IDEC RY2KS Series Catalog Page

Relays RY2KS Series
RY2KS-U AC120V
Basic Part No. Coil Voltage:
RY2KS Series — Miniature Magnetic Latching Relays
Key features of the RY2KS series include:
• Standard “ice cube” base, solder lug (14-pin) termination
• Operates by pulse input and maintains condition even during power failure
• Excellent self-holding performance
• Optional manual check button for circuit testing
• DIN rail, surface, and panel mount sockets available for a wide range of mounting applications
Contact Material
Contact Resistance
Minimum Applicable Load
Operating Time
Release Time
Maximum Continuous Applied Voltage (AC/DC) at 20°C
Set and Reset Voltages (AC/DC) at 20°C
Power Consumption
Insulation Resistance
Dielectric Strength
Specifications
Frequency Response
Temperature Rise
Vibration Resistance
Shock Resistance
Life Expectancy
Operating Temperature
Weight
Silver, gold-plated 50m maximum (initial value)
5V DC, 100mA
25ms maximum
25ms maximum
110% of the rated voltage
80% of the rated voltage
AC: approximately 1.6V (50Hz), 1.5VA (60Hz) DC: approximately 1.2W
100M minimum (with 500V DC megger)
Between live and dead parts: 1,500V AC, 1 minute Between contact circuit and opposite coil: 1,000V AC, 1 minute Between contact circuits: 1,000V AC, 1 minute (700V between NO-NC contacts)
1,800 operations/hour
Coil: 85°C maximum Contact: 65°C maximum
0 to 6G (55Hz maximum)
20G minimum
Electrical: over 200,000 operations (240V AC, 3A) Mechanical: over 5,000,000 operations
–30 to +70°C
67g (approximately)
UL Recognized File No. E55996
CSA Certified File No.LR35144
Ordering Information
Order standard voltages for fastest delivery. Allow extra delivery time for non-standard voltages.
E
Relays
www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC E-33
RY2KS Series Relays
Part Numbers
Part Numbers: RY2KS Series
Termination Contact Configuration Standard With Check Button
S: Solder/plug-in DPDT RY2KS-U RY2KS-UC
Ratings
Coil Ratings
Rated Current ±15% at 20°C
Rated Voltage 60Hz 50Hz Coil Resistance ±10% at 20°C
6V 250mA 260mA 6.3
AC
E
DC
Relays
12V 115mA 120mA 30.3 24V 56mA 58mA 132
120V 10.8mA 11.2mA 3,840
6V 200mA 30 12V 100mA 120 24V 50mA 480 48V 25mA 1,920
110V 11mA 10,000
Contact Ratings
Resistive Inductive
Voltage Nominal UL CSA Nominal UL CSA
30V DC 3A 3A 3A 1.5A 1.5A
100V DC 0.2A 0.12A 0.2A
120V AC 3A 3A 3A 1.5A 1.5A 1.5A
240V AC 3A 3A 3A 0.8A 0.8A 0.8A
2.Inductive load cos ø = 0.3, L/R = 7ms.
Applicable Sockets
Part Numbers: Sockets
Relay Standard DIN Rail Mount Finger-Safe DIN Rail Mount Panel Mount PC Mount Spring (optional)
RY2KS
SY4S-05 SY4S-05C SY4S-51
1.See Section F for details on sockets. All DIN rail mount sockets shown above can be mounted using DIN rail BNDN1000.
SY4S-61 SY4S-62
SFA-202 SY4S-51F3
E-34 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC