Page 2
#61-744
#61-746
600 AAC Clamp Meter
Instruction Manual
NCV
OFF
V
Ω
V
True RMS
40
A
600
AM
HOLD
DC
KACmΩ V
APO
CAT.III
600V
600A
CLAMP
61-746
CAT.III
600V
V/Ω
COM
WARNING
Read First: Safety Information
Understand and follow operating instructions carefully. Use the meter only as
specified in this manual; otherwise, the protection provided by the meter may be
impaired.
WARNING
To avoid possible electric shock, personal injury or death, follow these
guidelines:
• Do not use if meter appears damaged. Visually inspect the meter to ensure
case is not cracked and back case is securely in place.
• Inspect and replace leads if insulation is damaged, metal is exposed, or probes
are cracked. Pay particular attention to the insulation surrounding the
connectors.
• Do not use meter if it operates abnormally as protection maybe impaired.
• Do not use during electrical storms or in wet weather.
• Do not use around explosive gas, dust, or vapor.
• Do not apply more than the rated voltage to the meter.
• Do not use without the battery and the back case properly installed.
• Remove the test leads from the circuit prior to removing battery cap.
• Do not attempt to repair this unit as it has no user-serviceable parts.
• Replace batteries as soon as low battery indicator appears to avoid false
readings.
• Comply with local and national safety requirements, including the use of
appropriate personal protective equipment.
ND 6442-1 61-744 61-746 Instructions 11/13/07 7:30 AM Page 1
+
NCV
OFF
V
Ω
V
True RMS
40
A
600
AM
HOLD
DC
KACmΩ V
APO
CAT.III
600V
600A
CLAMP
61-746
CAT.III
600V
V/Ω
COM
Features
1. Jaw Clamp
2. Lever
3. Function Dial
4. Display (LCD)
5. Volts and resistance (V-Ω)
input terminal
6. Common (COM) input terminal
7. Non-Contact Voltage (NCV)
8. Range ( )
9. Data Hold
10. Measuring Functions
Display Icons
11. 4000 count display
12. Units of measure
13. Voltage
14. Amperes
15. Ohms
16. Continuity
17. AC measurement is selected
18. DC measurement is selected
19. Polarity indicator for DC
20. Low battery indicator
21. Range ( )
22. Data hold
23. APO - Auto Power Off
Symbols on the Unit
• Warning - read the instruction manual
• NCV - Non-Contact Voltage
• Cat III - 600V Safety category
1
9
3
8
4
5
10
6
11
16
14
12
13
15
7
2
20
21 22 23
17
18
19
Page 3
CAUTION
To protect yourself, think "Safety First":
• Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution.
• Use appropriate personal protective equipment such as safety glasses, face
shields, insulating gloves, insulating boots, and/or insulating mats.
• Before each use:
- Perform a continuity test by touching the test leads together to verify the
functionality of the battery and test leads.
- Use the 3 Point Safety Method. (1) Verify meter operation by measuring a
known voltage. (2) Apply meter to circuit under test. (3) Return to the
known live voltage again to ensure proper operation.
• Never ground yourself when taking electrical measurements.
• Connect the black common lead to ground or neutral before applying the red
test lead to potential voltage. Disconnect the red test lead from the voltage
first.
• Always work with a partner.
• When using the probes, keep fingers as far behind the probe tips as possible.
Features:
• Auto/manual ranging clamp meter
• Non-Contact Voltage (70-600VAC)
• Measures 600 AAC Current
• Measures AC/DC Voltage and Resistance
• Audible continuity
• Data hold
• Auto Power Off
• Low Battery Indicator
• Compact jaws for reaching into tight spaces
• Electronic overload protection on all ranges
• 61-744 model is averaging sensing, rms calibrated
• 61-746 model is true rms sensing.
ND 6442-1 61-744 61-746 Instructions 11/13/07 7:30 AM Page 3
NCV
OFF
V
Ω
V
True RMS
40
A
600
AM
HOLD
DC
KACmΩ V
APO
CAT.III
600V
600A
CLAMP
61-746
CAT.III
600V
V/Ω
COM
CORRECT
Use with
line splitter
INCORRECT
Currents
cancel
CORRECT
Single
Conductor
only
AC Voltage DC Voltage
NCV
OFF
V
Ω
V
True RMS
40
A
600
AM
HOLD
DC
KACmΩ V
APO
CAT.III
600V
600A
CLAMP
61-746
CAT.III
600V
V/Ω
COM
Measuring AC Current (Amps):
Measuring Voltage:
OPERATION:
Non-contact voltage (NCV)
With the NCV tab on the tip of the clamp close to an AC voltage, press the NCV button. The NCV LED will light and the beeper will sound. The closer the NCV tab is to
AC voltage, the louder the beep. To differentiate between hot and neutral in an outlet,
insert the NCV tab into each slot in the outlet. The beeper will be much louder on
the hot side of the outlet than the neutral. The test lead can also be used to differentiate between the hot and neutral. Plug the red test lead into the V/Ω input jack on
the meter. Press the NCV button and insert the probe tip into each slot of the outlet.
The beeper will only beep on the hot side of the outlet.
Auto/Manual Ranging Mode ( )
The meter defaults to autoranging mode when powered on. In this mode, the meter
automatically selects the best range to display the measurement. By pressing the
Range ( ) button on the meter, the manual range mode will override the autoranging feature of the meter. A ( ) appears in the upper left side of the display.
Continue pressing the Range button until the desired range is obtained. Use this
mode to lock in a specific range for repeated measurements. To return to the
autoranging mode, either depress the Range button for greater than 1 second or turn
the meter off and then back on again.
Data Hold Feature
Press the Hold button on the side of the meter to toggle in and out of the data hold
mode. “HOLD” appears in the upper left of the meter display when data hold is
active. Use the data hold feature to lock a measurement reading on the display.
Press the Hold button again to unlock the display and obtain a real-time reading.
Auto Power Off (APO) Feature
The meter automatically powers itself down after about 10 minutes of no use. Press
any button, and the meter will wake up and display the last reading taken before
power down. This feature can be overridden by holding the Range ( ) button
while turning the function switch from Off to any other position. When APO is
defeated, the “APO” will be removed from the display. Turning the meter off will
restore the APO default.
H
N
NCV
OFF
V
Ω
V
True RMS
40
A
600
AM
HOLD
DC
KACmΩ V
APO
CAT.III
600V
600A
CLAMP
61-746
CAT.III
600V
V/Ω
COM
ND 6442-1 61-744 61-746 Instructions 11/13/07 7:30 AM Page 5
600V
CLAMP
CAT.III
600A
V
61-746
V
Ω
40
A
600
OFF
NCV
DC
KACmΩ V
COM
True RMS
HOLD
APO
AM
V/Ω
CAT.III
600V
600V
CLAMP
CAT.III
600A
V
61-746
V
Ω
40
A
600
OFF
NCV
True RMS
HOLD
APO
DC
AM
KACmΩ V
V/Ω
COM
CAT.III
600V
Page 7
Page 8
Verifying Continuity ( ):
• Verify the circuit is de-energized.
• The meter will sense the level of
resistance and beep if the resistance
is less than 25Ω to confirm that
continuity is present.
Closed
Circuit
Open
Circuit
Battery Replacement:
• Ensure test leads are disconnected from
circuit or components.
• Remove test leads from input jacks
on meter.
• Remove the two screws from the
battery cap.
• Remove the battery cap.
• Replace batteries with two
"AAA" batteries.
• Assemble the battery cap
to the meter and re-tighten
the screws.
Maintenance:
• Clean the case with a damp cloth and mild detergent. Do not use abrasives or
solvents.
Service and Replacement Parts:
This unit has no user-serviceable parts.
For replacement parts or to inquire about service information contact IDEAL
INDUSTRIES, INC. at 1-877-201-9005 or visit our website
www.testersandmeters.com.
Measuring Resistance (Ohms):
• Verify the circuit is de-energized to obtain accurate measurements.
ND 6442-1 61-744 61-746 Instructions 11/13/07 7:30 AM Page 7
600V
CLAMP
CAT.III
600A
V
61-746
V
Ω
40
A
600
OFF
NCV
True RMS
HOLD
APO
DC
AM
KACmΩ V
COM
V/Ω
CAT.III
600V
600V
CLAMP
CAT.III
600A
V
61-746
V
Ω
40
A
600
OFF
NCV
True RMS
HOLD
APO
DC
AM
KACmΩ V
COM
V/Ω
CAT.III
600V
600V
CLAMP
CAT.III
600A
61-746
40
A
NCV
DC
COM
V
Ω
600
OFF
True RMS
HOLD
KACmΩ V
V
APO
AM
V/Ω
CAT.III
600V
ND 6442-1 61-744 61-746 Instructions 11/13/07 7:30 AM Page 9
Specifications:
Display: 3-3/4 digit LCD with 4000 counts
Polarity: Automatic, positive implied, negative (-) polarity indication.
Overrange: "OL" indication is displayed.
Measure Rate: Samples 2 times per second, nominal.
Auto Power Off: Approximately after 10 minutes of non-use.
Battery Life: 400 hours continuous with Alkaline (61-744)
250 hours continuous with Alkaline (61-746)
Low Battery Indication: The " " is displayed when battery voltage drops below
+
operating level.
Power Supply: (2) 1.5V "AAA" batteries (NEDA R03).
Includes an isolated battery compartment.
Accuracy: Stated accuracy at 23°C ±5°C, <75% R.H.
Temperature 0.1 x (specified accuracy) per °C,
Coefficient: (0°C to 18°C, 28°C to 50°C).
Altitude: 6561.7 ft. (2000m)
Operating Environment: 32°F to 122°F (0°C to 50°C) at < 70% R.H.
Storage Environment: -4°F to 140°F (-20°C to 60°C) at < 80% R.H.
Jaw Opening: Accepts a 1.50" (38mm) conductor
Dimensions: 8.0"H x 2.6"W x 1.5"D (203mm H x65mm W x37mm D)
Weight: 7.1 oz (200g) including batteries
Accessories included: Carrying Case, Test Leads, (2) 1.5V "AAA" batteries,
operating instructions.
Safety: Complies with UL/IEC/EN: 61010-1, 61010-2-032,
61010-031 specifications, Cat III-600V.
CUS
N12966
Double Insulation
Instrument has been evaluated and complies with insulation category III (overvoltage
category III). Pollution degree 2 in accordance with IEC-644. Indoor use.
Ranges & Accuracies:
AC Converter:
61-744 model is averaging sensing, rms calibrated
61-746 model is true rms sensing.
Accuracy:
Accuracy is specified as +/-(a percentage of the reading + a fixed amount) at
23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity.
Temperature Coefficient: 0.1 times the applicable accuracy specification per
degree C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F)
Function
AC Current*
AC Voltage
DC Voltage 400.0V/600V 0.5% + 2 digits 600 VDC or AC rms
Resistance
Continuity
Range and Overload
Resolution
40.00A//400.0A/600.0A (50Hz - 60Hz) 1.7% + 6 digits 1.7% + 10 digits
40.00A/400.0A/600.0A (60Hz - 400Hz) 3.0% + 6 digits 3.0% + 10 digits
400.0V (50Hz - 500Hz) 1.2% + 5 digits 1.2% + 8 digits
600V (50Hz - 500Hz) 1.5% + 5 digits 1.5% + 8 digits
400.0Ω/4.000kΩ/40.00kΩ/
400.0k Ω
4.000MΩ 1.5% + 4 digits
40.00MΩ 3.0% + 5 digits
Audible indication < 25Ω
Response time: 500ms
Accuracy
61-744 61-746
1.0% + 4 digits
N/A 600 VDC or AC rms
Protection
600AAC
600 VDC or AC rms
600 VDC or AC rms
* Accuracy stated for crest factor ≤ 3
Input Impedance is 10MΩ.
Page 9 Page 10
#61-744
#61-746
Medidor de pinza
Manual de Instrucciones
NCV
OFF
V
Ω
V
True R MS
40
A
600
AM
HOLD
DC
KACmΩ V
APO
CAT.III
600V
600A
CLAMP
61-746
CAT.III
600V
V/Ω
COM
Warranty Statement:
This tester is warranted to the original purchaser against defects in material and
workmanship for two years from the date of purchase. During this warranty period,
IDEAL INDUSTRIES, INC. will, at its option, replace or repair the defective unit,
subject to verification of the defect or malfunction.
This warranty does not cover fuses, batteries or damage from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument.
Any implied warranties arising out of the sale of an IDEAL product, including but
not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use
of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic
loss.
State laws vary, so the above limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.
Page 11
Page 12
ND 6442-1 61-744 61-746 Instructions 11/13/07 7:30 AM Page 11