IDEAL Electrical 61-340, 61-342 Instruction Sheet

AC Voltage (V~)
#61-340 #61-342
Digital Multimeter Instruction Manual
Read First: Safety Information
Understand and follow operating instructions carefully. If this tester is not used in a manner specified by IDEAL, protection provided by the product may be impaired.
WARNINGS
To avoid possible electric shock, personal injury or death follow these instructions:
• Do not use if meter appears damaged.
• Visually inspect the meter to ensure case is not cracked and back case is securely in place.
• Inspect and replace leads if insulation is dam­aged, metal is exposed, or probes are cracked. Pay particular attention to the insulation sur­rounding the connector.
• Do not use meter if it operates abnormally as protection maybe impaired.
• Do not use during electrical storms or in wet weather.
• Do not use around explosive gas, dust, or vapor.
• Do not apply more than the rated voltage to the meter.
• Do not use without the battery and the back case properly installed.
• Remove the test leads from the meter before removing battery cap.
• Do not attempt to repair this unit as it has no user-serviceable parts.
• Disconnect power and discharge capacitors before testing resistance, continuity, diodes, capacitance or temperature.
• Replace battery as soon as low battery indicator
appears to avoid false readings.
• Use the proper terminals, function and range for your measurements.
• Comply with local and national safety requirements, including the use of appropriate personal protective equipment.
CAUTION:
To protect yourself, think "Safety First":
• Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution.
• Use appropriate personal protective equipment such as safety glasses, face shields, insulating gloves, insulating boots, and/or insulating mats.
• Before each use:
- Perform a continuity test by touching the test leads together to verify the functionality of the battery and test leads.
- Use the 3 Point Safety Method. (1) Verify meter operation by measuring a known voltage. (2) Apply meter to circuit under test. (3) Return to the known live voltage again to ensure proper operation.
• Never ground yourself when taking electrical measurements.
• Connect the black common lead to ground or neutral before applying the red test lead to potential voltage. Disconnect the red test lead from the voltage first.
• Always work with a partner.
• When using the probes, keep fingers as far behind the probe tips as possible.
Ranges & Accuracies:
AC Converter: 61-340 model is averaging
sensing, rms calibrated; 61-342 model is true rms sensing. Accuracy: Accuracy is specified as +/-(a percentage of the reading + a fixed amount) at 23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity. Temperature Coefficient: 0.1 times the applicable accuracy specification from 32°F to 64°F and 82°F to 122°F (0°C to 18°C ; 28°C to 50°C).
Ranges & Accuracies
DC Voltage (V )
Toggle for Frequency (>20% of range)
Function Range & Resolution Accuracy Overload Protection
DC Voltage
400.0m/4.000/40.00/400.0 V ±(0.5%+5)
600.0V ±(1.0%+3)
AC Voltage
400.0m/4.000/40.00/400.0/600 V ±(1.5%+5)
(40~400Hz)
DC Current
400.0/4000 µA ; 40.00/400.0 mA ±(0.5%+5) 500mA/600V Fast Fuse
4.000/10.00 A ±(1.5%+5) 10A/1000V Fast Fuse
AC Current
400.0/4000 µA ±(1.5%+5)
500mA/600V Fast Fuse
(40~400Hz)
40.00/400.0 mA ±(2.0%+5)
4.000/10.00 A ±(2.5%+5) 10A/1000V Fast Fuse
400.0 ±(1.2%+5)
Resistance
4.000k/40.00k/400.0k ±(1.0%+2)
600V DC/AC rms
4.000M ±(1.2%+2)
40.00M ±(2.0%+5)
40.00nF ±(3.0%+10)
Capacitance* 400.0n/4.000µ/40.00µF ±(3.0%+5) 600V DC/AC rms
400.0µ/4000µ F ±(20%+5)
Frequency 10.00/100.0/1.000k/10.00k/100.0k/1.000M/10.00M Hz
±(0.1%+3)
600V DC/AC rms
Sensitivity: <1MHz: 0.7Vrms ; >1MHz: 5Vrms
Duty Cycle 0.1 - 99.9% ±(2.5%+5) (<10kHz)
Diode Check Test current : (1±0.6) mA and then open circuit voltage is 2.5VDC typical. 600V DC/AC rms
Continuity The beeper turns on <25and turns off at >120. 600V DC/AC rms
Temperature**
-58~1500°F
±(3.0%+5)
-50~800°C
±(3.0%+3)
*Accuracy not available for <10nF capacitance. **Accuracy is stated for meter only. Thermocouple accuracy adds another ±2.5% to reading.
Input Impedance : 10Mfor VAC &VDC. CF > 2, add ±1.0% to accuracy.
900VDC
750VAC rms
~
Symbols
Risk of electric shock See instruction card DC measurement Equipment protected by double or
reinforced insulation Battery Earth AC measurement Conforms to EU directives
+
+
DC
AC/DC Current (A )
Specifications
General Features Display: 3999 Count LCD / 3-3/4 Digit Refresh Rate: 2.5x/sec. Over range: “OL” is displayed Polarity: Automatic (no indication for
positive polarity); Minus(-) sign for negative polarity
True-RMS: 61-342 only. Auto Power Off: After 10 minutes of non-use Low Battery: is displayed if battery voltage
drops below operating voltage
Altitude: 6561.7 ft. (2000m) Accuracy: Stated accuracy at 73° ±41°F
(23° ±5°C), < 75% R.H.
Batteries: 9VDC NEDA 1604 Battery Life: 200 hrs. (61-340)
150 hrs. (61-342)
Fuse: 0.5A/500V (#F-340)
10A/1000V (#F-341)
Operating 32°to 104°F (0° to 40°C) environment: at < 75% R.H. Storage -4° to 140°F (-20° to 60°C) environment: at < 80% R.H. Weight: 13.6 oz (386g) Size: 7.0"H x 3.5"W x 1.9"D
(177mmHx89mmWx48mmD)
Accessories Test leads (TL-310), 9V battery, Included: Operating Instructions Safety Complies with UL/IEC/EN 61010-1, Certification: 61010-031, Cat III-600V
Equipment protected by double insulation.
Instrument has been evaluated and complies with insulation category III (overvoltage category III) for measurements performed in the building installation. Pollution degree 2 in accordance with IEC-644. Indoor use.
CUS
N12966
Maintenance
Clean the case with a damp cloth and mild deter­gent. Do not use abrasives or solvents.
Service and Replacement Parts
No user-serviceable parts. For replacement parts or to inquire about service
information contact IDEAL INDUSTRIES, INC. at 1-877-201-9005 or visit our website @ www.testersandmeters.com.
Warranty Statement
This tester is warranted to the original purchaser against defects in material and workmanship for two years from the date of purchase. During this warranty period, IDEAL INDUSTRIES, INC. will, at its option, replace or repair the defective unit, sub­ject to verification of the defect or malfunction.
This warranty does not cover fuses, batteries or damage from abuse, neglect, accident, unautho­rized repair, alteration, or unreasonable use of the instrument.
Any implied warranties arising out of the sale of an IDEAL product, including but not limited to implied warranties of merchantability and fitness for a par­ticular purpose, are limited to the above. The man­ufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or eco­nomic loss.
State laws vary, so the above limitations or exclu­sions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
WARNING: To avoid electric shock, dis-
connect test leads before removing battery cover.
WARNING: For continued protection against fire, replace only with fuses of the speci­fied voltage, current and rupture speed ratings.
Diode Test ( )
Frequency (Hz) /
Duty Cycle(%)
WARNING: De-energize circuit first.
WARNING: De-energize circuit before
checking diode.
Note: On noisy circuits, turn dial to V, then toggle Hz button.
WARNING: To avoid electric shock, do not place test leads or thermocouple on a voltage source.
~
Toggle for AC
Toggle for Hz
Toggle for
)
)
)
Toggle for
Reverse
Audible Continuity (
)
)
)
)
Temperature
Data Hold
Hold
Press to hold
present value in
display; depress to
release display.
Min/Max
Relative Mode
Toggle for
Relative Mode
Press to deduct
reference value;
depress to exit
mode.
Backlight
Press >1 sec. for backlight ( )
Backlight stays illuminated for 10 sec.
Range
Toggle to manual
range on following
functions: Volts,
Ohms, Amps.
Hold for >1sec. to
exit mode.
Turn power off, break circuit, insert meter in series, then turn power back on.
WARNINGS:
• Check fuse for continuity before testing.
• Use the proper switch position and lead inputs.
• Never attempt to measure current on circuits or equipment with more than 600 volts potential.
• Duty cycle: 15sec ON / 15min OFF for
10A MAX
Toggle for °C
Toggle for Duty Cycle
Toggle for Min/Max
Hold for >1sec. to exit mode.
MAX MIN
Capacitance ( )
WARNING: De-energize circuit before
taking resistance measurement.
WARNING: De-energize circuit and discharge capacitor before taking capaci­tance measurement. Measuring time: < 15sec for <400µF
< 1min for <4000µF
Resistance (Ω)
Toggle for
Battery & Fuse Replacement
~
MΩ
nF
DC
A
Ω
Closed Circuit
Bad Diode
Open Shorted
Good Diode
Foward Reverse
Open
Circuit
+
Hz
(Remove tilt stand)
+