USERS GUIDE
LOGIC+ Combi
24, 30, 35
When replacing any part on this appliance, use only spare parts that you can be
assured conform to the safety and performance specification that we require.
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

IDEAL LIDEAL L
IDEAL L
IDEAL LIDEAL L
OGIC + COMBIOGIC + COMBI
OGIC + COMBI
OGIC + COMBIOGIC + COMBI
24, 30, 35
(Natural Gas Only)
Destination Countries: GB, IE
24 G.C. Appliance No. 47-348-65
30 G.C. Appliance No. 47-348-66
35 G.C. Appliance No. 47-348-67
Ideal Stelrad Group is a member of the Benchmark scheme and fully supports the aims of the
programme. Benchmark has been introduced to improve the standards of installation and
commissioning of central heating systems in the UK and to encourage the regular servicing of all
central heating systems to ensure safety and efficiency.
THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE
3

FOR ANY QUERIES PLEASE RING THE
IDEAL CONSUMER HELPLINE : 01482 498660
NOTE. BOILER RESET PROCEDURE To reset boiler, turn mode knob to reset position and immediately turn knob back to required setting.
The boiler will repeat the ignition sequence.
INTRODUCTION
The Logic + Combi is a wall mounted, room sealed, condensing combination boiler, featuring full sequence automatic spark
ignition and fan assisted combustion.
Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal
point through a plastic waste pipe at the base of the boiler. A condensate 'plume' will also be visible at the flue terminal.
The Logic + Combi is a combination boiler providing both central heating and instantaneous domestic hot water.
SAFETY
Current Gas Safety (Installation & Use) Regulations or rules in force.
In your own interest, and that of safety, it is the law that this boiler must be installed by a Gas Safe Registered Engineer, in
accordance with the above regulations.
In IE, the installation must be carried out by a Registered Gas Installer (RGII) and installed in accordance with the current
edition of I.S. 813 “Domestic Gas Installations”, the current Building Regulations and reference should be made to the
current ETCI rules for electrical installation.
It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.
4

ELECTRICITY SUPPLY
This appliance must be earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.
Important Notes
• This appliance must not be operated without the casing correctly fitted and forming an adequate seal.
• If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes.
• If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected
by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).
• Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the
appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
In cases of repeated or continuous shutdown a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII)
should be called to investigate and rectify the condition causing this and carry out an operational test. Only the manufacturers
original parts should be used for replacement.
MINIMUM CLEARANCES
Clearances of 165mm (6 1/2") above, 100mm (4") below, 2.5mm (1/8") at the sides and 450mm (17 3/4") at the front of the
boiler casing must be allowed for servicing.
Bottom clearance
Bottom clearance after installation can be reduced to 5mm.
This must be obtained with an easily removable panel, to enable the consumer to view the system pressure gauge, and to
provide the 100mm clearance required for servicing.
5

BOILER CONTROLS
LEGEND
A. Pre-heat On/off
B. DHW temperature control
C. CH temperature control
D. Mode Control
E. Boiler Status
F. Burner ‘on’ indicator
G. Pressure Gauge
H. Condensate Drain
J. Economy Mode
G
H
6