Identiv uTrust TouchSecure Wall Mount User Manual

TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 1 of 15
Internal Use Only
User Manual for
uTrust TS WALL MOUNT
Physical Access Control Readers
Version 1.4
Document number: 81x00 3
Confidential
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 2 of 15
Internal Use Only
Date
Version
Description of Changes
Author
10-July-15
1.0
Initial version
Suresh Kumar T
09-Oct-15
1.1
Wiegand length details modified
Suresh Kumar T
20-Nov-15
1.2
Updated input voltage range and added
document number
Sudhan
10-Dec-15
1.3
Current ratings updated as per comments from
UL
Sudhan
14-Dec-15
1.4
Document updated as per review comments from
UL
Sudhan
Version History
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 3 of 15
Internal Use Only
Contents
1.0 Introduction ................................................................................................................................ 4
2.0 Reader ......................................................................................................................................... 4
2.1 Functionality .............................................................................................................................. 4
2.2 Touch Secure® reader with Casing ......................................................................................... 4
2.3 Back Plate ................................................................................................................................. 5
2.4 Reader Variants ........................................................................................................................ 5
3.0 Product details ........................................................................................................................... 6
4.0 Specifications ............................................................................................................................. 6
4.1 Rated current at different operating voltages ........................................................................... 7
4.1.1 Rated current for Model 8100 ............................................................................................ 7
4.1.2 Rated current for Model 8110 ............................................................................................ 7
4.1.3 Rated current for Model 8130 ............................................................................................ 8
4.1.3.1 Rated current for 6-16V input ...................................................................................................... 8
4.1.3.2 Rated current for POE ................................................................................................................. 9
5.0 Installation details ...................................................................................................................... 9
5.1 Parts List ................................................................................................................................... 9
5.2 Recommended Infrastructure ................................................................................................... 9
5.3 Wiring Information ................................................................................................................... 10
5.3.1 Cable Color codes for Pig Tail Reader ............................................................................ 10
5.3.2 Pin out for Phoenix Connector Reader ........................................................................... 10
5.4 Mounting the Reader .............................................................................................................. 11
5.4.1 Location of mounting holes on wall ................................................................................. 11
5.4.2 Reader Installation Steps ................................................................................................ 12
5.5 Power up and Testing ............................................................................................................. 14
6.0 Certifications ............................................................................................................................ 14
6.1 FCC......................................................................................................................................... 14
6.2 IC ............................................................................................................................................ 14
6.3 CE ........................................................................................................................................... 14
6.4 UL 294 .................................................................................................................................... 15
6.4.1 UL 294 access control performance levels ..................................................................... 15
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 4 of 15
Internal Use Only

1.0 Introduction

This document details the Physical Access Control Reader TouchSecure® and its basic operational and installation procedures. It covers the details of the Wall mount form-factor reader.
Model: Connectivity/Standard WM
The reader comes in two variants for interfacing with the control panel
Pigtail – 8100ABP, 8110ABP
Phoenix connectors – 8100ABT, 8110ABT, 8130ABC
P-refers to Pigtail, T- refers to Terminal (Phoenix header)
The reader comes in three variants in functionality
Standard HF Only - 8100ABP, 8100ABT
Standard HF LF - 8110ABP, 8110ABT
Connectivity HF LF - 8130ABC
P-refers to Pigtail, T- refers to Terminal (Phoenix header), C- refers to connectivity
In connectivity, Only Terminal version is available.

2.0 Reader

2.1 Functionality

TouchSecure® is a physical access reader that can read HF and LF contactless credentials .The reader can interface with an access control system equipped with a Wiegand or RS485 serial interface Control Panel. It can also be interfaced with a Host Sever / Control Panel that supports Ethernet interface. User interfaces include RGB LED’s and Buzzer.
The reader consists of the following main parts.

2.2 Touch Secure® reader with Casing

TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 5 of 15
Internal Use Only

2.3 Back Plate

2.4 Reader Variants

TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 6 of 15
Internal Use Only
Model
Operating
Voltage
Current @ 12V
Operating temp
8100ABP
POE@ 48VDC

3.0 Product details

Model Name : Connectivity/Standard Wall Mount Device Type : RFID reader, 13.56MHz (HF) / 125 KHz (LF)
Physical Access control Reader (accessory equipment)
Type of equipment : Potted reader.
Suitable for Indoor Use – 8130ABC and
Outdoor use – 8100 ABP, 8100 A BT , 8110ABP, 811 0 ABT Interface Type : Pigtail Cable (11 Core + Drain) or Phoenix connectors and RJ45 Voltage Rating (8130ABC) : 6-16V DC or 48VDC on RJ45 Connector Voltage Rating (All other models): 5-16V DC Communication protocol : Wiegand, RS485 (2wire - Half Duplex), 10BaseT ETH
* Communication via Wiegand was evaluated by UL and serves as the interface between the reader and panel. Communication via RS485, OSDP or Ethernet was not evaluated by UL

4.0 Specifications

8100ABT
STANDARD HF
ONLY
8110ABP 8110ABT
HF LF
8130ABC
HF LF
CONNECTIVITY
* POE sourcing equipment shall be UL 294 or UL 294B Listed with Class 2 output
When the readers use POE as a power source, the power input wiring from the control unit (i.e. Red and Black for 8130) shall be disconnected
The maximum length of the Ethernet cable when using POE as the power source in UL installations is limited to 30 meters (98.5 feet)
There shall be no connections made to the RS-485 interface ( RS485+ and RS485-) for UL installations
Note: Standby Power is not provided by the Card Readers. The Standby Power Level is dependent on the external power source connected to the Card Reader.
All wiring or cables to the Card Readers shall be the shielded type
5-16 VDC
5-16 VDC
6-16 VDC
Refer graph in
section 4.1
Refer graph in
section 4.1
Refer graph in
section 4.1
-35 to +65 Deg C
0 to +49 Deg C
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 7 of 15
Internal Use Only
Voltage (V)
Average Current (mA)
Peak Current (mA)
5
147
166 8 150
178
10
116
138
12
97
114
14
83
100
16
73
86
Voltage (V)
Average Current (mA)
Peak Current (mA)
5
147
166 8 150
178
10
116
138
12
97
114
14
83
100
16
73
86
Only UL Listed POE sourcing equipment, or UL Listed power-limited power supply, or power- limited output from UL Listed control panel shall be used for the Power-Over- Ethernet feature. Cat 5e cabling is the minimum performance category recommended. These Card Readers when using POE feature are not intended for outside wiring as covered by Article 800 of the US National Electrical Code, NFPA 70.

4.1 Rated current at different operating voltages

4.1.1 Rated current for Model 8100

4.1.2 Rated current for Model 8110

TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 8 of 15
Internal Use Only
Voltage (V)
Average Current (mA)
Peak Current (mA)
6
280
308
8
261
292
10
217
257
12
172
202
14
148
173
16
131
156

4.1.3 Rated current for Model 8130

4.1.3.1 Rated current for 6-16V input
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 9 of 15
Internal Use Only
Voltage (V)
Average Current (mA)
Peak Current (mA)
37
65
70
48
50
55
57
45
50
4.1.3.2 Rated current for POE

5.0 Installation details

Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.

5.1 Parts List

TouchSecure® reader -1
Screws (A #6-18X1.5" SS ) - 4Nos – Back Plate mounting screws for Wall
Snake Eye Screw (SMF #6-32X5/16" SS) – 1 No- Top casing mounting security screw
Screws (SMF #6-32x3/8" SS) - 3 No’s - 1 casing to back plate mounting screw and 2 Junction
Box mounting screws
Nylon anchor plug -4 Nos
6 pin phoenix plug (Phoenix connector version only) – 2 Nos
Back Plate

5.2 Recommended Infrastructure

All cabling and wiring shall be UL Listed and/or UL Recognized
All readers shall be powered by UL listed POE sourcing equipment, UL listed power-limited
power supply, or power-limited output from UL listed control panel
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 10 of 15
Internal Use Only
Red
&
+ VDC 12V (nominal)
Black & White
Ground
Green
Wiegand Data 0
White
Wiegand Data 1
Orange
LED Green
Yellow
Buzzer
Blue
Hold
Brown
LED Red
Grey
RS485 -
Pink
RS 485 +
Violet
Tamper Output
Black / Drain
Shield Ground
There shall be no connections made to the RS-485 interface ( RS485+ and RS485-) for UL installations
Cable Wiegand - 22AWG Shielded cable. ( Cable P No : ALPHA WIRE, P/N 1299/10C)
Cable RS485 - RS485 for 1000m** (4000ft) 24AWG STP
Cable RJ45 - Cat5e / Cat6
Linear DC PS - 5-16 V, 1A min.
** Tested in lab conditions up to 115Kbaud

5.3 Wiring Information

5.3.1 Cable Color codes for Pig Tail Reader

Table 2
& -
Do not connect when reader is powered by Power over Ethernet

5.3.2 Pin out for Phoenix Connector Reader

TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 11 of 15
Internal Use Only
Pin
Cable color
Description
Comment
P1.1
Orange
LED Green
P1.2
White
Data 1
P1.3
Green
Data 0
P1.4
Black
Drain
Connect drain to Cable shield
P1.5
Black + White
Gnd
P1.6
Red
Power
Do not connect when reader is powered by PoE
P2.1
Blue
Hold
P2.2
Violet
Tamper
P2.3
Gray
RS485-
P2.4
Pink
RS485+
P2.5
Yellow
Buzzer
P2.6
Brown
LED Red
Table 3
Caution:
During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might affect reader functionality/ cause damage to the reader.

5.4 Mounting the Reader

5.4.1 Location of mounting holes on wall

TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 12 of 15
Internal Use Only
Phoenix connector Reader – 4 Holes and 1 Slot

5.4.2 Reader Installation Steps

a. Make holes on the wall as per the image above. b. Insert the nylon screw plugs into the wall. c. Connect the wires as per the Table 2 or Table 3. d. TouchSecure® reader with Bottom Casing is to be now secured onto the wall using the
Screws (A #6-18X1.5" SS )
e. The top casing can be inserted onto the bottom casing f. Secure the Top and bottom casing by the Snake Eye Screw (SMF #6-32X5/16" SS)
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 13 of 15
Internal Use Only
Reader Installation Steps - Phoenix Connector Version
Reader Installation Steps - Pig Tail Version
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 14 of 15
Internal Use Only

5.5 Power up and Testing

1 Turn power on
The LED blinks 3 times green with a long beep, then turns red
2 Present a card
The LED blinks green, and a short Beep is emitted
This is the default reader behavior.

6.0 Certifications

6.1 FCC

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protectio n a gai ns t harmful interference i n a r esid ent ial i nstal lat io n. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the ins tructions, may cause harmful in terference to radio communications . However, there is no guar antee that interference will not occur in a particular installation. If this equipment does c ause harm ful interf erence to ra dio or t elevision r eceptio n, which can be determined by turn ing the equipment of f and on, the user is encouraged to tr y to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipm ent into an out let on a circ uit differ ent from that to which the rec eiver is connected. —Consult the dealer or an experienced radio/TV technician for help.
Information to user
Changes or modifications not expressly approved by Identive could void the user's authority to operate the equipment.

6.2 IC

This Class B digital apparatus complies with Canadian ICES-003. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference (2) This device must accept any interference, including interference that may cause
undesired operation of the device.

6.3 CE

Identive hereby declares that the TouchSecure® Model: Connectivity WM device mentioned herein is in compliance with the essential requirements and other relevant portions of the Directive R&TTE 1999/5/EC.
TouchSecure® WallMount User Manual
IDT.QM.P2.T1.DT
Ver1.0
Page 15 of 15
Internal Use Only

6.4 UL 294

Communication via W iegand was evalua ted b y UL and serves as the interface between the reader and panel
Communication via RS485 or OSDP is not permitted
Communication via Ethernet was not evaluated by UL
The maximum length of the Ethernet cable when using POE as the power source in UL
installations is limited to 30 meters (98.5 feet)

6.4.1 UL 294 access control performance levels

Destructive attack : Level IV Line Security : Level I Endurance : Level I Standby Power : Level I
Loading...