Applicable Standards
Standards for Use
Interlocking device Type
/the level of coded
Applicable Directives
Operating Condition
Inpulse withstand voltage
<Uimp>
Raed Insulation voltage <Ui>
Thermal Current <Ith>
Contact Ratings
(Reference Values)
< Ue, Ie >
*2
Class of Protection
Operating Frequency
Operating Speed
10d
B
Mechanical durability
Electrical Durability
Actuator Tensile Strength
when Locked
Direct Opening Travel
Direct Opening Force
Contact Resistance
Degree of Protection
Conditional short circuit
current
Short-circuit Protective
Device
Rated Operating Voltage
Solenoid
Rated Current
Turn ON Voltage
Turn OFF Voltage
Rated Power Consumption
Rated Operating Voltage
Indicator
Rated Current
Light Source
Illumination Color
EN ISO14119, IEC60947-5-1, EN60947-5-1, GS-ET-19,
UL508, CSA C22.2 No.14, GB 14048. 5
IEC60204-1/EN60204-1
Type 2 Interlocking device
/ low level coded actuator (ISO14119)
Low Voltage Directive (2006/95/EC)
Machinery Directive (2006/42/EC)
Operating Temperature
Operating Humidity
Pollution Degree
Altitude
-25 to +55
℃ (no freezing)
20 to 95%RH (no condensation)
3 (Inside 2)
2000m maximum
2 5kV (Between ground and LED, solenoid circuit : 0.5kV)
250V (Between ground and LED, solenoid circuit : 30V)
2.5A
30V 125V 250V
AC Resistive load (AC12)
Inductive load (AC15)
DC Resistive load (DC12)
Inductive load (DC13)
- 2.5A 1.5A
- 1.5A 0.75A
2.5A 1.1A 0.55A
2.3A 0.55A 0.27A
Class Ⅱ (IEC61140) *3
900 operations/hour
0.05 to 1.0 m/s
2,000,000 (ISO 13849-1 Annex C Table C.1)
2,000,000 operations minimum (GS-ET-19)
the Rear Escape release Button: 3000 operations
minimum(Type HS5L-□L)
100,000 operations min. (AC-12 250V/1.5A)
2,000,000 operations min. (AC/DC 24V 100mA)
(900 operations / hour)
Fzh=1,400N minimum
F1max=1820N minimum (GS-ET-19) *4, *5
(Fzh=500N minimum : HS9Z-A55 actuator)
11 mm minimum (actuator: HS9Z-A51,A5P)
12 mm minimum (for other actuators)
120N minimum
50 mΩ maximum (initial value)
IP67 (IEC60529) ,Type 4X Indoor Use Only
50A(250V)
Use 250V / 10A fast acting type fuse *6
DC24V100%dutycycle
200 mA (initial value)
Rated voltage x 85% maximum (at 20℃)
Rated voltage x 10% minimum (at 20℃)
Approx. 5W
DC24V100%dutycycle
10 mA
LED
Green