Electrical Life500,000 operations minimum (at full rated load)
Mechanical Life5,000,000 (at no load)
Break Current24V/5A110V/1.2A220V/0.45A440V/0.20A
Make Current (A)Rated amperage x 1.1
CS Series
Operator
Series
ACSNO
Style
Cam
Angle
30º
45ºUp to 8
60ºUp to 6
90ºUp to 4
30ºUp to 12
Position
Up to 12
Maximum Contacts To Be
Mounted
1 to 10 decks;
Up to 20 contacts
YB, SB, PB, FB
Handle Styles
ACSNK
UCSQO
UCSQM
1. Do not use spring return (SR) for more than six contacts.
2. Two identical keys come with ACSNK unit. Specify “H” for handle key option.
45ºUp to 8
60ºUp to 6
90ºUp to 4
30ºUp to 12
45ºUp to 8
60ºUp to 6
90ºUp to 4
45º
Spring
return
Only 3
1 to 10 decks;
Up to 20 contacts
1 to 10 decks;
Up to 20 contacts
1 to 3 decks;
Up to 6 contacts
HB or
standard key
YB, SB, PB, FB
YB, SB, PB, FB
ø30mm - CS Series
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
Switches & Pilot Devices
Selector Switches (Assembled)
Assembled Selector Switches
ACSNO – 3 6 6 – ( ) SB – C3013
Series
ACSNO = Standard Cam Switch (30mm)
ACSNK = Key Cam Switch (30mm)
UCSQO = Cam Switch (5 hole mounting)
UCSQM = 3 Position Spring Return Cam
Switch (5 hole mounting)
Number of Levels (Decks)
1 through 10
Note: One level contains two independent contacts.*
Number of Positions
2 through 12
Angle
3 = 30° (12 position max)
4 = 45° (8 position max)
6 = 60° (6 position max)
9 = 90° (4 position max)
Contact Arrangement
1. For standard contact arrangements, use designations on page
642.
2. For custom contact arrangements,
omit contact arrangement designation and complete the blank
order form on page 777.
Handle
YB = Knob, Small
SB = Lever, Small
PB = Lever, Large
FB = Knob, Large
HB = Handle Key (ACSNK only)
Blank = Standard Key (ACSNK only)
Spring Return Action
Blank: Maintained
RO = Spring return from left
(3 or 4position, 45° only)
OR = Spring return from right
(3 or 4 position, 45° only)
RR = Return from right and left
(3 pos, 45° only)
1. *Contact blocks may contain two independent contacts, (a four position switch with four independent contacts only requires two contact blocks).
2. *Caution: switches with 180° or more of rotation may require separate blocks for each contact due to cam overlapping.
3. Key retainable in every 45º position (45, 90, 180, 225, 270, 315, 360).
Switches & Pilot Devices
3
1
4
2
123
7
5
3
1
8
6
4
2
12345
1 2 3
Contact Arrangements
Standard Arrangements
3
Terminal
Numbers
C-1001C-1002C-1014C-1005C-1008
3
3
4
1
2
1 2
4
1
2
1 2
3
1
1 2
C-2001C-2002C-2006C-2004C-2008C-2009C-2027
8
7
6
5
4
3
2
1
1 2
8
7
6
5
4
3
2
1
1 2
7
5
3
1
8
6
4
2
7
5
3
1
1 2 3
1
1 2
Position
Numbers
4
2
8
6
4
2
4
2
7
5
3
1
1 2 3 4
3
1
8
7
6
5
4
3
2
1
1 2 3 4
4
2
8
6
4
2
ø30mm - CS Series
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
C-3001C-3002C-3005C-3013C-3016
11
12
9
10
7
5
3
1
1 2
8
6
4
2
11
9
7
5
3
1
1 2 3
12
10
8
6
4
2
11
9
7
5
3
1
1 2 3
12
11
10
9
8
7
6
5
4
3
2
1
1 2 3 4 5 6
11
12
10
9
7
8
5
6
3
4
1
2
1 2 3 4 5
C-4001C-4002
15
13
11
9
7
5
3
1
1 2 3 4
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1 2 3 4 5 6 7 8
16
14
12
10
8
6
4
2
C-5001C-6001C-6002
19
17
15
13
11
9
7
5
3
1
20
23
18
21
16
19
14
17
12
15
10
13
8
11
6
9
4
7
2
5
3
1
1 2 3 4
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1 2 3 4 5 6 7 8 9 10 11 12
24
22
20
18
16
14
12
10
8
6
4
2
12
10
8
6
4
2
ø30mm - CS Series
Switches & Pilot Devices
Contact Arrangements continued
Ammeter Switching
C-1012C-4007
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
C-4003C-6003
CS
R S T
CT
E
O R S T
15
13
11
9
7
5
3
1
A
16
14
12
10
8
6
4
2
CT
CT
R S T
R S T
CS
O R S T
15
13
11
9
7
5
3
1
E
A
16
14
12
10
8
6
4
2
CS
O R S T
23
21
19
17
15
13
11
9
7
5
3
1
A
24
22
20
18
16
14
12
10
8
6
4
2
Voltmeter Switching
C-2022C-3008
CS
7
5
3
1
V
8
6
4
2
3ø-4W
R S T E
PT
C-3009C-3007
R S T E
PT
3ø-4W
CS
11
9
7
5
3
1
V
12
10
8
6
4
2
R S T
E
CS
OPTST TR
RS
11
9
7
5
3
1
V
12
10
8
6
4
2
Series
1
1
2
3
4
5
6
7
8
7
12
1
5
1
11
1
2
2
2
3
3
3
4
4
4
4
5
5
6
6
7
8
7
8
9
10
11
12
1
11
2
3
3
4
5
6
7
8
ACSNO
ACSNK
UCSQO
UCSQM
*Number of Decks
Specify Qty = 1, 2, 3, 4,
5, 6, 7, 8, 9, or 10
*Note: One Deck can drive two independent contacts.
Number of Positions
UnitAnglePositions
30° only9, 10, 11, 12
ACSNO
ACSNK*
UCSQO
UCSQM45° only3 only
30° or 45° only7 or 8
30°, 45° or 60°5 or 6
30°, 45°, 60°, 90° 2, 3, or 4
* ACSNK keys only remove at 45°.
Switches & Pilot Devices
Order Form (Custom Contact Arrangement)
( )
HandleACSNO, UCSQO, UCSQM:
YB = Knob, Small
SB = Lever, Small
PB = Lever, Large
FB = Knob, Large
ACSNK:
HB = Handle Key (option)
Blank = Standard Key
Angle
3 = 30º
4 = 45º
6 = 60º
9 = 90º
Spring Return
Blank = Maintained
RO = Spring return from left
(3 or 4 position, 45º)
OR = Spring return from right
(3 or 4 position, 45º)
RR = Return from right and left
(3 position, 45º)
UCSQM is available in spring-return
version only.
ø30mm - CS Series
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
For handle styles, see page 778.
Contact Arrangement Table
Cams
Deck 1
Deck 2
Deck 3
Deck 4
Deck 5
Deck 6
Deck 7
Deck 8
Deck 9
Deck 10
Terminal
Numbers
123456789101112
1 and 2
3 and 4
5 and 6
7 and 8
9 and 10
11 and 12
13 and 14
15 and 16
17 and 18
19 and 20
21 and 22
23 and 24
25 and 26
27 and 28
29 and 30
31 and 32
33 and 34
35 and 36
37 and 38
39 and 40
To specify non-standard arrangements (designation not on preceding pages), ll in this table using the following symbols.
X = Closed contact (break before make) O = Open contact
X X
= Overlapping contact (remain on when switch is moved between two positions)
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
Part NumberCSH-YBCSH-SBCSH-PBCSH-FBCSH-H2B
Dimensions0.79”D x 1.61”H0.79”D x 1.97”H1.58”D x 1.97”H1.58”D x Ø 1.97”0.95”D x 2.28”H
Applicable ModelsACSNO, UCSQO, UCSQMACSNK
Replacement Nameplates
Size & Shape
q 2.52” (64mm)
Black Aluminum
Part NumberCQCQMCQN
Applicable ModelsUCSQOUCSQMACSNO, ACSNK
1. Extra cost for engraving, 3/16” min. letter height, Legends maximum ten characters.
2. Blank nameplates are supplied with all cam switches (they need not be ordered separately).
Wiring Clips
Part NumberContact Block Jumpers
CJ-1
Between decks
CJ-2
Same deck
Replacement Keys
Part NumberDescription
K301
Pair of keys (#301)
Switches & Pilot Devices
47
R0.8 max.
N: Number of Contact Blocks
4-M4 Screw
Panel Thickness 7.0 max.
46.4
Dimensions/Terminal Arrangements/Mounting Holes
ø30mm - CS Series
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ACSNO
ACSNK
UCSQO
M3.5 Terminal Screw
52
29
47
* Spring Return: 44
M3.5 Terminal Screw
52
2
47
46.4
M3.5 Terminal
Screw
* Spring Return: 44
12
12N+9
Maintained: 42
N: Number of Contact Blocks
12
9
12N+9
Maintained: 42
N: Number of Contact Blocks
52
2
*
*
9 12
12N+9
* Spring Return: 31
Maintained: 29
*7
Panel Thickness 0.8 to 6
)
52
50
S2 Handle
(
30.7
Panel Thickness 0.8 to 6
52
30
35
Panel Thickness
7.0 max.
41
(Y2 Handle)
25
47
4-M4 Screw
64
Terminal
Arrangement
47
Mounting Holes
+0.2
0
4.8
0
+0.5
33
48
70
+0.5
ø30.5
0
(
ACSNO/ACSNK
)
UCSQM
M3.5 Terminal
Screw
52
2
9
12
12N+9
31
N: Number of Contact Blocks
UCSQO
64
50
P2 Handle)
(
7
43
48
70
UCSQM
4-ø4.5
ø13
48
48
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.