IDEC TWTD Series Instruction Sheet

Oiltight Switches & Pilot Devices
ø30mm - TWTD Series
Operating Instructions
Adjustment for Panel Thickness
A trim washer must be used with a thrust washer or a nameplate to prevent the control unit from rotating in the mounting hole. When using anti-rotation rings (trim washer with thrust washer or nameplate), install as shown below.
Installation of LED Illuminated Units
Transformer units are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. Use diode with AC power supply to protect against reverse polarity. Use with DC power supply to protect against surges and noise.
Make sure that LED illuminated units are installed with correct polarity, as indicated at
the terminals.
Application Example For Push-To-Test Pilot Light
A typical application of illuminated pushbuttons is a push-to-test pilot light which can be used to check the lamp/LED circuit.
Transformer/AC-Adapter Circuit
Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks
Selector Switches
The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the Standard Operating Positions.
Standard Operation Positions
2-Position, 90° 3-Position, 45°
0
1 2 1 2
Non-Illuminated 3-Position Operators
0
12
1
0
2
1
0
2
Installation of TWTD Series Units
TWTD Pilot Lights
TWTD Illuminated Pushbuttons TWTD Selector Switches (Transformer or Full Voltage)
Full Voltage Circuit
Circuit Breakers
Terminal X1 = Positive Terminal X2 = Negative
USA: 800-262-IDEC Canada: 888-317-IDEC
639
Loading...