Order Code: POINTE-12R
User Manual
All the products' information accord to the actual lightings' collocation. We will not
inform else if any change. We reserve the final interpretation right.
Professional Moving Head Beam Spot Wash 3in1

Professional Moving Head Beam Troubleshooting
3.1 Control Panel
3.2 DMX Control
Professional Moving Head Beam Fixture Cleaning
5. Fixture Cleaning
● Clean with soft cloth using normal glass cleaning fluid.
●Always dry the parts carefully.
The cleaning of internal and external optical lenses and/or mirrors must be carried
out periodically to optimize light output. Cleaning frequency depends on the
environment in which the fixture operates: damp, smoky or particularly dirty
surrounding can cause greater accumulation of dirt on the unit’s optics.
●Clean the external optics at least every 20 days. Clean the internal optics at
least every 30/60 days.
Contents
1. Safety Instruction
Following are a few common problems that may occur during operation.
Here are some suggestions for easy troubleshooting:
A. The unit does no work, no light
1. Check the connect power and mains fuse.
2. Measure the mains voltage on the main connector.
B. Not responding to DMX controller
1. Check DMX connectors, cables to see if they are linked properly.
2. Check the address settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on the connectors
or on PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check to see if the DMX cable run near or run alongside to high voltage cables
that may cause damage or interference to DMX interface circuit.
2. Technical Specfication
3. How to Control the Package
3.2.1 DMX 512 Configuration
3.2.2 DMX 512 Connection

Professional Moving Head Beam DMX 512 Connection Professional Moving Head Beam Safety
Safety Instructions:
Every person involved with the installation, operation and maintenance should:
A001 A017 A033 A049 ● Be competent
A001 A025 A049 A073 ● Follow the instructions of this user manual
Make sure there are not flammable materials close to the unit while operating
Damages caused by user modifications to the unit are not subject to warranty.
4 1
Termination reduces signal errors and to avoid signal transmission problems and
interference. It is always advisable to connect a DMX terminal.
(Resistance 120ohm 1/4W) between pin2(DMX-) and pin3(DMX+) of the last
fixture.
1.If you use a controller with 5 pins DMX output, you have to use a 5 to 3 pin adaptercable.
2.At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in
the DMX-output of the last unit.
Please find the following examples to address your DMX512 channel for the
first 4 packages.
Caution
Take care using this equipment!
High voltage risk of electric shock.
Before your initial star-up, please make sure that there is no damage caused
during transportation. Should there be any, consult with the dealer and do not use
the unit.
16CH Mode:
24CH Mode:
Please keep this User Manual for future consultation. If you sell the unit to
another user, be sure that they also receive this instruction booklet.
To maintain the equipment in good work condition and to ensure safe operation, it
is necessary for the user to follow the safety instructions and warning notes
written in the manual.
For your own safety, please read this user manual before operation.
Use universal DMX controller to control the packages, you have to set the DMX
address from 1 to 512 channels so that the unit can receive the DMX signal.
Caution
Before operating,make sure the voltage and frequence
of the power supply match the power requirements of the package.
When switch on the lighting, LB280 is showing on the lighting, press E button to
enter into menu, use the TOUCH SCREEN directly or UP and DOWN to
choose the submenu AXXX to set the address. Once the address has been
selected, press ENTER button to store.

Professional Moving Head Beam Technical Specifations Professional Moving Head Beam Control Panel
You should find the following items inside the carton packing:
Technical Specifations
Voltage: AC110-240V,50/60HZ
Lamp: OSRAM P-VIP 280W lamp
Professional Moving Head Beam DMX 512 Configuration
Power consumption: 450W
Lens: high precision optical lens
Pan: 540degree (16bit) Tilt: 270degree (16bit)
Color Wheel: 13 colors + open, with rainbow effect
Rotating Gobo Wheel: 9 bidirectional & indexable gobos + open
Gobo Wheel: 14 gobos (with gobo shaking/gobo flow)+ open
Prism: 8-facet circular Rotating Prism & 6-facet linear Rotating Prism
Other Functions: ZOOM, Wash, Focus, Dimmer, Strobe
Packing Size: 725*440*790mm Gross Weight: 56kg (2in1 flight case)
Operation Modes: ● DMX mode: 16CH/24CH ● Master/Slave mode ● Auto
Professional Moving Head Beam Control Panel
LCD display (Touch Screen): Showing the menus and selected function
Control Pannel / ENTER:
Mains input: Power in
DMX input / output: Use 3-pin XLR cable to link items together
Switch ON/OFF
2pc Moving Head, 2set OMEGA clamps, 2pc power cable, 2pc DMX cable,
1pc User Manual
1. A001 DMX Address Setting 2. Rpan Pan Reverse
3. Rtil Tilt Reverse 4. MODE Control Mode Setting: DMX: 16CH/24CH; AUTO; SOUD
5. DISP Display Reverse 6. LAMP Lamp ON/OFF
7. REST Reset 8. OPTO Optical Sensor Correction