IDS 816 Installer Manual

Page 1
Page 2
IDS 816 700-283-02I Issued September 2009
2
Page 3
IDS 816 700-283-02I Issued September 2009
3
1. Introduction to the IDS 816 ----------------------------------------------------------------------------- 8
1.1 Features of the IDS 816 --------------------------------------------------------------------------------------8
2. Installation and Wiring ----------------------------------------------------------------------------------- 9
2.1 Additional Technical Data --------------------------------------------------------------------------------- 10
2.2 End-of-Line Resistors--------------------------------------------------------------------------------------- 10
2.3 Box Tamper Input ------------------------------------------------------------------------------------------- 12
2.4 Installing an Expander Module --------------------------------------------------------------------------- 12
2.5 Connecting the Telephone Communicator ------------------------------------------------------------ 12
2.6 Programmable Outputs ------------------------------------------------------------------------------------ 12
2.7 Key-switch or Remote Control Unit ---------------------------------------------------------------------- 12
2.8 IDS Remote Receiver --------------------------------------------------------------------------------------- 13
2.9 Radio Transmitter Connection ---------------------------------------------------------------------------- 13
3. Hardware Reset Switch --------------------------------------------------------------------------------- 13
4. Enrolling Keypads and Other Devices ------------------------------------------------------------- 13
4.1 Replacing a Faulty Keypad/Device ---------------------------------------------------------------------- 14
4.2 Defaulting Keypads ----------------------------------------------------------------------------------------- 14
5. Event Log --------------------------------------------------------------------------------------- 15
6. Download Code --------------------------------------------------------------------------------------- 15
6.1 Programming the Panel ------------------------------------------------------------------------------------ 15
6.2 Location Values ---------------------------------------------------------------------------------------------- 15
7. Programming the Panel --------------------------------------------------------------------------------- 16
7.1 Entering Program Mode ----------------------------------------------------------------------------------- 17
7.2 Programming Standard Locations ---------------------------------------------------------------------- 17
7.3 Programming Extended Locations ---------------------------------------------------------------------- 17
7.4 Programming a Bitmapped Location ------------------------------------------------------------------- 18
7.5 Incorrect Data Entries -------------------------------------------------------------------------------------- 18
7.6 Programming Location Summary ----------------------------------------------------------------------- 18
7.6.1 Zone Options ------------------------------------------------------------------------------------------------- 19
7.6.2 System Options ---------------------------------------------------------------------------------------------- 23
8. System Reporting Codes (4 x 2 and Domestic) ------------------------------------------------ 28
9. System Programmable Outputs ---------------------------------------------------------------------- 30
10. System Clock Options ----------------------------------------------------------------------------------- 32
11. Communicator Options --------------------------------------------------------------------------------- 34
11.1 Programming Telephone Numbers --------------------------------------------------------------------- 40
11.2 Telephone Number Storage Locations ----------------------------------------------------------------- 41
11.3 Download Options ------------------------------------------------------------------------------------------ 41
12. Partition Setup --------------------------------------------------------------------------------------- 42
13. User Options --------------------------------------------------------------------------------------- 48
Page 4
IDS 816 700-283-02I Issued September 2009
4
14. Programmable Output Options----------------------------------------------------------------------- 49
15. Keypad Options --------------------------------------------------------------------------------------- 51
16. Installer Options --------------------------------------------------------------------------------------- 52
Index of Programming Locations ------------------------------------------------------------------------------ 53
Index --------------------------------------------------------------------------------------- 56
Page 5
IDS 816 700-283-02I Issued September 2009
5
Figures
Figure 1 : Connection Diagram without Tamper per Zone -------------------------------------------- 9
Figure 2 : Tamper by Zone Connection --------------------------------------------------------------------- 10
Figure 3 : Zone Doubling Connection ----------------------------------------------------------------------- 11
Figure 4 : Resistors (Tamper per Zone or Zone Doubling) ------------------------------------------ 11
Figure 5 : Programmable Output Configuration --------------------------------------------------------- 12
Figure 6 : Fire Detect Output Sequence -------------------------------------------------------------------- 32
Tables
Table 1 : Values Represented by Each Zone LED ------------------------------------------------------- 16
Table 2 : Hexadecimal Value ----------------------------------------------------------------------------------- 17
Table 3 : Location / Zone Defaults ---------------------------------------------------------------------------- 19
Table 4 : Programmable Zone Types ------------------------------------------------------------------------ 20
Table 5 : Programmable Output Numbering -------------------------------------------------------------- 30
Table 6 : Output Actions--------------------------------------------------------------------------- --------- ----30
Table 7 : Event Driven Programmable Outputs ---------------------------------------------------------- 31
Table 8 : Function Driven Programmable Outputs ------------------------------------------------------ 31
Table 9 : Value for Day of the Week -------------------------------------------------------------------------- 33
Table 10 : Standard Contact ID Reporting Codes ------------------------------------------------------- 37
Table 11 : User Code Locations -------------------------------------------------------------------------------- 48
Page 6
IDS 816 700-283-02I Issued September 2009
6
Page 7
IDS 816 700-283-02I Issued September 2009
7
Page 8
IDS 816 700-283-02I Issued September 2009
8
1. Introduction to the IDS 816
The IDS 816 is a versatile, microprocessor based eight zone Alarm Panel. It has two partitions and can be expanded to sixteen zones. Most features are optional and may be programmed either directly through the keypads or via the telephone system, using the IDS download software and appropriate modem.
There are eight programmable burglary zones, a dedicated panic zone, monitored siren output, auxiliary power outputs and five programmable outputs, which may be programmed to perform various, trigger/switching functions.
For correct operation, the IDS 816 must be used in conjunction with the specified transformer/battery combination and appropriate peripheral sensors and signalling devices.
1.1 Features of the IDS 816
Eight programmable, end-of-line supervised zone inputs Expandable to sixteen zones via keypad zones, zone expander module, zone doubling or
wireless expansion.
2 partitions Optional tamper reporting per zone using double end-of-line resistors (12K and 4K7) Fully programmable digital telephone communicator that supports most industry standard
formats.
Five programmable outputs on alarm panel. Expandable to seven when using Wired Zone
Expander module.
Non volatile EEPROM memory retains all program and event log data in the event of a total power
failure
Programmable loop response time Up and downloadable using IDS Windows based software, either directly via RS 232 or remotely
using a modem.
Excellent protection against lightning (provided by specialised “zap tracking” and transient
suppressors)
Auto arm/disarm capability per partition and by day of the week. The panel can be programmed
to arm/disarm at a pre-determined time
Fax defeat/answering machine override Dual reporting provides for duplicated reporting to two independent central base stations.  Dynamic battery self test Low battery cut out circuit
Page 9
IDS 816 700-283-02I Issued September 2009
9
2. Installation and Wiring
Please refer to Figure 1: Connection Diagram and familiarise yourself with the following sections.
Figure 1 : Connection Diagram without Tamper per Zone
Page 10
IDS 816 700-283-02I Issued September 2009
10
2.1 Additional Technical Data
A suitable transformer with an output voltage of 16 volts AC ±10% with a 16VA minimum rating
must be used. A 32 VA transformer is recommended for larger installations.
A 12V sealed lead acid battery with a minimum capacity of 7AH must be used. The back up
period after mains failure will depend on the number of keypads, sensors and peripheral devices connected to the system.
The panel can supply a total continuous current of 750mA to peripheral devices such as keypads,
remotes, receivers, passives etc.
Connect a 12-volt self-driven siren or piezo siren [not a horn speaker] to the siren output.
2.2 End-of-Line Resistors
(Including Tamper by Zone / Zone Doubling)
All zones must be end-of-line supervised. Any unused zones must be terminated with a 3K3 resistor. The end of line resistor must be
placed inside or as close to the sensor as possible.
If neither zone doubling nor tamper by zone are required the 3K3 resistor must be used. For zone doubling or tamper per zone, the 4K7 and 12K end-of-line resistors must be connected
as per Figures 2 and 3.
Figure 2 : Tamper by Zone Connection
Tamper operation is as follows:
If the panel is unarmed and a tamper condition occurs, the siren will not sound but a tamper
condition will be reported.
If the panel is armed and a tamper condition occurs an audible alarm will register and a tamper
condition AND zone violation will be reported.
Panic zones always register panic and tamper conditions. The colour codes for the 12K and 4K7 resistors are as per in Figure 4.
Page 11
IDS 816 700-283-02I Issued September 2009
11
Figure 3 : Zone Doubling Connection
The following limitations apply to zone doubling:
1. Only normally closed contacts (n/c) may be used.
2. If the zone input to the panel is short or open circuited at the panel, both the zone and its double
will be violated.
3. If the 12K resistor is “open circuited” the primary zone will indicate a violation i.e. assuming zone
8 is doubled in this case zone 8 will be indicated as violated.
4. If the 4K7 resistor is “open circuited” the secondary zone will indicate a violation i.e. assuming the
example in 3 above zone 16 would indicate the violation.
5. The colour codes for the 4K7 and 12K resistors are shown in Figure 4.
Figure 4 : Resistors (Tamper per Zone or Zone Doubling)
Page 12
IDS 816 700-283-02I Issued September 2009
12
2.3 Box Tamper Input
The box tamper input does not require an end-of-line resistor and requires a normally closed contact.
2.4 Installing an Expander Module
When installing an expander module refer to the document supplied with the module. Note that only one (8-zone) expansion module may be added to the IDS 816 Alarm Panels.
2.5 Connecting the Telephone Communicator
Refer to Figure 1. Connection Diagram (Page 9).
For optimum lightning protection, connect a low impedance earth to the communicator earth input. Always connect the telephone communicator in line seizure mode and never in parallel with the telephone. Ensure the telephone receiver is connected to the communicator terminals marked “phone” and the incoming line to the terminals marked “line”.
2.6 Programmable Outputs
A relay board must be used when any device requiring a high current is connected to a programmable
output. The programmable output circuitry consists of a 12-volt source with a 56
series resistor.
Current sink is via a 1 000
resistor to negative. For information purposes, the output circuitry for a
single output is shown in Figure 5.
Figure 5 : Programmable Output Configuration
2.7 Key-switch or Remote Control Unit
A momentary key-switch or non-latching remote control receiver may be connected to any zone to allow remote arm/disarm and remote panic capability.
When using a key-switch or remote control unit a 3K3 resistor must be connected between the
zone input and ground.
Page 13
IDS 816 700-283-02I Issued September 2009
13
Use only a spring-loaded momentary key-switch or non-latching remote control unit.
2.8 IDS Remote Receiver
An IDS Remote Receiver (P/N 860-07-002DI) may be connected to the keypad bus. Using this facility allows remote arming and disarming of the panel while providing user identification for a maximum of 32 remotes.
2.9 Radio Transmitter Connection
When connecting a radio transmitter, use the TX terminal provided on the PCB to supply power to the transmitter. (Figure 1) The 4 Amp battery fuse protects this output.
3. Hardware Reset Switch
Should the need arise to return the panel to factory default, use the hardware reset switch (Figure 1).
The panel may be defaulted as follows:
Remove both battery and AC power from the panel. While depressing the reset switch reapply power to the panel by either connecting the battery or the AC power. Release the reset switch approximately 2 seconds after reapplying the power. Factory default values will now be restored to all locations and all attached keypad IDs will be defaulted. A default event will be logged and the existing event log will NOT be erased.
NOTE:
If reset switch has been disabled by programming a 10 into location 444, it will no longer be possible to default the panel using the reset switch. The panel can only be defaulted if a valid installer code is entered and a value of [0] is entered into location 0.
4. Enrolling Keypads and Other Devices
A new panel supplied from the factory will have factory default values in all locations (as indicated throughout this manual). Similarly new keypads will have no ID assigned to them. It is however good practice to default the system by using the reset switch prior to commencement of programming. This will ensure that the above is true and that no factory test values remain.
The keypad(s) attached to a system as defaulted above will have no ID and will therefore not
communicate with the panel. This is indicated by all keypad LED’s flashing simultaneously.
In order to enrol a keypad (thereby giving the keypad an ID) press the [#] key of the keypad
you wish to enrol. The enrolled keypad will now indicate the alarm status. Repeat this process with the remaining keypads where more than 1 keypad is used. The first keypad enrolled will have an ID of 1, the second enrolled will have an ID of 2, the third an ID of 3 etc. A maximum of 8 keypads may be used. (The [P] and [M] keys can be used to scroll up and down trough the menu functions).
NOTE:
If the keypad zone is to be used, consideration must be given to the sequence in which keypads are enrolled as this affects the LED zone designation. The keypad 1 will contain zone 16, keypad 2 will contain zone 15 etc. as per section 14 in this manual.
Page 14
IDS 816 700-283-02I Issued September 2009
14
To enrol other devices (IDS Remote Receivers or Zone Expanders); consult the installation instructions for those devices. The IDS 816 Alarm Panels can only accept one zone expander and/or one IDS Remote Receiver.
4.1 Replacing a Faulty Keypad/Device
NOTE: Should a faulty keypad be REPLACED with another keypad, the following applies:
1. Disconnect ONLY the faulty keypad.
2. Program a value 4 into location zero to free up all vacant addresses.
3. Connect the replacement keypad and enrol it - by pressing [#] – it will now be enrolled in the first
available address, which should now be the address just freed up in step 2.
NOTE:
If other devices (keypads) are disconnected (or faulty), at the time of performing step 2, their addresses will also be freed. Any new devices being enrolled will automatically be allocated addresses beginning from the lowest free address. This can cause devices to be associated with the wrong addresses/partitions. The resultant communications attempts made to the wrong addresses can result in sluggish system behaviour. Operation will become confusing.
Check
After enrolling a keypad, go to location 446 to check the keypad’s ID (which is a number that corresponds to the order that the keypads were enrolled). If the keypad ID is incorrect (2
nd
keypad has ID
= 3, for example), then this must be rectified for the system is to operate correctly.
Solution
If the system is complex and has developed a keypad allocation problem, it is recommended that all keypads are defaulted and registered “from scratch”, as it were, in the correct, required sequence.
To re-enrol a zone expander, or an IDS Remote Receiver, consult the installation instructions for the relevant device.
4.2 Defaulting Keypads
To default the ID of an individual keypad:
Power off, Hold [1] & [3], Restore power, Release [1] & [3]
1. Remove power to the keypad (or the whole panel if easier). Whilst holding down the [1] and [3]
keys restore the power to the keypad.
2. All the keypad LED’s will flash simultaneously indicating that the keypad has now been de-
registered.
3. The ID of any (correctly registered) keypad can be interrogated by viewing the data in location
446 from the keypad of interest.
4. Wait for five seconds and then press the hash [#] key to allocate a new ID to the defaulted
keypad. Keypad IDs are allocated incrementally.
To default the ID of ALL keypads:
Programming a value of [3] into location [0] causes ALL keypads to be defaulted.
Page 15
IDS 816 700-283-02I Issued September 2009
15
[INSTALLER CODE] [*] [0] [*] [3] [*]
On pressing the final [*], wait a few seconds and ALL the keypads will begin flashing. (Do NOT press [#] at the end of this sequence, unless you wish the keypad you are using to be registered in the first address)
Re-enrol all keypads by pressing [#] on each keypad – in the CORRECT sequence to ensure that keypad zone and partition allocation is as required by the user.
5. Event Log
A comprehensive log of the 500 most recent events is retained in the non-volatile EEPROM. The log may be retrieved using the up/ download software. Alternatively, it can be viewed using an LCD keypad. (See LCD Keypad Manual)
6. Download Code
The download code (in conjunction with the installer code) is required for download access. The default download code is 9999. Using the downloading software, it is possible to program a location that will either allow or disallow defaulting of the download code.
This location is only accessible using the download software. If the panel is defaulted, the download code will revert back to 9999. A value of [1] [0] programmed into this location will prevent the download code from being defaulted when defaulting the panel.
6.1 Programming the Panel
The panel can be programmed either via a keypad or via the up/ download software. Programming the panel by means of an LED keypad is explained below:
NOTE: Before commencing programming, it is advisable to read the Installer Manual thoroughly.
6.2 Location Values
All values within a program location will be displayed by the zone indicators in binary coded decimal format i.e. zone indicators 1-4 indicate units (1’s) and zone indicator 5-8 indicate tens (10’s), and so on.
To read a binary value on the keypad sum the values represented by each LED that is on, as shown in Table 1.
Page 16
IDS 816 700-283-02I Issued September 2009
16
Table 1 : Values Represented by Each Zone LED
Zone LED
Value
Digit
Zone LED
Value
Digit
Zone 1 1
Units
Zone 9 1
Hundreds
Zone 2 2 Zone 10 2 Zone 3 4 Zone 11 4
Zone 4
8
Zone 12
8
Zone 5
1
Tens
Zone 13
1
Thousands
Zone 6
2
Zone 14
2
Zone 7 4 Zone 15 4 Zone 8 8 Zone 16 8
Example:
Assume the following zone indicators are on:
Zone 1, Zone 3 and Zone 5.
Units are represented by the sum of Zone 1 and Zone 3 (i.e. 1 + 4) and tens of units are represented by the value of Zone 5 (i.e. 1)
Thus, the value indicated by the LED’s that are on will be shown below.
Zone LED
Value
Digit
Zone 1 1
Units
Zone 2
2
Zone 3
4
Zone 4
4
Zone 5 1
Tens
Zone 6 2 Zone 7 4 Zone 8 8
Therefore, the displayed value is 15.
7. Programming the Panel
For all programming procedures, the [*] star key functions as the <ENTER> key and the [#] hash key functions as a <CLEAR> or an <EXIT> program key.
Invalid data entries are indicated by means of an error beep consisting of 3 short beeps of the keypad buzzer.
There are two location categories:
Standard locations which are single tiered and do not contain any sub-locations. Extended locations, which are double tiered and have sub-locations.
Both standard and extended locations may contain further subcategories referred to as bitmapped locations. For both main categories, clear visual keypad prompts are provided which aid the programming process.
Page 17
IDS 816 700-283-02I Issued September 2009
17
To read the data stored in multi-digit locations (e.g. a telephone number, account codes, etc.), enter the location. Upon initial entry into the location, the zone indicators will display the first digit. Pressing the [Panic] key will cause the next digit within the location to be displayed.
Where a hexadecimal number must be programmed, use the [MODE] key as per Table 2 below:
Table 2 : Hexadecimal Value
Hex Value
Decimal Value
Key Strokes
A 10 [MODE] key then [0] key B 11 [MODE] key then [1] key C 12 [MODE] key then [2] key D 13 [MODE] key then [3] key E 14 [MODE] key then [4] key F 15 [MODE] key then [5] key
7.1 Entering Program Mode
1. Ensure that all partitions are unarmed.
2. Press the [#] hash key followed by the [INSTALLER CODE].
3. The default installer code is 9999 or alternatively 999999 should a six digit default installer code
have been used.
4. Press the [*] star key and a long beep will confirm entry into program mode. If a correct code
has been entered, the green READY indicator will flash.
7.2 Programming Standard Locations
1. Ensure the panel is in program mode - the READY indicator will be flashing.
2. Enter the [LOCATION NUMBER] of the program location you wish to view or change.
3. Press the [*] star key. The READY indicator will continue flashing and the AWAY indicator will
come on.
4. The zone LED’s will display the data stored in the program location in binary format.
5. Enter the [NEW DATA] followed by the [*] star key. A long beep will indicate a valid entry and the
AWAY indicator will turn off.
6. If you do not wish to change the data, press the [#] key. The READY indicator will continue
flashing and the AWAY indicator will turn off.
7. Repeat steps 2 - 6 until all the necessary locations have been programmed.
8. Press the [#] hash key to exit program mode.
9. The READY indicator will stop flashing and the panel will return to the standby mode.
7.3 Programming Extended Locations
1. Ensure that the panel is in program mode - the READY indicator will be flashing.
2. Enter the [LOCATION NUMBER] of the program location that you wish to view or change.
3. Press the [*] star key. The READY indicator will continue flashing and the ARMED indicator will
come on.
4. Enter the [SUB-LOCATION NUMBER] for the program location that you wish to view or change.
5. Press the [*] star key, a long beep indicates a valid data entry. The READY indicator will continue
flashing and the ARMED and AWAY indicators will come on.
6. Enter the [NEW DATA] followed by the [*] star key. A long beep will indicate a valid entry. The
AWAY indicator will turn off.
Page 18
IDS 816 700-283-02I Issued September 2009
18
7. If you do not wish to change the data within this sub-location, press the [#] hash key. The
READY indicator will continue flashing and the AWAY indicator will turn off.
8. Repeat steps 4 to 7 until all sub-locations at the current location have been programmed as
required.
9. Press the hash [#] key to exit from the current location, the ARMED LED will turn off and the
READY indicator will continue flashing.
10. Repeat steps 2 to 9 until all locations, and their sub-locations, have been programmed as
required.
11. Press the [#] hash key again to exit from program mode (READY LED will stop flashing).
7.4 Programming a Bitmapped Location
1. A bitmapped location allows the installer to program multiple panel features within a single
location or sub-location. This is achieved using the individual zone LED’s to indicate which features are enabled or disabled.
2. By referring to the appropriate location reference tables, the installer can view the entire selection
of features associated with that location.
3. A zone LED that is on indicates that a feature is enabled. A LED that is off indicates that a feature
is disabled.
4. The installer is able to toggle a selected LED indicator ON or OFF by entering the corresponding
number followed by the [*] star key
5. Once a complete selection of features has been finalised, press the [#] key to leave the
location/sub-location with the state as indicated by the LED.
Example:
Location 40 allows the installer to select up to twelve trouble conditions which may be displayed. By default, only AC fail and low battery trouble conditions are enabled.
Entering program mode and viewing the contents of Location 40 it will be noted that the zone 1 and zone 5 LED’s will be on. All other zone LED indicators will be turn off.
To enable the Comms Fail Trouble Display (indicated by zone 2 LED) press the [2] key followed by the [*] star key. A long beep will indicate a valid entry and the zone 2 LED will come on indicating that Comms Fail Trouble Display has been enabled.
Continue selection (or de-selection) of the desired trouble conditions. Once a final selection has been made press the [#] hash key to exit the location. The AWAY indicator will turn off and a long beep will indicate acceptance of a valid data entry.
7.5 Incorrect Data Entries
1. When programming either standard or extended locations any attempt to enter invalid data will
result in an error beep (3 short beeps)
2. In the case of standard locations, the AWAY indicator will remain on after the error beeps. Re-
enter the correct data. There is no need to press the [#] hash key.
3. In the case of extended locations, the AWAY and ARMED indicators will remain on after the error
beeps. Re-enter the correct data. There is no need to press the [#] key.
7.6 Programming Location Summary
A detailed description of each location and its options follows.
Page 19
IDS 816 700-283-02I Issued September 2009
19
LOCATION 0 Defaulting of the Panel or Master User Code
Value
Action
0
Will reset all locations to the factory default values. (Master User Code 1234) and all keypad IDs will be defaulted.
1
Will default the master user code to 1234
- or 123456 if 6 digits are being used.
Master user code properties will also be defaulted. 2 Defaults ALL users 3 Defaults ALL keypads
4
Remove Missing Devices
A missing device (keypads, for example), will have its address freed up, making
its address available for a new device when it is enrolled. This MUST be done
when replacing a faulty device – see “Enrolling Keypads and other Devices”,
page 13.
7.6.1 Zone Options
LOCATIONS 1 - 16 Individual Zone Setup
Sub-location 1 Zone type
The first sub-locations of program locations 1 - 16 are used to define the zone characteristics of each of the sixteen zones. There are 13 zone types. Table 3 provides a location/zone cross-reference together with the default zone characteristics.
Table 3 : Location / Zone Defaults
Zone
Location
Sub-location 1 Default
Zone Type
1 1 1 Entry / Exit 2 2 2 Follower
3
3
4
Audible Instant
4 4 4 Audible Instant 5 5 4 Audible Instant 6 6 4 Audible Instant 7 7 4 Audible Instant 8 8 4 Audible Instant
9 9 0 Disabled 10 10 0 Disabled 11 11 0 Disabled 12 12 0 Disabled 13 13 0 Disabled
14
14 0 Disabled
15 15 0 Disabled 16 16 0 Disabled
Table 4 provides a complete list of the different zone types together with a description of their characteristics.
Page 20
IDS 816 700-283-02I Issued September 2009
20
Table 4 : Programmable Zone Types
Value
Zone Type
0
DISABLED
A Zone violation of a disabled zone is ignored by the control panel and will not be indicated on the keypad.
1
PRIMARY ENTRY / EXIT ZONE
Violations of an Entry/Exit zone are ignored during the exit delay period of the arming procedure. Violating an Entry/Exit zone when armed will initiate the entry delay. If valid User
Code is not entered before the entry delay period expires, an alarm condition will be registered. Failure to exit through an Entry/Exit zone after arming will cause the panel to Stay Arm. This zone may also function as an Entry/Exit zone that is COMMON to two partitions. In such a case, should a user violate this zone and then disarm his partition, the OTHER partition will re­arm after the entry delay.
8
SECONDARY ENTRY / EXIT ZONE
The secondary entry delay will be activated if this zone is violated when the panel is armed.
2
FOLLOWER ZONE
A violation of a Follower zone is ignored during the entry/exit delay period (this allows the user to enter/exit via the Follower zone). A Follower zone will behave as an instant zone if the panel is armed and an Entry/Exit zone is not violated prior to violation of the follower zone.
3
PANIC / PRIORITY ZONE
Regardless of whether the panel is armed or not, a violation of a Priority zone will cause the
control panel to register a panic condition. This zone type CANNOT be bypassed.
4
INSTANT ZONE
When the panel is armed the violation of an instant zone will cause the control panel to register an alarm condition.
5
ARM/DISARM ZONE
The violation of an Arm/Disarm zone will cause the panel to toggle between (away) armed and disarmed. It is typical to connect a momentary key-switch, or non-latching remote control unit to this zone.
9 RESERVED
10
FIRE ZONE
Violation of a Fire zone will cause the siren to sound regardless of whether the panel is armed or not. The siren will sound intermittently (one second on, one second off) For correct operation a programmable output programmed as a fire detector power output must be used to control power to the fire detector. There is a 10 second violation when unarmed and instant when armed.
11
TAMPER ZONE
Violation of this zone will be reported to the base station regardless of whether the panel is armed or disarmed. If the panel is armed, the siren will be activated.
12
24 HOUR ALARM ZONE
This works the same as a panic zone – with the exception that it can be bypassed.
13
WARNING ZONE
When the panel is armed, violation of a warning zone will cause the siren to beep. The violation is logged in the event log but it is not reported to the base station. Warning zones may be included and will be counted when used as part of the cross-zone matrix.
14
PUSH TO ARM ZONE
Violation of a push to arm zone during the exit delay will immediately arm the panel.
15
OUTDOOR INSTANT ZONE
When the panel is armed violation of an outdoor instant zone will cause the panel to register an alarm condition.
Page 21
IDS 816 700-283-02I Issued September 2009
21
Sub-location 2 Zone Properties
NOTE: Select all the options for each zone. Shaded areas in the table indicate default values. This is a bitmapped location.
LED
ON / OFF
Zone Properties
1
ON Tamper by zone enabled
OFF Tamper by zone disabled
2
ON Cross-zone enabled
OFF Cross-zone disabled
3
ON Shutdown zone enabled
OFF Shutdown zone disabled
4
ON Silent zone enabled
OFF Silent zone disabled
Default values are shaded
Further zone related functionality explained
Tamper by Zone
Individual zones may be enabled for tamper by zone. For connection details, see Figure 2. This feature is not available if zone doubling is enabled. (Figure 3, page 11 and location 38, page 24)
Cross-zoning
This feature is useful for reducing false alarms. Violating zones with the cross-zone property enabled will not immediately generate an alarm. The cross-zone delay timer is started. (location 36).
Depending on the value programmed into location 37 (Cross-zone Trip Count), the zone (or any other zone with cross-zone option enabled) must trip the number of times programmed into location 37 before an alarm is generated. An alarm will also be generated should any single zone remain violated for the entire delay period (location 36). An entry/exit cannot be cross-zoned.
Swinger Shutdown
During a single arm cycle, if the number of alarm violations generated by a swinger zone equals the shutdown count (location 33), the control panel will automatically bypass the zone. The swinger shutdown counter will reset when the system is disarmed and can be programmed to reset automatically when the 24 hour self test report is generated. (Sub-location 5 of locations 128 and 129).
Silent Zone
This property allows any zone that would ordinarily activate the siren to be programmed as a silent zone i.e. the violation of a silent zone while the system is armed will not activate the siren. However, the relevant reporting code (if programmed) will still be reported.
Zone Reporting Codes
NOTE:
For the following locations, a two digit hexadecimal code must be programmed. To disable a reporting code a double zero (00) must be entered. If a zero is to be reported, it must be entered as hexadecimal value A, i.e. [MODE] [0]. In the event that only 1 of the digits is programmed or an A is incorrectly programmed as a zero the code will not be reported. If domestic reporting is used, only the first digit of the reporting code is required / used.
Page 22
IDS 816 700-283-02I Issued September 2009
22
Sub-location 3 Alarm Reporting Code
This is the code transmitted when the zone is violated during an arm cycle or if a panic or 24 Hour Zone is violated.
Sub -location 4 Alarm Restoral Reporting Code
The zone restoral code is transmitted when the zone has returned to the “unviolated” condition after triggering an alarm.
Sub-location 5 Bypass Reporting Code
A zone bypass code will be reported when a zone has been bypassed and the panel is armed.
Sub-location 6 Force Arm Reporting Code
This code will be transmitted if a partition is programmed to allow forced arming (arming with a violated zone) and a zone is violated at the time of arming.
Sub-location 7 Tamper Reporting Code
The tamper code will be reported if tamper-by-zone has been enabled and a zone tamper occurs.
Sub-location 8 Tamper Restore Reporting Code
When a zone tamper condition clears, this code will be reported.
Sub-location 9 Swinger Shutdown Reporting Code
The swinger shutdown zone code will be reported if the system is armed and a zone is automatically bypassed as a result of multiple violations of that zone.
Sub-location 10 Swinger Shutdown Restore Reporting Code
If enabled, this code will be reported when a swinger shutdown zone is automatically restored i.e. un­bypassed.
Sub-location 11 Zone Programmable Output Location
A programmable output will be pulsed or latched, high or low if a zone causes an alarm condition. If pulsed, the output will be pulsed for the time programmed in sub-location 1 of locations 388 - 394.
Two digits must be programmed for each zone. The first digit references the programmable output number e.g. output 1 to 5 (7 with an expander). The second digit sets the output action. Refer
System Programmable Outputs” (Page 30) for a detailed description on Programming Programmable
Outputs.
Sub-location 12 Zone Name Editing (LCD keypads only)
Zones may be given appropriate names, like “Front Door” for zone 1, etc. When the zone is triggered, the display will indicate “Front Door”, instead of “Zone 1”. (Full instructions are included in the LCD keypad manual.)
Page 23
IDS 816 700-283-02I Issued September 2009
23
7.6.2 System Options
LOCATION 33 Zone Shutdown Count (Default = 5)
Determines the number of times a zone may be violated during an arm cycle before it is automatically bypassed. Select zones individually for this option in locations 1 – 16 (sub-location 2). Valid range of data for this location is 1 to 15.
LOCATION 34 Programmable Zone Loop Response Time
The following applies when option 4 in location 38, is ON
Value
Response Time
Value
Response Time
0
6 ms
8
96 ms
1 12 ms
9 108 ms
2 24 ms (default)
10 120 ms
3 36 ms
11 132 ms
4
48 ms
12
144 ms
5 60 ms
13 156 ms
6 72 ms
14 168 ms
7
48 ms
15
180 ms
The zone loop response is the period of time for which the programmed zone must remain violated before a violation is registered. By default, this table is ignored and a Fixed Zone Loop Response of 100ms is used.
LOCATION 35 Reserved
LOCATION 36 Cross-zone Delay Timer
This location defines the cross-zone delay timer period.
Value
Response Time
0 3 seconds 1 10 seconds 2 15 seconds 3 20 seconds (default) 4 25 seconds 5 30 seconds 6 45 seconds 7 1 Minute
LOCATION 37
Cross-zone Count (Default = 2)
If the panel is armed and the total number of violations of zones programmed as cross-zones reaches this count within the time period programmed into location 36, an alarm condition will be registered. Program a value from [0] to [1] [5]. A [0] will disable this location. Program zones as cross-zones in sub­location 2 of locations 1 to 16. Any single zone enabled for cross-zoning, which is violated continuously for the time specified in location 36 will also register an alarm condition.
Page 24
IDS 816 700-283-02I Issued September 2009
24
LOCATION 38 Global Options
LED
ON / OFF
Action
1
ON
A user assigned to any partition may cancel the siren
OFF
Only a user assigned to the partition that triggered the siren may cancel the siren
2
ON
Enables keypad trouble beep
OFF
Disables keypad trouble beep
3
ON
Enables telephone line monitoring
OFF
Disables telephone line monitoring
4
ON
Enables use of programmable loop response time
OFF
Standard 100ms loop response time
5
ON
Enables keypad beep on communication
OFF
Disables keypad beep on communication
6
ON
Enables keypad fire, medical and panic keys
OFF
Disables keypad fire, medical and panic keys
7
ON
Enables the display of bypassed and stay zones when armed in the stay
mode
OFF
Disables the display of bypassed and stay zones when armed in the stay
mode
8
ON
Enables the siren delay
OFF
Disables the siren delay
9
ON
Enables zone doubling
OFF
Disables zone doubling (expansion / keypad zones can be used to expand the system to sixteen zones.)
10
ON
Enable box tamper
OFF
Disable box tamper
11
ON
Enable siren tamper
OFF
Disable siren tamper
12
ON
Enable 485 device tamper
OFF
Disable 485 device tamper
13
ON
Dedicated panic zone – silent
OFF
Dedicated panic zone – audible
Default values are shaded
Page 25
IDS 816 700-283-02I Issued September 2009
25
LOCATION 39 AC Fail / Restore Time
Value
Delay
0 3 seconds 1 10 seconds 2 15 seconds 3 20 seconds
4
25 seconds
5
30 seconds
6 45 seconds 7 1 minute 8 2 minutes
9 3 minutes 10 4 minutes 11 5 minutes 12 10 minutes 13 15 minutes 14 18 minutes
15
21 minutes
16
1 hour
17 2 hours 18 3 hours 19 4 hours 20 10 hours
In the event of a power failure the panel will display an instant trouble, but will wait for this period of time before REPORTING the mains failure. The same time period applies before the restoral event is reported and logged. This delay eliminates unnecessary reporting if the AC power is removed for a short time period.
It is important to note that an AC restoral will only be reported if an AC failure was reported, i.e. the delay period was exceeded. Provided the back up battery is in good condition, short AC power failures will not affect the functioning of the alarm system. Select the appropriate value from the table above.
Page 26
IDS 816 700-283-02I Issued September 2009
26
LOCATION 40 Trouble Display
LED
ON/ OFF
Action
1
ON
Enable AC fail trouble display
OFF
Disable AC fail trouble display
2
ON
Enable Comms fail trouble display
OFF
Disable Comms fail trouble display
3
ON
Enable phone line trouble display
OFF
Disable phone line trouble display
4
ON
Enable siren tamper trouble display
OFF
Disable siren tamper trouble display
5
ON
Enable low battery detection trouble display
OFF
Disable low battery detection trouble display
6
ON
Enable clock loss trouble display
OFF
Disable clock loss trouble display
7
ON
Enable engineers reset trouble display
OFF
Disable engineers reset trouble display
8
ON
Enable box tamper trouble display
OFF
Disable box tamper trouble display
9
ON
Reserved
OFF
Reserved
10
ON
Enable 485 device trouble display
OFF
Disable 485 device trouble display
11
ON
Enable bus trouble display
OFF
Disable bus trouble display
12
ON
Enable Aux. 12V trouble display
OFF
Disable Aux. 12V trouble display
13
ON
Reserved
OFF
Reserved
Default values are shaded
Location 40 determines which trouble conditions are displayed on the trouble menu. A trouble condition is indicated by a flashing POWER LED. Not withstanding the disabling of a trouble condition from the viewing menu the relevant code will be reported if programmed to do so. Trouble conditions will be reported if programmed to do so in locations 118 to 120, regardless of whether or not they are enabled for display.
The trouble condition can be viewed by holding down the [7] key for one second. See “Viewing Trouble Conditions” in the User Manual.
Page 27
IDS 816 700-283-02I Issued September 2009
27
LOCATION 41 Siren Time Out Period
Value
Delay
0 3 seconds 1 10 seconds 2 15 seconds 3 20 seconds 4 25 seconds 5 30 seconds 6 45 seconds 7 1 minute 8 2 minutes
9
3 minutes
10
4 minutes
11 5 minutes 12 10 minutes 13 15 minutes 14 18 minutes 15 21 minutes
The siren time out period is the period of time for which the siren will sound after an audible alarm condition is registered. Select the appropriate time period from the table above.
LOCATION 42 Siren Delay
When an audible alarm is registered, a delay can be implemented before the siren is triggered. The alarm will however be reported as soon as it occurs. Enable option 8, location 38.
Value
Delay
0 3 seconds 1 10 seconds 2 15 seconds 3 20 seconds
4
25 seconds
5
30 seconds
6 45 seconds 7 1 minute 8 2 minutes
9 3 minutes 10 4 minutes 11 5 minutes 12 10 minutes 13 15 minutes 14 18 minutes
15
21 minutes
LOCATION 43 Keypad Lockout Count (Default = 4 seconds)
If a partition has keypad lockout enabled (Page 46) this value determines the number of consecutive incorrect codes, which will activate a keypad lockout. The keypad will remain locked for the time programmed in location 44. Activating a Keypad Panic will unlock the keypad.
Page 28
IDS 816 700-283-02I Issued September 2009
28
LOCATION 44 Keypad Lockout Time (Default = 30 seconds)
The value programmed into this location determines the keypad lockout period. The valid range is 0 - 255 seconds.
NOTE: Keypad lockout is enabled by partition. See Partition Options Page 44, sub-location 5.
LOCATION 45 Keypad Sleep Delay (Default = 5 seconds)
The values stored in this location work in the same way as siren delay (table on page 27). The default value is 11, which equates to 5 minutes.
NOTE: This function is set individually per keypad (locations 400 to 407). After this time period, if there is no keypad activity (on this keypad) the backlighting and all other status and alarm indicators will turn off. The power LED and if appropriate, the arm LED will remain on.
LOCATION 46 User and Installer Code Number of Digits
This location determines whether 4 or 6 digit user / installer codes are applicable. Only a value of four or six may be programmed into this location. By default, all codes are four digits in length.
The value programmed into this location has no effect on the download code, which is always 4 digits in length.
Code
Old Four-digit Code
New Six-digit Code
All Previously
Programmed Codes
XXXX XXXX00
Installer Code 9999 999999
Master User Code 1 1234 123456
8. System Reporting Codes (4 x 2 and Domestic)
For all these locations, a two digit hexadecimal code must be programmed. To disable a reporting code a double zero (00) must be entered into the corresponding location. Note that if one of the above­mentioned reporting digits is inadvertently omitted or programmed as a zero, the code will not be reported. The exception to this rule is when using domestic reporting where only the first digit is used.
LOCATION 47 AC Failure Reporting Code
The control panel will transmit this code in the event of an AC failure but only after the AC failure delay time has elapsed (location 39).
LOCATION 48 AC Restoral Code
The control panel will transmit this code once the AC restore delay time has elapsed. (location 39). It will however only be reported if an AC failure was registered as per location 47.
Page 29
IDS 816 700-283-02I Issued September 2009
29
LOCATION 49 Low Battery Reporting Code
A low battery condition is reported when the battery voltage drops below 11.8V for a period longer than 5 minutes or immediately if it drops below 10V.
LOCATION 50 Battery Restore Reporting Code
This code is reported once the battery voltage rises above 12 volts for a period of five minutes.
LOCATION 51 Auto Test Reporting Code
This code is reported at regular intervals. (location 112)
LOCATION 52 Download Access Reporting Code
This code is reported once successful access to the panel has been obtained.
LOCATION 53 Siren Trouble Reporting Code
This code is reported when the siren fuse blows or when the siren or siren wiring is tampered with.
LOCATION 56
Device Tamper Reporting Code
This code is reported when there is a tamper condition on any external device attached to the keypad bus.
LOCATION 57
Keypad Bus Failure Reporting Code
This code is reported when there is a fault on the keypad bus
LOCATION 58 Box Tamper Reporting Code
This code is reported when the box tamper contacts are open for a period exceeding 200 ms.
LOCATION 59 Dedicated Panic Reporting Code
This code is reported when the dedicated panic zone is violated.
LOCATION 60
Phone Line Restoral Reporting Code
If phone line monitoring is enabled (location 38), this code is reported once phone line integrity has been restored to indicate that the phone line has been tampered with.
LOCATION 61
RF Jamming Reporting Code
This reporting code will be reported if the RF receiver module detects a jamming signal for a period exceeding 30 seconds.
LOCATION 62
RF Jamming Restore Reporting Code
This reporting code will be reported once the jamming signal has ceased for a period exceeding 30 seconds.
Page 30
IDS 816 700-283-02I Issued September 2009
30
9. System Programmable Outputs
Programming the Outputs:
Programmable outputs are able to toggle between different states when specific system events occur. Either single or multiple events may be programmed to a particular output.
For most events the action of an output, when triggered, is programmable. To program these events a two-digit code must be entered. The output action for certain events is fixed – and function driven, the strobe function is one example. For these events, only a single digit code need be programmed.
There are five programmable outputs on the IDS 816 Alarm Panel and a further two programmable outputs on the Wired Zone Expander module. When selecting outputs, programmable outputs on the alarm panels are addressed from “1” to “5“.
Outputs on the Wired Zone Expander are addressed as “6” and “7” – (refer to table 5).
Table 5 : Programmable Output Numbering
Value
Programmed as
Output Addressed
0
[0]
No output addressed
1 [1] Panel - programmable output 1 2 [2] Panel - programmable output 2 3 [3] Panel - programmable output 3 4 [4] Panel - programmable output 4 5 [5] Panel - programmable output 5 6 [6] Zone expander - programmable output 2 7 [7] Zone expander - programmable output 1
There are 4 permitted output actions, which may be selected. These are listed below in table 6.
Table 6 : Output Actions
Value
Output Action
0 Set output high (Set) 1 Set output low (Reset) 2 Pulse output high 3 Pulse output low
When programming these outputs a two-digit code must be entered. The first digit references the programmable output number (Table 5) and the second digit references the output action (Table 6).
Example:
Entering a value of [1][0] into location 70 will cause Panel Programmable Output 1 to be set (latched) high in the event of an AC Mains Failure. Entering a value of [1][1] into location 71 will cause the Panel Programmable Output 1 to be set (latched) low in the event of an AC Mains Restoral.
When programming a programmable output whose action is fixed only a single digit need be entered. This digit references the programmable output number (Table 5).
Example:
Programming a value of [7] into sub-location 42 of location 129 will cause the Zone Expander Programmable Output 1 to follow the Siren Output for Partition 2.
Page 31
IDS 816 700-283-02I Issued September 2009
31
NOTE: When connecting any device with a high current requirement to a programmable output a suitable relay must be used. DO NOT connect such devices directly to the programmable outputs as this may damage the output circuitry.
LOCATIONS 70-87 Event Driven Programmable Outputs
Table 7 : Event Driven Programmable Outputs
Loc.
Event
Output
Default Action
70 AC fail programmable output Disabled
71
AC restore programmable output
Disabled
72
Low battery programmable output
Disabled
73 Battery restore programmable output Disabled 74 Auto test programmable output Disabled 75 Download programmable output Disabled 76 Siren trouble programmable output Disabled 77 Aux 12V trouble programmable output Disabled 78 Keypad fuse programmable output Disabled 79 485 device tamper programmable output Disabled 80 485 bus failure programmable output Disabled
81
Box tamper programmable output
Disabled
82
Dedicated panic programmable output
1
Pulse high [2]
83
Communication fail programmable output
Disabled
84 Phone line tamper programmable output Disabled 85 Phone line restore programmable output Disabled 86 RF jamming programmable output Disabled
87
RF jamming restore programmable output
Disabled
LOCATIONS 95 – 96 Function Driven Programmable Outputs
Table 8 : Function Driven Programmable Outputs
Summary of System function Driven Programmable outputs
Loc.
Function
Output
95 Fire sensor power programmable output Disabled 96 Dual reporting programmable output Disabled
Page 32
IDS 816 700-283-02I Issued September 2009
32
Figure 6 : Fire Detect Output Sequence
NOTE:
Since multiple conditions may be programmed to a single output, it is essential to ensure that no unwanted conditions are assigned to an output.
Dual Reporting Output
If dual reporting is enabled this output will be set when the panel dials the second phone number, and cleared when it hangs up at the end of transmission. This output follows the hook relay. It may be used to trigger switching from the telephone line to a radio transmitter.
10. System Clock Options
LOCATION 98 System Time
Enter the system time. The format is “hhmm” and is based on a 24-hour clock. (All 4 digits must be entered.)
LOCATION 99 System Day of Month
Enter a two-digit value of the current day of the month. Valid range 01 to 31.
LOCATION 100 System Month
Enter the month as a value from 01 to 12.
LOCATION 101 System Year
Enter the current year as a four-digit value e.g. 2007.
LOCATION 102
System Day of Week
Enter the current day of the week. Refer to table 9.
Page 33
IDS 816 700-283-02I Issued September 2009
33
Table 9 : Value for Day of the Week
Value
Day
1 Monday 2 Tuesday 3 Wednesday
4
Thursday
5
Friday
6
Saturday
7 Sunday
LOCATION 103 Month to Start Daylight Saving
Enter the month when Daylight Saving will commence.
LOCATION 104 Day of Week to Start Daylight Saving
Enter which day of the week Daylight saving is to commence. Refer to location 102 Table 9.
LOCATION 105 Week of Month to Start Daylight Saving
Enter which week of the month Daylight Saving is to commence. If the last week of the month is wanted, program a five (5).
LOCATION 106 Month to Return to Standard Time
Enter the month when Daylight Saving reverts to standard time.
LOCATION 107 Day of Week to Return to Standard Time
Enter which day of the week (Table 9) that Daylight Saving returns to standard time.
LOCATION 108
Week of Month to Return to Standard Time
Enter which week of the month Daylight Saving will return to standard time. If it is to be the last week of the month, program a five (5).
LOCATION 109 Daylight Saving Time Offset
This location is used for setting the Daylight Saving offset. Enter the number of minutes the clock will offset - Valid range 0 to 250.
Page 34
IDS 816 700-283-02I Issued September 2009
34
11. Communicator Options
LOCATION 110 Communication Delay
Value
Delay
0 3 seconds 1 10 seconds 2 15 seconds 3 20 seconds 4 25 seconds
5
30 seconds
6
45 seconds
7 1 minute 8 2 minutes
9 3 minutes 10 4 minutes 11 5 minutes 12 10 minutes 13 15 minutes 14 18 minutes 15 21 minutes
If delayed communications is enabled for either partition, (locations 128 and 129) the panel will wait for this period before reporting zone violations and restorals. If the alarm is cancelled within this time zone, violations and restorals will not be reported. Violations will however be logged in the event log. Panic events will be reported instantly – regardless of any selected delay period.
LOCATION 111
Reporting Options
LED
On / Off
Action
1
ON Tone dialling enabled
OFF Pulse dialling enabled
2
ON Join the telephone numbers together
OFF Keep two separate telephone numbers
3
ON Enable dual reporting
OFF Disable dual reporting
Single reporting options (LED 3 off)
4
ON
Reports to secondary number only after failing on attempting the primary number. (Panic event initiates dual reporting)
OFF
Alternates reporting attempts between both
numbers until successful with one of them. (Single reporting, regardless of panic)
Default values are shaded
Page 35
IDS 816 700-283-02I Issued September 2009
35
NOTE:
The panel may be programmed to report to a single central station (single reporting) or to report
to 2 central stations (dual reporting).
When programmed for single reporting, the panel default will alternate attempts between the two
“equally ranked” stored numbers. With LED 4 on, the secondary number will only be called if the attempt to report to the primary number fails. In either case, the number of attempts (per phone number) will be equal to the number stored in location 115, with a default value of 6.
The primary and secondary telephone numbers may be joined to provide for a single telephone
number of 48 digits in length.
LOCATION 112 Auto Test Interval
Value
Time Period
0 Report every hour
1
Report daily (default)
2 Every two days 3 Every three days 4 Every four days 5 Every five days 6 Every six days 7 Every seven days 8 Every eight days
9 Every nine days 10 Every ten days 11 Every eleven days
12
Every twelve days
13
Every thirteen days
14 Every fourteen days 15 Every fifteen days
The value programmed into this location will determine the duration of time between Auto Tests.
LOCATION 113 Auto Test Time
Enter the time when the auto test will be reported. The format is “hhmm” based on a 24-hour clock. (All four digits must be entered.)
Example:
If a value of [7] was programmed into location 112 and [1400] was programmed into this location, the auto test would be sent weekly at 2:00pm.
LOCATION 114 Number of Account Code Digits (Default = 4)
Most reporting formats use a 4-digit account code. Program a 6 into this location to enable 6-digit account code reporting. This option is not supported by Contact ID.
LOCATION 115 Number of Dial Attempts (Default = 6)
This location determines the maximum number of dial attempts that the panel will make in order to contact the base station.
Page 36
IDS 816 700-283-02I Issued September 2009
36
NOTE: Entering [0] into this location will disable the dialler.
LOCATION 116 Primary Communicator Format
Value
Format Name
Description
0 Ademco Express Dual Tone HS 1 FBI 4 x 2 ( With Parity) 1.8kHz TX, 2.3kHz HS, 40PPS 2 FBI 4 x 2 (No Parity) 1.8kHz TX, 2.3kHz HS, 20PPS 3 Silent Knight 4 x 2 Fast 1.9kHz TX, 1.4kHz, 20PPS 4 Silent Knight 4 x 2 Slow 1.9kHz TX, 1.4kHz, 20PPS
5 (Default) Contact ID Dual Tone HS
6 Domestic Reporting 0.5kHz TX, Blind, 20PPS
TX = Transmit HS = Handshake PPS = Pulses per Second
The value entered into location 116 selects the primary communicator format. Select from the table above the value appropriate to the required format. During communication, the green LED on the PCB will come on indicating that the panel has taken the telephone off-hook. If programmed accordingly (location 38), the keypad will beep after receiving a handshake from the base station. This indicates a successful transmission of data.
LOCATION 117 Secondary Communicator Format
If dual reporting is enabled then this format will be used to report to phone number 2. (Table for location
116.)
NOTES ON DUAL REPORTING
When dual reporting is enabled, it is possible to select two different formats. In this instance, all data will be transmitted to each phone number (i.e. reported twice) using a different format per phone number.
NOTES ON CONTACT ID
If the panel has been programmed to use the Contact ID, it will not be necessary to program individual reporting codes. Provision is made to enable/disable the reporting of certain groups of codes. (location 118 to 120). Table 10 contains a list of standard (default) Contact ID reporting codes. Any event that relates to a specific zone, or to a specific user, will have the relevant zone/user number appended to the end of the Contact ID reporting code.
Page 37
IDS 816 700-283-02I Issued September 2009
37
Table 10 : Standard Contact ID Reporting Codes
Description
Codes
Description
Codes
Keypad medical 1100 Cancel 1406 Fire 1110 Open by download 1407
Keypad Fire
1110
Open with key-switch
1409
Panic
1120
Low battery
1302
Panic zone 1120 Sounder/Relay trouble 1320 Keypad panic 1120 Expansion module fail 1333 Duress 1121 Zone/Sensor bypass 1570 Burglary violation 1130 Zone/Sensor bypass restoral 3570 Perimeter violation 1131 Burg. bypass 1573 Interior violation 1132 Test report 1602 24 Hour (safe) violation 1133 Panic restore 3120 Entry/Exit violation 1134 Zone restoral 3130 Day/night violation 1135 Keypad tamper restore 3137 Outdoor violation 1136 Zone restoral 3130
Tamper violation
1137
Sensor tamper restore
3144
Keypad tamper
1137
Expansion module tamper restore
3145
Keypad lockout 1137 RF low battery restore 3384 Near alarm violation 1138 Close by user 3401 Tamper by zone 1144 Close by auto arm 3403 Expansion module tamper 1145 Close by download 3407 Exp. module low bat 1338 Close with key-switch 3409 RF receiver jam detect 1344 Expansion module fail restore 3333 Long range transmitter fault 1353 AC loss 3321 Loss of supervision RF 1381 AC restoral 3333
RF low battery
1384
Low battery restore
3302
Open by user
1401
Sounder/Relay restore
3320
NOTES ON DOMESTIC REPORTING:
If Dual Reporting is enabled, Domestic reporting may either be reported to 2 telephone numbers or using the dual reporting option, report to a central station as well as to an individual mobile phone etc. This format provides for a simple form of easily identifiable remote alarm which may be reported to an office, mobile phone etc. A series of tones is transmitted to the phone, which notifies the user that an alarm condition has occurred. If a 1 is programmed to a location, a single beep will be heard if that particular alarm condition occurs. If a 2 is programmed to a location, 2 beeps will be heard etc.
NOTE:
If the system is armed using the quick arm key [1] the system will report a close by user 35.
If the system is armed by means of a key switch or non-latching remote receiver connected to
an arm/disarm zone the system will report a close by user 34.
Enabling / Disabling Reporting Groups
Locations 118 to 120 are used to either enable or disable the reporting of groups of reporting codes when using Contact ID.
Page 38
IDS 816 700-283-02I Issued September 2009
38
LOCATION 118 Global Group Reporting Code Enable / Disable 1
LED
ON / OFF
Action
1
ON Enable close reporting code
OFF Disable close reporting code
2
ON Enable stay close reporting code
OFF Disable stay close reporting code
3
ON
Enable open reporting code
OFF
Disable open reporting code
4
ON Enable cancel reporting code
OFF Disable cancel reporting code
5
ON Enable alarm reporting code
OFF Disable alarm reporting code
6
ON Enable restore reporting code
OFF Disable restore reporting code
7
ON Enable bypass reporting code
OFF Disable bypass reporting code
8
ON Enable force reporting code
OFF
Disable force reporting code
9
ON
Enable tamper reporting code
OFF Disable tamper reporting code
10
ON Enable tamper restore reporting code
OFF Disable tamper restore reporting code
11
ON Enable shutdown reporting code
OFF Disable shutdown reporting code
12
ON Enable shutdown restore reporting code
OFF Disable shutdown restore reporting code
13
ON Enable AC fail reporting code
OFF Disable AC fail reporting code
14
ON
Enable AC restore reporting code
OFF
Disable AC restore reporting code
15
ON Enable low battery reporting code
OFF Disable low battery reporting code
16
ON Enable battery restore reporting code
OFF Disable battery restore reporting code
Default values are shaded
Page 39
IDS 816 700-283-02I Issued September 2009
39
LOCATION 119 Global Group Reporting Code Enable / Disable 2
LED
ON / OFF
Action
1
ON Enable test report reporting code
OFF
Disable test report reporting code
2
ON
Enable download reporting code
OFF
Disable download reporting code
3
ON Enable siren fuse trouble reporting code
OFF Disable siren fuse trouble reporting code
4
ON Enable Aux. 12V trouble reporting code
OFF Disable Aux. 12V trouble reporting code
5
ON Enable keypad fuse trouble reporting code
OFF Disable keypad fuse trouble reporting code
6
ON Enable 485 device tamper reporting code
OFF Disable 485 device tamper reporting code
7
ON Enable 485 bus tamper reporting code
OFF
Disable 485 bus tamper reporting code
8
ON
Enable box tamper reporting code
OFF Disable box tamper reporting code
9
ON Enable dedicated panic reporting code
OFF Disable dedicated panic reporting code
10
ON Enable phone line restoral reporting code
OFF Disable phone line restoral reporting code
11
ON Enable duress reporting code
OFF Disable duress reporting code
12
ON Enable keypad panic reporting code
OFF Disable keypad panic reporting code
13
ON
Enable keypad fire reporting code
OFF
Disable keypad fire reporting code
14
ON Enable keypad medical reporting code
OFF Disable keypad medical reporting code
15
ON Enable keypad lockout reporting code
OFF Disable keypad lockout reporting code
16
ON Enable access reporting code
OFF Disable access reporting code
Default values are shaded
Page 40
IDS 816 700-283-02I Issued September 2009
40
LOCATION 120 Global Group Reporting Code / Disable 3
LED
ON / OFF
Action
1
ON Enable RF jamming
OFF
Disable RF jamming
2
ON
Enable RF jamming restore
OFF
Disable RF jamming restore
3
ON
RESERVED
OFF
4
ON
RESERVED
OFF
5
ON
RESERVED
OFF
6
ON
RESERVED
OFF
7
ON
RESERVED
OFF
8
ON
RESERVED
OFF
9
ON
RESERVED
OFF
Default values are shaded
11.1 Programming Telephone Numbers
For the telephone number locations, a value of [0] is used as a termination digit. It is important therefore that any zeros (0) in the telephone number itself be entered as a [10]. All hexadecimal values are entered using the mode key (See table 2, page 17).
Enter numbers consecutively with no other key presses between each digit.
To dial a “0” program a table 2 [10] – by pressing [MODE] [0] To dial a “*” program an [11] - by pressing [MODE] [1] To dial a "#" program a [12] - by pressing [MODE] [2]
Inserting pauses A pause may be inserted at any point within the telephone number: Entering a value of [13] (by pressing [MODE] [3]) will provide a 12-second pause and a value of [15] (by pressing [MODE] [5]) will provide
a 4-second pause.
To terminate a telephone number, program a [0] immediately after the last digit of the telephone number.
Example: Phone number 1 is to be dialled as follows: [0] followed by a 4 second pause then [0317051373]. The key sequences are as follows:
Page 41
IDS 816 700-283-02I Issued September 2009
41
Data entered
Explanation
[INSTALLER CODE][*] To enter program mode
[1][2][1][*] To enter location 121 (phone number 1)
[MODE][0] To dial the zero [MODE][5] This programmes the 4 second pause
[MODE][0][3][1] This programmes the area code
[7][MODE][0][5][1][3][7][3]
The remainder of the number
[0]
To mark the end of the number
[#] To exit program mode
11.2 Telephone Number Storage Locations
LOCATION 121 Phone Number 1
This location contains the primary telephone number. A maximum of 24 digits can be entered. Enter the digits consecutively and after the last digit has been entered, terminate with a [0].
LOCATION 122 Phone Number 2
This location contains the secondary telephone number. A maximum of 24 digits can be entered. Enter the digits consecutively and after the last digit has been entered, terminate with a [0].
11.3 Download Options
LOCATION 123
Download Options
LED
ON / OFF
Action
1
ON
Enable fax defeat
OFF
Disable fax defeat
2
ON
Enable forced answer
OFF Disable forced answer
3
ON Enable auto pickup
OFF Disable auto pickup
4
ON Enable call-back
OFF Disable call-back
Default values are shaded
Fax defeat is useful for downloading when a fax or answering machine is connected to the same phone line as the alarm panel. If this feature is enabled, dial the panel and hang up before three rings. Dial the panel again within one minute. The panel will then pick up the call on the first ring thereby preventing the fax / answering machine from answering the call before the alarm.
If forced answer is enabled the [8] key may be used to force the panel to go off hook,
“answering the line”.
If enabled, Auto Pickup will pick up the line after the number of rings programmed into location
124. The Call-back feature when enabled, allows the download software/PC to request that the
panel call it back using the phone number as programmed into location 125.
Page 42
IDS 816 700-283-02I Issued September 2009
42
LOCATION 124 Number of Rings to Answer (Default = 15)
This location determines the number of rings before the panel “answers" the telephone line. In the event that the panel answers the call and no valid download log on sequence is received within 40 seconds, the panel will terminate the call.
LOCATION 125
Call-back Phone Number
If Call-back is enabled in Download Options (location 123) the phone number programmed into this location will be used to respond to a call-back request from the IDS Download Software/PC.
12. Partition Setup
LOCATIONS 128 – 129 Partition Setup
Location 128 - Partition One. Location 129 - Partition Two.
Sub-location 1 Partition Zone Allocation
This location is bitmapped with each LED representing a zone. LED’s that are on represent the zones in the selected partition. Enter the number of the zone followed by the [*] key to select or deselect zones. By default, all zones are allocated to partition 1 and no zones are allocated to partition 2.
Sub-location 2 Primary Account Code
This account code is used if single reporting has been enabled. If dual reporting is enabled then this account code is reported to telephone number 1.
Sub-location 3 Secondary Account Code
This account code is only used when dual reporting is enabled. It is reported to Telephone Number 2.
Page 43
IDS 816 700-283-02I Issued September 2009
43
Sub-location 4 Partition Arm Options
LED
On / Off
ACTION
1
ON Enable instant arm
OFF Disable instant arm
2
ON Enable instant key-switch arm
OFF Disable instant key-switch arm
3
ON Enable quick arm key
OFF Disable quick arm key
4
ON
Enable quick stay arm key
OFF
Disable quick stay arm key
5
ON Enable auto stay arm if no exit zone is triggered
OFF Panel away arms regardless if zone is triggered
6
ON
Enable auto stay arm if no exit zone is triggered when arming with a key-switch (or remote)
OFF
Disable auto stay arm if no exit zone is triggered when
arming with a key-switch (or remote)
7
ON Enable forced arm
OFF Disable forced arm
8
ON
Enable zone bypassing
OFF
Disable zone bypassing
9
ON
Enable arm with zones in the entry route violated
OFF Disable arm with zones in the entry route violated
10
ON Enable siren toot on arm
OFF Disable siren toot on arm
11
ON Enable siren toot on disarm
OFF Disable siren soot on disarm
12
ON Enable the entry beep
OFF Disable the entry beep
13
ON Enable the exit beep
OFF Disable the exit beep
14
ON
Enable engineers reset
OFF
Disable engineers reset
15
ON Enable auto disarm
OFF Disable auto disarm
Default values are shaded
Quick Arm:
This option allows the user to arm the panel by holding down the [1] key for two seconds until the keypad beeps.
Force Arm:
With this option enabled, the panel will arm with violated zones e.g. an open window. When the panel arms, any violated zone is bypassed. If bypassed zones restore during the arm cycle (e.g. a window is closed), the zone is automatically re-activated (un-bypassed).
Siren Toot on Away Arm / Disarm:
This option allows the user an audible confirmation that arming or disarming of the panel has occurred. The siren can be programmed to give a short beep after successful arming, and two short beeps after disarming. This is useful when used in conjunction remote or key-switch arming/disarming.
Page 44
IDS 816 700-283-02I Issued September 2009
44
Engineer Reset:
If enabled this option prevents arming the panel after an alarm condition has occurred. The panel can only be armed after the engineer has entered a valid installer code. A trouble condition will be displayed on the keypad if enabled in location 40.
Sub-location 5 Partition Options
LED
ON / OFF
Action
1
ON
Enable automatic re-enabling of shutdown zones at the time of the dialler test.
OFF
Disable automatic re-enabling of shutdown zones at the time of the dialler test.
2
ON
Enable bypassing of common zones
OFF
Disable bypassing of common zones
3
ON Enable delay before communications
OFF Disable delay before communications
4
ON Enable keypad lockout
OFF Disable keypad lockout
5
ON Enable user phone access
OFF Disable user phone access
6
ON Enable silent keypad panic
OFF Disable silent keypad panic
Default values are shaded
Sub-location 6 Exit Delay Period
Value
Time-out Delay
Value
Time-out Delay
0 3 Seconds 8 2 Minutes 1 10 Seconds 9 3 Minutes
2
15 Seconds
10
4 Minutes
3
20 Seconds
11
5 Minutes
4 25 Seconds 12 10 Minutes 5 30 Seconds (default) 13 15 Minutes 6 45 Seconds 14 18 Minutes 7 1 Minute 15 21 Minutes
The exit delay will begin after the entry of a valid user code (or pressing of the [1] or [6], initiating the quick-arm function). During this period, it is permissible to violate Entry/Exit and Follower zones without causing an alarm condition thus allowing exit from the premises. Select the appropriate exit delay period from the table above. If an instant zone is violated during this period, an alarm condition will immediately be registered. Select the appropriate value for the primary exit delay from the table.
Sub-location 7 Primary Entry Delay Time
(Values identical to Sub-location 6) This entry delay begins after the violation of a primary Entry/Exit zone. During this, it is permissible to violate follower zones without causing an alarm condition if an Entry/Exit zone was violated first. If a follower zone is violated without a prior Entry/Exit zone violation, it will be treated as an instant zone. If an instant zone is violated during this period, an alarm condition will immediately be registered. Select the appropriate value for the primary entry delay from the same table for sub-location 6.
Page 45
IDS 816 700-283-02I Issued September 2009
45
Sub-location 8 Secondary Entry Delay
(Values identical to Sub-location 6) The secondary entry delay applies to secondary Entry/Exit zones. Once an entry has been initiated, subsequent violations of any entry zone will NOT reset the entry time. Use the same table from Sub-location 6 to look up the value for the time interval required.
Sub-location 9 Auto Arm Time (Default = disabled)
This sub-location stores the time at which a particular partition will auto arm. The data format entered into this location is “hhmm” based on a 24-hour clock. Example: To auto arm at 11:35pm, enter 2335. All four digits must be entered, include any leading zeros (0100 for 1 am).
To disable this feature, ensure that no day of the week is selected in sub-location 10.
Sub-location 10 Auto Arm Days (Default = all OFF)
This Bitmapped sub-location sets the days on which the partition will auto arm at the time programmed in sub-location 9.
LED’s
Days of the Week
LED 1
Monday
LED 2
Tuesday
LED 3
Wednesday
LED 4 Thursday LED 5 Friday LED 6 Saturday LED 7 Sunday All OFF (Auto arm disabled)
Sub-location 11 Auto Disarm Time
This sub-location will store the time that the partition will auto disarm. The format of data entered into this location is “hhmm” based on a 24-hour clock. For example: To auto disarm at 11:35 am, enter 1135.
Sub-location 12 Auto Disarm Days
This Bitmapped sub-location sets the days on which the partition will auto disarm at the time programmed in sub-location 11.
LED’s
Days of the Week
LED 1 Monday LED 2 Tuesday
LED 3
Wednesday
LED 4
Thursday
LED 5 Friday LED 6 Saturday LED 7 Sunday
All OFF (Auto arm disabled) NOTE: Auto Disarm, if required, must be enabled per partition. (Sub-location 4).
Page 46
IDS 816 700-283-02I Issued September 2009
46
Sub-location 13 Auto Arm Delay
This location selects the delay period for the keypad buzzer warning, which is initiated before the panel auto arms. At the completion of the Auto Arm Delay, the panel will arm. A valid user code entered during the delay period will cancel the auto arming.
Value
Delay
Value
Delay
0 3 seconds 8 (Default) 2 minutes 1 10 seconds 9 3 minutes 2 15 seconds 10 4 minutes 3 20 seconds 11 5 minutes 4 25 seconds 12 10 minutes 5 30 seconds 13 15 minutes 6 45 seconds 14 18 minutes 7 1 minute 15 21 minutes
Sub-location 14 Reserved
Sub-location 15
Reserved
Partition Reporting Codes (for 4 x 2 & Domestic)
For all these locations, a two digit hexadecimal code must be programmed. To disable a reporting code, a double zero (00) must be entered into the corresponding location. Note that if one of the above­mentioned reporting digits is inadvertently omitted or programmed as a zero, the code will not be reported. The exception to this rule is when using domestic reporting where only the first digit is used.
Sub-location 16 Duress Reporting Code
This code is reported when a duress code is entered.
Sub-location 17 Keypad Panic Reporting Code
This code is reported when the [P] key on a keypad is held down for one second.
Sub-location 18
Keypad Fire Reporting Code
This code is reported when the [F] key on the keypad is held down for one second.
Sub-location 19 Keypad Medical Reporting Code
This code is reported when the [M] key on the keypad is held down for one second.
Sub-location 20 Keypad Lockout Reporting Code
This code is reported when a keypad lockout condition occurs.
Sub-locations 21 – 44 Partition Programmable Outputs
See “System Programmable Outputs” (Section 9, page 30) for details on programming the programmable outputs. The table below summarises the partition specific events that can be assigned to the outputs.
Page 47
IDS 816 700-283-02I Issued September 2009
47
Summary of Partition Event Driven Programmable Outputs
Sub-loc
Event
Output
Default Action
21 Close programmable output 3 Set high [0] 22 Stay close programmable output Disabled 23 Open programmable output 3 Set low [1] 24 Cancel programmable output Disabled 25 Alarm restoral programmable output Disabled 26 Bypass programmable output Disabled 27 Forced arm programmable output Disabled 28 Zone tamper programmable output Disabled
29
Zone tamper restoral programmable
output
Disabled
30 Zone shutdown programmable output Disabled
31
Zone shutdown restoral programmable output
Disabled
32 Keypad panic programmable output 1 Pulse high [2] 33 Keypad fire programmable output Disabled
34
Keypad medical programmable output
Disabled
35 Keypad lockout programmable output Disabled 36 Duress programmable output 1 Pulse high [2] 37 Verifies alarm programmable output Disabled 38 Burglary programmable output 2 Pulse high [2] 39 Panic programmable output 1 Pulse high [2] 40 Fire programmable output Disabled 41 Tamper zone programmable output Disabled 42 Siren programmable output Disabled
43
Strobe programmable output
Disabled
44
Chime programmable output
Disabled
Sub-location 45 Clear Programmable Outputs on Disarming
This bitmapped sub-location allows any programmable output to be cleared (set low) on disarming. The output(s) to be cleared will be displayed by zone LED’s that are on, representing the output i.e. zone 1 = output 1 etc. To toggle the status of the output, press the [NUMBER OF OUTPUT] [*] if the LED was off it will now come on and visa versa.
(To exit this mode press [#])
LED
Output
1 Panel - programmable output 1 2 Panel - programmable output 2 3 Panel - programmable output 3 4 Panel - programmable output 4
5
Panel - programmable output 5
6
Wired zone expander - programmable output 2
7 Wired zone expander - programmable output 1
Page 48
IDS 816 700-283-02I Issued September 2009
48
13. User Options
LOCATIONS 136 – 167 Individual User Code Setup
The IDS 816 provides for 32 user codes. These locations allow the installer to configure the user code properties.
Table 11 : User Code Locations
Loc Number
User Number
Loc Number
User Number
136
User 1
152
User 17
137 User 2 153 User 18 138 User 3 154 User 19 139 User 4 155 User 20 140 User 5 156 User 21 141 User 6 157 User 22 142 User 7 158 User 23 143 User 8 159 User 24 144 User 9 160 User 25 145 User 10 161 User 26 146 User 11 162 User 27
147
User 12
163
User 28
148
User 13
164
User 29
149 User 14 165 User 30 150 User 15 166 User 31 151 User 16 167 User 32
When the panel is defaulted, User Code 1 defaults to 1234 and is a Master User Code. All other User Codes are disabled.
Sub-location 1 Assigned to Partitions
This bitmapped sub-location determines which partition a user code is assigned to. By default, User Code 1 is assigned to Partitions 1 and 2. All other User Codes are assigned to Partition 1 only. (Depending on sub-location 2, bit 1). Change partitions by holding [MODE] for 1 second, [2] [*], in user mode – provided that the keypad is Global. (Sub-location 2, bit 4).
LED
Partition
LED 1 Partition one LED 2 Partition two
Sub-location 2 User Code Properties
This is a bitmapped sub-location.
LED
User Option
1 Master user 2 Duress code 3 Arm to disarm code (maid’s code) 4 Global Arm/Disarm
Page 49
IDS 816 700-283-02I Issued September 2009
49
NOTE:
A master user code allows for the programming of other user codes in User Programming Mode.
User Reporting Codes (for 4x 2 and Domestic Reporting)
For all these locations, a two digit hexadecimal code must be programmed. To disable a reporting code a double zero (00) must be entered into the corresponding location. Note that if one of the above­mentioned reporting digits is inadvertently omitted or programmed as a zero, the code will not be reported. The exception to this rule is when using domestic reporting where only the first digit is used.
Sub-location 3 Close Reporting Code
This code is reported when the panel is AWAY ARMED.
Sub-location 4 Stay Close Reporting Code
This code is reported when the panel is STAY ARMED.
Sub-location 5 Open Reporting Code
This code is reported when the panel is disarmed.
Sub-location 6 Siren Cancel Reporting Code
If the siren is sounding and the siren is cancelled using a valid user code, a cancel code will be reported. Cancelling a silent alarm or silent panic will not cause the cancel siren code to be reported.
14. Programmable Output Options
LOCATIONS 388 – 394 Programmable Output Timing Setup
Locations 388 to 394 allow the installer to setup the timing characteristics of each programmable output individually.
Location
Output No.
Output Type
388 1 Panel prog. output 1 389 2 Panel prog. output 2 390 3 Panel prog. output 3 391 4 Panel prog. output 4 392 5 Panel prog. output 5 393 6 Zone expander prog. output 2 394 7 Zone expander prog. output 1
Page 50
IDS 816 700-283-02I Issued September 2009
50
Sub-location 1 Output Pulse Time
This sub-location determines the length of time for which an output will pulse.
Value
Delay
Value
Delay
0 (Default)
3 seconds
8
2 minutes
1
10 seconds
9 3 minutes
2
15 seconds
10
4 minutes
3 20 seconds 11 5 minutes 4 25 seconds 12 10 minutes 5 30 seconds 13 15 minutes 6 45 seconds 14 18 minutes 7 1 minute 15 21 minutes
Output Scheduling
Outputs can be scheduled to set and reset at specified times on specific days of the week. To disable scheduling of an output ensure that all “days” are deselected.
Sub-location 2
Schedule ON Time
Enter the time using “hhmm” format at which the output is to be SET. (MUST be four digits)
Sub-location 3 Schedule ON Days
This bitmapped sub-location determines on which day(s) an output will be set.
LED
Days of the Week
1
Monday
2
Tuesday
3
Wednesday
4 Thursday 5 Friday 6 Saturday 7 Sunday
Sub-location 4 Schedule OFF Time
Enter the time using “hhmm” format at which the output is to be RESET. All four digits must be entered, include any leading zeros (0100 for 1 am, for example).
Sub-location 5 Schedule OFF Days
This bitmapped sub-location determines on which day(s) an output will be scheduled to RESET.
LED
Days of the Week
1
Monday
2
Tuesday
3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday
Page 51
IDS 816 700-283-02I Issued September 2009
51
15. Keypad Options
LOCATIONS 400 – 407 Individual Keypad Setup
These locations allow the installer to setup the individual keypad properties.
Location Keypad ID
400 Keypad 1
401
Keypad 2
402
Keypad 3
403
Keypad 4
404 Keypad 5 405 Keypad 6 406 Keypad 7 407 Keypad 8
Sub-location 1 Default Keypad Partition (Default = Partition 1)
This defines the partition to which a keypad will automatically return after viewing another partition.
Sub-location 2 Keypad Options
(Change partitions by entering [MODE] [*] [Partition Number] [*], in USER MODE)
LED
ON / OFF
Action
1*
ON
The keypad will timeout back to its default partition
after it has been used to view another partition
OFF
The keypad will not timeout and will continue to show current partition information
2
ON Keypad sleep mode enabled
OFF Keypad sleep mode disabled
3
ON Enable keypad zone
OFF Disable keypad zone
4
ON Enable global keypad status
OFF Disable global keypad status
Default values are shaded
* LED 4 must be ON in order for LED 1 to have any effect.
The Global Keypad Options will allow all sixteen zones to be displayed regardless of the partition
to which either the keypad or zones are assigned.
Keypad zones are mapped according to Keypad ID as shown in the table.
Page 52
IDS 816 700-283-02I Issued September 2009
52
Keypad Zone
Zone Number
Keypad ID 1 Zone 16 Keypad ID 2 Zone 15 Keypad ID 3 Zone 14 Keypad ID 4 Zone 13 Keypad ID 5 Zone 12
Keypad ID 6
Zone 11
Keypad ID 7
Zone 10
Keypad ID 8 Zone 9
16. Installer Options
LOCATION 444 Reset Switch Disable (Default = 0)
Value
Action
10 Disable reset switch
Any other value
Enable reset switch
For the detailed operation of this switch, refer to Section 3: Hardware Reset Switch.
LOCATION 445 Installers Code (Default = 9999)
Enter the installer code into this location.
LOCATION 446 View Keypad ID
View the data in this location to ascertain the Keypad ID
Page 53
IDS 816 700-283-02I Issued September 2009
53
Index of Programming Locations
LOCATION 0 Defaulting of the Panel or Master User Code ------------------------ 19 LOCATIONS 1 – 16 Individual Zone Setup -------------------------------------------------------- 19
Sub-location 1 ZoneType -------------------------------------------------------------------------- 19 Sub-location 2 Zone Properties (Defaults shaded) ------------------------------------------ 21 Sub-location 3 Alarm Reporting Code ---------------------------------------------------------- 22 Sub-location 4 Alarm Restoral Reporting Code----------------------------------------------- 22 Sub-location 5 Bypass Reporting Code -------------------------------------------------------- 22 Sub-location 6 Force Arm Reporting Code ---------------------------------------------------- 22 Sub-location 7 Tamper Reporting Code -------------------------------------------------------- 22 Sub-location 8 Tamper Restore Reporting Code --------------------------------------------- 22 Sub-location 9 Swinger Shutdown Reporting Code ----------------------------------------- 22 Sub-location 10 Swinger Shutdown Restore Reporting Code ------------------------------ 22 Sub-location 11 Zone Programmable Output Location--------------------------------------- 22 Sub-location 12 Zone Name Editing (LCD Keypads only) ----------------------------------- 22
LOCATION 33 Zone Shutdown Count (Default = 5) ------------------------------------ 23 LOCATION 34 Programmable Zone Loop Response Time --------------------------- 23 LOCATION 35 Reserved -------------------------------------------------------------------------- 23 LOCATION 36 Cross-zone Delay Timer ----------------------------------------------------- 23 LOCATION 37 Cross-zone Count (Default = 2) ------------------------------------------ 23 LOCATION 38 Global Options ------------------------------------------------------------------ 24 LOCATION 39 AC Fail / Restore Time ------------------------------------------------------- 25 LOCATION 40 Trouble Display ----------------------------------------------------------------- 26 LOCATION 41 Siren Time Out Period ------------------------------------------------------- 27 LOCATION 42 Siren Delay ----------------------------------------------------------------------- 27 LOCATION 43 Keypad Lockout Count (Default = 4) ----------------------------------- 27 LOCATION 44 Keypad Lockout Time (Default = 30 seconds) ---------------------- 28 LOCATION 45 Keypad Sleep Delay ---------------------------------------------------------- 28 LOCATION 46 User and Installer Code - Number of Digits -------------------------- 28 LOCATION 47 AC Failure Reporting Code------------------------------------------------- 28 LOCATION 48 AC Restoral Code ------------------------------------------------------------- 28 LOCATION 49 Low Battery Reporting Code----------------------------------------------- 29 LOCATION 50 Battery Restore Reporting Code ----------------------------------------- 29 LOCATION 51 Auto Test Reporting Code -------------------------------------------------- 29 LOCATION 52 Download Access Reporting Code -------------------------------------- 29 LOCATION 53 Siren Trouble Reporting Code -------------------------------------------- 29 LOCATION 56 Device Tamper Reporting Code ------------------------------------------ 29 LOCATION 57 Keypad Bus Failure Reporting Code ----------------------------------- 29 LOCATION 58 Box Tamper Reporting Code ---------------------------------------------- 29 LOCATION 59 Dedicated Panic --------------------------------------------------------------- 29 LOCATION 60 Phone Line Restoral RC ----------------------------------------------------- 29 LOCATION 61 RF Jamming RC ---------------------------------------------------------------- 29 LOCATION 62 RF Jamming Restore RC ---------------------------------------------------- 29 LOCATIONS 70 – 87 Event Driven Programmable Outputs ----------------------------------- 31 LOCATIONS 95 – 96 Function Driven Programmable Outputs ------------------------------ 31 LOCATION 98 System Time --------------------------------------------------------------------- 32 LOCATION 99 System Day of Month--------------------------------------------------------- 32 LOCATION 100 System Month ------------------------------------------------------------------- 32 LOCATION 101 System Year --------------------------------------------------------------------- 32 LOCATION 102 System Day of Week ---------------------------------------------------------- 32 LOCATION 103 Month to Start Daylight Saving ------------------------------------------- 33 LOCATION 104 Day of Week to Start Daylight Saving ---------------------------------- 33
Page 54
IDS 816 700-283-02I Issued September 2009
54
LOCATION 105 Week of Month to Start Daylight Saving ------------------------------- 33 LOCATION 106 Month to Return to Standard Time -------------------------------------- 33 LOCATION 107 Day of Week to Return to Standard Time------------------------------ 33 LOCATION 108 Week of Month to Return to Standard Time -------------------------- 33 LOCATION 109 Daylight Saving Time Offset ----------------------------------------------- 33 LOCATION 110 Communication Delay -------------------------------------------------------- 34 LOCATION 111 Reporting Options ------------------------------------------------------------- 34 LOCATION 112 Auto Test Interval -------------------------------------------------------------- 35 LOCATION 113 Auto Test Time ------------------------------------------------------------------ 35 LOCATION 114 Number of Account Code Digits (Default = 4) ---------------------- 35 LOCATION 115 Number of Dial Attempts (Default = 6) --------------------------------- 35 LOCATION 116 Primary Communicator Format ------------------------------------------- 36 LOCATION 117 Secondary Communicator Format --------------------------------------- 36 LOCATION 118 Global Group Reporting Code Enable / Disable 1 ----------------- 38 LOCATION 119 Global Group Reporting Code Enable / Disable 2 ----------------- 39 LOCATION 120 Global Group Reporting Code / Disable 3 ---------------------------- 40 LOCATION 121 Phone Number 1 --------------------------------------------------------------- 41 LOCATION 122 Phone Number 2 --------------------------------------------------------------- 41 LOCATION 123 Download Options ------------------------------------------------------------- 41 LOCATION 124 Number of Rings to Answer (Default = 15) --------------------------- 42 LOCATION 125 Call-back Phone Number --------------------------------------------------- 42 LOCATIONS 128 – 129 Partition Setup ------------------------------------------------------------------ 42
Sub-location 1 Partition Zone Allocation -------------------------------------------------------- 42 Sub-location 2 Primary Account Code ---------------------------------------------------------- 42 Sub-location 3 Secondary Account Code ------------------------------------------------------ 42 Sub-location 4 Partition Arm Options------------------------------------------------------------ 43 Sub-location 5 Partition Options ------------------------------------------------------------------ 44 Sub-location 6 Exit Delay Period ----------------------------------------------------------------- 44 Sub-location 7 Primary Entry Delay Time ------------------------------------------------------- 44 Sub-location 8 Secondary Entry Delay ---------------------------------------------------------- 45 Sub-location 9 Auto Arm Time (Default = disabled) ----------------------------------------- 45 Sub-location 10 Auto Arm Days (Default = all OFF) ------------------------------------------- 45 Sub-location 11 Auto Disarm Time ----------------------------------------------------------------- 45 Sub-location 12 Auto Disarm Days ----------------------------------------------------------------- 45 Sub-location 13 Auto Arm Delay -------------------------------------------------------------------- 46 Sub-location 14 Reserved ---------------------------------------------------------------------------- 46 Sub-location 15 Reserved ---------------------------------------------------------------------------- 46 Sub-location 16 Duress Reporting Code --------------------------------------------------------- 46 Sub-location 17 Keypad Panic Reporting Code ------------------------------------------------ 46 Sub-location 18 Keypad Fire Reporting Code --------------------------------------------------- 46 Sub-location 19 Keypad Medical Reporting Code --------------------------------------------- 46 Sub-location 20 Keypad Lockout Reporting Code -------------------------------------------- 46 Sub-locations 21 – 44 Partition Programmable Outputs --------------------------------------------- 46 Sub-location 45 Clear Programmable Outputs On Disarming ------------------------------ 47
LOCATIONS 136 – 167 Individual User Code Setup ------------------------------------------------ 48
Sub-location 1 Assigned to Partitions ----------------------------------------------------------- 48 Sub-location 2 User Code Properties ------------------------------------------------------------ 48 Sub-location 3 Close Reporting Code ----------------------------------------------------------- 49 Sub-location 4 Stay Close Reporting Code----------------------------------------------------- 49 Sub-location 5 Open Reporting Code ----------------------------------------------------------- 49 Sub-location 6 Siren Cancel Reporting Code -------------------------------------------------- 49
LOCATIONS 388 – 394 Programmable Output Timing Setup------------------------------------- 49
Sub-location 1 Output Pulse Time ---------------------------------------------------------------- 50 Sub-location 2 Schedule ON Time --------------------------------------------------------------- 50
Page 55
IDS 816 700-283-02I Issued September 2009
55
Sub-location 3 Schedule ON Days --------------------------------------------------------------- 50 Sub-location 4 Schedule OFF Time -------------------------------------------------------------- 50 Sub-location 5 Schedule OFF Days -------------------------------------------------------------- 50
LOCATIONS 400 – 407 Individual Keypad Setup ----------------------------------------------------- 51
Sub-location 1 Default Keypad Partition (Default = Partition 1) --------------------------- 51 Sub-location 2 Keypad Options ------------------------------------------------------------------- 51
LOCATION 444 Reset Switch Disable (Default = 0) --------------------------------------- 52 LOCATION 445 Installers Code (Default = 9999) ------------------------------------------ 52 LOCATION 446 View Keypad ID ------------------------------------------------------------------ 52
Page 56
IDS 816 700-283-02I Issued September 2009
56
Index
2
24 Hour Alarm Zone ......................................................................................................................................... 20
A
AC Fail / Restore Time ..................................................................................................................................... 25
AC Failure Reporting Code .............................................................................................................................. 28
AC Restoral Code ............................................................................................................................................. 28
Alarm Reporting Code ..................................................................................................................................... 22
Alarm Restoral Reporting Code ....................................................................................................................... 22
Arm/Disarm Zone ............................................................................................................................................. 20
Auto Arm Days .................................................................................................................................................. 45
Auto Arm Delay ................................................................................................................................................. 46
Auto Arm Time .................................................................................................................................................. 45
Auto Disarm Days............................................................................................................................................. 45
Auto Disarm Time ............................................................................................................................................. 45
Auto Test Interval .............................................................................................................................................. 35
Auto Test Reporting Code ............................................................................................................................... 29
Auto Test Time .................................................................................................................................................. 35
B
Battery Restore Reporting Code ..................................................................................................................... 29
Bitmapped Location ................................................................................................................................... 18, 21
Box Tamper ...................................................................................................................................................... 12
Box Tamper Reporting Code ........................................................................................................................... 29
Bypass Reporting Code ................................................................................................................................... 22
C
Call-back Phone Number ................................................................................................................................ 42
Clear Programmable Outputs On Disarming ................................................................................................. 47
Close Reporting Code ..................................................................................................................................... 49
Communication Delay ...................................................................................................................................... 34
Communicator Format ..................................................................................................................................... 36
Communicator Options .................................................................................................................................... 34
Contact ID Reporting Codes ........................................................................................................................... 37
Contact ID ......................................................................................................................................................... 37
Cross-zone Count ............................................................................................................................................ 23
Cross-zone Delay Timer ................................................................................................................................... 23
Cross-zoning .................................................................................................................................................... 21
D
Daylight Saving ................................................................................................................................................. 33
Dedicated Panic Reporting Code ................................................................................................................... 39
Default Keypad Partition .................................................................................................................................. 51
Defaulting Keypads .......................................................................................................................................... 14
Defaulting of the Panel or Master User Code ................................................................................................. 19
Defaulting the Panel ......................................................................................................................................... 13
Device Tamper Reporting Code ...................................................................................................................... 29
Devices (Enrolling) ........................................................................................................................................... 13
Disabled Zone .................................................................................................................................................. 20
Domestic Reporting (Notes) ............................................................................................................................ 37
Doubling ................................................................................................................................ See Zone Doubling
Download Access Reporting Code ................................................................................................................. 29
Download Code ................................................................................................................................................ 15
Page 57
IDS 816 700-283-02I Issued September 2009
57
Download Options............................................................................................................................................ 41
Downloading Software ..................................................................................................................................... 15
Dual Reporting .................................................................................................................................................. 36
Duress Reporting Code (Explanation) ............................................................................................................ 46
E
Earth .................................................................................................................................................................. 12
Enabling / Disabling Reporting Groups .......................................................................................................... 37
End-of-Line Resistors ....................................................................................................................................... 10
Engineer Reset (Explanation) .......................................................................................................................... 44
Enrolling Keypads ............................................................................................................................................ 13
Entering Program Mode ................................................................................................................................... 17
Event Driven Programmable Outputs ............................................................................................................. 31
Event Log .......................................................................................................................................................... 13
Exit Delay Period .............................................................................................................................................. 44
Expander Module - Installation ........................................................................................................................ 12
F
Faulty Keypad ................................................................................................................................................... 14
Fire Detect Output Sequence .......................................................................................................................... 22
Fire Zone ........................................................................................................................................................... 20
Follower Zone ................................................................................................................................................... 20
Follower/Entry Zone ......................................................................................................................................... 20
Force Arm (Explanation) .................................................................................................................................. 43
Force Arm Reporting Code .............................................................................................................................. 22
Function Driven Programmable Outputs ........................................................................................................ 31
G
Global Options.................................................................................................................................................. 24
Group Reporting Code Enable / Disable ........................................................................................................ 38
H
Hardware Reset Switch .................................................................................................................................... 13
Hexadecimal Value ........................................................................................................................................... 17
I
Incorrect Data Entries ....................................................................................................................................... 18
Individual Keypad Setup .................................................................................................................................. 51
Individual User Code Setup ............................................................................................................................. 48
Individual Zone Setup ...................................................................................................................................... 19
Installation ........................................................................................................................................................... 9
Installer Code .................................................................................................................................................... 15
Installer Options ................................................................................................................................................ 52
Installers Code .................................................................................................................................................. 52
Instant Zone ...................................................................................................................................................... 20
K
Keypad Allocation Problem ............................................................................................................................. 14
Keypad Bus ................................................................................................................................................ 13, 29
Keypad Bus Failure Reporting Code .............................................................................................................. 29
Keypad Fire Reporting Code (Explanation) .................................................................................................... 46
Keypad Lockout Count .................................................................................................................................... 27
Keypad Lockout Reporting Code (Explanation) ............................................................................................. 46
Keypad Lockout Time ...................................................................................................................................... 28
Keypad Medical Reporting Code (Explanation) ............................................................................................. 46
Keypad Options ................................................................................................................................................ 51
Page 58
IDS 816 700-283-02I Issued September 2009
58
Keypad Panic Reporting Code (Explanation) ................................................................................................. 46
Keypad Setup (Individual)................................................................................................................................ 51
Keypad Sleep Delay ......................................................................................................................................... 28
Keypads (Enrolling) .......................................................................................................................................... 13
Key-switch ......................................................................................................................................................... 12
L
Lightning Protection ......................................................................................................................................... 12
Location / Zone Defaults .................................................................................................................................. 19
Location Number .............................................................................................................................................. 17
Location Values ................................................................................................................................................ 15
Log ................................................................................................................................................ See Event Log
Low Battery Reporting Code ........................................................................................................................... 29
M
Mains Failure .................................................................................................................................................... 10
N
Number of Account Code Digits ..................................................................................................................... 35
Number of Dial Attempts ................................................................................................................................. 35
Number of Rings to Answer ............................................................................................................................. 42
O
Open Reporting Code ...................................................................................................................................... 49
Outdoor Instant Zone ....................................................................................................................................... 20
Output Pulse Time (Programme Location) ..................................................................................................... 50
Outputs .................................................................................................................. See Programmable Outputs
P
Panic/Priority Zone ........................................................................................................................................... 20
Partition Arm Options ....................................................................................................................................... 43
Partition Options ............................................................................................................................................... 44
Partition Programmable Outputs ..................................................................................................................... 46
Partition Reporting Codes (Explanation) ......................................................................................................... 46
Partition Setup .................................................................................................................................................. 42
Partition Zone Allocation .................................................................................................................................. 42
Peripheral Devices............................................................................................................................................ 10
Phone Line Restoral Reporting Code.............................................................................................................. 29
Primary Account Code (Partition Setup) ......................................................................................................... 42
Primary Communicator Format ....................................................................................................................... 36
Primary Entry Delay Time ................................................................................................................................. 44
Primary Entry/Exit Zone .................................................................................................................................... 20
Programmable Output Location ...................................................................................................................... 22
Programmable Output Actions ........................................................................................................................ 30
Programmable Output Numbering.................................................................................................................. 30
Programmable Output Options (Programming locations)............................................................................. 49
Programmable Output Timing Setup .............................................................................................................. 49
Programmable Outputs ................................................................................................................................... 12
Programmable Zone Loop Response Time ................................................................................................... 23
Programmable Zone Types ............................................................................................................................. 20
Programming a Bitmapped Location .............................................................................................................. 18
Programming Extended Locations .................................................................................................................. 17
Programming Location Summary ................................................................................................................... 18
Programming Standard Locations .................................................................................................................. 17
Programming Telephone Numbers ................................................................................................................. 40
Programming the Panel ................................................................................................................................... 15
Push to Arm Zone ............................................................................................................................................. 20
Page 59
IDS 816 700-283-02I Issued September 2009
59
Q
Quick Arm (Explanation) .................................................................................................................................. 43
R
Radio Transmitter Connection ......................................................................................................................... 13
Remote Control Receiver ................................................................................................................................. 13
Remote Control Unit ......................................................................................................................................... 12
Remote Receiver (IDS) ..................................................................................................................................... 13
Replacement Keypad....................................................................................................................................... 14
Replacing a Faulty Keypad/Device ................................................................................................................. 14
Reporting Groups (Enabling/Disabling) .......................................................................................................... 37
Reporting Options ............................................................................................................................................ 34
Resistors ................................................................................................................................................. 7, 10, 11
Resistors - Colour Codes ................................................................................................................................. 11
RF Jamming Reporting Code .......................................................................................................................... 29
RF Jamming Restore Reporting Code ............................................................................................................ 29
S
Schedule OFF Days ......................................................................................................................................... 50
Schedule OFF Time ......................................................................................................................................... 50
Schedule ON Days ........................................................................................................................................... 50
Schedule ON Time ........................................................................................................................................... 50
Secondary Account Code (Partition Setup) .................................................................................................... 42
Secondary Communicator Format .................................................................................................................. 36
Secondary Entry Delay ..................................................................................................................................... 45
Secondary Entry/Exit Zone............................................................................................................................... 20
Silent Zone ........................................................................................................................................................ 21
Siren Cancel Reporting Code .......................................................................................................................... 49
Siren Delay ........................................................................................................................................................ 27
Siren Time Out Period ...................................................................................................................................... 27
Siren Toot on Away Arm / Disarm (Explanation) ............................................................................................ 43
Siren Trouble Reporting Code ......................................................................................................................... 29
Stay Close Reporting Code ............................................................................................................................. 49
Stop Report and Control the Alarm Panel....................................................................................................... 36
Sub-location Number ....................................................................................................................................... 17
Swinger Shutdown ........................................................................................................................................... 21
Swinger Shutdown Reporting Code ................................................................................................................ 22
Swinger Shutdown Restore Reporting Code .................................................................................................. 22
System Clock Options ..................................................................................................................................... 32
System Day of Month ....................................................................................................................................... 32
System Day of Week ........................................................................................................................................ 32
System Month ................................................................................................................................................... 32
System Options ................................................................................................................................................ 23
System Programmable Outputs ...................................................................................................................... 30
System Reporting Codes ................................................................................................................................. 28
System Time ..................................................................................................................................................... 32
System Year ...................................................................................................................................................... 32
T
Tamper by Zone ............................................................................................................................................... 21
Tamper Reporting Code .................................................................................................................................. 22
Tamper Restore Reporting Code .................................................................................................................... 22
Tamper Zone .................................................................................................................................................... 20
Telephone Communicator - Connecting......................................................................................................... 12
Telephone Number Storage Locations ........................................................................................................... 41
Telephone Numbers (Programming) .............................................................................................................. 40
Transformer....................................................................................................................................................... 10
Trouble Display ................................................................................................................................................. 26
Page 60
IDS 816 700-283-02I Issued September 2009
60
U
User Code Properties ....................................................................................................................................... 48
User Reporting Codes ..................................................................................................................................... 49
V
View Keypad ..................................................................................................................................................... 52
W
Warning Zone ................................................................................................................................................... 20
Wiring .................................................................................................................................................................. 9
Z
Zone Doubling .................................................................................................................................................. 10
Zone Name Editing .......................................................................................................................................... 22
Zone Properties ................................................................................................................................................ 21
Zone Reporting Codes ..................................................................................................................................... 21
Zone Shutdown Count ..................................................................................................................................... 23
Zone Type ......................................................................................................................................................... 19
Page 61
IDS816 User Manual 700-283-01H Issued January 2009
Page 62
IDS816 User Manual 700-283-01H Issued January 2009
Page 63
IDS816 User Manual 700-283-01H Issued January 2009
Quick Reference User Guide
Description
Programming
Add a User Code [*] [Master Code] [*] [0] [*] [New Code] [*]
Change a User Code [*] [Master Code] [*] [2] [*] [Old Code] [*] [New Code] [*]
View a Slot Number
[*] [Master Code] [*] [3] [*] [User Code] [*]
View the Slot number via the zone LED’s
Edit User Code Properties
[*] [Master Code] [*] [4] [*] [User Code] [*] [2,3 or 4] [*]
2 = Duress 3 = Arm to Disarm Code 4 = Global Arm/Disarm Code
Allocate a User Code to a Partition
[*] [Master Code] [*] [5] [*] [User Code] [*] [Partition Number] [*] [#]
Teach a Remote to a User Code
[*] [Master Code] [*] [8] [*] [User Code] [*]
Press Tx Button
Delete a User Code by Code [*] [Master Code] [*] [9] [*] [User Code] [*]
Delete a User Code by Slot Number [*] [Master Code] [*] [10] [*] [Slot Number] [*]
Change Partitions [Mode] [1] [*] [Partition Number] [*]
Select a Stay Profile [Mode] [2] [*] [Profile Number] [*]
Program/Cancel Stay Zone [3] [Zone Number] [*] [#]
Program/Cancel Buzz Zone [4] [Zone Number [*] [#]
Program/Cancel Chime Zone [2] [Zone Number} [*] [#]
Quick Arm [1]
Quick Stay [5]
Stay Arm and Go [6]
Bypassing/Un-bypassing a Zone [9] [Zone Number] [*] [#]
Alarm Memory [0] Displays zones violated.
View Trouble Conditions
[7] 1 = AC Mains Fail 2 = No Communication 3 = Phone Line 4 = Siren Tamper 5 = Low Battery 6 = Loss of Clock Timer 7 = Engineer Reset 8 = Box Tamper 10 = Tamper on Peripheral 11 = Comms. Failure to Peripheral Device 12 = Loss of Power to Peripheral Device
Page 64
IDS816 User Manual 700-283-01H Issued January 2009