IDEC HS5L Specification Sheet

HS5L Interlock Switch with Solenoid (4-Contact)
Four-contact solenoid interlock switches ideal for use on limited mounting spaces such as small doors.
• Compact body: 35 × 40 × 127mm
• The locking strength is 1400N.
• Spring clamp terminal block prevents loosening of wires due to vibration.
• A variety of circuits. Dual safety circuit and four-circuit independent outputs available.
2-Contact4-ContactActuatorDimensions / Instructions
• Gold-plated contacts suitable for small loads.
• Spring lock models (unlocks when the solenoid is energized) and solenoid lock models (locks when solenoid is energized) are available.
• The head orientation can be rotated, allowing 8 different actuator entries.
• Actuators can be used with other HS5 series interlock switches. Spring loaded actuator exclusive for HS5L available.
• LED indicator shows solenoid operation.
Spring Lock
• Automatically locks the actuator without power applied to the solenoid.
• After the machine stops, unlocking is completed by the solenoid, providing high safety features.
• Manual unlocking is possible in the event of power failure or maintenance using a manual unlocking key.
• Head removal detection circuitry (spring lock models only).
Solenoid Lock
• The actuator is locked when energized.
• The actuator is unlocked when de-energized.
• Flexible locking function can be achieved, for an application where locking is not required and sudden stopping of a machine must be prevented.
Specifications
EN ISO14119, GS-ET-19 (TÜV approval),
Applicable Standards
Type and Coded Level Type 2 low level coded interlocking device (ISO14119) Operating Temperature –25 to + 55°C (no freezing) Relative Humidity 20 to 95% (no condensation) Storage Temperature –40 to +80°C (no freezing) Pollution Degree 3 Impulse Withstand Insulation Resistance
(500V DC megger) Electric Shock Protection Class II (IEC61140) Degree of Protection IP67 (IEC60529) Type 4X Indoor Use Only
Shock Resistance
Vibration Resistance
Actuator Operating Speed 0.05
Direct Opening Travel
Direct Opening Force 120N min. Actuator Retention Force
(Note) Operating Frequency 900 operations per hour Rear Unlocking Button
Mechanical Durability
Mechanical Durability
Electrical Durability
Conditional Short-circuit Current
Cable
Weight (Approx.) 300g
Note: See page 16 regarding actuator retention force.
EN60947-5-1 (TÜV approval), UL508 (UL Listing CSA C22.2 No.14 (c-UL listed), GB14048.5
IEC60204-1/EN60204-1 (Applicable standards for use)
Voltage
2.5kV (between LED, solenoid and grounding: 0.5kV) Between live and dead metal parts: 100MΩ min.
Between terminals of different poles: 100MΩ min.
2
Operating extremes: 100m/s
2
(100G)
1000m/s Operating extremes: 10 to 55Hz, amplitude 0.35 min. Damage limits: 30Hz, amplitude 1.5mm min.
to
1.0m/s
11.0mm min. (Actuator: HS9Z-A51/A5P)
12.0mm min. (Actuator: HS9Z-A52/A51A/A52A/A53/ A55/SH5/SH5L)
24.5mm min. (Actuator: HS9Z-BA5)
Fzh = 1400N min. (GS-ET-19) However, Fzh=500N min. when HS9Z-A55 is used
3,000 times min. (HS5L-L)
2,000,000 times min. (Operation frequency 900 times/hour, actuator insert/ remove, solenoid operation) 100,000 times min. when HS9Z-SH5/SH5L (actuator insert/remove)
100,000 times min. (Operating Frequency: 900 operations per hour) 2,000,000 times min. (24V AC/DC, 100mA)
50A (250V) (Use 250V/10A fast-blow fuse for short­circuit protection.)
2
min. and 1.5mm2 max. or AWG22 min. to
0.3mm AWG16 max. strand wire or single wire
(10G), Damage limits:
),
(CCC approval)
Straight Actuator with Rubber Bushings
Marking for Locking Monitoring
The marking for lock monitoring described in clause 9.2.1 of ISO14119 can be used by satisfying the requirements in general requirements (5.7.1), locking monitoring (5.7.2.2), and ISO13849-1 (safety-related parts of control systems). This marking has been added to the 2013 edition of ISO14119. However, this marking cannot be applied to solenoid lock switches according to general requirement (5.7.1).
Ratings
Contact Ratings
Rated Insulation Voltage (Ui)
Rated Current (Ith) 2.5A
Rated Voltage (Ue)*
AC
(Ie)*
DC
Rated Current
•Minimum applicable load (reference): 3V AC/DC, 5mA (Applicable range may vary with operating conditions and load types.)
*
UL, c-UL rating: Pilot Duty AC 0.75A/250V, Pilot Duty DC 1.0A/30V TÜV rating: AC-15 0.75A/250V, DC-13 2.3A/30V CCC rating: AC-15 0.75A/250V, DC-13 2.3A/30V
Solenoid
Locking Mechanism Spring Lock Solenoid Lock Rated Voltage 100% duty cycle 24V DC Rated Current 200mA (initial value) Coil Resistance 120Ω (at 20°C) Pickup Voltage Rated voltage × 85% max. (at 20°C) Dropout Voltage Rated voltage × 10% min. (at 20°C) Maximum Continuous Applicable Voltage Rated voltage × 110% Maximum Continuous Applicable Time Continuous Insulation Class Class F
Indicator
Rated Voltage 24V DC Rated Current 10mA Light Source LED Illumination Color G (Green)
Straight Actuator
Right-angle Actuator
•Korean S Mark approval application pending
250V (between LED, solenoid and grounding: 30V)
30V 125V 250V Resistive Load (AC-12) Inductive Load (AC-15) 1.5A 0.75A Resistive Load (DC-12) Inductive Load (DC-13) 2.3A 0.55A 0.27A
2.5A 1.5A
2.5A 1.1A 0.55A
Adjustable actuator
(Bounce tolerant type)
10