ø30mm - TWND Series
Switches & Pilot Devices
Specifications
Conforming to Standards EN60947-5-1, UL508, CSA C22-2 No.14
CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Approvals
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
Operating Temperature
UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons
with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
TÜV: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Operation: –25 to +50°C (illuminated versions) -25 ~ +70C non-illuminated
Storage: –40 to +80°C (without freezing) C-> °C
Vibration Resistance 5 to 55Hz, 98m/sec2 (10g) conforming to IEC60068-2-6
Shock Resistance 980m/sec2 (100g) conforming to IEC60068-2-27
Electric Shock Protection Class 2 conforming to IEC60664-1
Degree of Protection
Mechanical Life
Pollution Degree
(conforming to IEC60947-1)
IP65 (from front of the panel) (conforming to IEC60529)
UL Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS6-110)
Momentary pushbuttons: 5,000,000 (1800 operations per hour)
All other switches: 500,000
3
Mechanical-Electrical Specifications
Rated Operational Characteristics AC-15: A600
Rated Insulation Voltage 600V
Rated Impulse Withstanding Voltage
øDielectric Strength
Rated Thermal Current 10 Amp
Minimum Switching Capacity 5 mA at 3V AC/DC (applicable range may vary with operating conditions and load types)
Contact Operation Slow break NC or NO
Operating Force
Recommended Terminal Torque
Applicable Wire Size Pilot Light
Between live and dead metal parts
2.5kV AC, 1 minute
Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary), 9.0±1.5N
Additional contacts—1NO or 1NC: +3.0N
Unit Wire Number of Wires
Crimping Terminal 2 1.0 to 1.3
HW-U Contact Block
Illuminated Unit (*1)
1. * refers to the lamp terminals of the illuminated push buttons and selector switches.
Solid Wire
Stranded Wire
Stranded Wire 0.3 to 2.0 mm (AWG14 to 22)
Solid Wire ø0.5 to 1.6 mm (AWG14 to 22)
Stranded Wire ø0.3 to 2.0 mm (AWG14 to 22)
ø0.5 to 1.6 mm (AWG14 to 22) 2 1.0 to 1.3
ø1.7 to 2.0 mm (AWG12) 1 1.2 to 1.3
2
0.3 to 2.0 mm
Crimping Terminal
Crimping Terminal
(AWG14 to 22) 2 1.0 to 1.3
2.1 to 3.5 mm2 (AWG12) 1 1.2 to 1.3
Recommended Tightening
Torque (Nm)
2 1.0 to 1.3 M3.5Solid Wire ø0.5 to 1.6 mm (AWG14 to 22)
2
0.6 to 1.0 (M3.0)
1.0 to 1.3 (M3.5)
Terminal Screw
M3.5
Contact Resistance Initial contact resistance of 50mΩ or less
Contact Gap
LED Ratings LEDs: 6V: 8mA, 12V: 11mA, 24V: 11mA, 120V: 8.8mA, 240V: 8.6mA
Contact Material Silver
4mm (NO and NC)
2mm (NO-EM and NC-LB)
Contact Ratings
Contact Ratings by Utilization Category IEC 60947-5-1
Contact Ratings by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
AC 50/60 Hz
Operation Current
DC
AC-12 Control of resistive loads & solid state loads 10A — 10A 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A
DC-12 Control of resistive loads & solid state loads 10A 5A — 2.2A 1.1A —
DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A —
AC-15 (A600)
DC-13 (P600)
746
1904041136