Whenever you need to remove a part for maintenance or upgrading,
switch off the power supply and unplug the power cord first.
The IOVU-570M has a terminal block connector on the bottom panel. The IOVU-570M
also supports Power over Ethernet (PoE) through one of its LAN ports.
Page 9
Page 18
IOVU-570M Panel PC
Chapter
3
3 Unpacking
Page 10
Page 19
IOVU-570M Panel PC
3.1 Anti-static Precautions
WARNING:
Failure to take ESD precautions during installation may result in
permanent damage to the IOVU-570M and severe injury to the user.
Electrostatic discharge (ESD) can cause serious damage to electronic components,
including the IOVU-570M. Dry climates are especially susceptible to ESD. It is therefore
critical that whenever the IOVU-570M or any other electrical component is handled, the
following anti-static precautions are strictly adhered to.
Wear an anti-static wristband: Wearing a simple anti-static wristband can
help to prevent ESD from damaging the board.
Self-grounding: Before handling the board touch any grounded conducting
material. During the time the board is handled, frequently touch any
conducting materials that are connected to the ground.
Use an anti-static pad: When configuring the IOVU-570M, place it on an
antic-static pad. This reduces the possibility of ESD damaging the
IOVU-570M.
3.2 Unpacking Precautions
When the IOVU-570M is unpacked, please do the following:
Follow the anti-static precautions outlined in Section
Make sure the packing box is facing upwards so the IOVU-570M does not fall
out of the box.
Make sure all the components shown in Section
3.1.
3.3 are present.
Page 11
Page 20
3.3 Unpacking Checklist
NOTE:
If some of the components listed in the checklist below are missing,
please do not proceed with the installation. Contact the IEI reseller or
vendor you purchased the IOVU-570M from or contact an IEI sales
representative directly. To contact an IEI sales representative, please
send an email to sales@iei.com.tw.
The IOVU-570M is shipped with the following components:
Quantity Item and Part Number Image
IOVU-570M Panel PC
1 IOVU-570M
1 Utility CD including SDK, utilities, and
technical documentation
1 Null modem cable
1 Touch pen
Table 3-1: Package List Contents
Page 12
Page 21
IOVU-570M Panel PC
3.4 Optional Items
Item and Part Number Image
Panel mount kit
ALFPK-08
VESA 75 wall mount kit
AFLWK-07
LCD monitor/PPC arm kit, load capacity of 3kg~7kg
ARM-11 -RS
LCD monitor/PPC stand kit for VESA 75, up to 5kg
STAND-A08-RS
LCD monitor/PPC stand V type for VESA 75, 0~90
degree adjustable hinge and up to 2.5kg capacity
VSTAND-A07
USB magnetic card reader
AFLP-12BMSR-U
Page 13
Page 22
Item and Part Number Image
USB barcode reader (white/black)
AFLP-BRW01-U, AFLPBRB01-U
VFD customer display (green) 5x7 dot matrix
(black/white)
FLP-CDB01, AFLP-CDW01
12V DC 60W power adapter with bare wire, 90-264V
AC input
IOVU-570M Panel PC
63000-FSP0601AD101C760-RS
DC 12 V input 60 W UPS module with 3800mAH,
2S2P Li-Ion battery, VESA 75
AUPS-A10-R10
Table 3-2: Optional Items
Page 14
Page 23
IOVU-570M Panel PC
Chapter
4
4 Installation
Page 15
Page 24
4.1 Installation Precautions
During installation, be aware of the precautions below:
Read the user manual: The user manual provides a complete description of
the IOVU-570M, installation instructions and configuration options.
DANGER! Disconnect Power: Power to the IOVU-570M must be
disconnected during the installation process, or before any attempt is made to
access the rear panel. Electric shock and personal injury might occur if the
rear panel of the IOVU-570M is opened while the power cord is still
connected to an electrical outlet.
Qualified Personnel: The IOVU-570M must be installed and operated only
by trained and qualified personnel. Maintenance, upgrades, or repairs may
only be carried out by qualified personnel who are familiar with the associated
dangers.
IOVU-570M Panel PC
Air Circulation: Make sure there is sufficient air circulation when installing the
IOVU-570M. The IOVU-570M’s cooling vents must not be obstructed by any
objects. Blocking the vents can cause overheating of the IOVU-570M. Leave
at least 5 cm of clearance around the IOVU-570M to prevent overheating.
Grounding: The IOVU-570M should be properly grounded. The voltage feeds
must not be overloaded. Adjust the cabling and provide external overcharge
protection per the electrical values indicated on the label attached to the back
of the IOVU-570M.
4.2 SD Card Installation
The IOVU-570M supports a single SD card. To install the SD card, follow the steps below.
Step 1: Undo the SD card cover screw.
Step 2: Slide open the SD card cover.
Step 3: Slide the SD card into the slot. Replace the SD card slot cover and screw.
Step 0:
Page 16
Page 25
IOVU-570M Panel PC
Figure 4-1: SD Card Installation
4.3 External Peripheral Interface Connectors
Table 4-1 lists the external interface connectors on the IOVU-570M. Detailed descriptions
of the connectors can be found following the table.
Connector Type
12-36 V DC bare wire power terminal Terminal Block
Ethernet connectors RJ-45 Jack connector
RS-232/422/485 Serial connector D-sub 9 Male connector
USB connectors Dual USB port
Table 4-1: External Interface Connectors
Figure 4-2: IOVU-570M Peripheral Connectors
Page 17
Page 26
4.3.1 12 V~36 V DC Terminal Block
The power terminal block connects to a 12 V~36 V DC power source.
CN Label: 12-36 V
IOVU-570M Panel PC
CN Type:
CN Location:
CN Pinouts:
Terminal block
Figure 4-2
See
Table 4-2 and Figure 4-3
See
Pin Description
1 12~36 V DC Power in
2 GND
Table 4-2: 12~36 V Power Connector Pinouts
Figure 4-3: Power Terminal Block
4.3.2 RS-232/422/485 Serial Port
This section outlines the usage and setup of the serial port on the rear I/O panel.
4.3.2.1 Connecting the Serial Port
The IOVU-570M has a single female DB-9 connector on the external peripheral interface
panel for a serial device. Follow the steps below to connect a serial device to the
IOVU-570M.
Step 1: Insert the serial connector.Insert the DB-9 connector of a serial device into
the DB-9 connector on the external peripheral interface. See
Page 18
Figure 4-4.
Page 27
IOVU-570M Panel PC
Figure 4-4: Serial Device Connector
Step 2: Secure the connector. Secure the serial device connector to the external
interface by tightening the two retention screws on either side of the connector.
4.3.2.2 RS-232/422/485 Selection
To select RS-232, RS-422, or RS-485 mode, please follow the directions below.
Step 1: Select "Start > Programs > IEI > IEI CEUTILITY.exe" to run IEI_CEUTILITY.exe
in the “SYSTEM” folder on the SD/CF card).
Step 0:
Page 19
Page 28
IOVU-570M Panel PC
Figure 4-5: Serial Port Mode Setting
Step 2: Change serial port mode setting. Change the value in
desired mode setting.
Step 3: Click "Set"
Step 4: Click "Save Registry" to save the changes.
Step 0:
4.3.2.3 Pinouts
Serial port pinouts are shown below.
Pin RS-232 RS-422 RS-485
1 DCD RXD- DATA-
2 RX RXD+ DATA+
3 TX TXD-
Figure 4-5 to the
Page 20
4 DTR
5 GND GND GND
Page 29
IOVU-570M Panel PC
Pin RS-232 RS-422 RS-485
6 DSR
7 RTS TXD+
8 CTS
9 RI
Table 4-3: Serial Port Pinouts
Figure 4–6: Serial Port Pinouts
4.3.2.4 RS-485 Terminator Jumper Setting
NOTE:
A jumper is a metal bridge that is used to
close an electrical circuit. It consists of two
metal pins and a small metal clip with a
plastic cover. To CLOSE, connect the
jumper. To OPEN, leave the jumper off.
Enables a 120Ω resistor for an RS-485 network.
Pin Description
Open No resistor
Closed 120Ω resistor
Table 4-4: Serial Port Terminator Settings
Page 21
Page 30
4.3.3 USB Connectors
The external USB Series "A" receptacle connectors provide easier and quicker access to
external USB devices. Follow the steps below to connect USB devices to the IOVU-570M.
Step 1: Insert a USB Series "A" plug.Insert the USB Series "A" plug of a device into
the USB Series "A" receptacle on the external peripheral interface. See
Figure 4-7.Step 1:
IOVU-570M Panel PC
Page 22
Figure 4-7: USB Connector
USB devices connect directly to the USB connectors on the external peripheral connector
panel.
Pin Description Pin Description
1 VCC 5 VCC
2 D1- 6 D2-
3 D1+ 7 D2+
4 GND 8 GND
Table 4-5: USB Connector Pinouts
Page 31
IOVU-570M Panel PC
4.3.4 Ethernet Connector
There are two external RJ-45 LAN connectors. The RJ-45 connectors enable connection
to an external network. To connect a LAN cable with an RJ-45 connector, please follow
the instructions below.
Step 2: Align the connectors. Align the RJ-45 connector on the LAN cable with one of
the RJ-45 connectors on the IOVU-570M. See
Figure 4-8: LAN Connection
Figure 4-8.
Step 3: Insert the LAN cable RJ-45 connector. Once aligned, gently insert the LAN
cable RJ-45 connector into the on-board RJ-45 connector.Step 0:
The Ethernet connector pinouts are shown below.
PIN DESCRIPTION
1 TPT+
2 TPT-
3 TPR+
4 LAN_GND
5 LAN_GND
6 TPR-
Page 23
Page 32
PIN DESCRIPTION
7 LAN_GND
8 LAN_GND
IOVU-570M Panel PC
Table 4-6: Ethernet Connector Pinouts
Figure 4-9: Ethernet Connector
The RJ-45 Ethernet connector has two status LEDs, one green and one yellow. The green
LED indicates activity on the port and the yellow LED indicates the port is linked
(
Table 4-7).
SPEED LED LINK LED
Status Description Status Description
GREEN ON: 100 MB
OFF: 10 MB
Table 4-7: Ethernet Connector LEDs
YELLOW ON: Linked
Flashing: Activity
4.4 Mounting the System
WARNING!
When mounting the flat panel PC onto an arm, onto the wall or onto a
panel, it is better to have more than one person to help with the
installation to make sure the panel PC does not fall down and get
damaged.
Three methods of mounting the IOVU-570M are listed below.
Wall mounting
Panel mounting
Page 24
Page 33
IOVU-570M Panel PC
Arm mounting
The mounting methods are described below.
4.4.1 Wall Mounting
To mount the IOVU-570M onto the wall, please follow the steps below.
Step 1: Select the location on the wall for the wall-mounting bracket.
Step 2: Carefully mark the locations of the four screw holes in the bracket on the wall.
Step 3: Drill four pilot holes at the marked locations on the wall for the bracket retention
screws.
Step 4: Align the wall-mounting bracket screw holes with the pilot holes.
Step 5: Secure the mounting-bracket to the wall by inserting the retention screws into
the four pilot holes and tightening them (
Figure 4-10: Wall-mounting Bracket
Figure 4-10).
Step 6: Insert the four monitor mounting screws provided in the wall mounting kit into the
four screw holes on the real panel of the IOVU-570M and tighten until the screw
shank is secured against the rear panel (
Figure 4-11).
Page 25
Page 34
Step 7: Align the mounting screws on the monitor rear panel with the mounting holes on
the bracket.
Step 8: Carefully insert the screws through the holes and gently pull the monitor
IOVU-570M Panel PC
downwards until the monitor rests securely in the slotted holes (
Ensure that all four of the mounting screws fit snuggly into their respective
slotted holes.
Figure 4-11).
NOTE:
In the diagram below the bracket is already installed on the wall.
Page 26
Figure 4-11: Chassis Support Screws
Step 9: Secure the panel PC by fastening the retention screw of the wall-mounting
bracket. (
Figure 4-12).Step 9:
Page 35
IOVU-570M Panel PC
Figure 4-12: Secure the IOVU-570M
4.4.2 Panel Mounting
The IOVU-570M can be mounted in a panel.
CAUTION:
When mounting the IOVU-570M take care to tighten the retention
screws or bolts until fully secure, but do not over tighten. Over
tightening the retention screws or bolts may cause them to become
stripped, rendering them useless.
To mount the IOVU-570M into a panel, please follow the steps below.
Step 10: Select the position on the panel to mount the IOVU-570M.
Step 11: Cut out a section from the panel that corresponds to the rear panel dimensions
of the IOVU-570M. Take care that the panel section that is cut out is smaller than
Page 27
Page 36
the overall size of the frame that surrounds the IOVU-570M but just large
IOVU-570M Panel PC
enough for the rear panel of the IOVU-570M to fit through (see
Figure 4-13: IOVU-570M Panel Opening (mm)
Step 12: Slide the IOVU-570M through the hole until the frame is flush against the panel.
Step 13: Insert the panel mounting clamps into the pre-formed holes along the edges of
the chassis, behind the frame.
Figure 4-13).
Page 28
Figure 4-14: Panel Mounting Clamp
Step 14: Tighten the screws that pass through the panel mounting clamps until the plastic
caps at the front of all the screws are firmly secured to the panel (
Figure 4-15).Step 14:
Page 37
IOVU-570M Panel PC
Figure 4-15: Tighten the Panel Mounting Clamp Screws
4.4.3 Arm Mounting
The IOVU-570M is VESA (Video Electronics Standards Association) compliant and can be
mounted on an arm with a 75 mm interface pad. To mount the IOVU-570M on an arm,
please follow the steps below.
Step 15: The arm is a separately purchased item. Please correctly mount the arm onto
the surface it uses as a base. To do this, refer to the installation documentation
that came with the mounting arm.
NOTE:
When purchasing the arm please ensure that it is VESA compliant and
that the arm has a 75 mm interface pad. If the mounting arm is not
VESA compliant it cannot be used to support the IOVU-570M.
Step 16: Once the mounting arm has been firmly attached to the surface, lift the
IOVU-570M onto the interface pad of the mounting arm.
Page 29
Page 38
Step 17: Align the retention screw holes on the mounting arm interface with those on the
IOVU-570M.
Step 18: Secure the IOVU-570M to the interface pad by inserting four retention screws
through the bottom of the mounting arm interface pad and into the IOVU-570M.Step 0:
4.4.4 Stand Mounting
The IOVU-570M has Video Electronics Standards Association (VESA) standard mounting
holes tapped into the rear panel. The monitor stand mounting plate has a matching VESA
hole pattern. To mount the IOVU onto a stand, please follow the steps below.
Step 1: Line up the threaded holes on the monitor rear panel with the screw holes on the
monitor stand mounting plate.
IOVU-570M Panel PC
Step 2: Secure the monitor to the stand with the supplied retention screws
Figure 4-16: Stand Mounting
4.5 Software
The IOVU-570M comes with a pre-installed Windows CE 5.0 or Linux 2.6.x operating
Figure 4-16).Step 0:
(
Page 30
system and a rich software application development kit. For information about configuring
the operating system, adding remote management tools or additional software and
drivers, refer to the user manuals on IEI IOVU Utility CD that came with the IOVU-570M.
The IOVU includes the following software:
Page 39
IOVU-570M Panel PC
Standard Windows® CE5.0 professional version license.
Optional Board Support Package (BSP) for customers to customize their own
OS image.
Attached Software Development Kit (SDK) for embedded Visual C++ to
program Windows CE application.
Built-in .NET Compact Framework support with related SDK
Thin Client Technology, Microsoft RDP (Remote Desktop Protocol), to enable
IOVU-570M to access Microsoft Windows® based applications installed on
Microsoft Terminal Service server.
Free pre-installed utilities for configuring and diagnosing your IOVU-570M.
Free remote management tools installed in laptop for remotely configuring,
monitoring, and managing your IOVU-570M.
Page 31
Page 40
IOVU-570M Panel PC
Appendix
A
A Certifications
Page 32
Page 41
IOVU-570M Panel PC
A.1 RoHS Compliant
All models in the IOVU series comply with the Restriction of Hazardous Materials (RoHS)
Directive. This means that all components used to build the industrial workstations and the
workstation itself are RoHS compliant.
The RoHS Directive bans the placing on the EU market of new electrical and electronic
equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent
chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE)
flame retardants.
A.2 IP 64 Compliant Front Panel
The front panels on all models in the IOVU series have an ingress protection rating (IP) of
64, IP 64 or greater. The front panels are protected from dust particles and splashed
water.
Page 33
Page 42
IOVU-570M Panel PC
Appendix
B
B Safety Precautions
Page 34
Page 43
IOVU-570M Panel PC
B.1 Safety Precautions
WARNING:
The precautions outlined in this appendix should be strictly followed.
Failure to follow these precautions may result in permanent damage to
the IOVU-570M.
Please follow the safety precautions outlined in the sections that follow:
B.1.1 General Safety Precautions
Please ensure the following safety precautions are adhered to at all times.
Make sure the power is turned off and the power cord is disco nnected
whenever the IOVU-570M is being installed, moved or modified.
Do not apply voltage levels that exceed the specified voltage range.
Doing so may cause fire and/or an electrical shock.
Electric shocks can occur if the IOVU-570M chassis is opened when the
IOVU-570M is running.
Do not drop or insert any objects into the ventilation openings of the
IOVU-570M.
If considerable amounts of dust, water, or fluids enter the IOVU-570M,
turn off the power supply immediately, unplug the power cord, and contact the
IOVU-570M vendor.
DO NOT:
o Drop the IOVU-570M against a hard surface.
o Strike or exert excessive force onto the LCD panel.
o Touch any of the LCD panels with a sharp object
o In a site where the ambient temperature exceeds the rated temperature
Page 35
Page 44
B.1.2 Anti-static Precautions
WARNING:
Failure to take ESD precautions during the installation of the
IOVU-570M may result in permanent damage to the IOVU-570M and
severe injury to the user.
Electrostatic discharge (ESD) can cause serious damage to electronic components,
including the IOVU-570M. Dry climates are especially susceptible to ESD. It is therefore
critical that whenever the IOVU-570M is opened and any of the electrical components are
handled, the following anti-static precautions are strictly adhered to.
Wear an anti-static wristband: Wearing a simple anti-static wristband can
IOVU-570M Panel PC
help to prevent ESD from damaging any electrical component.
Self-grounding: Before handling any electrical component, touch any
grounded conducting material. During the time the electrical component is
handled, frequently touch any conducting materials that are connected to the
ground.
Use an anti-static pad: When configuring or working with an electrical
component, place it on an antic-static pad. This reduces the possibility of ESD
damage.
Only handle the edges of the electrical component: When handling the
electrical component, hold the electrical component by its edges.
B.2 Maintenance and Cleaning Precautions
When maintaining or cleaning the IOVU-570M, please follow the guidelines below.
B.2.1 Maintenance and Cleaning
Prior to cleaning any part or component of the IOVU-570M, please read the details below.
Page 36
Except for the LCD panel, never spray or squirt liquids directly onto any other
components. To clean the LCD panel, gently wipe it with a piece of soft dry
cloth or a slightly moistened cloth.
Page 45
IOVU-570M Panel PC
The interior of the IOVU-570M does not require cleaning. Keep fluids away
from the IOVU-570M interior.
Be cautious of all small removable components when vacuuming the
IOVU-570M.
Turn the IOVU-570M off before cleaning the IOVU-570M.
Never drop any objects or liquids through the openings of the IOVU-570M.
Be cautious of any possible allergic reactions to solvents or chemicals used
when cleaning the IOVU-570M.
Avoid eating, drinking and smoking within vicinity of the IOVU-570M.
B.2.2 Cleaning Tools
Some components in the IOVU-570M may only be cleaned using a product specifically
designed for the purpose. In such case, the product will be explicitly mentioned in the
cleaning tips. Below is a list of items to use when cleaning the IOVU-570M.
Cloth – Although paper towels or tissues can be used, a soft, clean piece of
cloth is recommended when cleaning the IOVU-570M.
Water or rubbing alcohol – A cloth moistened with water or rubbing alcohol
can be used to clean the IOVU-570M.
Using solvents – The use of solvents is not recommended when cleaning the
IOVU-570M as they may damage the plastic parts.
Vacuum cleaner – Using a vacuum specifically designed for computers is
one of the best methods of cleaning the IOVU-570M. Dust and dirt can restrict
the airflow in the IOVU-570M and cause its circuitry to corrode.
Cotton swabs - Cotton swaps moistened with rubbing alcohol or water are
excellent tools for wiping hard to reach areas.
Foam swabs - Whenever possible, it is best to use lint free swabs such as
foam swabs for cleaning.
Page 37
Page 46
IOVU-570M Panel PC
Appendix
C
C Hazardous Materials
Disclosure
Page 38
Page 47
IOVU-570M Panel PC
C.1 Hazardous Materials Disclosure Table for IPB Products
Certified as RoHS Compliant Under 2002/95/EC Without
Mercury
The details provided in this appendix are to ensure that the product is compliant with the
Peoples Republic of China (China) RoHS standards. The table below acknowledges the
presences of small quantities of certain materials in the product, and is applicable to China
RoHS only.
A label will be placed on each product to indicate the estimated “Environmentally Friendly
Use Period” (EFUP). This is an estimate of the number of years that these substances
would “not leak out or undergo abrupt change.” This product may contain replaceable
sub-assemblies/components which have a shorter EFUP such as batteries and lamps.
These components will be separately marked.
Please refer to the table on the next page.
Page 39
Page 48
Toxic or Hazardous Substances and Elements Part Name
IOVU-570M Panel PC
Housing
Display
Printed Circuit
Board
Metal
Fasteners
Cable
Assembly
Fan Assembly
Power Supply
Assemblies
Lead
(Pb)
X O O O O X
X O O O O X
X O O O O X
X O O O O O
X O O O O X
X O O O O X
X O O O O X
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(CR(VI))
Polybrominated
Biphenyls
(PBB)
Polybrominated
Diphenyl
Ethers
(PBDE)
Battery
O: This toxic or hazardous substance is contained in all of the homogeneous materials for the part is
below the limit requirement in SJ/T11363-2006
X: This toxic or hazardous substance is contained in at least one of the homogeneous materials for
this part is above the limit requirement in SJ/T11363-2006