Functions and features
The temperature transmitter detects the current system temperature and converts
it into an analog output signal (4 ... 20 mA).
• Measuring range:
TA3233 -17,8...148,9 °C / 0...300 °F
TA3237 0...100 °C / 32...212 °F
• Measuring element: Pt1000 to DIN EN 60751, class A
• Temperature resistance
[min]
¥
240
200
160
120
80
40
0
110 115 120 125 130 135 140 145 150
Maximum operation time depending on the medium temperature
2 Installation
Before mounting and removing the unit: ensure that no medium can leak
[°C]
155
at the process connection.
Installation with progressive ring fittings E30024 or E30049.
For information on the installation with progressive ring fittings please refer to the
instructions enclosed with the respective articles.
2