Step 4: You must input the password into the Network key. Click OK. The soft AP
configuration is finished. (Figure 3-114).
Figure 3-14: Wireless AP Connected
Step 5: Click the IP Information button to view the information of the Wireless AP Solo. If
the server function is enabled on the AP. You can automatically get the IP
address, subnet mask. (Figure 3-115)
Figure 3-15: IP Information
Page 25
IOVU-430M Panel PC
Appendix
A
A Certifications
Page 26
IOVU-430M Panel PC
A.1 RoHS Compliant
All models in the IOVU series comply with the Restriction of Hazardous Materials (RoHS)
Directive. This means that all components used to build the industrial workstations and the
workstation itself are RoHS compliant.
The RoHS Directive bans the placing on the EU market of new electrical and electronic
equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent
chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE)
flame retardants.
A.2 IP 65 Compliant Front Panel
The front panel on the IOVU-430M models in the IOVU series have an ingress protection
rating (IP) of 65, IP 65. The front panel is protected from dust particles and water projected
by a nozzle.
Page 27
IOVU-430M Panel PC
Appendix
B
B Safety Precautions
Page 28
IOVU-430M Panel PC
B.1 Safety Precautions
WARNING:
The precautions outlined in this appendix should be strictly followed.
Failure to follow these precautions may result in permanent damage to
the IOVU-430M.
Please follow the safety precautions outlined in the sections that follow:
B.1.1 General Safety Precautions
Please ensure the following safety precautions are adhered to at all times.
Make sure the power is turned off and the power cord is disconnected
whenever the IOVU-430M is being installed, moved or modified.
Do not apply voltage levels that exceed the specified voltage range.
Doing so may cause fire and/or an electrical shock.
Electric shocks can occur if the IOVU-430M chassis is opened when the
IOVU-430M is running.
Do not drop or insert any objects into the ventilation openings of the
IOVU-430M.
If considerable amounts of dust, water, or fluids enter the IOVU-430M,
turn off the power supply immediately, unplug the power cord, and contact the
IOVU-430M vendor.
DO NOT:
o Drop the IOVU-430M against a hard surface.
o Strike or exert excessive force onto the LCD panel.
o Touch any of the LCD panels with a sharp object
o In a site where the ambient temperature exceeds the rated temperature
Page 29
B.1.2 Anti-static Precautions
WARNING:
Failure to take ESD precautions during the installation of the
IOVU-430M may result in permanent damage to the IOVU-430M and
severe injury to the user.
Electrostatic discharge (ESD) can cause serious damage to electronic components,
including the IOVU-430M. Dry climates are especially susceptible to ESD. It is therefore
critical that whenever the IOVU-430M is opened and any of the electrical components are
handled, the following anti-static precautions are strictly adhered to.
Wear an anti-static wristband: Wearing a simple anti-static wristband can
IOVU-430M Panel PC
help to prevent ESD from damaging any electrical component.
Self-grounding: Before handling any electrical component, touch any
grounded conducting material. During the time the electrical component is
handled, frequently touch any conducting materials that are connected to the
ground.
Use an anti-static pad: When configuring or working with an electrical
component, place it on an antic-static pad. This reduces the possibility of ESD
damage.
Only handle the edges of the electrical component: When handling the
electrical component, hold the electrical component by its edges.
B.2 Maintenance and Cleaning Precautions
When maintaining or cleaning the IOVU-430M, please follow the guidelines below.
B.2.1 Maintenance and Cleaning
Prior to cleaning any part or component of the IOVU-430M please read the details below.
Except for the LCD panel, never spray or squirt liquids directly onto any other
components. To clean the LCD panel, gently wipe it with a piece of soft dry
cloth or a slightly moistened cloth.
Page 30
IOVU-430M Panel PC
The interior of the IOVU-430M does not require cleaning. Keep fluids away
from the IOVU-430M interior.
Be cautious of all small removable components when vacuuming the
IOVU-430M.
Turn the IOVU-430M off before cleaning the IOVU-430M.
Never drop any objects or liquids through the openings of the IOVU-430M.
Be cautious of any possible allergic reactions to solvents or chemicals used
when cleaning the IOVU-430M.
Avoid eating, drinking and smoking within vicinity of the IOVU-430M.
B.2.2 Cleaning Tools
Some components in the IOVU-430M may only be cleaned using a product specifically
designed for the purpose. In such case, the product will be explicitly mentioned in the
cleaning tips. Below is a list of items to use when cleaning the IOVU-430M.
Cloth – Although paper towels or tissues can be used, a soft, clean piece of
cloth is recommended when cleaning the IOVU-430M.
Water or rubbing alcohol – A cloth moistened with water or rubbing alcohol
can be used to clean the IOVU-430M.
Using solvents – The use of solvents is not recommended when cleaning the
IOVU-430M as they may damage the plastic parts.
Vacuum cleaner – Using a vacuum specifically designed for computers is
one of the best methods of cleaning the IOVU-430M. Dust and dirt can restrict
the airflow in the IOVU-430M and cause its circuitry to corrode.
Cotton swabs - Cotton swaps moistened with rubbing alcohol or water are
excellent tools for wiping hard to reach areas.
Foam swabs - Whenever possible, it is best to use lint free swabs such as
foam swabs for cleaning.
Page 31
IOVU-430M Panel PC
B.3 FCC Precautions
WARNING:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this
equipment.
This device and its antenna(s) must not be co-located or operating in conjunction
with any other antenna or transmitter.
IMPORTANT NOTE:
For product available in the USA/Canada market, only channel 1~11 can be
operated. Selection of other channels is not possible.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Page 32
IOVU-430M Panel PC
C Hazardous Materials
Appendix
C
Disclosure
Page 33
IOVU-430M Panel PC
C.1 Hazardous Materials Disclosure Table for IPB Products
Certified as RoHS Compliant Under 2002/95/EC Without
Mercury
The details provided in this appendix are to ensure that the product is compliant with the
Peoples Republic of China (China) RoHS standards. The table below acknowledges the
presences of small quantities of certain materials in the product, and is applicable to China
RoHS only.
A label will be placed on each product to indicate the estimated “Environmentally Friendly
Use Period” (EFUP). This is an estimate of the number of years that these substances
would “not leak out or undergo abrupt change.” This product may contain replaceable
sub-assemblies/components which have a shorter EFUP such as batteries and lamps.
These components will be separately marked.
Please refer to the table on the next page.
Page 34
IOVU-430M Panel PC
Toxic or Hazardous Substances and Elements Part Name
Lead
(Pb)
Housing X O O O O X
Display X O O O O X
Printed Circuit
Board
Metal
Fasteners
Cable
Assembly
Fan Assembly X O O O O X
Power Supply
Assemblies
X O O O O X
X O O O O O
X O O O O X
X O O O O X
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(CR(VI))
Polybrominated
Biphenyls
(PBB)
Polybrominated
Diphenyl
Ethers
(PBDE)
Battery O O O O O O
O: This toxic or hazardous substance is contained in all of the homogeneous materials for the part is
below the limit requirement in SJ/T11363-2006
X: This toxic or hazardous substance is contained in at least one of the homogeneous materials for
this part is above the limit requirement in SJ/T11363-2006