3
UK
9.1 Menu structure ............................................................................................. 23
10 Parameter setting ............................................................................................24
10.1 Parameter setting in general .....................................................................24
10.2 Basic settings ...........................................................................................25
10.2.1 Set unit of measurement [uni] ...........................................................25
10.2.2 Set offset [OFS] ................................................................................25
10.2.3 Set medium [MEdI] ...........................................................................25
10.2.4 Set overflow prevention [OP] .......................................................... 26
10.2.5 Adjust overflow prevention [cOP] ......................................................26
10.3 Set output signals ......................................................................................28
10.3.1 Set output function [ou1] for OUT1 (switching output) ......................28
10.3.2 Set output function [ou2] for OUT2 (analogue output) ......................28
10.3.3 Define switching limits [SP1] / [rp1] (hysteresis function) ................. 28
10.3.4 Define switching limits [FH1] / [FL1] (window function) ....................28
10.3.5 Set switching delay [dS1] for switching output .................................29
10.3.6 Set switch-off delay [dr1] for switching output ..................................29
10.3.7 Define switching logic [P-n] for switching output ..............................29
10.3.8 Define response of the outputs in case of a fault [FOUx] ................. 29
10.3.9 Configure display [diS] ......................................................................29
10.3.10 Reset all parameters to factory settings [rES] ................................29
11 Operation .........................................................................................................30
11.1 Operating indicators ................................................................................... 30
11.2 Read set parameters .................................................................................30
11.3 Error indications ......................................................................................... 31
11.4 Output response in different operating states ............................................31
12 Technical data .................................................................................................. 32
12.1 Setting values [OFS] .................................................................................. 32
12.2 Setting values [OP] .................................................................................... 32
12.3 Calculation aids [OP] .................................................................................33
12.3.1 Definition “from the cover“ ................................................................33
12.3.2 Definition “from the bottom“ ..............................................................34
12.4 Setting ranges switching limits for level ..................................................... 34
13 Maintenance / cleaning / change of medium ..................................................34
13.1 Maintenance information for operation without overflow prevention .........35
14 Factory setting .................................................................................................36