IDEC FC4A-C24R Application Information

Application Note:
Etnernet Pass Through Configuration
System Setup
Before setting up your HG3/4Fs and PLCs, you need to decide which IP addresses
you will assign
configuration shown here:
to the HG3/4Fs. This document shows how to set up the system
HG3F
Network setting
IP address: 192.168.104.35 Subnet Mask: 255.255.255.0 Default Gateway: 192.168.104.254
Ethernet
PC
Network setting
WindO/I NV2 WindLDR
For more information please call 800-262-IDEC or email support@idec.com. 1
IP address: 192.168.104.100 Subnet Mask: 255.255.255.0 Default Gateway: 192.168.104.254
How to set up WindO/I NV2
(1) Confirm that you are using the latest version of WindO/I NV2. Open the
About WindO/I NV2 dialog box by selecting About from the Help menu. If the Version Number is 3.01 or later, you can use the Ethernet pass through function.
2 For more information please call 800-262-IDEC or email support@idec.com.
(2) Open the Project Settings dialog box and make sure all settings are properly
configured. Select the Communication Interface tab and left-click on Ethernet (as shown).
You will see the network settings of the HG interface. Verify that the network setting for the HG is correct.
For more information please call 800-262-IDEC or email support@idec.com. 3
Loading...
+ 4 hidden pages