IDEAL Mexico Super RS 3/60P, Mexico Super RS 3/100P, Mexico Super CF 3/60P, Mexico Super CF 3/140P User Manual

2
Mexico Super RS & CF Propane - Users
Mexico:
The Floor Standing Gas Boiler
The Ideal Mexico is a range of cast iron floor standing gas central heating boilers. Both balanced or conventional flue versions are available. A complete range of both natural gas and propane models. The range offers Super models and, for when space is tight, there are Slimline models available.
Mexico: Britain’s biggest selling floor standing boiler
The ideal replacement boiler...
Easy to install, easy to operate and easy to service. The Ideal Mexico really is the ultimate replacement floor standing range - you can depend on it.
Proven reliability...
Proven cast iron heat exchanger engineered and refined to be the most dependable floor standing boiler ensuring totally calm operation and quiet running, whatever the system demands.
Complete range...
27 models, including 4 Slimline models at only 250mm wide and 8 propane Super models. Option kit availability includes an easy to use programmer kit available on all models, an overheat thermostat kit for all models and a pump kit that can be housed within the casing, available for all models except the Super CF 3/140 & CF 3/140P.
Full system suitability...
All models are suitable for connection to pumped open vent central heating systems, pumped central heating combined with pumped or gravity indirect domestic hot water supply systems. They can also be used on sealed water systems when used in conjunction with the optional Overheat Thermostat Kit.
Free Guarantee: 1st Year Ideal Care
The home owner is entitled to 12 months free Ideal Care, which includes both parts and labour, to restore the boiler to full function. Please encourage the home owner to complete and return the registration form in their Householder’s pack within 30 days of installation.
Optional Extra Year Cover with Ideal Care
You may wish to offer your own annual service plan or you may wish to advise the home owner to complete their application form for the appropriate level of extended Ideal Care - Silver, Gold or Platinum. Full details are available in the Ideal Care brochure.
3
Mexico Super RS & CF Propane - Users
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components
Mexico Super (Propane Models Only)
Introduction
It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.
Gas safety (Installation & Use) Regulations 1994, amendments 1996 or rules in force.
In your own interest, and that of safety, it is the law that this boiler must be installed by a registered installer, in accordance with all national and local regulations.
Electricity Supply
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz.
The fusing should be 3A.
Connection must be made in a way that allows complete isolation of the electrical supply such as a double pole switch having a 3mm (1/8") contact separation in both poles, or a plug and socket, serving only the boiler and system controls. The means of isolation must be accessible to the user after installation.
Important notes
a. If the boiler is installed in a compartment then the compartment
MUST NOT be used for storage purposes.
b. The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically that the ventilation areas are free from any obstruction.
c. If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a CORGI registered installer.
d. Inflammable materials must not be placed in close proximity to
the appliance. Materials giving off flammable vapours must not be stored in the same room as the appliance.
e. Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.
TTB Downdraught thermostat
(CF boilers only)
This appliance is fitted with a TTB downdraught thermostat for added safety and protection. If this thermostat should operate and switch off the appliance it is because the flue is subject to downdraught, probably as a result of adverse wind conditions.
The TTB is an automatic reset thermostat which will reset once wind conditions have returned to normal, subject to a built-in reset delay in excess of 10 minutes.
The TTB is an IMPORTANT SAFETY DEVICE and MUST NOT be put out of action or interfered with in any way.
The TTB is not a substitute for an independently mounted carbon monoxide detector.
In cases of repeated or continuous shutdown a CORGI registered installer should be called to investigate and rectify the condition causing this and carry out an operational test after each intervention on the device. Only the manufacturer's original parts should be used for replacement.
Minimum clearances
A clearance of 533mm (21") MUST be available at the front of the boiler for servicing.
The minimum clearances given in Table 1 MUST be complied with, in order to maintain the safe running of the boiler.
Mexico Super CF 3/60P ......... G.C. No. 41 348 99
Mexico Super CF 3/75P ......... G.C. No. 41 349 23
Mexico Super CF 3/100P ....... G.C. No. 41 349 24
Mexico Super CF 3/125P ....... G.C. No. 41 349 25
Mexico Super CF 3/140P ....... G.C. No. 41 349 26
Mexico Super RS 3/60P ......... G.C. No. 41 349 34
Mexico Super RS 3/75P ......... G.C. No. 41 349 35
Mexico Super RS 3/100P ....... G.C. No. 41 349 36
Destination Countries: GB, IECertified - P.I. No. RS ....... 87 AT 14 CF .......... 87 AT 15