IDT ZMOD4510 Programming Manual

ZMOD4510 Programming Manual – Read Me
© 2019 Integrated Device Technology, Inc. 1 September 4, 2019
Contents
1. Introduction ...................................................................................................................................................................................................2
2. Hardware Setup for the ZMOD4510 .............................................................................................................................................................2
3. General Program Flow for Setting up ZMOD4510 Gas Measurements .......................................................................................................3
4. Description of the Programming Example Code...........................................................................................................................................4
4.1 main Files ...........................................................................................................................................................................................4
4.2 Program Flow to Operate the Sensor ................................................................................................................................................4
5. Using the Example on a Different Hardware Platform ..................................................................................................................................5
5.1 Adaptation for the Target System ......................................................................................................................................................5
5.2 Error Codes ........................................................................................................................................................................................5
6. Revision History ............................................................................................................................................................................................6
List of Figures
Figure 1. ZMOD4510 Evaluation Kit ...................................................................................................................................................................2
Figure 2. File Overview for ZMOD4510 ..............................................................................................................................................................3
Figure 3. System Hierarchy ................................................................................................................................................................................5
List of Tables
Table 1. Program Flow ......................................................................................................................................................................................4
ZMOD4510 Programming Manual – Read Me
© 2019 Integrated Device Technology, Inc. 2 September 4, 2019

1. Introduction

This document describes a general program flow to set up ZMOD4510 gas sensor modules for outdoor air quality (OAQ) gas measurements. In addition, it describes the function of an example code provided as a C file by IDT for the ZMOD4510, which can be operated using its evaluation kit (EVK).
Recommendation: Before using this document, read the ZMOD4510 Datasheet available on IDT.com.

2. Hardware Setup for the ZMOD4510

To implement the ZMOD4510 sensor with the user’s program, specific hardware is needed. The following example shows the ZMOD4510 EVK, which consist of three components:
HiCom Communication Board ZMOD4510 Sensor Board (Daughter Board) with the ZMOD4510 Gas Sensor Module Micro-USB cable
For instructions on assembly, connections, and installation of hardware and software, refer to the ZMOD4510 Evaluation Kit Description. Figure 1 shows the assembled evaluation kit.
Figure 1. ZMOD4510 Evaluation Kit
USB Cable to Computer
HiCom Communication Board
ZMOD4510
Sensor Board
ZMOD4510
Loading...
+ 4 hidden pages