MODEL NO.
CO
CO
ON
)
CO
GE
)
)
ON
O
E
SOC
)
)
)
S
)
L
L
l
e
SHOC
U4
U2
6
62
4.2
26
30
3
M3
28.5
25
18.5
45
DIN Rail
NTACT
NFIGURATI
RATED LOAD (resistive
IL
VOLTA
POWER CONSUMPTION (approx. MAXIMUM VOLTAGE (of the rated voltage) PICKUP VOLTAGE (of the rated voltage DROPOUT VOLTAGE (of the rated voltage)
CONTACT RESISTANCE (initial value)
MINIMUM APPLICABLE LOAD
OPERATE TIME (at rated voltage)
RELEASE TIME (at rated voltage)
MECHANICA
ELECTRICA
DIELECTRIC STRENGTH
Between contact and coi Between poles
Between contacts of the same pol
K RESISTANCE
VIBRATION RESISTANCE
R
AgSnOIn (silver tin oxide indium 10A/250V AC, 10A/30V D
24, 110-120, 220-240V A 12, 24, 110V D
1.1-1.4VA (AC); 0.9-1.0W (DC AC: 110%; DC: 110 AC: 80% maximum; DC: 80% maximu AC: 30% minimum; DC: 10% minimu
xim
24VDC, 5mA (reference value)
msec maximu
2
20 msec maximu
AC: 20,000,000 operations minimu DC: 30,000,000 operations minimu
ee electrical life curv
2,500VAC, 1 minut 2,500VAC, 1 minut 1,000VAC, 1 minut
Operating extremes: 150 m/
amage limits: 1,000 m
Operatin
extremes: 10 to 55Hz, Amplitude 1.0 mm p-
2
2
(100G)
(15G)
Damage limits: 10 to 55Hz, Amplitude 1.0 mm p-
R
AuAg/Ag (gold-silver alloy on silver) 6A/250V AC, 6A/30V D
24, 110-120, 220-240V A 12, 24, 110V DC
1.1-1.4VA (AC); 0.9-1.0W (DC) AC: 110%; DC: 110% AC: 80% maximum; DC: 80% maximum AC: 30% minimum; DC: 10% minimum
50 mΩ maximum
5VDC, 5mA (reference value)
20 msec maximum
20 msec maximum
AC: 20,000,000 operations minimum DC: 30,000,000 operations minimum
See electrical life curve
2,500VAC, 1 minute 2,000VAC, 1 minute 1,000VAC, 1 minute
Operating extremes: 150 m/s
2
(15G)
Damage limits: 1,000 m/s2 (100G)
Operating extremes: 10 to 55Hz, Amplitude 1.0 mm p-p Damage limits: 10 to 55Hz, Amplitude 1.0 mm p-p
DEGREE OF PROTECTI
PERATING TEMPERATUR
APPLICABLE
KET(DIN RAIL MOUNT
DIMENSIONS (H x W x D mm
WEIGHT (approx.
APPROVAL
INTERNAL CONNECTION (bottom view
IP4
-55 to +70C (no freezin
-05
x 21.0 x 27.
35
UL, c-UL,
V, C
(4)42
(8)44
(12)41
(14)A2
RU2 Electrical Life Curve
AC250V
7
10
DC30V
(1)12
(5)14
(9)11
(13)A1
100V AC/DC or more24V AC/DC or les
Resistive Loads Resistive Loads
(4)42
(8)44
(12)41
(14)A2
IP40
-55 to +70°C (no freezing)
SY4S-05
35.0 x 21.0 x 27.5
35g
UL, c-UL, TÜV, CE
(1)12
(5)14
(9)11
(13)A1
(3)32
(2)22
(6)24
(7)34
(11)31
(10)21
24V AC/DC or less
(4)42
(8)44
(12)41
(14)A2
RU4 Electrical Life Curve
7
10
(1)12
(5)14
(9)11
(13)A1
100V AC/DC or more
AC250V DC30V
(2)22
(3)32
(6)24
(7)34
(10)21
(11)31
Resistive Loads Resistive Loads
(4)42
(8)44
(12)41
(14)A2
Before operating the manual latching lever, make sure to turn
6
10
6
10
off the power. Do not use the latching lever as a manual disconnect switch. Make sure that the manual
5
10
5
10
latching lever is never left at a pulled out position. Failure to observe this may affect the operation and contact life.
Life (number of operating cycles)
10
4
1
Switching current (A
Life (number of operating cycles)
10
4
0.1
0.5
6
31
Switching current (A)