B. After confirming the ʚ0ʛ mode, enter Temperature detection Setting mode.The LCD screen flashes the following:
Press “▲” to set the temperture to 55.0ʚ. Press and hold the “SET” button for more than 3 seconds, and the alarm buzzer will sound “BEEP” twice as choice confirmed. If sound “BEEP” is less than twice, it is not a confirmed choice.
Remark: If LCD screen does not return to Main Display, stop operation for 15 seconds, the LCD will then automatically return to the Main Display and the original tempera ture detection setting will be cancelled.
Default setting: 50.0ʚ(122.0ʛ).
<4-3> HUTR Display
day hr
<4-4> HDD Access Display
To enter the HUTR mode, the Hour signal is displayed as below: If HDD is reading or writing, HDD access signal displays the below:
Шʳ
Ч
<4-2> Temperature Detection and ʚ0ʛ Settings:
A. From Main Display, press “SET” button to enter Temperature ʚ0ʛ!SettinMod and display the following:
Press ”▲” button or “ ▼” button to switch the ʚʈʛʈʚ/
Press “SET” button to confirm your choice.
English
Back Panel Description
5.
<4-5> Overheat from original Temperature Detection Setting
HDD access signal is displayed.
Fan and alarm buzzer signals
will continuously flash.
If the fan fails or is disconnected, the LCD displays the followingǺ
<4-6> Fan Fail Alarm
HDD access and Fan signals are
displayed.
Temperature and alarm buzzer
signals will continuously flash.
Original detection set at 50.0ʚ(122.0ʛ), if temperature detected overheats the original setting. Screen using ʚ will display the followingǺ
FAN FAIL
TEMP FAIL
HDD ACCESS
POWER LED Master/Slave
SATA
4 PIN
Remark: Buzzer and alarm symbol are disabled by pressing any buttons located at the front panel.