ø30 XN Series Emergency Stop Switches
ø30 mm, 4-contact Emergency Stop Switch. Padlockable and flush bezel are available.
•Padlockable, ush bezel, ø60mm jumbo mushroom, illuminated, LED push-on are available.
•IDEC’s original “Safe break action” and reverse energy structure ensure the highest level of safety.
•Safety lock mechanism (IEC 60947-5-5, 6.2)
•Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-
1, Annex K)
•Short depth behind the panel – only 47.7 mm for 4-contact, illumi­nated (ush bezel: 60.4 mm, padlockable: 61.4 mm)
•Padlockable can be locked using padlocks when latched (main contact: OFF). The rugged aluminum diecast shroud allows for installing a maxi mum of 20 padlocks using a hasp (total weight: 1500g maximum).
•Silver with gold contacts.
•Red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/14) colors are
available.
Standards and Specications
Contact Ratings
NC main contacts/NO monitor contacts
Rated Insulation Voltage (Ui) 250V Rated Thermal Current (Ith) 5A Rated Operating Voltage (Ue) 30V 125V 250V
Resistive Load
AC 50/60 Hz
Main Contacts
DC
AC
Rated Operating Current
Monitor Contacts
Contact Material Gold-plated Silver
50/60 Hz
DC
(AC-12) Inductive Load
(AC-15) Resistive Load
(DC-12) Inductive Load
(DC-13) Resistive Load
(AC-12) Inductive Load
(AC-14) Resistive Load
(DC-12) Inductive Load
(DC-13)
•Minimum applicable load: 5V AC/DC, 1 mA (reference value) (May vary depending on the operating conditions and load types.)
•The rated operating currents are measured at resistive/inductive load types specied in IEC 60947-5-1.
5A 3A
3A 1.5A
2A 0.4A 0.2A
1A 0.22A 0.1A
1.2A 0.6A
0.6A 0.3A
2A 0.4A 0.2A
1A 0.22A 0.1A
Illumination Ratings (LED)
Rated Voltage Operating Voltage Rated Current
24V AC/DC 24V AC/DC ±10% 15 mA
Note: An LED lamp is built into the contact block and cannot be replaced.
-
Direct Opening Action
Specifications
Applicable Standards
Operating Temperature
Storage Temperature –45 to +80°C Operating Humidity 45 to 85% RH (no condensation) Minimum Force Required for
Direct Opening Action Minimum Operator Stroke
Required for Direct Opening Action
Maximum Operator Stroke Contact Resistance Insulation Resistance Overvoltage Category II Impulse Withstand Voltage Pollution Degree 3 Operating Frequency 900 operations/hour
Shock Resistance
Vibration Resistance
Durability (at 900 operations/h, on-duration 40%)
Degree of Protection
Short-circuit Protection 250V/10A fuse (Type aM, IEC60269-1/IEC60269-2) Conditional Short-circuit
Current Terminal Style M3 screw terminal Recommended Tighten ing
Torque for Terminal Screw Recommended Tighten ing
Torque for Locking Ring Applicable Wire Size 0.75 to 1.25 mm Total Weight of a Hasp and
Padlocks Reinforced Insulation
(IEC 60664-1)
Weight
IEC60947-5-1, EN60947-5-1 IEC60947-5-5, EN60947-5-5 JIS C8201-5-1, UL508, UL991, NFPA79 CSA C22.2 No. 14, GB14048.5
Non-illuminated: –25 to +60°C (no freezing) Illuminated: –25 to +55°C (no freezing)
80N
4.0 mm
4.5 mm
50 mΩ maximum (initial value) 100 MΩ minimum (500V DC megger)
2.5 kV
Operating extremes: 150 m/s Damage limits: 1000 m/s
Operating extremes: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s Damage limits: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s
Mechanical: 250,000 operations minimum Electrical: 100,000 operations minimum 250,000 operations minimum (24V AC/DC, 100 mA)
Operator: IP65 (IEC60529) Terminal: IP20 (when XW9Z-VL2MF is installed)
1000A
0.6 to 1.0 N·m
2.5 N·m
2
(AWG18 to 16)
1500g maximum (padlockable)
Between live part and metal bezel (ush bezel, padlockable)
83g (XN1E-LV404Q4MR) 93g (XN1E-BV504MR) 89g (XN5E-LV404Q4MR) 120g (XN4E-LL404Q4MR)
2
2
2
2
Emergency Stop Switches
APEM
Switches & Pilot Lights
Control Boxes
Emergency Stop Switches
Enabling Switches
Safety Products
Explosion Proof
Terminal Blocks
Relays & Sockets
Circuit Protectors
Power Supplies
LED Illumination
Controllers
Operator Interfaces
Sensors
AUTO-ID
X6
XA
XW
XN
SEMI
D-038
Loading...