iEi Web Mail Server Service Manual
WMS-2208R
November 2003
Note:
1. The information contained herein is the property of ICP Electronics Inc. The possessor agrees to maintain this document in co nfidence, not to reproduce, copy, reveal or publish it in part or whole in any form.
2. IEI has made reasonable effort to ensure the accuracy and validity of this document; however, IEI specifically disclaims any warranty regarding this document. IEI shall not be liable for any exemplary, incidental, proximate or consequenti al damages or expe nses arisi ng from the use of this document.
IEI CONFIDENTIAL
Page 2
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
2
Table of Contents
CHAPTER 1 INTRODUCTION............................................................................3
OVERVIEW.......................................................................................................... 3
RESOURCES & SUPPORT......................................................................................... 3
CHAPTER 2 ROUTINE MAINTENANCE..............................................................4
MAINTENANCE OVERVIEW...................................................................................... 4
CLEANING........................................................................................................... 4
CHAPTER 3 TROUBLESHOOTING .....................................................................5
INTRODUCTION.................................................................................................... 5
WHO SHOULD PERFORM REPAIRS............................................................................ 5
REPAIR LEVEL SUPPORTED ..................................................................................... 5
USING THIS DOCUMENT......................................................................................... 6
OBTAINING REPLACEMENT PARTS............................................................................ 6
TROUBLESHOOTING GUIDE..................................................................................... 6
CHAPTER 4 DISASSEMBLY GUIDE .................................................................10
OVERVIEW........................................................................................................ 10
SYSTEM DISASSEMBLY AND REASSEMBLY................................................................. 10
CHAPTER 5 SPARE PARTS..............................................................................17
OVERVIEW........................................................................................................ 17
CHAPTER 6 PACKING FOR SHIPMENT ...........................................................18
GENERAL INSTRUCTIONS ..................................................................................... 18
PACKING IN THE ORIGINAL CARTON....................................................................... 18
PACKING IN A DIFFERENT CARTON......................................................................... 18
CHAPTER 7 REINSTALLING FIRMWARE ........................................................20
OVERVIEW........................................................................................................ 20
CHAPTER 8 HARD DISK INSTALLATION........................................................21
OVERVIEW........................................................................................................ 21
HARD DRIVE INSTALLATION PROCEDURE................................................................. 21
CHAPTER 9 FACTORY DEFAULT SETUP ..........................................................23
OVERVIEW........................................................................................................ 23
CREATE DISK VOLUME......................................................................................... 23
APPENDIX A. HARD DRIVE COMPATIBILITY LIST...........................................25
APPENDIX B. CONSOLE CABLE CONNECTION..................................................26
IEI CONFIDENTIAL
Page 3
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
3
Chapter 1 INTRODUCTION
Overview Resources & Support
Overview
This document contains informati on on ho w to pe rform maintenance and troubleshooting procedures on WMS-2208R Web Mail Server. Please note that any electrical system presents potential hazards so these actions should only be performed by qualified personnel. Before operating on your WMS-2208R, please read this user manual carefully for thorough understa nding on it s functi ons.
Resources & Support
IEI is a systems company dedicated to providing innova tive products and first-rate services to all our partners and customers. For further information or documents regarding to our products, please refe r to the following list:
Product information: Firmware update image: User’s manual: FAQ:
For any questions, please contact IEI Customer Service Department at
support@iei.com.tw.
http://www.ia.ieiworld.com/support/
http://www.ieiworld.com/
http://www.ia.ieiworld.com/support/
http://www.ia.ieiworld.com/support/
IEI CONFIDENTIAL
Page 4
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
4
Chapter 2 ROUTINE MAINTENANCE
Maintenance Overview Cleaning
Maintenance Overview
The WMS-2208R requires no routine service.
Cleaning
Caution: DO NOT immerse WMS-2208R in liquid or use caustic or abrasive cleaners.
To clean WMS-2208R, dampen a soft cloth with any commercial nonabrasive cleaner available in the market and wipe clean. Before cleaning, make sure that the system is turned off.
IEI CONFIDENTIAL
Page 5
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
5
Chapter 3 TROUBLESHOOTING
Introduction Who Should Perform Repairs Repair Level Supported Using this Document Obtaining Replacement Parts Troubles hooting Guide
Introduction
This chapter provides information for troubleshooting WMS-2208R and he lping you to isolate a failure to the power adapter, the MailWare flash module, the case fan, the LCD module, the hard disks and the main board. A troubleshooting guide is also provided; it lists possible problems, along with probable causes, and recommended actions on how to correct each problem.
Note: For system manufactured after November 10, 2003, the system firmware is stored at MailWare flash module (DOM) instead of on-board flash. Please be noticed about this change wh en servicing.
Who Should Perform Repairs
Only qualified service personnel should remove and replace any components of WMS-2208R. Repairs to the WMS-2208R are limited to the repair level identified in the following paragraph.
Repair Level Supported
The WMS-2208R has the following replaceable components:
The WMS-2208R main board The front panel assembly, including the LCD module The MailWare flash module (DOM, for system manufactured after November
10, 2003)
The top cover The case fan The power adapter
IEI CONFIDENTIAL
Page 6
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
6
The hard disk
Using this Document
Failures of the top cover, the front panel assembly are determined by v isually inspecting these components for cracks or deformations and for mechanical failures. Use the troubleshooting guide provided in this chapter to isolate failure to the main board, the MailWare flash module or the system firmware, the LCD module, the power adapter, the case fan, or the hard disks. Once a failure has been isolated, refer to Chapter 4, Disassembly Guide for instructions for removing and replacing a component of the WMS-220 8R.
Obtaining Replacement Parts
IEI Customer Services Department provides technical assistance information and replacement parts. To obtain replacement parts, contact the IEI Customer Services Department or your sales representative. Please refer to parts by the part names and part numbers listed in Chapter 5, Spare Parts.
Troubleshooting Guide
If you encounter a problem that cannot be resolved through a visual inspection, check the following lists for probable causes and recommended actions to take to correct the problem. For a symptom that is not listed here, contact the IEI Customer Services Department or your sales representative.
Power Adapter
Symptom Corrective Action
The system does not power up when applying power.
Make sure the power cable and adapter is attached correctly, and there is power to the AC outlet. Replace the power adapter. If the failure persists, replace the main board.
IEI CONFIDENTIAL
Page 7
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
7
Case Fan
Symptom Corrective Action
The system is on but the case fan has stopped working.
The system starts and hangs up.
LCD Module
Symptom Corrective Action
The system works well but no message is displayed on the LCD module.
The system works well but no LED on the LCD module lights up.
Replace the failed case fan.
Replace the front panel assembly, including the LCD module.
Hard Disk
Note: If the failed drive is not configured to a RAID 1 disk volume, there is no chance to retrieve the data stored in it.
Symptom Corrective Action
The hard drive makes strange sounds when working.
Replace the hard disk that makes strange sound.
LCD module shows below error message: "disk drive n failed or unplugged"
First, replace hard disk
Event logs show below error message: "disk drive n failed or is unplugged”
with a good hard disk that you are sure of. If the failure persists, replace
Entering system administration web page and
the main board.
select “System Settings”. “No Disk” message is shown when checking disk status on the page of “Disk Configuration.”
IEI CONFIDENTIAL
Page 8
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
8
System Firmware/ MailWare Flash Module
Caution: Reinstalling system firmware or replacing MailWare flash module will cause the existing configur ation data lost and return to the factory defaults.
Symptom Corrective Action
The system fails to boot successfully and the LCD module displays nothing or just “SYSTEM STARTING” message.
Connect the console cables (refer to Appendix B) to investigate the system booting process. If the system does not report any hardware failure and hangs up after booting (as below figure), reinstall the firmware or replace the MailWare flash module.
IEI CONFIDENTIAL
Page 9
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
9
Main Board
Caution: Replacing the main board will cause the existing configuration data lost and return to the factory defaults.
Symptom Corrective Action
After turning on the power, no “beep” is heard after booting.
The system fails to boot successfully.
The LCD module displays nothing or just “SYSTEM STARTING” message.
After reinstalling system firmware or replacing the MailWare flash module, the system still not works well.
Cannot connect to the network and the network LED is off.
Replace the main board.
Connect the console cables (refer to Appendix B) to investigate the system booting process. If the system reports any hardware failure, replace the main board.
Replace the main board.
Check the network connection first. If there is no problem on network connection, replaces the main board.
IEI CONFIDENTIAL
Page 10
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
0
Chapter 4 DISASSEMBLY GUIDE
Overview System Disassembly & Assembly
Overview
The WMS-2208R can be disassembled into the following assemblies:
The WMS-2208R main board The front panel assembly, including the LCD module The MailWare flash module (DOM, for system manufactured after November
10, 2003)
The top cover The case fan The hard disk
Tools Required
The tools you will need to disassemble or reassemble the WMS-2208R is listed as below:
One number 102 Phillips-head screwdriver One number 107 Phillips-head screwdriver One 5-mm spanner One diagonal pliers (for cutting the cable tie)
Caution: Observe ESD (electrostatic discharge) pr ecautions when disassembling and reassembling the WMS-2208R and when handling any of the components of the WMS-2208R.
System Disassembly and Reassembly
Use the following procedure to disassemble the WMS-2208R, reassemble it in reverse order. It is recommended that you follow this disassembly procedure in the order presented.
Note: Before you begin to disassemble the WMS-2208R, make sure that the system has been shutdown and the power cord is removed.
IEI CONFIDENTIAL
1
Page 11
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
1. Remove the top cover: Unfasten the six screws and push the top cover towards the back to remove it.
IEI CONFIDENTIAL
11
Page 12
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
2
2. Take out the hard disks and case fans:
a. Remove the six screws on the drive trays, then unplug flat cable and
power cable of hard disks as indicated below.
b. Unfasten all screws circled in the picture below and remove hard disks
and case fans.
IEI CONFIDENTIAL
1
Page 13
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
3
3. Detach the MailWare flash module: The MailWare flash module is installed on the 44-pin IDE port (CN2), just unplug it directly.
Note: Only system manufactured after November 10, 2003 comprises the MailWare flash module. For earlier system, the system firmware is stored in on-board flash.
4. Detach the main board:
a. Disconnect the two cables shown in the squares and unfasten the four
screws and two studs shown in the circles.
IEI CONFIDENTIAL
1
Page 14
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
4
b. Remove the six studs as shown below.
c. Disconnect these two connectors shown belo w.
IEI CONFIDENTIAL
1
Page 15
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
5
d. Cut off the cable tie, and disconnect the connector shown in the square
and then loosen the four screws shown in the circles.
e. Take out the CPU CARD upward following the direction o f arrow.
IEI CONFIDENTIAL
1
Page 16
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
6
5. Detach the front panel assembly: Unfasten the four screws shown in the diagram below.
IEI CONFIDENTIAL
1
Page 17
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
7
Chapter 5 SPARE PARTS
Overview
Overview
Spare parts, along with corresponding IEI part numbers, are shown below.
Table 1. WMS-2208R Spare Parts List
Item Part Numbers
WMS-2208R Main Board not including the SDRAM
Front Panel Assembly
including LCD module
MailWare Flash Module (DOM)
only for system manufactured after November 10, 2003
Case Fan 31100-000061
Top Cover 41008-017347-00
Power Adapter 63PSA65U120DJL-001
Service Kits WMS-2208R-SK
004ISS105-00-020
193WMS2208R-000
WMS-2208R-DOM
To obtain spare parts, contact the IEI Customer Services Department or your sales representative.
IEI CONFIDENTIAL
1
Page 18
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
8
Chapter 6 PACKING FOR SHIPMENT
General Instructions Packing in the Original Carton Packing in a Different Carton
General Instructions
To ship a WMS-2208R or one of its components for any reason, please follow the instructions in this section. Pack the WMS-2208R or component carefully. Failure to follow the instructions in this section may result in loss or damage not covered by any applicable IEI warranty. If available, use the original carton and packing materials and follow the instructions in “Packing in the Original Carton.” If the original shipping carton and material are not available, use other suitable shipping materials and container and follow the instructions in Packing in a Different Carton.”
Prior to shipping the WMS-2208R or component, contact IEI Customer Services Department or your sales representative for a Returned Material Authorization (RMA) number. Mark the shipping carton and any shipping forms wi th the RMA number.
Caution: Observe ESD (electrostatic discharge) precautions when packing any WMS-2208R components.
Packing in the Original Carton
If the original carton and packing materials are available, repack the WMS-2208R into the original carton. Add packing material in the carton as needed so the WMS-2208R will not be able to move during shipment.
Packing in a Different Carton
If the original carton and packing material are not available when shipping an WMS-2208R or one of its components:
1. Place the WMS-2208R or component in a plastic bag.
2. Locate a corrugated cardboard shipping carton wi th at l east 200 po un ds per square inch (psi) bursting strength.
3. Fill the bottom of the carton with at least 2 inches of packing material.
4. Place the bagged WMS-2208R or component on the layer of packing material and fill the box completely with packing material such that there is at least 2 inches of packing material around all sides of the item.
IEI CONFIDENTIAL
1
Page 19
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
9
5. Seal the carton with packing tape.
6. Label carton with shipping address, return address, and RMA number.
IEI CONFIDENTIAL
1
Page 20
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
0
Chapter 7 REINSTALLING FIRMWARE
Overview
Overview
Since November 10, 2003, WMS-2208R uses a flash module (CN2 ) to store its firmware. This MailWare flash module is connected to the main board via an IDE socket. There is no need to re-install the firmware, just replaces the MailWare flash module when failed.
Please refer to the disassembly guide for replacing the flash module. To obtain the flash module for replacement, please contact IEI Customer Support Department or your sales representatives.
Caution: After replacing a new MailWare flash modul e, all th e exist in g configuration data will be lost.
After changing a new MailWare flash module, please remember to continue to configure the system to the factory default settings, such as initialize disk configuration. To initialize system configuration, please refer to chapter 9, “Factory Default Setup.”
Note: To reinstall system firmware to WMS-2208R that manufactured before November 10, 2003, please contact iEi Customer Service Department.
IEI CONFIDENTIAL
2
Page 21
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
Chapter 8 HARD DISK INSTALLATION
Overview Hard Drive Installation Procedure
Overview
The WMS-2208R can install up to two 3.5” IDE hard disk drives. To make the system ready for mail service, install at least one hard drive to the WMS-2 208R. Then refer to the chapter 9, “Factory Default Setup”, f or steps to initializ e the installed hard drives for mail storage.
For a list of verified hard drive models, please refer to Appendix A. “Hard Drive Compatibility List.” We strongly recommend customers to use only th e tested hard drive models. IEI cannot guarantee system stability for users who install drives not specified on this list.
Hard Drive Installation Procedure
To use the WMS-2208R, at least one hard disk should be installed. Before installing the hard drives, please make sure the system is off and the power cord has been disconnected. Follow below steps to install the hard drives to the WMS-2208R.
1. Attach stickers onto the hard disks:
c.
HDD1
IEI CONFIDENTIAL
21
Page 22
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
2
2. Put the hard disk onto the drive plate and fasten eight screws as shown below.
Note: Due to the none-standard nature of IDE hard disk drives, each hard drives model might have slightly different physical dimensions. For some models, it may not be possible to fasten the hard disk to the drive plate with all the four screws.
3. Connect the IDE flat cabl e and the power pl ug for each hard dr ive. Fasten the six screws as shown in the picture below.
IEI CONFIDENTIAL
2
Page 23
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
3
Chapter 9 FACTORY DEFAULT SETUP
Overview Create Disk Volume
Overview
When a system is equipped with the hard drives and about to be shipped out, be sure to perform below checks:
Create Disk Volume
Pre-configure the hard drive on the system to a single volume if there is only one hard drive mounted. Pre-configu re the hard drives on the system to a RAID-0 volume if there is two hard drives mounted.
Before performing the factory defaul t setup, start the browser and open the system administration web page of the web mail server.
Create Disk Volume
Follow below steps to configure the default disk volume:
1. In system settings web page, go to “Disk Configuration”. Select “RAID 0 Striping Disk Volume” for the sys tem with t wo hard dri ves.
For single hard drive:
IEI CONFIDENTIAL
2
Page 24
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
4
For two hard drives:
2. Run “Re-initialize”. Please wait for a while until the volume is created.
IEI CONFIDENTIAL
2
Page 25
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
5
Appendix A.
HARD DRIVE COMPATIBILITY LIST
The compatible hard disks listed below have been thoroughly and strictly tested. We strongly recommend customers to use only these tested hard disk models. IEI cannot guarantee system stability for users who install drives not specified on this list.
Table 2. WMS-2208R Hard Drive Compatibility List
Manufacturer Model Capacity
IBM DTLA-305040 40GB IBM IC35L080AVVA07 80GB IBM IC35L120AVVA07 120GB IBM IC35L120AVV207 120GB Maxtor D540-4K 40GB Maxtor 6E040L0510202 40GB Maxtor HD35-800GI-MA 80GB Maxtor 6Y120L004001 120GB Maxtor 4A160J00602 160GB Maxtor 4G160JB 160GB Maxtor 6Y200P0 200GB Seagate ST340824A 40GB Seagate ST380021A 80GB Seagate ST3120023A 120GB WD WD400EB 40GB WD WD800AB 80GB
IEI CONFIDENTIAL
2
Page 26
WMS-2208R WEB MAIL SERVER SERVICE MANUAL
6
Appendix B.
CONSOLE CABLE CONNECTION
To access the system BIOS for diagnosis, you wil l need to connect the monitor and keyboard via the console cables. The console cables are included in the WMS-2208R Service Kits, which can be ordered as a spare part.
Note: Refer to Chapter 6, Spare Parts for ordering the service kits.
Please follow below figure to connect the console cable to the WMS-2208R main board.
Keyboard
Monitor
IEI CONFIDENTIAL
2