1.0 Introduction
This document details the Ph ysical Access Control Reader uTrust TS KEYPAD and its basic user
instruction and installation procedur es .
2.0 Reader
2.1 Functionality
TS KEYPAD reader is a physical access control smart card reader that can read HF and LF
contactless credentials, co nforming to the follo wing standards: ISO 14443 A & B, ISO15693 with a
keypad PIN entry for additional security. The reader can interface with an access control system
equipped with a Wiegand or RS485 serial interface. User interfaces include RGB LED’s and Buzzer.
2.2 Front/Top Casing
uTrust TS KEYPAD User Manual
Page 5 of 12
2.3 Back View/plate
Back plate
Standard version
uTrust TS KEYPAD User Manual
Page 6 of 12
Model
Operating
Voltage
Current @ 12V
Operating
temperature
Operating
humidity
3.0 Product details
Model Name : uTrust TS keypad
Device Type : RFID reader, 13.56MHz (HF) / 125 KHz (LF), keypad
Physical Access control Reader (accessory equipment)
Type of equipment : Potted Reader, Suitable for Indoor use
Interface Type : Phoenix connectors
Voltage Rating : 6-16V DC
Current Rating @12V : Peak Current – 157 mA, Average Current 110 mA
Communication protocol : Wiegand, RS485 (2wire - Half Duplex)
4.0 Specifications
8210
uTrust TS
KEYPAD
6-16 VDC
Av -110 mA
Pk -157 mA
5.0 Label
0 to +49C
85 +/-5 % RH
Caution:
uTrust TS KEYPAD User Manual
Page 7 of 12
During wiring, make sure that the +VDC lines does not make contact with any other cables, as it might
affect reader functionality/ cause damage to the reader.
6.0 Installation details
Wiring methods shall be in accordance with the Nat ion al Electr ic al Code (AN SI/N FPA7 0) , local co des,
and the authorities having jurisdiction.
6.1 Parts List
• TS Keypad reader -1
• Screws (A #6-18X1.5" SS ) - 4Nos – Back Plate mounting screws for Wall
All cabling and wiring shall be UL Listed and/or UL Recognized.
•Cable Wiegand - 22AWG Shielded cable. ( Cable P No : ALPHA WIRE, P/N
1299/10C)
• Cable RS485 - RS485 for 1000m** (4000ft) 24AWG STP
• Class 2 Linear DC PS - 6-16 V, 1A min
** Tested in lab conditions up to 115Kbaud
6.3 Connector Information
6.3.1 Pinout diagram
uTrust TS KEYPAD User Manual
Page 8 of 12
- Shield G r ound/ Drai n – Black color should be connected to the cable
shield.
Caution:
During wiring, make sure that the +VDC lines does not make contact with any other cables, as it might
affect reader functionality/ cause damage to the reader.
6.4 Mounting the Reader
6.4.1 Location of mounting holes on wall
uTrust TS KEYPAD User Manual
Page 9 of 12
Phoenix connector Reader – 4 Holes and 1 Slot
6.4.2 Reader Installation Steps
a. Make holes on the wall as per the image above.
b. Insert the nylon screw plugs into the wall.
c. Connect the wires as per the Table 2 or Table 3.
d. TouchSecure® reader with Bottom Casing is to be now secured onto the wall using the
Screws (A #6-18X1.5" SS )
e. The top casing can be inserted onto the bottom casing
f. Secure the Top and bottom casing by the Snake Eye Screw (SMF #6-32X5/16" SS)
uTrust TS KEYPAD User Manual
Page 10 of 12
uTrust TS KEYPAD User Manual
Page 11 of 12
7.0 Power up and Testing
1 Turn power on
The LED blinks 3 times green with a long beep, then turns red
2 Present a card
The LED blinks green, and a short Beep is emitted
3 Press Key
Buzzer tone & backlight LED blinks
4 Wiegand / RS485
Communication to the Panel is done through Wiegand / RS485 / OSDP.
This is the default reader behavior.
uTrust TS KEYPAD User Manual
Page 12 of 12
8.0 Certifications
8.1 FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protectio n a gai ns t harmful interference i n a r esid ent ial i nstal lat io n. This equipment
generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with t he instructions, may cause harm ful interference to radio communications.
However, there is no guar antee that interference will not occur in a particular installation. If
this equipment does c ause harm ful interf erence to ra dio or t elevision r eceptio n, which can be
determined by turn ing the equipment of f and on, the us er is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipm ent into an out let on a circ uit differ ent from that to which the rec eiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate
the equipment.
8.2 IC
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
8.3 UL 294 and UL 1076
•Communication via Wiegand was evaluated b y UL and serves as the interface between the
reader and panel
•When the reader is powered by a supply other than Identiv Mx series controller, the power
supply should be a UL 294 and 1076 listed , class 2 supply.
•For UL 1076, the reader was assessed for the acknowledgment signal annunciation while
interfacing to the Listed Identiv Mx series control unit via Wiegand only.
8.3.1 UL 294 access control performance levels
Destructive attack : Level IV
Line Security : Level I
Endurance : Level I
Standby Power : Level I