IDEAL 33-891 User Manual

SecuriTEST User’s Manual Table of Contents
Before Using SecuriTEST................................... 2
SecuriTEST Safety Precautions ........................ 3
Battery Charging Precautions ............................ 5
Standard Accessories.......................................... 8
Names & Functions.............................................. 9
General Specifications ......................................14
Meter Specifications ..........................................15
Digital Multi-Meter .............................................. 23
PTZ Controller..................................................... 30
UTP Cable Tester............................................... 36
View Information................................................. 38
WARNING
Read the “Safety Information” portion of the manual before using the SecuriTEST CCTV tester.
This manual is for users of the IDEAL SecuriTEST multi­function CCTV tester. The manual describes the operation and function of the various features of SecuriTEST.
It is highly recommended that operators read the entire manual before using SecuriTEST to prevent damage to the tester or injury to the operator.
2
WARNING
SecuriTEST Safety Precautions
When using the Digital MultiMeter function to measure voltage or current, be sure that the input does not exceed the capabilities of the tester. Overloading the tester can cause damage or personal injury.
When measuring current of unknown values, always begin with the 10A mode, then step down to the 400mA input if necessary.
Environmental Limitations Temperature: -10 to 50 degrees C 14 to 122 degrees F Relative Humidity: 0-90%, non-condensing DC input voltage: 12V +/-10%, 1A
3
1. SAFETY INFORMATION
Do not use the unit in damp conditions or environments where explosive gases may be present.
Do not handle the unit with wet hands.
Avoid dropping or causing mechanical shock to the unit.
Do not expose the ports to liquids and avoid exposure to dust.
Use only specified replacement fuses.
Do not use damaged test leads with the DMM.
Do not measure resistance on powered circuits.
When using the DMM function, set the proper mode before
connecting to the circuit under test.
When measuring resistance, make certain that the circuit is de-energized before connecting the test leads to the circuit.
4
1. SAFETY INFORMATION
WARNING
Battery Charging Precautions
SecuriTEST is capable of recharging NiMH batteries installed in its battery compartment.
To charge the batteries attach the included 12V adapter to the handset and set the main power switch to the ON position. Charging time takes 8 hours. Although the charge LED will light regardless of the position of the power switch, charging will only occur with the switch in the ON position. Operation time is approximately 3-4 hours on a fully charged set of batteries.
When using alkaline batteries the tester can run for approximately 2 hours on a new set of batteries.
When using alkaline batteries, set the switch inside the battery compartment to OFF to prevent accidental charging of alkaline batteries.
5
- Battery Precautions -
The following batteries can be used with SecuriTEST: > AA size alkaline batteries > AA size rechargeable nickel metal hydrogen
(Ni-MH) batteries
When charging batteries in SecuriTEST:
Place both the MAIN POWER and the CHARGE SWITCH to the “ON” position. The charge LED will light when the MAIN POWER SWITCH is in either position, but the batteries will charge only to “ON”. The CHARGE SWITCH is located on the upper part of
battery compartment. (Refer to the figure below)
The performance of batteries can be very different, depending on manufacturers. Please use any reputable brand for best performance. Do not mix batteries of different manufacturers when charging batteries. Make sure not to reverse the polarization of the batteries. Do not short-circuit or disassemble batteries. Make sure to check the polarization, voltage and current ratings before charging batteries. Immediately disconnect the charger should an abnormal situation arise.
when the switch is set
6
FEATURES
SecuriTEST is a portable device for testing and troubleshooting various functions of CCTV cameras. It includes functions to test video image quality, control PTZ operation, analyzes various PTZ protocols, generates video test patterns, test UTP cables and includes a full-function Digital MultiMeter.
All functions are controlled through the front keypad and on-screen display for quick and easy setup of fixed and PTZ camera systems.
2. SecuriTEST Introduction
Video Tester Displays the output signal from the
connected CCTV camera. Used to adjust aim and adjust and troubleshoot cameras.
Video signal generator mode:
Outputs color bars and Red, Blue and Green screens to allow technicians to configure monitors and troubleshot cameras by sending a known good video signal down a questionable coax run. Supports both PAL & NTSC video signal formats.
MultiMeter Measures resistance, AC/DC
voltage and current, and provides continuity beep and display hold functions.
PTZ Controller The PTZ controller tests the
movement of the dome and allows manual zoom and manual focus control of the camera. Supports various RS-485 and RS-422
7
protocols to allow operation with a variety of camera manufacturers.
UPT Cable Tester ►The UTP cable check tests
unshielded cables for continuity, opens, shorts and mis-wired pairs.
Standard Accessories
The following items are included with the SecuriTEST CCTV Tester.
SecuriTEST Handset
User’s Manual
DMM Test Lead Set (Red, Black)
AC Adapter with international plug adapters
Rechargeable AA Nickel Metal Hydride
(Ni-MH) Battery (6ea)
Neck Strap
UTP test Terminator
BNC Video Cable
Car Power Jack (12VDC)
8
Names & Functions
9
Part Name Function
Power LED
Charge LED
Data
Transmitting LED
Data Receiving
LCD 2.5” Color TFT LCD
Keypad
MODE Button
SET Button
OSD Button
FAR Button
NEAR Button
TELE Button
WIDE Button
LED
Red LED is on when the system is
switched on
Green LED is on when AC adapter
connected
Red LED is on when PTZ data is
transmitted
Red LED is on when PTZ data is
received
Main keypad for SecuriTEST
operation
Mode Select: Video, MultiMeter, PTZ Control, UTP Test (press and hold to
display main menu)
Used to confirm selection in menu screens. Press and hold to access
PTZ protocol menu
Press to toggle on-screen display on
or off. Press and hold to turn off
power.
Adjusts PTZ focus (far direction) &
Video Mode Brightness
Adjust PTZ focus (near direction) &
Video Mode Brightness
Zoom PTZ (zoom in) &
Adjusts Video Mode Contrast
Zoom PTZ (zoom out) &
Adjusts Video Mode Contrast
Direction Keys
Moves up, down, right, left for PTZ
& for menus
10
Part Name Function
MultiMeter Keys
Resistance
Button
Voltage Button Selects Voltage Mode
Setup Change
Button
Current
Measuring
Button 1
Current
Measuring
Button 2
Current
Measuring
Button 3
HOLD, HELP
Button
Test Lead Connection
Selects functions of Digital MultiMeter
Selects Resistance Mode
Toggles AC/DC Mode &
Selects Continuity Test
Selects low Current (below 4mA)
Mode
Selects Current (below 400mA) Mode
Selects Current (up to 10A) Mode
Locks Auto-Ranging Function.
Hold for HELP
Ports for Digital MultiMeter
Voltage & Resistance Port
Common Port
Current Measurement below 400mA
Current Measurement up to 10A Port
11
Port
PART NAME FUNCTION
Input BNC
Output BNC
Communication
Port
Kickstand Holds unit upright when extended
Neck-strap Hook Connect neck-strap here to hang unit
Neck-strap Hook
Connect to camera output to display
image on screen
Use as pass-through port for camera
image or to output video test signal to
external monitor
Input & Output of PTZ
communications signals
Can be used to hang the unit upside
down
12
PART NAME FUNCTION
UTP Jack Test jack for UTP Cable w/ RJ45 plug
AUX Jack
DC Power Jack
Power Switch Main Power Supply ON/OFF switch
Audio, AUX Input Port
(for future use)
DC Power Input Jack
(DC12V, 1A)
13
3. SECURITEST SPECIFICATIONS
General Specifications
Input Voltage 12V ± 10% above 1A
Electric
Characteristics
Image
PTZ Operation
Test
UTP Cable
Test Size
Battery
Built-in Charger
TV Type NTSC / PAL
Image Level 1 Vpp, 140IRE
Protocol Multi-Protocol support
Transmission
Speed
Transmission
Mode
Test
W 3.5” (88mm) X L 7.9” (190mm) X H 2.3”
Rechargeable Ni-MH battery
6ea (AAsize)
Charging
Time
Operation
Time
2400bps ~ 38400bps
RS-422, RS-485
Direct / Cross Cable, and
Broken or Short-Circuit
(58mm)
Above 8 hrs
> 3 hrs
14
3.
SECURITEST SPECIFICATIONS
Meter Specifications
Measuring
Item
DC Voltage
AC Voltage
DC Current
Measured
Value
400mV 100uV ± (0.8% + 2dgts)
4V 1mV
40V 10mV
400V 100mV
4V 1mV
40V 10mV
400V 100mV
400uA 0.2uA
4mV
4mA 2uA
40mA 20uA
400mV
400mA 200uA
Minimum
Measuring
Accuracy
± (1.0% + 2dgts)
± (1.2% + 3dgts)
(40Hz ~ 500Hz)
± (1.0% + 2dgts)
± (1.5% + 2dgts)
10A 10A 2mA ± (2.0% + 3dgts)
15
Measuring
Item
AC Current
Resistance
Measured
Value
400uA 0.2uV
4mV
4mA 2uV
40mA 20uV
400mV
400mA 200uV
10A 10A 2mV
400 0.1 ± (1.0% + 4dgts)
4k 1
40k 10
400k 100
4M 1k ± (2.0% + 4dgts)
Minimum
Measuring
Accuracy
± (1.5% + 5dgts)
(40Hz ~ 500Hz)
40Hz ~ 500Hz
± (1.8% + 5dgts)
(40Hz ~ 500Hz)
40Hz ~ 500Hz
± (3.0% + 4dgts)
40Hz ~ 500Hz
± (1.0% + 2dgts)
40M 10k ± (3.0% + 5dgts)
Continuity
Rated Fuse 250 Volt 800 mA
Beeper is activated when the resistance is below 80
16
4.
FUNCTIONAL USE
Power ON/OFF
The power switch is located on the side of the handset.
Turn the power switch on, and press
to start
SecuriTEST.
To turn off the system, press & hold
for more than 3 sec. Then, POWER OFF is displayed on the main screen with a beep. Release the button. Turn the power switch OFF to prevent battery drain during storage. The switch must remain ON to recharge the batteries. A rechargeable battery should be plugged in over 8 hrs to fully charge. The charged battery can operate for about 3 hours. When the battery indicator shows below [][], recharge it for use. (Full charge: [][][][])
OSD Setup Screen When Power is ON
When power is turned on, the OSD is displayed, and it automatically changes to the video test mode after 3-5
seconds. The initial OSD displays the SecuriTEST version and the initial setup on the screen. Product Version: 2.02 Firmware Version: 2.03 Initital Protocol: PELCO-D TV Mode: NTSC / PAL (automatic setup)
17
Battery Indicator: [][][][] User Name: User’s name (Name can be changed
in the Main menu)
Model & Software versions are subject to change without notice.
Mode Setup
Pressing the key changes the operation mode between VIDEO, DMM, PTZ, and UTP.
To directly select a mode, press and hold the
key for 3 seconds then choose a mode and press the
key again to select the mode.
Video Tester Mode:
In this mode, the image quality of the external input picture signal is tested. Unlike most monitors, SecuriTEST does not have a video input amplifier, thus picture quality problems caused by long cable runs or poor connectors will be seen. The same signal input into a standard external monitor may look fine since the monitor will boost the signal to make the image look clear. The un-amplified input circuit allows users to troubleshoot cable and connector problems that would normally go unnoticed. The VIDEO mode also outputs color test patterns to aide in troubleshooting or setting up monitors.
18
Digital MultiMeter Mode:
Use the MultiMeter mode to measure voltage, current and resistance. In the resistance mode the continuity beeper can be turned on to generate an audible tone when the measured resistance is less than 80 ohms.
PTZ Controller Mode:
In this mode, the up, down, right, left movement for PTZ cameras is controlled. Zoom and focus can also be adjusted using the Tele/Wide and Far/Near buttons.
UTP Cable Test Mode:
UTP cables are tested for straight (direct), crossover, opens, and shorts. The yellow UTP terminator must be placed on the far end of the cable to make measurements. Press the SET button to begin the cable test. The UTP test does not report the length of the cable.
View Information Mode:
In this mode, the basic information of SecuriTEST can be seen (firmware version, battery level, communications protocol and speed).
Main Setting Mode:
In this mode, the basic setup of SecuriTEST can be changed (user’s name, auto power off time, beeper, brightness, contrast, etc).
HELP:
HELP information relevant to the current mode is displayed when the key is pressed on for more than 2 seconds. This function gives a brief explanation of the current function.
19
VIDEO TEST
Connect the output of video output system to the video input BNC of SecuriTEST. Connect the video output BNC of SecuriTEST to the video input terminal of the CCTV system. The image that is displayed on SecuriTEST is passed through to the external monitor.
OSD Screen Setup
VIDEO: Indicates that the system is in the video test mode.
20
NTSC: Indicates if input or output video signal
system is NTSC or PAL. Input video signal is displayed on LCD screen automatically. Output video signal in Pattern Generator mode can be switched to NTSC or PAL,
using the
B [][][][]: Indicates screen brightness. The brightness
of the SecuriTEST LCD increases gradually
by +1 when
decreases gradually by -1 when the key is pressed. Returns to the initial setup value when one of the two keys is pressed for more than 3 sec. Changes to brightness do not effect the image sent through SecuriTEST’s Video OUT port.
C [][][][]: Indicates screen contrast, and the contrast
increases gradually by +1 when pressed, and decreases gradually by -1
when initial setup value when one of the two keys is pressed for more than 3 sec. Changes to contrast do not effect the image sent through SecuriTEST’s Video OUT port.
or keys.
key is pressed, and
key is
key is pressed. Returns to the
21
Pattern Generation Mode
To enter the PATTERN GENERATION MODE press the
key while in the VIDEO mode.
Output is changed between NTSC or
COLOR
BAR
Press
PAL, using
or keys. Output patterns can be cycled between COLOR BAR, RED, BLUE, GREEN
using
or keys.
RED BLUE GREEN
key to return to Video MODE.
22
Digital Multi-Meter
Voltage, Current, Resistance, continuity can be measured.
WARNING
To prevent an electric shock, injury or damage to SecuriTEST, turn off the power supply of the circuit and discharge all the high-voltage capacitors before testing resistance and continuity.
When using the meter function of your SecuriTEST, make sure to turn on its power and set the proper mode before connecting the test leads to the circuit to be tested.
Key Selections
Press the change to continuity mode (continuity beeper on).
Press the cycle between ACV/DCV.
This button is used to test Current below 4mA.
This button is used to test Current below 400mA.
This button is used to test Current below 10A.This input is not fused. Be careful not to measure across a live circuit (as when making a voltage measurement) when the probe is connected to the 10A input. Doing so will create a short circuit and damage the meter.
button, and then press button to
button, and then press button to
23
Description of Meter Mode LCD Window
PART FUNCTION DESCRIPTION
- Resistance test
Test Mode
Test Value
Measured Value
Graph
Measured Value
in Memory Hold
MODE Display Digital MultiMeter Mode is displayed
- Continuity test
- Set-up tests of DC/AC voltage,
current
- unit of resistance test is indicated
- Indicator of AC or DC value of
voltage or current
- AC voltage & current are indicated
as RMS (root mean square)
- Input measured value is indicated
in the form of a bar graph relative to the maximum input level of the selected mode
-
The measured value is stored and
indicated here when SET key is pressed while taking measurements
24
PART FUNCTION DESCRIPTION
DC DC Voltage test
AC AC Voltage test
OHM
VOLT
AMP
Resistance test (Measuring unit: Ω)
Voltage test (Measuring unit: V)
Current test (Measuring unit: mA, A)
Continuity test (Beeps below 80 Ω)
Measuring Resistance
The unit of measurement is
current into the circuit to measure its resistance.
. The meter sends low
How to measure: Connect the
red lead to and the black
lead to figure to the left. Measure in the resistance mode by
pressing
as shown in the
on the keypad.
25
Testing Continuity
Continuity indicates the presence of a complete path for current flow. The continuity test features a beeper that sounds when a circuit is complete. The beep allows users to quickly test continuity without having to watch the display.
How to test: The resistance mode changes to the
continuity mode, when
is pressed. The beeper is activated when the resistance between the red probe and black probe is below 80
Ω.
26
Measuring AC & DC Voltage
Voltage means the difference in electrical potential between two points. The polarity of AC voltage varies over time, while the polarity of DC is constant over time. The meter displays AC voltage value as RMS (root mean square) readings. The RMS value means the equivalent dc voltage that can produce the same amount of heat in a resistance as the measured sinewave voltage.
How to measure: First, press , the voltage measuring button, then selects AC or DC by
pressing
. When measuring DC, place the red lead on the “+” point, and the black lead on “-” point of the circuit.
27
Measuring AC & DC Current
Current is simply defined as a flow of electrons running through a conductor. To measure current, you must break the circuit under test, and place the meter in series with the circuit. The current measuring range of the meter is 10A max.
How to measure: First, turn off the power to the circuit and discharge any high voltage capacitors. Place the red lead into the mA or 10A terminals in accordance with the
value to be measured. Select one of the buttons
or .
When
mA. When 10A.
& are selected, place the red lead on
button is selected, place the red lead on
28
,
WARNING
Check the position of the test lead set in current test mode. Place the red lead at mA only when below 400mA, and place it at 10A when the value to be tested is over 400mA, or the value is unknown.
WARNING
Do not attempt to measure voltage when the test leads are connected to the mA or 10A port. Doing so will create a short circuit condition and blow the internal fuse or cause damage to the instrument and possibly cause bodily injury.
29
PTZ Controller
Connecting Camera and Monitor
PTZ Operation Test: Up, Down, Left, Right, Zoom and Manual focus control are possible. The tester can also be set to various protocols and transmission speeds (baud rates).
- PTZ Control Setup Screen Press and hold the SET button for 3 seconds until PTZ
protocol menu activates.
Address Setup
Screen
Protocol Setup
Screen
30
Communications
Speed Setup
Screen
- Keyboard Control Code Screen
- The control commands from the keyboard of an external control are displayed on the screen. Most important is that the communications speed be matched.
When you want to know the input signal of an exterior controller, you can see the input data by connecting the communications cable to the RX terminal of the SecuriTEST.
Using the PTZ Controls
PT control (Up, Down, Left, Right), is performed using the arrow keys. Zoom is controlled using the TELE/WIDE buttons, and focus is controlled with the FAR/NEAR buttons.
PTZ Function Setup
Press the select GPST / SPST / TOUR / and SPD functions. Press
to activate a function
GPST: Short for GO TO PRESET - Moves the
camera view to the designated preset location. SecuriTEST can address up to 99 stored positions in the camera. The camera goes to
the GPST position after the pressed. Select the previously memorized PRESET number using the arrow keys. When the desired number is displayed, press
key then use the arrow keys to
key is
31
to move the camera to the stored
position.
SPST: Short for SET PRESET - Memorizes
PRESET. Setup can range from 1 up to 99.
First, move the camera to the desired
position. Press the
the menu, then using the select SPST and set the address to store
using the
key once more to save the address. This function saves the current camera position into the cameras internal memory. This set position can be recalled from SecuriTEST or any other PTZ controller at a later time.
TOUR: Operates TOUR through SPST points. Can
be programmed from 1 to 99. TOUR is set using the same process described for the SPST function. To program the camera tour, the camera must support programming via the SecuriTEST interface. This is accessed by using the MENU function on the SecuriTEST PTZ screen. If the camera already has tours programmed, use the TOUR mode to recall and activate a tour that was previously saved in the camera.
SPD: Sets the speed of the camera. Programmed
using the same described for SPST. Range is from 1 to 16. Always defaults to 15 when cycling power or changing modes. High speeds are preferred to test the cameras operation while low speeds are used for precise control when storing set points (SPST).
& keys. Press the
key to activate
& keys,
32
MENU: Activates the PTZ camera’s internal menu.
Manu PTZ cameras have an on-screen menu system that allows SecuriTEST to program various functions of the camera including day/night mode, focus settings, and tours. When a tour is programmed into the camera it can be activated with SecuriTEST using the TOUR function in the menu.
33
CAUTION
Make sure to check communications protocol, transmission speed, and ID.
PTZ Control Setup
PTZ ADDR is activated on the upper part of the LCD
screen, when seconds. The menu also controls the PTZ Protocol and Baud rate.
Use the
PTZ ADDR: Select the address of the PTZ Camera.
Each PTZ camera in a system must have a unique address from 1 to 255 to allow it to be operated by a PTZ controller. Use the PTZ ADDR function to set the address of the camera to control.
& keys to move between the menus.
key is held for more than 3
34
PROTOCOL: Choose PTZ PROTOCOL
Camera manufacturer use various communications protocols to control the PTZ functions of the camera. Use the PROTOCOL menu to set the output of SecuriTEST to match the protocol of the camera system in use.
* BAUDRATE: Select TRANSMISSION SPEED
The initial setup is 2.4kbps, it can be set from 2.4kbps to 38.4kbps.
To escape from the PTZ CONTROL SETUP mode,
press the
key again.
35
CAUTION
Make sure to check CAMERA ID, PROTOCOL, BAUDRATE when testing. PTZ operation can not be done when the setup is different from the camera. If you are unsure of the cameras configuration, connect the camera to the Video IN of SecuriTEST then cycle the cameras power. Often the camera will display its PTZ configuration during the boot process allowing the tester to be set to a matching configuration.
UTP Cable Tester
Connect one end of the UTP cable to be tested to the UTP Cable Test port of SecuriTEST and the other end to the yellow UTP Cable terminator.
The condition of the cable can be tested by
pressing crossover cables as well as shorts, opens and most miswire conditions.
. The test can detect straight and
36
Crossover Cable Short-circuit & Disconnection
Direct Cable
37
View Information
Mode Setup: First, press the key more than 3
sec. and select VIEW INFORMATION. Press the
key to view the information.
Main Setting
Mode Setup: First, press key more than 3
sec. and select MAIN SETTING. Press the
key.
Select the item by pressing the
value can be changed by pressing the
& keys. Each setup
& keys. A user can enter the name he or she wants by editing USER NAME. SLEEP TIME sets the time that SecuriTEST will remain on when no button presses are detected.
38
IDEAL Industries, INC. Becker Place Sycamore, IL 60178 Customer Service: 800-435-0705
www.idealindustries.com www.idealindustries.co.uk www.idealindustries.de
Printed in Korea
Rev 2.0 May 2007
Loading...