IDEC SmartRelay Data Sheet

1
PRODUCT DESCRIPTION
With an ever-changing market and
tough competition, you need an edge to
stay on top. This sixth-generation IDEC
SmartRelay meets your demands from all
small-scale applications by offering more
powerful hardware, a new display and full
BASE MODULE HIGHLIGHTS
Embedded RJ45 Ethernet Port
Remote program download, upload and
monitor
Integrated web server for remote
monitoring and control
Micro SD Card
Equipped with micro SD slot for program
storage, transfer and data logging
No need for a special memory cartridge
Data Logging
Up to 20,000 lines in a file with a maximum
of 50 files can be stored in the Micro SD
Memory card
Integrated Web Server
Easily monitor and control web pages with
no HTML knowledge
Instant monitoring and control using
standard web browser like Chrome, IE and
Firefox
View and control I/O status, timer,
counters, analog set point and more
There's an App for that!
Download iOS and Android App for free
Using the SmartRelay App, users can view
and control any I/O status, timer, counters,
and analog set point anywhere and at any
time
1:N Communication
FL1F SmartRelays now have the capability
to communicate with each other over an
Ethernet network
Up to 16 FL1F SmartRelays can be
configured on the network
6th-Generation IDEC SmartRelay
BASE MODULE GENERAL SPECIFICATIONS
Item Specications Standard
Operating
Temperature
Horizontal Mounting
0 to 55°C (no freezing)
Cold: IEC60068-2-1
Hot: IEC60068-2-2
Vertical Mounting
0 to 55°C (no freezing)
Storage/Transportation Temp.
–40 to +70°C (no freezing)
Relative Humidity
10 to 95% (no condensation) IEC60068-2-30
Atmospheric Pressure
795 to 1080hPa
Operating Condition
No corrosive gas
Degree of Protection
IP20
Vibration Resistance
5 to 8.4Hz, amplitude 3.5mm
8.4 to 150Hz, acceleration 9.8m/s²
IEC60068-2-6
Shock Resistance
147m/ IEC60068-2-27
Drop Test (packaged)
0.3m IEC60068-2-32
Emissions
Limit class B Group 1
EN 550 11/A
EN55022/B
EN50081-1
Electrostatic Discharge Immunity
8kV air discharge
6kV contact discharge
IEC61000-4-2
Radiation Field Immunity
Field Strength:
1V/m a nd 10V/m
IEC61000-4-3
Fast Transient Burst
2kV (power line)
2kV (I/O signal line)
IEC61000-4-4
Surge Immunity
1
(FL1F-H12RCC, FL1F-B12RCC only)
1kV (power line) normal
2kV (power line) common
IEC61000-4-5
Communication Cable
2.5mm ² (one wire)
1.5mm² (two wires)
Terminal Style
Finger-safe type
2
1: For protection against surge noise on DC power supply types (FL1F-H12RCE/B12RCE, FL1F-H12SCD, FL1F-H12RCA/B12RCA), use surge absorbers,
noise cut transformers or noise filters. Use of a surge protection device (DEHN + SÖHNE GmbH + Co, BVT AD 24 Part No. 918 402) is recommended.
2: Tightening torque 0.5 to 0.6N·m
R
USC
2
TEXT DISPLAY PANEL HIGHLIGHTS:
New and improved LCD display
Improved display with 6 lines and 20 characters per line, more than twice as many characters as before
Selectable white, amber or red backlighting for optical emphasis on alarms and events
Two RJ45 Ethernet ports
Use a standard Ethernet cable to the connect FL1F base module to the Text Display Panel. A special cable is not required.
Provide different ways to connect
Text Display General Specications
Item Specications Standard
Operating
Temperature
Horizontal
Mounting
0 to 55°C (no freezing)
Cold: IEC60068-2-1
Hot: IEC60068-2-2
Vertical
Mounting
0 to 55°C (no freezing)
Storage/Transportation Temp.
–40 to +70°C (no freezing)
Relative Humidity
10 to 95% (no condensation) IEC60068-2-30
Atmospheric Pressure
795 to 1080hPa
Operating Condition
No corrosive gas
Degree of Protection
IP20
Vibration Resistance
5 to 8.4Hz, amplitude
3.5mm
8.4 to 150Hz, acceleration
9.8m/s
2
IEC60068-2-6
Shock Resistance
147m/s
2
IEC60068-2-27
Drop Test (packaged)
0.3m IEC60068-2-32
Emissions
Limit class B Group 1
EN 55011/A
EN55022/B
EN50081-1
Electrostatic Discharge
Immunity
8kV air discharge
6kV contact discharge
IEC61000-4-2
Radiation Field Immunity
Field Strength:
1V/m and 10 V/m
IEC61000-4-3
Fast Transient Burst
2kV (power line)
2kV (I/O signal line)
IEC61000-4-4
Surge Immunity
1
(FL1F-H12RCC, FL1F-B12RCC only)
1kV (power line) normal
2kV (power line) common
IEC61000-4-5
Communication Cable
2.5mm
2
(one wire)
1.5mm
2
(two wires)
Terminal Style
Finger-safe type
2
1 For protection against surge noise on DC power supply types (FL1F-H12RCE/B12RCE, FL1F-H12SCD, FL1F-
H12RCA/B12RCA), use surge absorbers, noise cut transformers, or noise filters. Use of a surge protection device
(DEHN + SÖHNE GmbH + Co, BVT AD 24 Part No. 918 402) is recommended.
2 Tightening torque 0.5 to 0.6N·m
Text Display General Specications Cont.
Dimensions (W × H × D)
128.2 × 86 × 38.7 mm
Weight (approx.)
220g
Installation
Panel cut-out using mounting clips
Keyboard
Membrane keypad
Display
FSTN graphic display
(W × H: 160 × 96 dots)
LED backlight (White, Amber, Red)
Font type
English, Spanish, Russian, Chinese, Italian, Turkish,
German, Dutch, French, Japanese
Displayable string
1 screen 6 lines × 20 columns
Power Supply Specications
Power Voltage
24V AC/DC
12V DC
Allowable Voltage Range
20.4 to 26.4V AC
10.2 to 28.8V DC
Allowable Voltage Frequency
47 to 63Hz
Power Consumption
12V DC: 145mA (Typ.)
24V DC: 70mA (Typ.)
24V AC: 75mA (Typ.)
Data Transmission Rate
10/100M full/half duplex data transmission rate
LCD Display / Backlight Specications
LCD Display Durability
3
50,000 hours
Backlight Durability
4
20,000 hours
3 Display durability is calculated under ordinary operating and storage conditions: room temperature,
normal humidity below 65% RH, and not subjected to direct sunlight.
4 Backlight durability is the number of hours taken for the light to become 50% of the original brightness.
TEXT DISPLAY SPECIFICATIONS
Loading...
+ 4 hidden pages