The Ideal Mexico is a range of cast iron floor standing gas central heating boilers. Both balanced or conventional flue versions are available. A complete range of both natural gas and propane models. The range offers Super models and, for when space is tight, there are Slimline models available.
Mexico: Britain’s biggest selling floor standing boiler
The ideal replacement boiler...
Easy to install, easy to operate and easy to service. The Ideal Mexico really is the ultimate replacement floor standing range - you can depend on it.
Proven reliability...
Proven cast iron heat exchanger engineered and refined to be the most dependable floor standing boiler ensuring totally calm operation and quiet running, whatever the system demands.
Complete range...
27 models, including 4 Slimline models at only 250mm wide and 8 propane Super models. Option kit availability includes an easy to use programmer kit available on all models, an overheat thermostat kit for all models and a pump kit that can be housed within the casing, available for all models except the Super CF 3/140 & CF 3/140P.
Full system suitability...
All models are suitable for connection to pumped open vent central heating systems, pumped central heating combined with pumped or gravity indirect domestic hot water supply systems. They can also be used on sealed water systems when used in conjunction with the optional Overheat Thermostat Kit.
Free Guarantee: 1st Year Ideal Care
The home owner is entitled to 12 months free Ideal Care, which includes both parts and labour, to restore the boiler to full function. Please encourage the home owner to complete and return the registration form in their Householder’s pack within 30 days of installation.
Optional Extra Year Cover with Ideal Care
You may wish to offer your own annual service plan or you may wish to advise the home owner to complete their application form for the appropriate level of extended Ideal Care - Silver, Gold or Platinum. Full details are available in the Ideal Care brochure.
Page 3
3
Mexico Super RS & CF Propane - Users
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components
Mexico Super (Propane Models Only)
Introduction
It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.
Gas safety (Installation & Use) Regulations 1994, amendments 1996 or rules in force.
In your own interest, and that of safety, it is the law that this boiler must be installed by a registered installer, in accordance with all national and local regulations.
Electricity Supply
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz.
The fusing should be 3A.
Connection must be made in a way that allows complete isolation of the electrical supply such as a double pole switch having a 3mm (1/8") contact separation in both poles, or a plug and socket, serving only the boiler and system controls. The means of isolation must be accessible to the user after installation.
Important notes
a. If the boiler is installed in a compartment then the compartment
MUST NOT be used for storage purposes.
b. The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically that the ventilation areas are free from any obstruction.
c. If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a CORGI registered installer.
d. Inflammable materials must not be placed in close proximity to
the appliance. Materials giving off flammable vapours must not be stored in the same room as the appliance.
e. Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.
TTB Downdraught thermostat
(CF boilers only)
This appliance is fitted with a TTB downdraught thermostat for added safety and protection. If this thermostat should operate and switch off the appliance it is because the flue is subject to downdraught, probably as a result of adverse wind conditions.
The TTB is an automatic reset thermostat which will reset once wind conditions have returned to normal, subject to a built-in reset delay in excess of 10 minutes.
The TTB is an IMPORTANT SAFETY DEVICE and MUST NOT be put out of action or interfered with in any way.
The TTB is not a substitute for an independently mounted carbon monoxide detector.
In cases of repeated or continuous shutdown a CORGI registered installer should be called to investigate and rectify the condition causing this and carry out an operational test after each intervention on the device. Only the manufacturer's original parts should be used for replacement.
Minimum clearances
A clearance of 533mm (21") MUST be available at the front of the boiler for servicing.
The minimum clearances given in Table 1 MUST be complied with, in order to maintain the safe running of the boiler.
Mexico Super CF 3/60P ......... G.C. No. 41 348 99
Mexico Super CF 3/75P ......... G.C. No. 41 349 23
Mexico Super CF 3/100P ....... G.C. No. 41 349 24
Mexico Super CF 3/125P ....... G.C. No. 41 349 25
Mexico Super CF 3/140P ....... G.C. No. 41 349 26
Mexico Super RS 3/60P ......... G.C. No. 41 349 34
Mexico Super RS 3/75P ......... G.C. No. 41 349 35
Mexico Super RS 3/100P ....... G.C. No. 41 349 36
Destination Countries: GB, IECertified - P.I. No. RS ....... 87 AT 14 CF .......... 87 AT 15
Page 4
4
Mexico Super RS & CF Propane - Users
Table 1
Minimum Minimum
Boiler A or BA + B
mm (ins.) mm (ins.)
CF 3/60P & 3/75P 10 (
3/8) 110 (4 1/2)
CF 3/100P 35 (1 3/8) 135 (5 1/4)
CF 3/125P 50 (2) 210 (8 1/4)
CF 3/140P 150 (6) 300 (12)
all RS models 10 (3/8) 20 (
3/4)
1
BOILER CLEARANCES
To light the boiler.
Refer to Frame 2
If a programmer is fitted refer to separate instructions for the programmer before continuing.
1. Check that the electricity supply to the boiler is OFF.
2. Remove the lower front panel by pulling it forward and lifting
out.
3. Open the control panel drop-down door and ensure that the thermostat knob (A) is in the OFF position.
4. Turn the gas control knob (B) to the RIGHT until resistance is felt and then release it.
Wait for 3 minutes.
5. Push in and retain fully depressed the gas control knob (B). Press and release the ignition button (C) repeatedly until the pilot flame can be seen through the sight glass (D). When the pilot has lit, continue to press in the gas control knob (B) for a further 15 seconds.
6. Should the pilot go out at this or any other stage, turn the gas control knob (B) CLOCKWISE and release it. Wait for 3 minutes then repeat instruction 5 - but wait longer than 15 seconds before releasing the gas control knob.
7. Switch ON the electricity supply to the boiler and check that all external controls, e.g. room thermostat etc., are ON.
8. Turn the boiler thermostat knob (A) to position 6 and the boiler will light. Set the boiler thermostat to the desired setting.
9. Refit the lower front panel by locating the bottom edge behind the top of the grille assembly and pushing the panel backward to engage in the upper clips.
Winter conditions (i.e. central heating and domestic hot water).
The thermostat should be positioned at setting 5 or 6.
Summer conditions (i.e. domestic hot water only). The thermostat should be positioned at setting 2.
These settings are offered for general guidance only and other settings may be found preferable, dependent upon the type of
system installed or as recommended by the installer.
To shut down the boiler
1. For short periods
Turn the boiler thermostat knob (A) to OFF. When heating is again required, restore the knob to its original setting.
2. For longer periods
a. Turn the boiler thermostat knob (A) to OFF.
b. Turn the gas control knob (B) CLOCKWISE until
resistance is felt then release it to extinguish the pilot burner.
c. Switch the electricity supply to OFF.
Frost protection
If no frost protection is provided and frost is likely during a short absence from home, leave the heating controls (if fitted) at a reduced temperature setting.
For longer periods, the entire system should be drained - including the domestic water supply.
If the system includes a frost thermostat then, during cold weather, the boiler should be turned OFF at the time switch (if fitted) ONLY. The mains supply should be left switched ON, with the boiler thermostat left in the normal running position.
THE LOG BOOK SHOULD BE COMPLETED AFTER
EACH SERVICE AND KEPT WITH THESE
INSTRUCTIONS
Page 5
5
Mexico Super RS & CF Propane - Users
2
BOILER CONTROLS
LEGEND
A Boiler thermostat knob
B Gas control knob
C Ignition button
D Sightglass
E Overheat thermostat (optional)
reset button
Note.
Grille assembly not shown for clarity
Control of water temperature
1. Set the boiler thermostat knob (A) to give the required temperature for central heating.
2. The boiler thermostat automatically switches the main burner OFF and ON to maintain the selected temperature.
3. The pilot burner remains alight continuously to give re­ignition of the main burner.
To relight the boiler
Repeat the procedure 1 - 9 detailed in 'To light the boiler'.
Boiler Overheat Thermostat
(Fitted for sealed systems only)
The boiler is fitted with a safety 'cutout' thermostat. This thermostat will extinguish the pilot and shut down the boiler in the event of overheating. Should this occur, allow the boiler to cool, press the reset button (E) on the overheat thermostat then relight as detailed in steps 1-9 under 'To light the boiler'.
If the 'cutout' condition persists turn off the boiler and consult a CORGI registered installer.
Loss of system water pressure
(Boilers fitted with the Overheat Thermostat Kit only)
If the red arrow on the system pressure gauge is set above zero and the system pressure is seen to fall below this value over a period of time then a water leak is indicated. In this event a CORGI registered installer should be consulted.
DO NOT FIRE THE BOILER IF THE PRESSURE HAS REDUCED TO ZERO FROM THE ORIGINAL SETTING
Escape of gas
See 'Emergency Action Notice' on the back page.
Do NOT search for gas leaks with a naked flame.
Cleaning
For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth. Do NOT use abrasive cleaning materials.
Maintenance
The appliance should be serviced at least once a year by a CORGI registered installer.
Note. The appliance model is given on the data plate, located on
the front of the boiler base plate, behind the grille assembly.
RS boiler shown
The gas safety (installation and use) regulations, statutory instrument 1994, and amendments 1996, impose certain legal obligations on gas users.
Changing gas cylinders
a. Ensure that the replacement gas cylinder is the correct one for
the installation.
b. Extinguish any fire, flame or source of ignition (including
cigarettes, pipes and pilot lights) before changing the gas cylinders.
c. Change cylinders with caution.
d. Ensure that the gas cylinder valve(s) is/are closed before
disconnecting an empty cylinder or before removing any plastic cap or plug on the outlet connection of the replacement cylinder.
Never use tools on cylinder valves, hand wheels or levers.
Note. Cylinders with threaded connections have a left hand
thread. For cylinders with self-sealing clip-on valves, ensure that the regulator tap is closed before disconnection.
e. Ensure that the replacement cylinder connections are gastight.
Any leaking vapour will have a distinctive odour. Test by using
Page 6
6
Mexico Super RS & CF Propane - Users
GAS LEAK
(usually detected by a distinctive smell)
DO NOT
use electrical switches
DO NOT
look for a leak with a
naked flame
IMMEDIATE ACTION:
CLOSE all supply valves.
EXTINGUISH all sources of ignition.
Open all doors and windows.
If leakage cannot be stopped REMOVE CYLINDERS to a safe place in the open air and advise the supplier. If this is not possible, evacuate the premises and call the fire brigade.
Do not use the installation until it has been checked by a CORGI registered installer.
leak detection solution around the connections - bubbles will form if vapour is leaking.
NEVER USE A NAKED FLAME
f. It is essential that the correct pressure regulator, with the correct
pressure setting and capacity for the installation, is used in accordance with the manufacturer's instructions.
g. In the case of a connection on a pressure regulator or gas
appliance which relies upon a sealing washer to maintain a gastight joint, it is essential to check that the washer is present and that it is sound and correctly positioned prior to making the connection. Where the connection relies on a metal-to­metal seating or bullnose connection to obtain a gastight joint, it is essential that the mating surfaces be clean and undamaged.
Under no circumstances should a damaged valve or connection be used.
h. Where connections are designed to be tightened with a
spanner, it is essential that a spanner of the correct size is used and that the union is firmly tightened - hand tightness is not sufficient.
When self sealing valves are incorporated in a gas cylinder, connection should be made in accordance with the manufacturer's instructions and tools should not be used.
i. If the continuation of supply is interrupted when a cylinder is
changed, it is essential that all appliance taps are turned off before the change is made.
j. With bulk storage tanks always ensure that the site is kept clean
and clear of rubbish. Such vessels are designed to be filled on site by the gas distributors.
EMERGENCY ACTION
EMERGENCY ACTION
FIRE
IMMEDIATE ACTION:
IF SAFE TO DO SO, SHUT OFF THE GAS SUPPLY
Do not attempt to extinguish gas flame by any other means.
Raise the alarm and call the fire brigade stating that a
liquefied petroleum gas cylinder is involved, and give its location.
DO NOT GO NEAR A CYLINDER if a cylinder is being heated by fire.
ALERT EVERYONE in the immediate area of the fire and evacuate the building.
ADVISE THE FIRE BRIGADE on their ARRIVAL of the LOCATION of the cylinder.
If a cylinder is not involved in the fire and it is SAFE TO DO SO, close all cylinder valves and remove the cylinders to a safe place.
66
66
6
CARADON PLUMBING Ltd. pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice.
CERTIFIED PRODUCT Manufactured under a BS EN ISO 9001:1994 Quality System accepted by BSI
September 1999 151915 A02
CARADON PLUMBING Ltd, P.O. Box 103, National Ave, Kingston upon Hull, HU5 4JN. Telephone: 01482 492 251 Fax: 01482 448 858. Registration No. London 322 137. Registered Office: National Avenue, Kingston upon Hull, HU5 4JN. A subsidiary of Caradon p.l.c
Ideal Consumer Helpline: 01482 498660
The code of practice for the installation,
commissioning & servicing of central heating systems
Caradon Plumbing Limited is a member of the
Benchmark initiative and fully supports the aims of the
programme. Benchmark has been introduced to
improve the standards of installation and
commissioning of central heating systems in the UK
and to encourage the regular servicing of all central
heating systems to ensure safety and efficiency.
Page 7
7
Mexico Super RS & CF Propane - Users
Your feedback
and your chance to win a free boiler
At Ideal we've been leaders in the design and engineering of robust and reliable boilers for over 90 years. We want to continue as leaders by listening to your suggestions for how to improve our boilers and our service. We'll be giving away a free boiler for the five best ideas every year (to be selected by our Technical Director). Please complete this form, using extra sheets if required, and post it or fax it to us on 01482 498699.
Boiler details
Model / Size (e.g. Classic RS 230, Mexico CF 3/60 etc. Details on control panel door)
Date of Installation
Installer details
Name
Address
Post Code Telephone (Please include STD code)
How I would improve this boiler:
:
My general comments for Ideal:
Ideal Consumer Helpline: 01482 498660
Page 8
UIN 151 915 A0
CARADON PLUMBING Ltd, PO Box 103, National Avenue, Kingston upon Hull, HU5 4JN. Telephone: 01482 492251 Fax: 01482 448858.
Further information
If you would like information about Ideal Boilers please complete this sheet and fax it to us on 01482 498699 or post it to Caradon Plumbing Limited, PO Box 103, National Avenue, Kingston upon Hull, HU5 4JN.
Installer details
Name
Address
Post Code Telephone (Please include STD code)
General information required
Please send me details of Ideal Training Courses.
Please arrange for a technical representative to contact me.
Please arrange for me to join an Ideal factory tour.
Range guides required
The Ideal Guide: a specifier's and installer's introduction to the Ideal domestic boiler range.
The Ideal Householders Guide: to assist the installer when presenting to his/her customers.
Technical manuals required
The Ideal C class combi boiler
The Ideal Classic wall hung boiler
The Ideal Classic System wall hung boiler
The Ideal Classic LX Deluxe wall hung boiler
The Ideal Mexico floor standing boiler
The Ideal Minimiser heat-saving boiler
The Ideal Response combi boiler
The Ideal Response SE super efficiency combi boiler
The Ideal Systemiser SE super efficiency system boiler
The Ideal Concord high output boiler
The Ideal Buccaneer oil fired boiler
Ideal Consumer Helpline: 01482 498660
Loading...